Location(Street&Number) 10 BASS RIVER TERR
Owner or Tenant BOLGER JAMES V Telephone No.
Owner's Address BOLGER MARY ANN,25 WORCESTER RD, PRINCETON, MA 01541
Is this permit in conjunction with a building permit? Yes 0 No ❑ (ChePiaiic
Purpose of Building Utility Authorization N . PAmilliNExisting Service Amps Volts Overhead ❑ Undgrd .o A7;20"'"
New Service Amps Volts Overhead ❑ Undgrd C� $ r Number of Feeders and Ampacity ; CAr
Location and Nature of Proposed Electrical Work: Installation of generator.
P
Completion of the following table may be waived by t - 4.,.ctor of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators 1 KVA 24
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee
provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such
coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Mark L Avery
Licensee: Mark L Avery Signature LIC.NO.: 13272
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address:77 AGNES RD, SOUTH DENNIS MA 026602814 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent , „,
Signature Telephone No. PERMIT FEE:$100.00
'FP-mat k e-mixtr 1 /.7_, eg.
{yip_ -t(i(2, 14.
Commonwealth.o`Maddachuee Official Use Only
r
rt=-_ 't c� c7 Permit No. v1 ' 2-3 e
2 artmenf o ..tire service!
--
_'=t=f-= Occupancy and Fee Checked
'�—`_ BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank)
y.
„44
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 10/29/2020
City or Town of: Yarmouth To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 10 Bass River Terrace
Owner or Tenant Jim Bolger Telephone No. 508-560-6654
Owner's Address 10 Bass River Terrace,South Yarmouth MA 02664
EIs this permit in conjunction with a building permit? Yes ❑ No El (Check Appropriate Box)
0 Purpose of Building Single Family Residence Utility Authorization No. n/a
J Existing Service 150 Amps 120 / 240 Volts Overhead Q Undgrd❑ No.of Meters 1
SNew Service Amps / Volts Overhead 111 Undgrd I=1 No.of Meters
Number of Feeders and Ampacity
aLocation and Nature of Proposed Electrical Work: New whole house 24kW standby generator with outside transfer switch.
0) (all work is outside)load sheet attached-TWO INSPECTIONS,will be calling for trench and a final.
.' Completion of the following table may be waived by the Inspector of Wires.
t" No.of Total
kNo.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
3 No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
S. No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
Heat Pump Number Tons KW No.of Self-Contained
No.of Waste Disposers Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other
Connection ,
No.of Dryers Heating Appliances KW Security Systems:*
J No.of Devices or Equivalent
'• No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
t No.Hydromassage Bathtubs No.of Motors Total HP
Telecommunications NofDeieor Equivalent No.of Devices Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: 12,000 (When required by municipal policy.)
Work to Start: 11/01/2020 Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ❑■ BOND ❑ OTHER El (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and co 'lete.
FIRM NAME: Mark L.Avery C.NO.:
Licensee: Mark L.Avery Signature �/ LIC.NO.:13272
(If applicable,enter "exempt"in the license number line.) 'us.Tel.No.:508-896-8890
Address: 77 Agnes Road,S.Dennis MA 02660 Alt.Tel.No.:774994-0626
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. SS-002294
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner El owner's agent.
Owner/Agent I PERMIT FEE: $100.00
Signature Telephone No.
04vevy. GENERAL'
Electric
MARK AVERY INC
77 AGNES RD
SOUTH DENNIS,MA 02660
(508)896-8890
MLAelectric.com
Sizing Report
Sizing Information for:
Jim Bolger
10 Bass River Terrace
South Yarmouth,MA 02664
Rated Nominal Voltage 240
Generator Fuel Choice Natural Gas
Sizing Method(NEC 220) Part IV
(Part III required for selected circuit implementation,Both valid for whole house)
General Lighting&Receptacles Load(kW)
Square Footage Being Covered(ft^2) 3000 9
Small Appliance Circuits(20 amps)
Kitchen Circuits 2 3
Laundry Circuits 1 1.5
Managed Estimated Nameplate
Fixed-In-Place Appliances&Motors Loads (kW) (amps) 240 V Load(kW)
Microwave 1.3 0 1.3
Range-Oven w/Top 8.5 1 0.1
Furnace(Forced Air) 0.7 0 0.7
Dishwasher 1.5 0 1.5
Refrigerator 0.8 0 0.8
Managed Estimated Nameplate
Air Conditioning&Cooling Loads (kW) (amps) 240 V Load(kW)
5.0 Ton Unit 5.0 0 X 5.0
2.5 Ton Unit 2.5 0 X 2.5
Managed Estimated Nameplate
Heating&Heat Pumps Loads (kW) (amps) 240 V Load(kW)
Estimated Actual Utilized
Transient Requirement (LRA) (LRA) (LRA)
Largest Motor's Starting Amps(LRA) 144 0 144
Load NEC
Summary NEC Load (kW) Required
General Lighting&Receptacles 13.5
Fixed-in-Place Appliances&Motors 4.4
Sum of all General Loads 17.9 13.1
Cooling 7.5 7.5
Heating(w/demand factors) 0.0 0.0
Larger of Heating&Cooling 7.5 7.5
Sizing based on requirements of NEC Article 220,Part IV 20.6
Elevation 0 ft
Minimum size generator for motor starting requirements 20
BTU load required 306000
24 kW Generac Model Generator Recommended
Recommended Pipe Size
Product Line Generac
Generator kW 24kW
Length of Run 50'0"
90°Elbows 6
45°Elbows 0
T Connections 1
1 1/4" Pipe Size Recommended