Loading...
HomeMy WebLinkAboutBLDE-22-003559 or Commonwealth of Official Use Only E Massachusetts Permit No. BLDE-22-003559 14\ BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/27/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 104 IROQUOIS BLVD Owner or Tenant Chris Green Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(15 Panels 5.32 KW)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Ton Total No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Eauivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Eauivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 Cl/d ‘k S w • Coinmonwealg o`//la:�acL set Official Use Only it ./ cc�� Permit No. --35 c �' 1Jepartment o/.c�7']ire Services s. _,t i_ `' Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/22/2021 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 104 Iroquois Blvd#1-02673 Owner or Tenant Chris Green Telephone No. (774)259-4367 Owner's Address same as above Is this permit in conjunction with a building permit? Yes ✓❑ No ❑ (Check Appropriate Box) Purpose of Building dwelling Utility Authorization No. Existing Service 200 Amps 120/240 Volts Overhead Undgrd 0 No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of roof mounted photovoltaic solar systems, 15 panels 5.32kW NO BATTERY STORAGE Completion of the followingtable meg be waived by the Inspector of Wires. otal No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.roof TVA Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ 'No.of Emergency Lighting g grad. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Detection and No.of Switches No.of Gas Burners Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices No.of Waste Disposers 'Heat Pump Number Tons KW No.of Self-Contained p _ Totals:_ Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal El Other Connection No.of Dryers Heating Appliances , Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters _ Sig_ns Ballasts No.of Devices or Equivalent Telecommunications Wiring No.Hydromassage Bathtubs No.of Motors Total HP _ No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 9328.00 (When required by municipal policy.) Work to Start:1/22/2022 Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE X❑ BOND 0 OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services LIC.NO.: Licensee: Nathan Ashe Signatur / _.. _. LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) % 'It1jjs.Tel.No.: 9785943519 . � ( r' 'dress: 695 Myles Stndisg=h Blvd Taunton MA 02780 / 8J/3343116 R (• k It.Tel.No.: E C E ' i r„ . « . . 147,s.57-61,security work requires Department o Public Safety 'cense: Lic.No. --------- et. ..1 , NSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally LDEC 2 required,'y :w. By my signature below,I hereby waive this requirement. I am the(check one)El owner ❑owner's agent. al , ger/ g ,t a e Telephone No. PERMIT FEE: $ BUILDING DEPARTMEtJT ay -- �. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:5325W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), r ' r SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(15)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE L LTD:LR4 80HP8�55M INSTRUCTIONS. MP MAIN PANEL i PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE3800H-USS3 PV-3.0 LAYOUT •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV 4,0 ELECTRICAL TRACK ON COMP,SEE DETAIL SNR-DC-00436 • SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE SP GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER 7_J CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER in, ATTIC VENT •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. o PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL I INV I INVERTER(S) o METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) `• F= SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC n DC DISCONNECT(S) FIRE SETBACKS •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE E INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE:NTS A AMPERE sun run AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 s, . n,,,r.,w DC DIRECT CURRENT ;� 'V - (E) EXISTING ON MIEE STuo�11.13,11.13,TAUNTON.MA 027110.7993, a Qe ESS ENERGY STORAGE SYSTEM FPHONE0 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: i* MAG MAGNETIC CHRIS GREEN \ MSP MAIN SERVICE PANEL 104 IROQUOIS BLVD, @; %., (N) NEW YARMOUTH,MA,02873 g NTS NOT TO SCALE -,Alt, CV11..r OC ON CENTER TEL.(774)259-4367 9 PRE-FAB PRE-FABRICATED YARM-000024-000138 ' 9 (,•i,r,p„a„r:; •;�,.,, ,, PSF POUNDS PER SQUARE FOOT s PV PHOTOVOLTAIC PROJECT 223R-104GREEER: RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL 9 V VOLTS NOAH ELFENBEIN W �•`„ REV NAME WATTS DATE COMMENTS SHEET SHEET REV:A 12/9/2021 PAGE PV-1.0 PV SITE PLAN-SCALE■1318"■1'-0ARRAY TRUE MAG AREA" PITCH AZIM AZIM (SOFT) AR-01 24° 16° 30° 294.1 (E)DETACHED STRUCTURE (E)FENCE (E)DRIVEWAY /1/14iftft14113 •. 1:1!122111r0r60,4 /*/*//////811 �M� • sunrun (N)ARRAY AR-01 r .. #180120 (E)RESIDENCE q p. 666IMEssrWO■H BLW,TAUNTON,MA 027.1]31 MOM 0 a° FAX CUSTOMER RESIDENCE: CHRIS GREEN Sed' 104 IROQUOIS BLVD, 0°9\ YARMOUTH,MA,02873 TEL(774)2594387 YARM-000024-000138 PROJECT NUMBER: 223R-104GREE DESIGNER: (415)580-6920 ex3 NOAH ELFENBEIN SHEET SITE PLAN REV:A 12/9/2021 PAGE PV-2.0 • 3 • ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA r Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-5" 20" COMP,SEE DETAIL SNR-OC-00438 5'-0" 2'-0" 3'-4" 1'-8" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: D7-AR-01-SCALE:1/4" 1'-0" 5/16"x4.5":2.5"MIN EMBEDMENT PITCH:24° STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY ABM:16° ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO 1.--/..—. 29,.1. 5.10" 6,$- PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), 2'-6" THEN ATTACHMENTS NEED TO BE ADDED AND j ❑ 51 0 0 ❑ 0 0 OVERHANG REDUCED WITHIN THE 12"BOUNDARY REGION 5'TYP ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON ❑ ❑ 0 0 0 0 0 PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG 10'-4" INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING ❑ 0 ❑ 0 $ AEI_ n 0 O n INDICATED ON PLANS -- -- 23'-3"— o lo n , sunrun 1 2'-2" #180120 ero W 0S STMa811BLVD,TAUNTON,MA 02710.7331 P70 0 FARO STRUCT CUSTOMER RESIDENCE: CHRIS GREEN 104 IROQUOIS BLVD, ('II) ° . YARMOUTH,MA,02673 a TEL.(774)259.4387 YARM00024-000138 � PROJECT NUMBER: 223R-104GREE DESIGNER: (415)580-8920 ex3 NOAH ELFENBEIN SHEET LAYOUT REV:A 12/9/2021 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER#: O EVERSOURCE 2305531 UTILITY GRID EXISTING C 1 200A MAIN BREAKER 1 (END FED) SOLAREDGE TECHNOLOGIES: �—.., EXISTING SE3800H-US WITH REVENUE --7„,___,:-- 200A (N)MA SMART GRADE METERING(PN j� MAIN UTILITY (N)LOCKABLE SE3800H-USS3),3800 WATT FACILITY PANEL REVENUE BLADE TYPE INVERTER METER AC DISCONNECT 3800 WATT INVERTER JUNCTION BOX PV MODULES LOADS ( n A OR EQUIVALENT (isLONGIGREEN ENERGY TECHNOLOGY J I / LTD:LR4.60HPB-355M M ; 4."--"--. « ...r•'' .--.----•.--.----• � O — + '/ (15)CO MODULES `Y OPTIMIZERS WIRED IN: I I (1)SERIES OF(15)OPTIMIZERS (N)20A lig 240V METER SOCKET SQUARE D LOAD RATED DC DISCONNECT PV BREAKER AT 100A CONTINUOUS DU221 RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END UTILRY SIDE OF CIRCUIT 3R,30A,2P COMPLIANT P401 OF BUSBAR CONNECTS TO TOP LUGS- 120/240VAC (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE 8 CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER s u n ru n 2 3/4'EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG TIHNITHWN-2 #180120 aid MYLES STAMM BLVD,TAUNTON,NA OIMD•1331 PHONE 0 FAX O CUSTOMER RESIDENCE: CHRIS GREEN 104 IROQUOIS BLVD, YARMOUTH,MA,02673 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(774)2594367 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC YARM-000024-000138 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4 60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-104GREE OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 34.6 V DESIGNER: (415)580820 j1(3 SHORT CIRCUIT CURRENT: 11.25 A SYSTEM CHARACTERISTICS-INVERTER 1 NOAH ELFENBEIN SYSTEM SIZE: 5325 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 15 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 12/9/2021 SYSTEM OPERATING CURRENT: 14.01 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0 i 5 1 41.11 INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL.SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT -- 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 890,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS.COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN THE OPEN POSmON LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC N POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(DX2),IFC 2012: SYSTEM 805.11.1.4 LABEL LOCATION: CAUTION . UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) 4 < .; MULTIPLE SOURCES OF POWER(II// t .: . ,a k --:'. :.:::1• I SOLAR PANELS - \I DO NOT RELOCATE THIS ON ROOF OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN OF RAPID SHUT DOWN s u n ru n LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:890.58(CX2),IFC ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2016:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: 4• 705.12(BX3X2)At 2020: , 4' _- J #180120 PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED IFS ESST M EC TALIPROF,,MA02/8,,391 RIME 0 COMBINER PANEL WITH RAPID SHUTDOWN FAK0 DO NOT ADD LOADS CUSTOMER RESIDENCE: LABEL LOCATION: CHRIS GREEN PHOTOVOLTAIC AC COMBINER(IFMAIN PANEL AND 104 IROQUOIS BLVD, APPLICABLE). I '" PV BREAKER YARMOUTH,MA,02873 PER CODE(S):NEC 2020:705.12(DX2X3)(c) 3" TURN RAPD SHUTDOWN INVERTER(EXT) SWITCH TOT> P" �;,MO DISCONNECT(INT) TEL.(774)259.4387 POSMON TO SHUT DOWN AC DISCONNECT— YARM-000024-000138 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: . SHOCK HAZARD IN THE PV PRODUCTION--SERVICE ENTRANCE MAXIMUM AC OPERATING CURRENT15.83 AMPS 223R-104GREE NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. IIMI METER DESIGNER: (415)5806920 ex3 CBDISCONNEICTEL (S),PHOTOVOLTAIC SYSTEM POINT OF 104 IROQUOIS BLVD, YARMOUTH, MA, 02673 NOAH ELFENBEIN INTERCONNECTION. ' ~ SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10.710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 12/9/2021 PER CODE(S):NEC 2020:880.58(C) PAGE PV-5.0