HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 6 D Lot 12 Zone of Contribution: In Out Acreage 17 /�/�
Commercial: Residential: ---"
Street: .$j (AG\ clAc n -•
Village: Floor Plan: #Bedrooms:
Owner: 4 N>v,� tJ e �L (� 2 erJ
c c Installer:, c 1�C e 1r '-
Address: Phone:
Phone:
Builder: Engineer: POL.)
Al (ei p
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received
2.Date of soils exam and percolation test not older than 2 years ----
...----
3.4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: /
6. Benchmark indicated and shown-NGVD if near wetlands (/
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: / -
9.Leaching minimum 100 ft from wetlands Var.: /
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: 7
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", %"preferred
18. System meets breakout requirements PVC liner: Wall: /
19. Specified tee sizes are proper,gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel t/
21.No garbage disposal
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox L/
24.Manhole covers within 6"of grade, pump chamber cover to grade ,.../
25. Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking 7"
30.Buoyancy calculations for tank/pump chamber 1.---'.
31. Engineer to inspect and certify soils: wall: commercial. ./
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater /
34.Title V Application and permit fee,installer signature
35. Foundation footing min.2 feet above adjusted ground water for new house /
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by 6 03 01