HomeMy WebLinkAboutBLDE-22-006176 PLANS ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max Span OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF - RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 13'-2" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S-S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 2-Story 2X10 RAFTERS 15'-9" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 5/16":2.5"MIN EMBEDMENT DETAIL SNR-DC-00436 STRUCTURAL NOTES: RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE • INSTALLERS SHALL NOTIFY AR-03 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 10'-11" 16" DETAIL SNR-DC-00436 2'-1" 4'-0" 1'-9" STAGGERED ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES AR-04 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 7'-5" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1" 4'-0" NA STAGGERED OBSERVED PRIOR TO DETAIL SNR-DC-00436 PROCEEDING W/ RL UNIVERSAL SPEEDSEAL TRACK ON COMP,SEE INSTALLATION. AR-05 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 7'-4" 16" DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" NA STAGGERED . IF ARRAY(EXCLUDING SKIRT) RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE IS WITHIN 12"BOUNDARY AR-06 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 11'-0" 16" DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" NA STAGGERED REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), D1-AR-01-SCALE:1/8"=1,-0" D2-AR-02-SCALE:1/8"=1'-0" D3-AR-03-SCALE:1/8"=1'-0" THEN ATTACHMENTS NEED PITCH:31° PITCH:18° PITCH:15° TO BE ADDED AND OVERHANG AZIM:275° AZIM:184° AZIM:185° REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS r _ ••FOLLOWS: ALLOWABLE ATTACHMENT 2,-0"1 22%4„ l` 11.-6" 2,_3, 11 11 _2.t_ y-0^ k { 16'-9" {i} SPACING INDICATED ON _ 10"--- I ❑ q I❑ ❑I 5%NS TO BE REDUCED BY -4'8-4"TYP# _ _ x� _ 5.-4"TYP# ••ALLOWABLE INDICATED ON PLANS OBE OVERHANG Imo T • 1/5TH F ALLOWABLE NI I• 9._11„ ONLu67, imum 13,_3" 9'-11" ❑ ❑ ❑ ❑ ❑ ATTACHMENT NDICAOTED ON SPACINGLANS - ❑ ❑ ❑ ❑ ❑ MWUMVANEZA CIVIL MEM10" n n n n :r 1$ sunrun 5'-7" { 11'-3°-- —5'-7"— ° I k-4'— --11,_2" 1'-1" - #180120 SOS MYLES STANDLSN BLVD TAUNTON,MA,02700-7331 D4-AR-04-SCALE:1/8"=1'-0" D5-AR-05-SCALE:1/8"=1'-0" D6-AR-06-SCALE:1/8"=1'-0" PHONE Fa.0 PITCH:30° PITCH:30° PITCH:31° AZIM:275° AZIM:95° AZIM:275° CUSTOMER RESIDENCE: ROHAN AMBERSLEY g-0 54 CAPTAIN RYDER RD, 6„ I YARMOUTH,MA,02664 10"--f 11,_2" x-6,-9" # 6'-11"—x 11.2"— " } �— - 11 ----- TEL( 007 1-0^ - _ ____. YAR g^ APN:YARM-00-000077-000110 3'3" PROJECT NUMBER: 223R-054AMB1 • 3,�„ DESIGNER: )415)580-6920 ex3 ! ' 'IMII11" JEX ...----..... 10" • SHEET LAYOUT REV:A 4/15/2022 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE OMETER#: EVERSOURCE 2372559 UTILITY GRID EXISTING / 200A MAIN BREAKER I EXISTING ti 200A (N)MA SMART / ,---, MAIN (N)LOCKABLE UTILITY SOLAREDGE TECHNOLOGIES: FACILITY PANEL BLADE TYPE REVENUE SE7600H-USSN LOADS AC DISCONNECT METER 7600 WATT INVERTER JUNCTION BOX PV MODULES (3� (3) (g) , OR EQUIVALENT JA SOLAR:JAM6OS10-340/MR '^ °•-*1 O _ ^-/• 1 I 'J 'h���cii, ) JA SOWIRED IN: �y (1)SERIES OF(16)OPTIMIZERS I I L 1 ,(1)SERIES OF(15)OPTIMIZERS (N)40A -1.ueou o SQUARE 0 240V METER SOCKET LOAD RATED DC DISCONNECT PV BREAKER AT DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P340 OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE - (1)10 AWG THHN/THWN-2 $u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 BOB MYLES STAND,.BLVD,TAUNTON MA,03700-7331 MODULE CHARACTERISTICS P340 OPTIMIZER CHARACTERISTICS: FAA 0 PHONE ° JA SOLAR:JAM60S10-340/MR: 340 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 41.55 V MAX INPUT VOLTAGE: 48 VDC CUSTOMER RESIDENCE: MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11 ADC ROHAN AMBERSLEY SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC 54 CAPTAIN RYDER RD, YARMOUTH,MA,02664 SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 10540 W TEL(203)9-0-00 77 YAR APN: ARM-0000 SYSTEM OPEN CIRCUIT VOLTAGE: 16 V 7-000110 SYSTEM OPERATING VOLTAGE: 400 V PROJECT NUMBER: MAX ALLOWABLE DC VOLTAGE: 480 V 223R-054AMB1 SYSTEM OPERATING CURRENT: 26.35 A SYSTEM SHORT CIRCUIT CURRENT: 30 A DESIGNER: (415)580-6920 ex3 JEX SHEET ELECTRICAL REV:A 4/15/2022 PAGE PV-4.0 A INVERTER 1 NOTES AND SPECIFICATIONS •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 11021(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN, THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020 690.13(6) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012 SYSTEM 605.11.1.4 LABEL LOCATION. CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S)NEC 2020 705.12(C) :=7,,L,72,-':::;--',,,:-7:-.., . r.T MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION 7-7-,;:-:. sc:..t„ D.:,'sys-'7iy _ - DO NOT RELOCATE THIS - _\ OVERCURRENT DEVICE LABEL LOCATION: `' ' INSTALLED WITHIN( OF RAPID SHUT DOWN s u n r u n LABEL LOCATION: SWITCH PER CODE(S).201:NEC 2020:690.56(C)(2),IFC / �,/ SOLAR PAN ELS ON ROOF ADJACENT TO PV BREAKER AND ESS 2012:805.11.1,IFC 2018:1204.5.3 OCPD(IF APPUCABLE). PER CODE(S):NEC 2020: 4,�_„__, ^ 7os.,2(Bx3)R) , MAIN PANEL AND PV IIII ik SOLAR PV SYSTEM EQUIPPED 4±. BREAKER DISCONNECT #,60,20 885 MYLEs STAND.BLVD,TAUNTON.MA 02780-7331 PHOTOVOLTAIC SYSTEMEWITH RAPID SHUTDOWNMIMI COMBINER PANEL �E0 0 DO NOT ADD LOADS SERVICE ENTRANCE CUSTOMER RESIDENCE. ROHAN AMBERSLEY LABEL LOCATION. 54 CAPTAIN RYDER RD, PHOTOVOLTAIC AC COMBINER(IF —UNFUSED AC DISCONNECT YARMOUTH,MA,02664 APPUCABLE). PER CODE(S):NEC 2020:705,12(D)(2)(3)(c) 3 TURN RAPID SHUTDOWN SWITCH TO THE"OFF” ULM WIMP TEL.(203)906-2417 IV MY POSITION TO SHUT DOWN —SMART METER APN:YARM-000077-000110 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: • MAXIMUM AC OPERATING CURRENT:31.67 AMPS SHOCK AH ARD IN THE nil -INVERTER (EXT) 223R-054AMB1 Y. NOMINAL OPERATING AC VOLTAGE: 240VAC DESIGNER: (415)580-6920 6x3 LABEL LOCATION: 54 CAPTAIN RYDER RD, YARMOUTH, MA 02664 JEX AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF , INTERCONNECTION. ^ SHEET PER CODE(S):NEC 2020:690.54 LAONOR NOBEL OMORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 ATION: SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV A 4/15/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0