HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 4/0 Lot 3 3 Zone of Contribution: In Out' Acreage/ O G
&•-r
f / Commercial: Residential: (f
S 71- i
Street: 3 s ,N p�s 1.rot e/l
Village: Floor Plan: #Bedrooms:
Owner: X a c, r C- . -5' Installer _D) (-
Address: _ Phone:
Phone:
Builder: Engineer: j [, Lc.
Phone:
/��S' rL�
one:
Phone:
N,'A YES NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years ✓'
3.4-5 ft of naturally occurring pervious material,above water table V/
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: i
5.Water line 10 ft from septic components Var.: t/'
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: 1/`
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: l
9.Leaching minimum 100 ft from wetlands Var.: t.
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: ,
14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable /
17. System meets slope requirements-nun. 1/8", %"preferred !�
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel v 21.No garbage disposal 1/
22. System adequately sized for its intended use z/
23.Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6"of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes 1/
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size f/
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking C.
30.Buoyancy calculations for tank/pump chamber ✓ /
31. Engineer to inspect and certify soils: wall: commercial: c/
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee,installer signature ,/
35.Foundation footing min. 2 feet above adjusted ground water for new house /
36.Deed Restriction required max. #bedrooms: max. flow: gpd 7--
37. Check area lots for groundwater/Label groundwater in Assessor's Map ."
PIan reviewed bv:
) --‘11A-j'---_____S /0 1) ' 972- c o,o;