Loading...
HomeMy WebLinkAboutBLDE-22-004318 PLANS SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS •SYSTEM SIZE:8520W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), SOLAR MODULES •MODULES:(24)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION --SERVICE ENTRANCE LTD:LR4-60HPB-355M INSTRUCTIONS. NI i la P o--.I oI o PAGE# DESCRIPTION •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. PV-1.0 COVER SHEET SE6000H-USS3 MP MAIN PANEL h[t • I ■I PV-2.0 SITE PLAN •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. Iqal TRACK ON COMP,SEE DETAIL SNR-DC-00436 }°—SNR MOUNT PV-3.0 LAYOUT •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. PV-4.0 ELECTRICAL WITH NEW 125 AMP MAIN PANEL WITH 100 AMP MAIN PV-5.0 SIGNAGE BREAKER. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY 51 STRUCTURAL DETAIL •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER ATTIC VENT •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 1 FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). Z T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) l"---'1 DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC n DC DISCONNECT(S) FIRE SETBACKS •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. O CB IQ COMBINER BOX I HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12)B))2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L-1 SHOWN AS DASHED SCALE:NTS A AMPERE sunrun AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #,eolzo DC DIRECT CURRENT (E) EXISTING hos MYLES STANDISH BLVD,TAUNTON,MA,02700-,331 ESS ENERGY STORAGE SYSTEM PHONE 0 ONEO FAX 0 © - EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC JULIET DAWKINS MSP MAIN SERVICE PANEL 86 EILEEN ST,YARMOUTH,MA, (N) NEW 02675 NTS NOT TO SCALE OC ON CENTER TEL.(508)680-2234 PRE-FAB PRE-FABRICATED APN:YARM-000135-000212 • _ PSF POUNDS PER SQUARE FOOT _^"=" PV PHOTOVOLTAIC PROJECTNUMBER: RSD RAPID SHUTDOWN DEVICE - _ TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL V VOLTS YUVIA SHEARER1 W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:A 1/20/2022 PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1/8"=1'-0" IF C1 SITE PLAN DETAIL-SCALE=3/128"=1'0" PITCH AZIM AZIM (SOFT) \ITS OC AC AR-01 28° 137° 151° 470.6 - SE II PM INV Soo, # \\.5S ###### sunrun ## (N)ARRAY AR-01 #180120 6.MYLES STANDISH BLVD,TAUNTON,NA 02780-7.1 PHONED FAX 0 CUSTOMER RESIDENCE: JULIET DAWKINS 86 EILEEN ST,YARMOUTH,MA, 02675 TEL.(508)680-2234 APN:YARM-000135-000212 PROJECT NUMBER: 223R-086DAWK DESIGNER: (415)580-6920 ex3 YUVIA SHEARER1 SHEET SITE PLAN (E)RESIDENCE REV:A 1/20/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2XB RAFTERS 13'-0" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. — — — S.S.LAG SCREWS: D1-AR-01-SCALE:3/16"=1'-0" 5/16":2.5"MIN EMBEDMENT S.S. AZIM:137° LAG SCREWS: PITCH:28° 5116":2.5"MIN EMBEDMENT STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS ••ALLOWABLE ATTACHMENT y 12r-5" 40r-7rr B 9FOLLOWS: { i 1' SPACING INDICATED ON ❑ ❑ 0 0 0 0 — ❑ ❑ _ -- PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG I INDICATED ON PLANS TO BE 6-10" 0 ❑ ❑ 0 0 0 0 0 ❑ I 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS --.-_-.-5r-4rr TYP__-k sunrun 6-10" ❑ ❑ ❑ 0 ❑ 0 ❑ T-11" #180120 ^ NS MYLES STANDISH BLVD,TAUMON.MA,02780]3]1 0 (3 4 PHONED ...__.. -__-_.. ..-. _._- FPllO 11'-7" —x -- ---- 28'-11 — CUSTOMER RESIDENCE: JULIET DAWKINS — 24' ---fi 86 EILEEN ST,YARMOUTH,MA, c"`ZNOFyAss9 ozs75 -1�, Cy' TEL.(508)680-2234 Or SAMUEL G BROWN u+ APN:YARM-000135-000212 iar y,py r r: PROJECT NUMBER: ''' 'No. 55ra Nom p --y 223R-086DAWK N?ham El- DESIGNER: (415)580-MO ex3 �'•- *MAI. ' YUVIA SHEARER1 Sgr. on.1/26/2022 SHEET LAYOUT REV:A 1/20/2022 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE O METER#: < M EVERSOURCE 2376865 UTILITY GRID I SUPPLY SIDE TAP tel' SOLAREDGE TECHNOLOGIES: (N)LOCKABLE SE6000H-US WITH REVENUE I NEW 100A MAIN BLADE TYPE (N)MA SMART GRADE METERING(PN BREAKER FUSED AC (N)LOCKABLE UTILITY SE6000H-USS3),6000 WATT DISCONNECT BLADE TYPE REVENUE INVERTER J 3\ C3 AC DISCONNECT<3 METER (3) 6000 WATT INVERTER JUNCTION BOX PV MODULES J �/ OR EQUIVALENT LONGI ENERGY TECHNOLOGY _� NEW \iJ < / CO LTD:GREEN E PB-355M MAIN `� o\� O — f — ��/ L -- Q/ (24)MODULES OPTIMIZERS WIRED IN: FACILITY PANEL 35A FUSES I I (1)SERIES OF(12)OPTIMIZERS LOADS 1= SQUARED SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT ' (1)SERIES OF(12)OPTIMIZERS D222NRB DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE GENERAL NOTES: # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 $u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF #180120 MAIN BREAKER IN MAIN PANEL ENCLOSURE.CONDUCTORS ARE 665 MYLESSTAND1SH BLVD,TAUNTON,MA,02790-]331 FIELD INSTALLED. PHONE 0 FAX MAIN PANEL REPLACEMENT EXISTING 100 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW CUSTOMER RESIDENCE: 125 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER. JULIET DAWKINS 86 EILEEN ST,YARMOUTH,MA, 02675 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(508)680-2234 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000135-000212 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-0OHPB-355M: 355 W MAX INPUT ISC: 11.75 ADC OPEN CIRCUIT VOLTAGE 40.6 V 223R-086DAWK MAX OUTPUT CURRENT. 15 ADC MAX POWER VOLTAGE: 34.6 V SHORT CIRCUIT CURRENT: 11.25 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 YUVIA SHEARER1 SYSTEM SIZE: 8520 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE 480 V SYSTEM OPERATING CURRENT: 22.42 A REV A 1/20/2022 SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 A�� INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE. 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(9) Ak DUAL POWER SUPPLY SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) A RAD iDS UTD0'',':.Nt -v MULTIPLE SOURCES OF POWER �•,'�ia:i,:�1:N3•:�li:�•iw•.,12;YM�:.;;/ FOR SOL AR P\ SYS-FM DO NOT RELOCATE THIS 4414110)OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:695.56(C)(2).IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:805.11.1,IFC 2018:1204.5.3 " OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: ------4"— ----- ----------{ 1111 705.12(8)(3)(2) • •I ,", A SOLAR PV SYSTEM EQUIPPED "" SOLAR PANELS ON ROOF #180120 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN sesrnvuessralloisHeuvo,rnuwroN."n,oaveo.nai COMBINER PANEL m11u F.0 nxo DO NOT ADD LOADS 11 CUSTOMER RESIDENCE: LABEL LOCATION: "" JULIET DAWKINS PHOTOVOLTAIC AC COMBINER(IF AC DISCONNECT(INT) 66EILEENST,YARMOUTH,MA, 02675 APPLICABLE). 3" TURN RAPID SHUTDOWN � PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) SWITCH TO THE"OFF' TEL.(508)680-2234 POSITION TO SHUT DOWN II APN:YARM-000135-000212 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE SHOCK HAZARD IN THE INVERTER (EXT) PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT 25.00 AMPS ARRAY. SERVICE ENTRANCE 223R-086DAWK NOMINAL OPERATING AC VOLTAGE: 240 VACSMART METER AC DISCONNECT EXT ( ) DESIGNER: (415)580-6920 ex3 LABEL LOCATION: 86 EILEEN ST, YARMOUTH MA, 02675 YUVIASH EAR ER1 AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF i INTERCONNECTION. , _ SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 1/20/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0