Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH S- , WAGE PLAN REVIEW CHECKLIST Location: AM 67 LOT/6 2_ Date of Subdivision Approval Street -2 Zau4/tom S 1,cua Zone of Contribution: In Out >' Village . Varepoi..->`16 Commercial Residential )' Owner: Phan, F J adzev, a Installer 7-- /4 Builder: Engineer AYI 77c-t� AO Vc( PVC . !7� Graz 6 - /ram ( 9p( -e o`,,G�ecwav N/A YES NO 1. Required number of copies received. '7 2. Date of soils exam and percolation test not older than 2 years. L 3. 4 feet of naturally occurring pervious material, above water table(new construction) 4. Foundation 2 feet above high point of fronting road for new construction. 5. Water availability letter from Water Department for new construction. 1/ 6. Benchmark indicated and shown- NGVD if near wetlands. 7. Building sewer does not exit center of house. (/' 8. Septic tank a minimum of 10 feet from house and deck. L./ 9. Leaching a minimum of 20 feet from house and 10 feet from deck. ,� 10. Leaching a minimum of 100 feet from wetlands. /' 11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells. ,.-------- 12. System meets all other setback requirements. /.S' Jo /L,r1 t/ 13. Uses adjustment for maximum highgroundwater. 14. Leaching 4 -5 feet above adjusted water table or bottom of test pit. ✓ 15. System not in top or subsoil or 5 foot removal. �..------- 16. Proposed contours are suitable. L/' 17. System meets slope requirements - min. 1/8", 1/4" preferred. 18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. t-------- 19. Specified tee sizes are proper, gas baffle on outlet tee. ,/' 20. Sewage flow under 10.000 2pd for parcel. ,/ 21. No garbage disposal. u/ 22. System adequately sized for its intended use. 1l 23. Minimum 6" stone or mechanically compacted below the tank and d-box. L/ 24. Manhole covers within 6" of grade - septic tank and pump chamber. i 25. Electrical permit for pump chamber. ,� 26. Pump system - 2" line, weep hole, check valve, sanitary in d-box. alarm on separate circuit. c/T 7. Se tic t nk an um chamber to be Facto wate ed 28. Vent provided i leaching below 3 feet or under driveway or parking. 29. Engineer to inspect and certify : a. clay removal L/' b. wall construction schedule c. commercial system 0. En ineer and Land Surve or stam and si nature 31. H2O loading when system subiect to vehicular traffic. 32. Title V application and fee signed by a licensed installer. v 33. Foundation footing 2 feet above adjusted water table. L---- 34. Lot subdivided prior to July 31, 1986 - Nitrate Loading / -' 35. Subdivided prior to April 7, 1989 - Phos.horus on- 310'. Plan reviewed by: