Loading...
HomeMy WebLinkAboutBLDE-22-005428 0\41) Commonwealth of Official Use Only fE. Massachusetts Permit No. BLDE-22-005428 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:3/29/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 16 CHECKERBERRY LN Owner or Tenant Holly Hansen Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(15 panels 6.0 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiative Devices No.of Ranges No.of Air Cond. TTotal No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. n 'f/��I CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) ? ''3Lo _ I certify,under the pains and penalties of perjury,that the information on this application is true and complete. J-C./an1 FIRM NAME: BRIAN K MACPHERSON Licensee: Brian K Macpherson Signature LIC.NO.: 21233 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:32 GROVE ST,DBA TRINITY SOLAR,PLYMPTON MA 023671306 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 60-61AtotAtt W/3( G (z z7-- RECEIVED �, MAR 25 201 �j permits.wareham@trinity-solar.com ----__---om n ealig o�///aaaachuaella OfficialUse y ,� •-II' :+ILDI NG DEPARTWANT ®e'7 C� Permit No. (�f�"Il _ spar of o/ _Are Jewice9 I)_ Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. I/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 03/22/2022 City or Town of: West Yarmouth, MA To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 16 Checkerberry Lane,West Yarmouth, MA Owner or Tenant Holly Hansen Telephone No. P (404) 374-65Q8 Owner's Address 16 Checkerberry Lane,West Yarmouth, MA Is this permit in conjunction with a building permit? Yes LI No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 150 Amps 120 / 240 Volts Overhead❑ Undgrd❑ No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install 6.00 kw solar panels on roof.Will not exceed roof panel. but will add 6"to roof height. 15 total panels. Completion of thefollowingtable may be waived by the Inspector of Wires. Total No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans To.of Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above In- No.of Emergency Lighting grnd. El irnd. ❑ Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners "No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW 'No.of Self-Contained Totals: _...__.. _...._.....__....._..._.. Detection/Alerti g Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal El Other Connection Heatingecuri ystems:* No.of Dryers Appliances KW No. f Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring No.of Devices or Equivalent OTHER: 15 total panels Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 31,000 (When required by municipal policy.) Work to Start: TBD Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑ BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this ap/i•, ion is true and complete. FIRM NAME: Trinity Solar Inc LIC.Na: 4434A1 Licensee: Brian MacPherson Signature Z...,` k LIC.NO.: 21233A (If-applicable,enter "exempt"in the license number line.) $us.Tel.No..508-291-0007 Address: 32 Grove St.Plvmpton.MA 02367 Alt.Tel.No.: 774-271-1858 *Per M.G.L.c. 147,s.57-61,security work requires Department of Publ :fety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner 0 owner's agent. Owner/Agent Signature Telephone No. f PERMIT FEE:$ �, Commonwealth of Official Use Only Massachusetts Permit No. BLDE-22-005428 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:3/29/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 16 CHECKERBERRY LN Owner or Tenant Holly Hansen Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(15 panels 6.0 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices ni No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Eauivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Eauivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Eauivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) 7 3.1 I certify,under the pains and penalties of perjury,that the information on this application is true and complete. ,_170t7114 FIRM NAME: BRIAN K MACPHERSON Licensee: Brian K Macpherson Signature LIC.NO.: 21233 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:32 GROVE ST,DBA TRINITY SOLAR,PLYMPTON MA 023671306 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 6/2-iivitOtAtt `��t .: RECEIVED MAR 25 202 �//q permits.wareham@trinity-so`lar.com <1[1 . --__-----o n aa��o`1//aa�ac�Cu9ella Official n y ,�T J -�' �ILDING DEPART NT c� Permit No. Z (��f`�� a Depae ni o`J} SePuice9 I' Occupancy and Fee Checked �� ,;`' BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 03/22/2022 City or Town of: West Yarmouth, MA To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 16 Checkerberry Lane, West Yarmouth, MA Owner or Tenant Holly Hansen Telephone No. (404)374-65Q8 Owner's Address 16 Checkerberry Lane,West Yarmouth, MA Is this permit in conjunction with a building permit? Yes I I No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 150 Amps 120 / 240 Volts Overhead❑ Undgrd❑ No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd n No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install 6.00 kw solar panels on roof. Will not exceed roof panel. but will add 6"to roof height. 15 total panels. Completion of the following,table moy be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No. Tot Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. g_rnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Tonsl No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons_._KW No.of Self-Contained Totals: "' '"' Detection/Alerti g Devices No.of Dishwashers Space/Area Heating KW Local 01Municipal Connection ❑ Other, No.of Dryers Heating Appliances KW Security No Systems:* f Devices or Equivalent No.of WaterKWNo.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: 15 total panels Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 31,000 (When required by municipal policy.) Work to Start: TBD Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑ BOND El OTHER El (Specify:) 1 certify,under the pains and penalties of perjury,that the information on this app lion is true and complete. FIRM NAME: Trinity Solar Inc LIC.Na: 4434A1 Licensee: Brian MacPherson Signature ..c, LIC.NO.: 21233A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No..508-291-0007 Address: 32 Grove St.Plympton,MA 02367 Alt.Tel.No.: 774-271-1858 *Per M.G.L.c. 147,s.57-61,security work requires Department of Publ afety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner 0 owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE:$ I, ,t / 1 INSTALLATION OF NEW CHECKERBERRY LANE• ROOF MOUNTED PV SOLAR SYSTEM 16 CHECKERBERRY LANE ___I WEST YARMOUTH, MA 02673 Issued/Revisions F, wr a CIVICINITY MAP SITE NO. DESCRIPTION DATE SCALE:NTS Project Title: HANSEN,HOLLY- TRI NITY ACCT A.2022-03475119 Project Address: 16 CHECKERBERRY LANE WEST YARMOUTH,MA 02673 41.654736,-70.231422 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX 1.TIRE INSTALLATION CONTRACTOR IS 6. THE DC VOLTAGE FROM THE PANELS IS 10. B)CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/SITE INFO&NOTES Drawing Title: RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS.AND REQUIREMENTS kVA KILO-VOLTAMPERE PV-2ROOF PLAN W/MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILOWATT HOUR E PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND LLININ CIRCUIT BREAKER 2.THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE MCB MCP MAIN DISTRIBUTION PANEL AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MLO MAIN LUG ONLY EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALLDRAWING DATE, 3/21/2022 DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. SYSTEM COMPONENTS AS DESCRIBED IN MTD MOUNTED DAWN BY: RG IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. MTG MOUNTING 3.THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE 16 ALL INFORMATION SHOWN MUST BE N NEUTRAL REVISED BY. RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTNmES. SIC NOT IN CONTRACT COMPONENT AND INVERTER MANUALS ARTICLE 690a 705. NOP NUMBER System Information'. PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS NTS NOT TO SCALE DC SYSTEM SIZE: MEW CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THEOCP OVER CURRENT PROTECTION ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL ABBREVIATIONSP POLE AC SYSTEM SIZE: 7,56W POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTKON MEETING AMP AMPERE PB PULL BOX MODULE COUNT, 15 THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT PH 0 PHASE MODULES USED: SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND AL ALUMINUM PVC POLY-WNYL CHLORIDE CONDUIT MODULE SPEC It DARN(DUO BLNMLG10.a.000 A.ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. M AMP.FRAME POUR POWER UTILITY COMPANY',EVE0.50URCE MOUNTED.THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR OTT QUANTITY CONTRACTOR SHOULD HAVE A MINIMUM Of INSTALLATION CONTRACTOR SHALL MG ABOVE FINISHED GRADE RISS RIGID GALVANIZED STEEL UTILITY ACCT N, 1029 706 0058 ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SN SOLD NEUTRAL UTILITY METER N. 2307079 SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING C CONDUIT(GENERIC TERM OF JSWBD SWITCHBOARD DEAL TYPE: SUNNOVA COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY.PROVIDE AS TYP TYPICAL 5.FOR SAFETY.IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND SPECIFIED) U.O.I. UNLESS OTHERWISE INDICATED THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX WP WEATHERPROOF MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT CIRCUIT XFMR TRANSFORMER Rev.No. Sheet TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER .72 MOUNT 72 INCHES TO BOTTOM INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC CU COPPER OF ABOVE FINISHED FLOOR OR IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DC DIRECT CURRENT GRADE P1 PV - 1 S.THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING CONVENTIONS OF THE NATIONAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER ELECTRICAL CODE.ANY LOCAL CODE II. ALL MATERIALS,WORKMANSHIP AND EMT ELECTRICAL METALLIC TUBING WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE FS FUSIBLE SWITCH GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL EU FUSE 7.ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH'. GND GROUND INSTALLED WITH THIS SYSTEM ARE TO BE Al CURRENT PREVAILING MUNICIPAL GEI GROUND FAULT INTERRUPTER • OD 'UL'LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY(CYCLES PER 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND) SOLAR NOTES SOLA R IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN W,PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TOAVAILABLITY OF EQUIPMENT. 2211 Allenwood Road e))-)116-)283 Wall,New Jersey 07719 www.T,InIIYSolar.com `....--- -oE- 22 -oo SLI 7-6 1A I r % NOTES'REFER TO MODULE SPECS FOR MODULE DIMENSIONS 'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTENTEE CLAMP NEW PV 60UR MODULE,7:EDUL (REFER To SPEC SHEET FOR DEraaq _� (REFER TO EQUIPMENT 6LHEDULE ECS ANOOWNTITIESI SOLAR MODULE SOLAR MODULE .1 NEW MOUNTWG FOOTI ATTACHMENT / FONTS.TYPICAL (REFER TO ECOFASTEN'V FOOT ECOFASTEN RAIL I G',/ A p OEEARN�LETTER FOR SPACING „I svEc SHEET E, DE MIq , REFER TO...EC SHEET FOR DETneq \ NEW ENOFASTEN RAILTTYPICAL ICAC QQ� any \ / ] iii TO BE MOUNTED PERPINDICULAR TO EXISTING ASPHALT SHINGLES •Imo' ECOFASTEN FLASHING Ilaii STRUCTURE(REFER TO ECOFASTEN (REFER TO ExDNEERSLEi'EAFOA - (REEEa TO SHEET FDR DE c SPECIFICATION/DATA SHEET FOR BPEOq �-� TALq DETALS) 2 7 NEW END CLP,TYPICAL $.S.LAG BOLT ,� ,l j; IREFEA TO ENGINEERS iETTEn FOR RAEcq APOC SEALANT / %'7 (REFER TO ECOFASTEN 6PEGIFICATION / \ I DATA SHEET FOR DETAILS) SOLAR MODULES SHALL NOT I EXISTING RAFTER EXCEED PEAK HEIGHT. NEW MID CLIP.TYPICAL 1 REFER TO ENGINEERS TETTER=OHSaEcs) (REFER TO ECOFASTEN SPECIFICATION I DATA SHEET FOR DETAILS) QCAATTACHMENT&CLIP DETAIL ❑PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF SLE'.NOT TO SCALE SCALE NOT TO SCALE SCALE:NOT TO 6CALE ARRAY SCHEDULE Issued/Revisions — —(PROPERTY LINE) — — BACK PI IIwEarn lowawn,nl xaNT m nwa I NO. DESCRIPTION DATE I Project Title: II HANSEN,HOLLY- I TRINITY AEU P.2022-03-675119 I I R'I Project Address: 16 CHECKERBERRY LANE I BACK • WEST YARMOUTH,MA 02673 41.654736,-70.231422 I _ I R3• I R4 Drawing Title: PROPOSED PV SOLAR SYSTEM /ACR2 Drawing Information DRAWING DATE'. 3/23/2022 DAWN BY'. RG P REVISED BY: FRONT j D System Information: I : DC SYSTEM SIZE: ,6kW EP M ACSYSTEMSIZE: 151W MODULE COUNT: 16 I______ - - - - MODULES USED: HANWW 400 MODULE SPEC C. '�10.PEA5 DUO BLS ML-510.a•400 UTILITY COMPANY:I EVERSOURCE —NOTE:SMART METER TO BE LOCATED UTILITY AMC 14297460358 NOTES: FRONT (-1 11 FROM UTILITY METER UTILITY METER P: 2357079 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DEAL TYPE: SUNNOVA WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS. 2.1 ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4)AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S)NEC 690.13(0. Rev.No. Sheet 5)ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA AR RATING. 5)ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. �� �� - ROOF 1 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE _ MODULES'0 OTT SPEC PITCH.9' NDICATES • ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE .INDICATES NEW PV ONLY SUSPAN EL ORIENTATION.37' ® ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE(UTILITY ACCESSIBLE) SP TO BE INSTALLED 15 HANW HA 400(Q.PEAK DUO BLE ML-G10.a+400) ROOFS MODULES:11 INDICATES NEW PV SOLAR MODULE.R:D MODULES ORIENTATION: 1 SEIfi00H-USOSHBNC4 OMFN)ATION:21) INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS. OC INDICATES NEW OC DISCONNECT iv REFER TO EQUIPMENT SCHEDULE FOR SPECS. ROOFIMODUIES:C - - - - • ._ OT_HER OBSTRUCTIONS ARCH:35 INDICATES EXISTING ELECTRICAL PANEL INDICATES NEW PRODUCTION METER TO BE ORIENTATION(217 EP LOCATION:INSIDE P INSTALLED OUTSIDE. SD INDICATES EXISTING SERVICE DISCONNECT SOLAR ROOF MOOULES:O - ----- - ARCH.3S' INDICATES NEW FUSED PV DISCONNECT TO BE INDICATES NEW INVERTER TO BE ORIENTATION:3]' INSTALLED OUTSIDE(UTILITY ACCESSIBLE) izi INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH IZll Allenwood Road 577-)86]283 REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey 07719 www.innity.Solarcom kA Engineer/License Holder: 1 ARRAY CIRCUIT WIRING NOTES i.)UCENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2020SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 15-400W MODULES WI 1 SOLAR EDGE P401 PER MODULE 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON 15 AOC MAX PER STRING ASHRAE MINIMUM MEAN EXTREME DRY BULB 1STRING OF IS MODULES IN SERIES-400 Vmax ____ _ B"v8" _ TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO O JUNCTION -- - INSTALLATION LOCATION.LOWEST EXPECTED AMBIENT BOX TEMP=-16'C *TERMINATED INSIDE INVERTER 1 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2%DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION.HIGHEST CONTINUOUS TEMP= 33'C 4.)200S ASHRAE FUNDAMENTALS 2%DESIGN TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED STATES(PALM SPRINGS,CA IS 44.1'C).FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING Issued I Revisions THE OUTDOOR DESIGN TEMPERATURE Of 47IC OR LESS (ALL OF UNITED STATES) S.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH •I ,swsolol4vwnxe,0cww.T yr„mIl NEC 690.12(A)THROUGH(D) N0. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC Project Title. SOURCE AND OUTPUT CIRCUIT AS PER NEC 690A1(AIM • ].)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE HANSEN,HOLLY- IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS=RED TRINITY ACCT 0:2022-03-675119 NEGATIVE CONDUCTORS=BLACK NEC 210 S(E)(2) Project Address: 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV EXISTING E�/�,�E� 240V -10 NOTE: WIRE TYPE RHW.20R EQUIVELANT AND SHALL BE 10120/240V I('"� JI INTERNAL REVENUE GRADE MONITORING 16 CHECKERBERRY LANE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT \�.1/ 150A MAIN BREAKER SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24'SHALL UTILITY METER 1500 BUSBAR _ CONTAINED WITHIN SOLAR EDGE INVERTER WEST YARMOUTH,MA 02673 CONTAIN 5 20 CURRENT CARTING CONDUCTORS AND l '- SOLAR EDGE PN.RW ND-3D-240-MB 41.654736,-70.231422 WHERE EXPOSED TO DIRECT SUNUGHT SHALL CONTAIN 5 9 CURRENT CARRYING CONDUCTORS. 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS 3 Drawing Title: OTHERWISE s OTHERWISE NOTED 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON i SMART METER PROPOSED PV SOLAR SYSTEM ROOFTOP AND SHALL BE LIMITED T012'IF USED LOCKABLE 60A DISCONNECT PRODUCTION FUSED W/400 FUSES METER INVERTER pl D OUTDOORS 240V 10 11.1OVERCURRENT PROTECTION FOR CONDUCTORS ; Lee¢e e J 10000001 lB _ /A Drawing Information CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE - '_J m'1' DRAWING DATE 3/21/2022 LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC - DRAWN BY: RG 690.9I9II3I(2) VI ` f� ��, 11 y I REVISED BY: 'I 12.)WHERE TWO SOURCES FEED BUSSRAR,ONE o io e AG j]�1 B , rf 6 (m',d',d I �»�J i -J System Information: UTILITY AND THE OTHER AN INVERTER,PV BACKFEED a¢ JI00e90e1` L1 L2 N I OC BRE7O.1 2 SHALL BE LOCATED OPPOSITE FROM UTILITY r EXISTING MAIN BREAKERl NECNE[205.12IB)(3)(Z) Im m m e a m1 I 6kW LOAD CENTER SQUARER 1 J AC SYSTEM SUE: 7.6kW 13.)AL GENERATIONSOLAR CIRCUITS LOAD CENTERS TO CONTAIN ONLY I �� CIRCUITS AND NO UNUSED POSITIONS OR INSULATED LINE TAPS INSTALLED ON PN:0222NR8 MODULE COUNT: 15 LOADS MAIN FEEDERS NEC 705.12(A) MODULES USED: HANwHA 400 14.1 ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE MODULE SPEC N. OPEAN DUO BLE MLGlo.a•400 A NEMA 3R RATING UTILITY COMPANY: EVERSOURCE UTILITY ACES N: 1429 7460058 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER I: 2307079 REQUIRED CONDUCTDAANIPA ITT PER STRING [NEC 6901(B)(1)1:(15.00.1.25)1=18.75A DEAL TYPE: SUNNOVA PV MODULE SPECIFICATIONS AWG RI0,DEBATED AMPACITY HANWHA 400(0-PEAK DUO BLK ML-G10.a+400) BBV.No. ,Sheet AMBIENT TEMP:33.C,TEMP DERATING FACTOR:.96 RACEWAY DERATING=2 CCC:1.00 Imp 10.77 INRAII,u '- (40•.96)1.00=38.40A Vmp 37.13 -_ I 01FX( t ANL i(r. II L,C;R:MF •SU .L 38.400'-18.75A,THEREFORE WIRE SIZE IS VALID Voc 45.3 A N6 TOWN-2 GEC TO EXISTING GROUND ROD P1 PV - 3 TOTAL AC REQUIRED CONDUCTOR AMPACITY lu 11.14 B 3/4.CONDUIT W/2-NB THWN-2,1M10 TNWN-7,1-010IHWN-2 GROUND 32.0010 1.25=40.00A AWG NB,DERATED AMPACITY INVERTER NI'SE7600H-USOSHBNC4 C 3/4I CONDUIT W/2N101HWH-2,1-tl10THWN-2 GROUND AMBIENT TEMP:3D'C,TEMP DERATING:1.0 RACEWAY DERATING`.3 CCC:N/A DC AC D 3/4"CONDUIT W/24110 SEWN.?,1-N30 THWN2GROUND (10• 55A•1.0=SSA Imp 15 Pout 7600 E 3/4"CONDUIT W/2-RBTHWN.2,1-N10 THWN-2.14I0 TNWN-2 GROUND • SSA'40.000.THEREFORE AC WIRE SIZE IS VALID Vmp 400 !max 32 Vmc 480 OCPDmin 40 1 010 PV WIRE(FREE AIR)W/NS BARE COPPER BOND TO ARRAY CALCULATION FOR PVENT'S?OVERCURRENT PROTECTION.3377- Isc 15 Vnom 240 G 3/V CONDUIT W/3 es THWN-2,1N6 TNWN-2,tale THWN]GROUND SOLAR 32.00A•1.257.40.00A 2211 Allenwood Road 877-7867283 -->40A OVERCURRENT PROTECTION IS VALID Wall,New Jersey 07719 www.Trinity-Solar.com i I '