Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. / ' 5- Lot 7 V Zone of Contribution: In Out Acreage Commercial: Residential:__(, Street: (? {*�`, - Ar _ 3 Village: Floor Plan: #Bedrooms: Owner: Q mQ 1- c= Installer: `3 Address: Phone: Phone: r Builder: Engineer: !- j.c..1 z v - y / i v ;rN,v6-it. Address: Phone: Phone: N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years j/ 3. 4-5 ft of naturally occurring pervious material,above water table v 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: (7 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: V 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: ,--71 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: le 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 1/ 15. System not in top or subsoil(A,B horizons)or 5' removal 16.Proposed contours are suitable _ 17. System meets slope requirements-min. 1/8", `/"preferred 18. System meets breakout requirements PVC liner: Wall: ✓ 19. Specified tee sizes are proper, gas baffle on outlet tee d. 20. Sewage is under 10,000 gpd for parcel , 21.No garbage disposal �/ 22. System adequately sized for its intended use [/ 23.Minimum 6"stone or compacted below tank and dbox c/' 24. Manhole covers within 6"of grade,pump chamber cover to grade ..-/ 25. Inspection port on plastic chambers/leach field f 26. Electrical permit for pump chamber/Separate meter for duplexes l' 27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size /,/ 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking I' / 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature i - 33.H-20 loading is subject to vehicular traffic, groundwater V 34.Title V Application and permit fee, installer signature / f/ 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed b _CL, 60101 17 -/C--'J-