Loading...
HomeMy WebLinkAboutEngineer Plans-- -- - ---------- FINISH GRADE OVER D-BOX 23.8' - 22.01 T.O.F. EL.= 30.9'± FINISH GRADE OVER CHAMBERS GENERAL NOTES DOUBLE WASHED PROVIDE EXTENSION RISER REMOVABLE WATER -TIGHT COVER OVER SLOPE @ 2% MIN. OVER SYSTEM 31W'TO 1-1/2 STONE TO CROWN OF PIPE NTH COVER OVER INLET & RISER TO WITHIN 6" OF FINISHED GRADE UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION OUTLET TO WITHIN 6'OF F.G. METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL FINISH GRADE N'SCHEDULE 40 PVC 7OF 1/8!'TO 1/2" DOUBLE WASHED F'DIA. OUTLET(S) @ FND. EL.= 28.6'± F.G. OVER TANK EL. 28.01+ CODE AND ANY APPLICABLE LOCAL RULES. MIN SLOPE 1 % STONE OR GEOTEXTILE FILTER FABRIC rn 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE PLACE RISER ON ALL DESIGN ENGINEER. TOP OF SAS= 20.83' 9" MIN. CHAMBERSWITH -EA611NG 41' PROPOSED4 36" MAX. Y'MIN. 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL SCH. 40 PVC 4" PVC TEE 20.00' INLET PIPES TO SEWER PIPE r 36"MAk StWER PIPE BREAKOUT EL= 20.50' WITHIN 6'OF F.G�­"e SYSTEM UNLESS OTHERWISE NOTED. MAX vy 91f L=34* 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN 6 3 3 2" DROP MIN 3" DROP N,S PE@I% PROVIDE WATERTIGHT ELEVATION = 20.59 FOR A DISTANCE OF 15'AROUND THE PERIMETEROF THE SAS. UNLESS A 4" PVC IN FROM ,,----JOINTS (TYP.) 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF SEPTIC TANK 4#1 PVC OUT TO 0 THE LINER IS, NOT LESS THAN THE BREAKOUT ELEVATION. 21± CONTRACTOR TO PROVIDE LEACHING FACILITY 0- CDC:) 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. SPECIFIED DROP BETWEEN C:) INLET AND OUTLET CONTRACTOR CONTRACTOR SHALL 127" ES I 6Z::: 1 6. THIS SYSTEM IS NOT DESIGNED FOR A DOMESTIC GARBAGE GRINDER. 20.37 MIN. C) OUTLIfT TEE 20.20 SHALL VERIFY SIZE 49' VERIFY CONDITION OF CDC> C%D 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK 6ff C CD GAS 8AFFLE RUSHED STONE AND CONDITION OF EXISTING TEES FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS C) CD EXISTING SEPTIC AND REPLACE AS OVER MECHANICALLY C> NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH TANK NECESSARY COMPACTED BASE AND DESIGN ENGINEER. 4ff 8.5'(TYP) 5 OUTLET DISTRIBUTION BOX 8. ELEVATIONS BASED ON APPROXIMATE M.S.L. DATUM. BENCHMARK ELEVATION OF 26.001 (TYP.) TO BE INSTALLED ON A LEVEL STABLE 25.0' BASE. FIRST TWO FEET OF OUTLET ESTABLISHED ON TOP OF A NAIL SET IN 11" TREE AS SHOWN ON PLAN. GROUND WATER ELEV.= < 10.03' 18.00' 12.83' 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION PIPES TO BE LAID LEVEL. THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 5'MIN. EXISTING 1 000 GALLON CONCRETE SEPTIC TANK 2 5 .0 GALLO,N CHAMBERS 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES *CONTRACTOR TO VERIFY EXISTING CROSS SECTION VIEW TO THE DESIGN ENGINEER. ELEVATION PRIOR TO ANY WORK & SEPTIC, -FANK PROFILE TY.P['AL CHAMBER PROFILE DISTRIBUTION BOX DETAIL HI-10 CHA"'>C70 DETAIL$ NOTIFY ENGINEER IF DIFFERENT, NOT TO SCALE % ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. NOT TO SCALE NOT TO SCALE 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM TEST PIT L id x PERC NO. N/A APPROPRIATE AUTHORITY. INSPECTOR: Ja� Gardine B H) 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR fV EVALUATOR: Michael Pimerital, EIT MAP 46 CS TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. C.S.E_ APPROVAL DATE LOT 36 O�t. 27,1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT DUST AND FINES. DATE: September 1, 2022 ZONE 1111f, 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE TEST PIT#: MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. Benchmark ELEV TOP 21.70' Nail Set in Tree REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, Elev. = 26.00 FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). < 10.03' ELEV WATER A < 2 mih./inch N841 551 OWE iiiiiiiillllllllllllllillillillillililliliiiiiiiiiiiiiillllllllll11111llillllllillil- PERC RATE = SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. lop :16 126.63' 28ff DEPTH OF PERC 10" 16. PROPOSED PROJECT IS LOCATED WITHIN: "01 SEWER PIP f 2± c::) p C C:e A:: "T F r (B (OH I.V TEXTURAL CLASS: ASSESSOR'S MAP 46 LOT 35 <0 flit to OWNER OF RECORD: LAURA L. FOSS co Typ) co C\1 91 7n, z Ln Loamy Sand I OYr 5/6 Loamy Sand OYr 6/1 Loamy Sand 1 OYr 5/6 Medium Sand 2.5Y 6/6 ADDRESS: 235 HIGGINS CRO LL A 21.45f YARMOUTH, MA 02673 20.87' FEMA FLOOD ZONE X COMMUNITY PANEL # 25001 C0586J 19-37' 17. DEED REFERENCE- L.C. CERT #160143 18. PLAN REFERENCE.- L.C. PLAN #28750A 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION, 17.70 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE- 21. A 4�'PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3" OF FINISH GRADE. A REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS. 22. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. in ff, � - U EXISTING f\0 No Mottling, Standing or Weeping Observed 3-BEDROOM R T 111) -4 DWELLING L_ C: k�7 IN L; DESIGN DATA 0, 0.0 50xO' EXISTING SPOT GRADE 10 TOF=30�9'± (3 50 0 EXISTING CONTOUR %5-7 35 X NUMBER OF BEDROOMS (EXISTING) 3 00 x21.8 (2 2�' DESIGN FLOW 110 _GAUDAY/BEDROOM 50 PROPOSED CONTOUR OCT 11 Tozz MAP 46 MAP 46 TOTAL DESIGN FLOW 330 GAUDAY PROPOSED SPOT GRADE LOT 35 12,885± S.F. DESIGN FLOW x 200 % 660 GAUDAY LOT 24 N \' GAS:- EXISTING GAS LINE IREPIT X, USE EXISTING 1,000 GALLON SEPTIC TANK 0/H EXISTING OVERHEAD UTILITIES YamOuth Health Departmt* W EXISTING WATER LINE C-2 r INSTALL 2 - 500 GAL. CHAMBERS W/ STONE VED 180 TEST PIT LOCATION SIDEWALL CAPACITY ame Date,-- 18" EXISTING 1,000 GALLON SEPTIC TANK (LENGTH + WIDTH) (2 SIDES) (Z HIGH) (0.74 GPD/S.F.) GAUDAY (25.01+ 12.83) (2) (2') (0.74 GPD/ S.F.) =112.0 GAUDAY A-Y'L W.971 PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE X iiiiiilllllllllllllll111111111--��S84- 56 OO`"VV BOTTOM CAPACIW PROPOSED DISTRIBUTION BOX (LENGTH x WIDTH) (0.74 GPD/S.F.) GAUDAY illillilillillillllllillillilillillllllllll1111111111111111111100oo�low EXISTING 1,000 GALILON 014 (25.0'x 12.83) (0.74 GPD/S-F.) 237.4 GAUDAY 0 PROPOSED 600 GALLON H-1 0 LEACHING CHAMBER SEPTIC TANK TO BE LWMMMJ UTILIZED IN DESIGN H; iiiiiillllllllllllom iiiiiiiiiiiiiilllllllllllllllliiiillillllll1100000 EXISTING D-' �-PROPOSED BE PUMPED,� F TOTALS: DISTRIBUTION BOX WSAND & TOTAL NUMBER OF CHAMBERS 2 ABANDONED REV. DATE BY DESCRIPTION _I APP'D., PROPOSED TWO (2) TOTAL LEACHING AREA 472.2 SQ. FT. 500-GALLON LEACHING ISTING LEACHING PIT TO BE TOTAL LEACHING CAPACITY 349.4 GAL./DAY PROPOSED SEPTIC SYSTEM UPGRADE CHAMBERS w/ STONE MPED, FILLED wl SAND & XA C FF BANDONEDI- LOCAT ION PER. TOWN PREPARED FOR: EPTICAS-BUILT DATED: 7-17-97 JOHN L_ CHURCH11" JR. ROBERT B. OUR CO., INC. CI L NO. 8066 NOTES: LOCATED AT MAP 46 LOT 34 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT 235 HIGGINS CROWELL ROAD YARMOUTH, MA 02673 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED SWING -TIES SCALE: 1 INCH 1 OFT. DATE: OCTOBER 5, 2022 LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATARHOWN ON THIS PLAN DESCRIPTION HC-1 HC-2 CORNER OF STONE (1) 48.9' 62.91 CORNER OF STONE (2) 61.1' 57.9 CORNER OF STONE (3) 71.4' 69.9 CORNER OF STONE (4) 61.3' 74.80 REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST 1 0 5 10 20 40 FEET IGWF PIT DATA. CONTRACTOR TO VERIFY THERE IS FIVE (5) FEET OF SEPARATION BETWEEN THE vow, BOTTOM OF THE NEW SAS AND GROUNDWATER. PREPARED BY: JOHN L CHURCHILL J JC ENGINEERING, INC. CIVIL 3.) ENTIRE PROPERTY IS LOCATED WITHIN A MASS DEP ZONE 11. NO. 418 2854 CRANBERRY HIGHWAY 4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. EAST WAREHAM, MA 02538 SITE PLAN INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE 508.273.0377 SCALE: 1 10' SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. Drawn By. ATB Designed By: MCP Checked By: JLC JOB No. 6490