Loading...
HomeMy WebLinkAboutBLDE-22-003349 a Commonwealth of Official Use Only E ! 1` Massachusetts Permit No. BLDE-22-003349 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/13/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 41 POWERS LN Owner or Tenant SKWAR DONALD R Telephone No. Owner's Address SKWAR MARY JULIA,33 BRADFORD WALK, FARMINGTON, CT 06032 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install whole house ESS system(41.5 KW) Completion of the following table maybe waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Eauivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: ALIAKSEI A KUHARENKA Licensee: Aliaksei A Kuharenka Signature LIC.NO.: 20711 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:564 W YARMOUTH RD,WEST YARMOUTH MA 026731456 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $50.00 t4, __.A) (24t ) I2A ke Commonwea/h o/kamach.useits Official Use Only t = c/ cc�� Permit No. t 49 � 33 w 23 ; epartment o`gine Serviced 1 'I'—;tr_ Y Occupancy and Fee Checked . SOLAR PV SYSTEM+ESS ONE-LINE DIAGRAM ADDRESS:41 POWERS LANE,YARMOUTH, MA OWNER: PROKOP 120/240V DATE:6/08/2021 UTILITY 1 OF 3 SERVICE EXISTING UNDERGROUND SERVICE TO BUILDING UTILITY METER METER 200AMP 2POLE EXISTING MAIN BUILDING DISCONNECT 2POLE,120/240V,200 AMP 3X4/0 XHHW AL+#4 AWG GROUND IN 2"PVC CONDUIT ENPHASE EMPOWER TRANSFER SWITCH 200 AMP MAX. 30AMP/2P r1 -= TO SOLAR PV SYSTEM,PAGE 2 90AMP/2P rTh 2 X#2 AWG XHHW AL+#6 AWG 3X4/0 XHHW AL+#4 AL GROUND IN 1"PVC CONDUIT AWG GROUND IN 2" PVC CONDUIT EXISTING LOAD CENTER BATTERY COMBINER PANEL 120/240V240V,100 AMP BUSSBAR L_. 1200AMP J 2POLE 40AMP/2P r-Th 40AMP/2P r— rm r—• c"1 r'-1 TO(4)ENCHARGE 10 BATTERIES MAX CONTINUOUS CURRENT:16A X 4=64A EACH 40 AMP CIRCUIT CONNECTS TWO ENCHARGE 10 BATTERIES IN SERIES PV SYSTEM OUTPUT PEAK: 4.43 KW AC PV SYSTEM OUTPUT CONTINUOUS: 4.35 KW AC 15 -QTY ENPHASE IQ7+ MICROINVERTERS 15 -QTY LG 360 WATTS PV PANELS SOAR PV SYSTEM SOLAR PV SYSTEM+ESS ONE-LINE DIAGRAM ADDRESS:41 POWERS LANE,YARMOUTH, MA OWNER:PROKOP DATE:6/08/2021 2 OF 3 3-#10 AWG CU THHN+#10 AWG GROUND EXTERIOR MAIN SOLAR PV SYSTEM DISCONNECT 120/240V,1PHASE,3WIRE, 30 AMP, / NEMA 3R,LOCKABLE, VISIBLE BLADE SWITCHING ACTION ACCESSIBLE 24/7 UTILITY SMART METER METER 120/240V,1PHASE,3WIRE 3-#10AWG CU THHN+#10AWG GROUND COMMUNICATION INTERIOR COMBINER PANEL UNIT ENVOY 15AMP/2POLE 120/240V,1 PHASE,4 WIRE, REVERSE FEED RATED 20AMP/2POLE 20AMP/2POLE /"1 CIRCUIT CIRCUIT A B TYPICAL,BRANCH CIRCUIT SOLAR PV SYSTEM+ESS ONE-LINE DIAGRAM ADDRESS:41 POWERS LANE,YARMOUTH,MA OWNER: PROKOP DATE:6/08/2021 3 OF 3 (2)#12 AWG THHW CU+(1)#12 AWG CU GROUND OR 12/2 MC #8 BARE SOLAR PANEL #8 BARE SOLAR PANEL CU ■■■■■• CU •■■■■• ■■■■■■ - - - ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ M.M.M. ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ ■■■■■■ !■■■■■ MICRO i ENPHASE MICRO ENPHASE INVERTER 1Q7+ INVERTER IQ]+ L. UP TO 13 MICRO-INVERTERS - - .1-BOX ENPHASE AC INTERCONNECT CABLE-2 X#12 AWG