Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 7 8 Lot 7/ Zone of Contribution: In Out�Acrea_e / �QD J Commercial: Residential: Street: 7 (7Qp' , CL -e Village: Floor Plan: # Bedrooms: 7 Owner: - c, -F"ti/ Installer: !� .-n,-s� R(J 6 Cr Address: Phone: Phone: Builder: Engineer: L _C p ,g, __Sz 74j Address: Phone: P Phone: N/A Y,✓ES I N O 1 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years I \i/. 3. 4-5 ft of naturally occurring pervious material, above water table 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: t8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: j IJ.d 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: lt 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil (A,B horizons)or 5' removal ! t� 16. Proposed contours are suitable 17. System meets slope requirements-nun. 1/8", `,!"preferred 18. System meets breakout requirements PVC liner: Wall: i 19. Specified tee sizes are proper, gas baffle on outlet tee ' 1,---'#'4, 20. Sewage is under 10,000 gpd for parcel 21. N garbage No, disposal 22. System V �ys em adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox I 7 i 24. Manhole covers within 6"of grade, pump chamber cover to grade ( 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes V 27. Pump system-2" line,weep hole,check valve, tee in dbox,pump size 28. Se tic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: . 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature I 33. H-20 loading is subject to vehicular traffic, groundwater t/ 34.Title V Application and permit fee, installer signature j 35. Foundation footing min. 2 feet above adjusted ground water for new house 7,/ 36. Deed Restriction required max. #bedrooms: max. flow: gpd I / 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: eti__67 6,.,, / ) -1{- 01 2