Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. /`, Lot 5" Zone of Contribution: In Out_ Acreage / Commercial: Residential: L_- Street: .3Q /L U C e r N /-. Village: Floor Plan: #Bedrooms: 3 Owner: Installer: R, Du '- Address: Phone: Phone: Builder: Engineer: A,v d„C.e r-,l a Z Address: Phone: Phone: N/A YES _ NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 1./' 3. 4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: t./ 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimu u i ft from foundation, deck Var.: `� 8.Leaching minimu gr full, 15 ft crawl, 10 ft slab •Var.:,j' V 9.Leaching minimum 10 ft from wetlands Var.: t/' 10.Leaching minimum 150 ft m drinking well/25 ft irrigation well Var.: �' 11.Tank/leaching minimu 10 ft om property line Var.: 5''' 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var. L- 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '/"preferred ,/ 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper,gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use I 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field ✓ 26.Electrical permit for pump chamber/Separate meter for duplexes t/ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size / 28. Septic tank/pump chamber to be factory waterproofed +/ 29. Vent provided if leaching below 3 feet,under driveway/parking I/ 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: - L� 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V. 33.H-20 loading is subject to vehicular traffic,groundwater l 34.Title V Application and permit fee,installer signature / 35. Foundation footing min.2 feet above adjusted ground water for new house _ e/ - 36.Deed Restriction required max. #bedrooms: max. flow: gpd l 37. Check area lots for groundwat r/Label groundwater in Assessor's Map Plan reviewed by: a4t.c,o - ...- / v _ 6 01 0: v r