Loading...
HomeMy WebLinkAboutBLDE-21-007350 Commonwealth of Official Use Only Massachusetts Permit No. BLDE-21-007350 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:6/17/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pertorm the electrical work described below. Location(Street&Number) 24 GOOSENECK RD Owner or Tenant PAINE IRENE M Telephone No. Owner's Address WOLF JAMES G, PO BOX 823, YARMOUTH PORT, MA 02675 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system. (39 Panels 13.06 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: SOLAR WOLF ENERGY Licensee: Kyle Zuidema Signature LIC.NO.: 22593 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 771 Washington Street,Auburn MA 01501 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER: I am aware that the License does not have the liability insurance coverage normally required by law. But signature below,I hereby waive this requirement. I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 , \II() Conunonweat'.th o`//laaaachuastta it1 iI 1 ✓? nr Official Usc Only - --i3r) . �.g_. �- 2sparinunt`o`3irs Servicsa ..- ' � a t 1 'Occupancy. and tie Checked %� BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) l APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK 1 All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORM4TION) Date: 6/10/2021 E City or Town of: Yarmouth Port To the Inspector of Wires: U By this application the undersigned gives notice of his or her intention to perform the electrical work described below. rn Location(Street&Number)24 Gooseneck Rd Yarmouth, MA 02675 O Owner or Tenant James Wolf and Irene Paine Telephone No.508-240-4851 42 Owner's Address 24 Gooseneck Rd Yarmouth, MA 02675 O Is this permit in conjunction with a building permit? Yes El No n (Check Appropriate Box) to Purpose of Building Residential Utility Authorization No.5757780 O — A Existing Service 200 Amps 1204240 Volts Overhead Undgrd XC No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd 11 No.of Meters t Number of Feeders and Ampacity Cl) 'o Location and Nature of Proposed Electrical Worldnstallation of a 13.06kW roof mounted solar array using 39 SunPower 4. SunPower 335W panels with built-in microinverters. Installing empty meter socket for SMART gen meter V) Completion of the following table may be waived by the Inspector of Wires. lSze: No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA q No.of Luminaire Outlets No.of Hot Tubs Generators KVA n No.of Luminaires SwimmingAbove [n- No.of Emergency Lighting Pool grnd. ❑ grnd. ❑ Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners 'No.of Detection and Initiating Devices •No.of Ranges No.of Air C'ond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW LSecurity Systems:* No.of bevices or Equivalent No.of Water Kw, No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP -TelecommunicationsNofDevices or qui agl No.of Devices Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 19,048.80 _ (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify, under the pains and penalties of perjury,that the infor ation pn this a plication is true and complete. FIRM NAME: Solar Wolf Energy LIC.NO.: 186400 Licensee: Kyle Zuidema Signature li,r‘.,' LIC.NO.: 22593A (if applicable,enter 'exempt'.in the license number line.) Bus.Tel.No.: 508-839-2222 Address: 771 Washington St Auburn Ma 01501 Alt.Tel.No.: *Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ Customer: Jim Wolf Irene Paine SOLAR WOLF Address: 24 Gooseneck Rd Yarmouth Port, MA 02675 inc.bt. System size: 13.06 kW Yr 1 Production: 12,380 kWh Designer: Solar Wolf Energy Site Assessment Date: May4th,2021 c ::* t. ." - = IL 'B . 1. - �` y�. � i s sue_ ae+ ro. r<€ „ ? mot aT' '/'?‘'' ...,„, 41, .., t r s lif T t.Zr[,/ s " 4 - ... 'teai'cW „` £a: ,� t� {ma ` s ',s a r t .4k, ... 44t - .s. v ,r . : „s` y`/1 s ra Site Assessment Customer: Jim Wolf Irene Paine Address: 24 Gooseneck Rd Yarmouth Port,MA 02675 - • Component List -y. • Id 4 Manufacturer Model Quantity Sunpower Corp. SPR-X21-335-BLK 39 fI Enphase Energy Inc. IQ 7+ 39 Aftek ssr Notes: >.5 o .0 m O j,c V Li m { 0 m cc po a oo a° EmE' = _lT N J € J m o, ` E0 iw, ! m -0 i • F c ;} , '' s s o ' �i Y { �' + 1 1 ®-e g§ iii Fes.. , Z 0' ' i. Z 74> J a 'i t, o a w � O a > ,��r. •e~ 1- `m�- = E Li) off¢ E,i Qr gr J Z m g E m c n n E 3 u 0 Q l OU (MA. 0aa-0o > en •• , I r CO a 2 w O Dm j Z O 2 w CC o 0 0 0 (Noe NQ c Q r W W in N Z �i of a v>>i ro m of il 3 ° ° ° ° aw m Nm j W O N�O w Ce2 ° d u_W 0Z ~ NN2 O Qw (lc 00-W } O_ a m(n(n m _ �N mUo ppw Q' 20 2 Om> I- > tngr a °� a Uw ce cow a w ~ w oiwvio e, �'<az m ¢V O wY 2 a U , aw rr = ° 005p�ctaw�jwza Z UU n ,,0 Z Qajt- p z �ZO 0 ° ° 8w waw 0zOU2mmm-,z2 Hr w c�F J amy lLL Ztetm x Y Z HDDH 0poU9! � a I- vt rozmt zzdH3 - 5,< F, E 2 4lc W ow ZaJp;-m OF Q'rpJ2= w 8 az_ H w Z12pr n W '-N j H J D OUO% w r w w 94 ] U r � r o 0 0 0 o O Q � X W U F" a ° 2 Q Z w0wNNNNNa JU } UU w W 2m f m UOM W 2 1- w i R k o p r o 0 F_=a� aa° {n oa W MN. CO N w (n a Q 2 a 2 :2,, g& tc liii = iIii ° am a % v macm csacCl G=m o c �mc 3D `v Nmm.,C = .2mDENm 3 UN 2 am O ON mgN -0 g` NGO` Ga ' = ' c OE m' a _ tm` C ` $natot Elbe gcma R " % E3Ez @a mrn cm `cDaNcNNm vo,.. m` N c o£ a ao, R&cc umoc �8. �mcZ E o,c "mc° m nRU 0m yoG €F aS °'o m ... m a mt9aogo d O ha ,- .915 3 LI.r C.Q my ug%2` Q0° m aNvi' m a'ea.=.. m 5' G o,¢��=°2'coo G o E+o¢m v m ta r nuoN cm ZoG G o, V_ o 2mc ' gpNmym a t VN` N € Cp No m,. GpN,,i.6°N- m F UCNVS . 3Roa koN$Nam o3aa l%oo,2mmc- _ oc, O g "�1 ` °moym 0E° y " oo�= et wmYc0 aZ !!r2' a .16R8 3c -�Ew HEmu gaea 3ooau' cm ;. aacteamem3 % m _oayUaocm� cEf§m£ � ao ° el—Ac Q QNmcooctoa m,m --O mo2-om , =,� ` _ oc ry 2mEa ° , c'JG,,. Nyo;Gm2„,„ . ,g.g.. „ 2Eam. ag= G 'am Cmm�y ..8@Q > O Ea 'm" . 8Eo, pm2 UcamJ m.N.Emg� 8mc Svsi ,0,-a80 Gxr ;gm . 8 m„„,e' 0ma2,"1` , .a °mE$ gogG0%tc ma c0pE Oam.,N ' gym .amCac_, .W �m�o.mvm,2 ,m ott:t :ENm3 > 2a? r o m,,2ee oa`m = . .t. osZ ¢- UoOcU5 $0aaQQ=hp3_ py . 0 O o`v hm�Eao0G� Ea¢¢ E� n= ,, Ov - NofQ Yi o , 0 of 0- tVh V . . n .Ot ' NOc SOLAR MODULES INDEX 39 SunPower MM MSP (E) 150A Main Service Panelt ''�/NAMICRONVER ERLK-E-ACpVS (N)100A PV Sub Panel INVERTER TYPE:MicroAC (N)100A AC Disconnect W / c , E 39 FACTORY-INTEGRATED 270 90 Model#X21-335-BLK-E-AC(240V) JB (N)Junction Box ;���D� PV PM` AC EMT Conduit • MM MSP FMTConduit setback . Setback , ' SCALE: 1/8"=1'-0" ^/ ,,a O a eeG a CONTRACTOR Goo` i Solar Wolf Energy 8 / Address:771 Washington St. �� Auburn,MA 01501 �' Solar PV Array 1 Phone number:(888)878-4396 22-SunPower 335W Modules License#:B-940672 Ilk, Q a 22-Built-in Microinverters NI Pitch:28 Deg SOLAR WOLF 4 ik Orientation:108 Deg ,.1m4`'. Satellite „< SwO�. Oa /' JB1 1 / , „ 01m yJB4 0 tlit i0 V ®� ��b Solar MiAmy3 • 0 • 3-SunPower 335W Modules � 3-Built-in Microinverters ®1 Pitch:28 Deg a 0 JB344111, Orientation:198 Deaill • SITE MAP 8r PV Solar er 335WArray 2 LAYOUT 14-SunPower icr Modules • �O 14-Built-in Microinverters a• Pitch:28 Deg •Orientation:288Deq 414 Drawn by: Areg Aghayanrs SolarPaperwork.com suPPO 06104 rpa2erwork.com . DATE:06/04/2021 Pro,.Name James Wolf 24 Gooseneck Rd Yarmouth Port,MA 02675 NOTE: Conduit in attic shall Scale PV SYSTEM AS INDICATED be minimum 18 inches from roof sheatinq PV 1 .0 NOTE:Service Panel does not contain center fed Main Breaker SUNPOWER TRUNK CABLE (2)#12 AWG PV WIRE (1)#8 EGC • FREE IN THE AIR SINE SIDE TAP / /' / / INSTALL(3)20A PV 2-POLE CB100A FUSED AC DISCONNECT. �o• PV100A. 20 VEL WITH 7LVt FUSES VISIBLE LABELED O 100A,120/240V, MA SMART LOCIWBLE,BLADE TYPE, �r Jaox1 `NEMA 3R GENERATION METER NEMA3R / MA''ETER NEMA3R #10 AWG THWN/THWN-2 \ 400 KW 120/240V 120/240V Al la % O (1) NEMA 3R (UTILITY REQUIRED)NON CENTER 160A EXISTING L� (1)#8 AWG GND / / er• MAIN CB IRA_MAIN 4"FMT 20 FEET \Ili [ %' C O _ SERVICE a t:•^ O•. �.7 I PANEL u JOt uo g ■■■■ iii ga u iiii m g ■■•• ^ ^( "'Nil% --) ® -- CONTRACTOR JaDx2 (8)#10 AW W G THN/THWN-2 m_ O NEIAA3A (1)#8 AWG GND / Solar Wolf Energy nr 3/4"EMT.10 FEET I Address:771 Washington St. _¢_■e - -ui - oo: / (8)#10AWGTHWN/THWN-2 Aubum,MA01501 u II •■■■ 1 #8 AWG GND _Z � �� (1)#10 AWG THWNlrHWN-2O (3)#6 AWG THWN/THWN-2 (1)#8 AWG THWN/THWN-2 = Phone number.672 878-4398 1 ■■■■ 3/4"EMT.5 FEET #8 AWG GND 1m ■■■• (1)#8 AWG GND ()#E AWG GND (3)#8 AWG THWN/THWN-2 License#:8-940872u ���� 3:iiV 3/4"EMT 10 FEET 3/4"EMT 2 FEET 3/4"EMT 2 FEET (1)#8 AWG GND (E)GROUNDING �•a y 3/4"EMT,2 FEET ELECTRODE SYSTEM n Jam, (4)#10 AWG THWN THWN-2 t�O SOLAR WOLF IMAMS (1)#8AWGGND "`•+'' t"t' m 3/4"EMT.10 FEET _ oo uto uru co u :: :::: ���� PV ARRAY RATING i WIRE SIZE CALCULATION U r �� Tema BRANCH CIRCUn--A BRANCH CIRCUIT-A Number Modules 11 Type Sunpower AC 335 Watt SPR-X20-335-BLK-E-AC Number OFMkrolnw.ters In drcult 11 Number M/nolnwrtrn Type Sunpowrr 335 Watt AC SPR-XSO335-BLK-D-AC Mkralnwrter Maximum Output Current(A) 11 Foctory-Interaroted Mlcrolnverhro (240V) 1.31 Location Wottt STC(Warts/Module)11•335=3685 Brooch Cirtu/t Total Current(A) 11•1.31•1.25=11101 u *1 .....•Q Array Currents HSC N/A A I-MP N/A A Breaker Site Per Branch Circuit(A) 20 U= •••• ■■■■ J BOX Module Voltage V-OC N/A V V-MP N/A V 2 H■■ ■■■ ■■■■ COU ••• ■■•■ NEMA3R BRANCH CIRCUIT-B BRANCH CIRCUIT-B mU fN: �� .1:: Number Modules 9 Type 5unpower AC 335 Watt SPR-X25335-BLK-E-AC Number OFMlcrolnwrtero In Omult 9 — Number Mlcrolnwrters type Sunpower 335 Watt AC SPR-X20-335-BLK-D-AC Mkro/nvernr Maximum OutWt Current(A) g Foctory-Intergroted Microinvertero (240V) n 1.31 Location Watts ST4(Wntts/AMdule)9.335=2680 Branch Circuit Total Current(A) 9•1.31•1.25-14.74 Array Currents 1-SC N/A A I-MP N/A A Broker Slag Per Branch Circu&(A) 20 • 12 Module Voltage V-OC N/A V V-MP N/A V =U •••• ■■■■ •■■■ BRANCH CIRCUIT-C BRANCH CIRCUIT-C 'S •••• •■■■ SPR-X20-335 -E-AC Number OFMkralmertrn M Orcun 12 � •••• ■■■■ Number Modules 12 Type 5unpowerAC 335 Watt u :::� m •••• ■■■■ ■■■■ Number Mlnalnverters Type SunpOWH 335 Watt AC SPR-X2O335-BLK-O-AC Mkrolnverter Maximum Output Current(A) U ('■■■ ■■■ •■ 12 Foctornintergrohd Mlcroinwrters (NOV) 1.31 Location Watts SIC(Worts/Moduh)I2•335.4020 Branch Circuit Tote!Current(A) 12.1.31•1.25=19.65 ELECTRICAL 1-LINE Array Currents PSC N/A A I-SW N/A A Breaker She Per Branch Circuit(A) 20 DIAGRAM Module Voltage V-OC N/A V V-MP N/A v Li-- BRANCH CIRCUIT-D BRANCH CIRCUIT-D =O Le■n OTr. •n `J Number Modules 7 Type Sunpower AC 335 Watt SPR-X20-335-BIX-E-AC Number OF Mkroinwrhrs in Circuit 7 •••■ ■ u• Drawn by..U ■■■• • ■■■ Sunpowrr 335 Watt AC SPR-X20-335-BLK-D-AC j ■■■■ ■ ■■■ Number M/troMwrtrro Type Factory-intergrand Mioo/nwrters Mkrolnwrhr Maximum Output Current(A) Are A he ants u•■ uo• 7 (24ov11.31 9 9 Y i_ iiii it LocaeMn Woeh sTS(watts/Modaa)7.335.2345 Branch arcalrToro/torrent(A) 7•1.s1•its,1146SoI8TPapenvork.com u r■■• •■ SUODerre6s018(paperwork.00m Army Currents PSC N/A A I-MP N/A A Breaker SIN Per Branch tbcult(A) m. DATE:06/042021 39 SUNPOWER 335 WATT MODULES Module Voltage v-oc N/A V V-MP N/A v 39 SUNPOWER INTEGRATED MICROINVERTERS FROM/BOX TO ENPHASE COMBINER BOX James Wolf Maximum Conen/us Current(A)I 19.65 Man Than 3CCCAdlist Factor 0.7 Adjusted ConductorAmpvclty(A) I 19.65/0.7.21107 aoporty Masa Raceway Height From Roof(Temp 39.22=61C) 31/2" Ie of wire(R BC•2) I B AmblendT Factor Per NEC Table 310.15(b41Na) 10.71 24 Gooseneck Rd Temp.Deere Factor(max confnoa:current divided ambient tem.Factor(A) 28.07.0.71.39.54 wire Sln/mm NEC Table 310..15(b)16 f 10AWG Yarmouth Pon,MA 02675 FROM ENPHASE COMBINER BOX TO MAIN PANEL s.4STotal Number OfMkrohwrtero I gg 'Total Am Amps From Al!All Mlcrolnrters(A) 39.1.31.51.09 Consider Continuous(A) 51.09.1.25.63.8625 PVV A SYSTEM AS INDICATED Temp.Denote Factor(0.91 at wall of the Building)(A) 63.8625/0.91.70.18 Win Sin from NEC Table 310.15(6)16 6A WG - \ --- Amblend Tent Factor Per NEC Table 310.15(b52Na) 0.911 PV 2.0 LABEL 1 LABEL 2 LABEL 3 LABEL 4 LABEL 5 LABEL 6 CAUTION CAUTION WARNING! SOLAR PV SYSTEM EQUIPPED WARNING! PV SUB-PANEL ONLY AUTHORIZED SOLAR SOLAR OC CURRENT PRESENT ELECTRIC SHOCK HAZARD. WITH RAPID SHUTDOWN ELECTRIC SHOCK HAZARD. PERSONNAUONLYI DURING DAYLIGHT HOURS IF GROUND FAULT IS INDICATED, DO NOT TOUCH THE TERMINALS. NORMALLY GROUNDED TURN RAPID SHUTDOWN TERMINALS ON BOTH THE LINE AND (TO BE LOCATED ON (STICKER TO BE LOCATED ON CONDUCTORS MAY BE SWITCH TO THE LOAD SIDES MAY BE ENERGIZED IN SUB-PANEL ONLY CONDUIT WITH DC CURRENT UNGROUNDED AND ENERGIZED. "OFF"POSITION TO I.ory :ctrI THE OPEN POSITION. WHEN SUB-PANEL IS EVERY 4'HORIZONTALLY OR SHUT DOWN PV SYSTEM DEDICATED FOR PV ONLY) 10'VERTICALLY AND 1'FROM AND REDUCE EACH SIDE OF A BEND) SHOCK HAZARD IN THE ARRAY LABEL 7 LABEL 8 LABEL 9 LABEL 10 LABEL 11 WARNING! PV LOAD CENTER SIZED FOR PV AC DISCONNECT THIS PANEL FED BY SOLAR INVERTER OUTPUT CONNECTION.DO NOT BREAKERS ONLY OR RENDERED UNABLE CONTRACTOR AC PHOTOVOLTAIC POWER SOURCE MULTIPLE SOURCES RELOCATE THIS OVERCURRENT DEVICE TO ACCEPT ANY ADDITIONAL LOADS. RATED AC OUTPUT CURRENT:63.86 A MAX (UTILITY&SOLAR) NOMINAL AC OPERATING VOLTAGE:240 Vac (STICKER LOCATED (STICKER LOCATED Solar Wolf Energy (STICKER LOCATED Address:771 Washington St. INSIDEPANEL INSIDE PANELON THE PV SUB PANEL) Auburn,MA 01501 NEXT TOOSOLAR BREAKER) BELOW PV BREAKER) Phone number:(888)878-4398 DIRECTORY License*:B-940672 Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means,if not located at the same location.(Plaques shall be metal or plastic,with engraved or machine printed letters,or electro-photo plating,in a contrasting color to the plaque.Plaques shall be permanently flm,,A SOLAR WOLF attached to the equipmenq or in the required location using an approved method that is suitable to withstand the :' ' '"` environment to which it is exposed.Plaques and signage shall meet legibility,defacemet,exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). r - - INVERTER If applicable METER © '] PV SU&Y 'SUB-PANEL' - MAIN SERVICE B- ANEL •if applicable AC PANEL DISCONNECT INTEGRATED r if applicable O ® •if applicable O lO�_�DC DISCONNOECT PV ARRAY 1 5 F9R Mg,- 0 10 -- 0 012 10, MARKINGS,LABELS AND WIRING SIGNS A.Purpose:Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter,as these should not be cut when venting for smoke removal B.Main Service Disconnect. 1.Residential buildings-The marking main be placed within the main service disconnect.The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. SYSTEM 2.Commercial buildings-Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated LABELING DETAIL 3.Markings:Verbiage,Format and Type of Material. a.Verbiage:CAUTION:SOLAR ELECTRIC SYSTEM CONNECTED b.Format:White lettering on a red background.Minimum 3/8 inches letter height.All letters shall be capitalized.Anal or similar font,non bold. c.Material:Reflective,weather resistant material suitable for the environment(use UL-969 as standard for weather rating).Durable adhesive materials meet this Drawn by: Areg Aghayants requirement. C.Marking Requirements on DC conduit,raceways,enclosures,cable assemblies,DC combiners and junction boxes: SolarPapennork.com 1.Markings:Verbiage,Format and Type of Material. supportebsolarpapenwork.corn a.Placement:Markings shall be placed every 10 feet on all interior and extenor DC conduits,raceways,enclosures,and cable assemblies, DATE:06/04/2021 at turns,above and for below penetrations,all DC combiners and junction boxes Priv.Nun. b.Verbiage:CAUTION:SOLAR CIRCUIT Note:The format and type of material shall adhere to"V.V-3b,c"of this requirement. James Wolf c.Inverters are not required to have caution markings e•ropfly new.. I.Marking is required on all interior and extenor DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects. 24 Gooseneck Rd 2.The materials used for marking shall be reflective,weether resistant material suitable for the environment. Yarmouth Port,MA 02875 Minimum 3/8"letter height;all upper case letters Arial or similar font;Red background with while lettering. °rqi 3.Marcking shall contain the words.WARNING:PHOTOVOLTAIC POWER SOURCE. PV SYSTEM AS INDICATED 4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated PV 3.0 N o° LEGEND ri �`, MMMain Meter MSPMain Service Panel PVSPV Sub Panel _ ��/ AC AC Disconnect sW h/, E. qa • . I D yece� AL ! • 0 SCALE: 1/16"=1'-0" a \ \ 17 '-1 • • \ <\ CONTRACTOR �`\a• `• • • ` �. • • ••a! ••• < $otar Wolf Energy ` t • • a , !``` a ` Address: A 1Nashington St. • • • \ , ds 1 0" Aubum,MA 01501 • Qo • Phone number:(888)878-4398 ( • , • • , ! , ` • • • , , `la • , • �k ' License#:&940872 • /, • . • i ! a a • • • a • a I • • i ;\ PROPERTY LINE • kkkkkkkkkkkk.k k kk kk k iiiiiii6H);, ii°:: kk kkkkkkkkkkkkkk Nkk.\.*:\ ` • •• • • • ` • ! \1. a 4 o w.w.r a !$ SOLAR WOLF • \ \ , ` • \ a \kkk ! 4 Satt llke./\ ' . a • • ! , " . a a kkkkkkk • a a ! • •/' Air kkkkkkkkkkkkkk 25 • • , a + , • • a `/ �• •• .` • • a 4 PROPERTY PLAN • ` ` •/•/ Drawn by: �• •` : i ` t •• ` •• is is • Are9 Aghayanrs kkk " k k 'Z.-3" • ` / SolarPaperwork.com • • a support6bsolerbbAblwork.com \ • • ! , a DATE:06/04/2021 • y James Wolf It • • 24 Gooseneck Rd • • Yarmouth Pon,MA 02675 PV SYSTEM AS INDICATED PV 4.0 MODULES ON ROOF DESIGN CRITERIA POINT LOAD CALCULATION PER ARRAY Prior to the commencement of work,the contractor shall verify the existing roof and Solar Modul Modules: Module Weight(Ibs) 42.9 framing conditions.Notify support@SolarPaperwork.com of any Discrepancies 30 #Of Modules prior to starting construction. Rafter 2 x 8 @ 16"O.C. 39 Prior to the commencement of work,the contractor shall inspect framing for any Attachment Max Distributed Load:3 PSF Total Module Weight(Ibs) 1673.1 Plywood&Building Felt locking Rack Weight(Ibs) 334.62 damage such as water damage,cracked framing,etc.and notify DF#2 Total System Weight(Ibs) 2007.72 support©SolarPaperwork.com if any issues are found. 1 Layer of Comp.Shingl 2 x 10 #Of Standoffs 122 These Plans are stamped for structural code compliance of the roof framing Max Span Between Standoffs(in) 48 supporting the proposed PV installation reference only.These plans are not Loading Per Standoff(Ibs) 16.45 stamped for water leakage.PV modules,racking,and attachment components Total Area(sq.ft.) 702 must follow manufacturer guidelines and requirements. Loading(PSF) 2.86 Attachments to be installed in a staggered orientation to properly distribute loads. Collar Ti 2 x 4 CONTRACTOR Solar Wolf Energy Address:771 Washington St. Auburn,MA 01501 Phone number.(888)878-4396 ` ` —-- -- License#:B-940672 0 ATTACHMENT 1 . RAIL 1 "ft.') SOLAR WOLF \J _-——--———--—. Rafter 2 x 8 @ 16"O.C. �� �� J.* 1,,,,- inc. `� I Ilk i FAST JACK ATTACHMENT DETAILS _Z—` - / 3/8"X 3/4" —` ARP'. SS Hex Boy 3/8"SS '— _�/Flat Washer `=` �" `ill_- I/ *-41 1 La er of Come.Shin.le /i�,��a'• dill,. C" *. `i; ��► ATTACHMENT 4 �8 LAYOUT ,i' "4!'- i8 Drawn by: s-`W• i ,�i♦ Areg Aghayants 5/18"SS Lag Bolt Min 2.5" RAFTER -- t�� SolarPaperwork.com Embed into framin•Member _ �!-,4 8 supportasolarpaperwork.com `� DATE:06/04/2021 Threaded Fast 4. 24 Go' ack Base James Wolf 24 Gooseneck Rd Yarmouth Port,MA 02675 Prowl sux. PV SYSTEM AS INDICATED PV 5.0 X-Series:X21-350 BLK X21-335-BLK X20.327-BLK inPOWes.ReSidential AC Moduli, 0 - SUNP WER AC Adel fmndsre IC.'6 ACRX5-96,CAI-US) .243VAC •PSita.,icrc X-Series:X21-350-BLK I X21-335-BLK I X20-327-BLK 111 ) CONTRACTOR SunPower Residential Sol ,,, Solar Wolf Energy Address.771 Washington St. AC Mocule Aubum,MA 01501 Phone number(888)878-4396 Licenselk B-940672 filailt specifically to,use with the SunPower Equnox'5ysterh,the only fully ,ntegrated sol i ma n<I eognect env ne ered anti warranted by one manufacturer SOLAR WOLF ,nc Maximum Power.Minimalist Design. III 4 0 7 !houstry ieadng efficiency meal,more gamer arid sarongs per available space With fewer modules required.,,1 Lii 1 t;,..,' imomr===ximmoupum hititiitamitaarwerterh,wars otairnore. l Highest Lifetime Energy and Sayings. real Wtand conditions like parttat shad e arid high ternperatioe - '' 3 ',''''"-` •FCC Pet 15 Cass 0 •c..150000ciasca .(Mk:SA-C.2n NO 1071-01 •C.,,,,le,11 AA.175,5.,1 Fundamentally Different, -- . And Better. I ested Operatin:Conditions •a Lsted P.,f.i.od 910,kr,irp prr,, . Enables Instaiatlan NI arcordyse...,0- •NEC SO 6.(AC.V/47d...11,0 111111 iC-'r" •fiEC ca '.- 0 __,,,,,,WAka.,.....-and,.,,,,,,, , ' „,,, tio.2 gaga Shistsbror,VILOC-1,....,le tie array •NEC OP 15.0 Confiertors,ESP 3 gii•Fii n reter•used.01 11,1511,1o,nt . ,, EMEMMMI=E21111111111.11111111 fur 27001 •Maxi.lie ground,ng 010d heal SunPower'Mori ase ^Solar COI Years et operation •Ciass A ere rated •El:00;es n.ghe.7..0 cie0,../ v.en,..ed wni,,,,,r.c... MOIlki,e5.,3,40,- +-- -..._- 0(k730• •Enangmenta Patk-ig Ocku,r . •Rani fa eau tree, •L-.0-14,-hed rel,,,K,My a• Pdrerlted BOW metai,,,,,, Best Reliability.Best Warranty. Fran.. _ Class i bfiak axg.rea elie.,-t - i n rent itieltial antsed deg.., around ..., .. ,,,, if-ites ‘1.1.90,5(19 5 kg ..... . . ......... ......_. . .. _ -a MODULE iteremseekded Mgt itte...; 1 3 n 133-italic, ,,P,,,,,,i.e...r100,4D...,pr oven TO last That's Mackie Spsdng 0., 1 I why we aano behind our rpodule and rnicroinvertec ,SinOolver MOViMnpfrtotl.a m.o.,.....Ir.sane... DATA SHEET!. ...,•.....1”It 1...1".61.0,,,Vre.......,^t...,,,,-,. mth the mdustrys oest 25-year Combned Power and aurgtaransnanaPPSins.aismesivervaearttaistniceriags 4.ews,nig, mouukawgesana•1010• 00.1.1.Pilore 2071 Product Warranty,imitating the highest Power Warranty ,aasateinwarautaa..whountionixelksainotrot•;0,..r.ear....s a...a t, ,,colori•inwailAya-mai.etor,Nartfoth,4,,,,m3",YromPtme, Alig lo.6,1 .".'••• Drawn by NaglAnt 3015,CanIpOik.t.,ccal SueVoww.......lega....,..eaonerwl. Amy Aghayants •— , ,JatedMicromverter eve:-.-ol: I ' Ig : 1 .F.,,,,,,,..e.,.4 20.4.40 sel.,t r,,,,,e .t.3.,...t rad,pv.,0ex,,,,,, tommqvcrevs.3.0,6,10..A.,nstas..0r0...a5100,la 1,ro.idurrn.0.... 1•1,... SolarPaperwork.com 5 stantiod,rat Cmokartst100nwrtra.....d.,no.A+,11 5 31Ct.NRELuAr..1.0,, supporlbsolarpaperwork.com •integratee wee management. -14 -' gnaw a 1.6 rare,LAC.f,enil won.,Ad ix.,..tgent.Xycts,texavutanthe 1 ' DATE 06/04/2021 I apid ithroo., .3 lira 01,, 4,: ,,,a Preyaci tallIO• Engineers,:aud qUhr acts by E 1,0.0. *nee,<,,,,,,...,..“...kc.rw,-.,.1,,,,, ,,-,.-.,. James Wolf i.,-,',,,,,Nor-,1„des Prop.,Hiram b....V.' ,' : Ei)......- iin year SUNP,.. WER 24 Gooseneck Rd Yarmouth Pod,MA 02675 Yoars crd op..,.... . , p•pr.ct ,,,... PV SYSTEM AS INDICATED Oatasheet • D 6.0 a s4� "^� d�ax Pt. '«"`�;• :`i.•' a. :;�,zz :.s1^„ .t . `'s .„ f • r a t' ; a , ^ r CONTRACTOR aggiV . -. . - SunPower'' InvisiMounfm I Residential Mounting System SunPowpr'irmiciMr )nt''m I Residential Mounting System Solar Wolf Energy Address 771 Washington St. inN,oMount Cernsot tents Auburn,MA 01501 ample and Fast Installation Phone number.(888)878-4396 •integrated moduleto.ratl groundini<. /lr.."_ License#:B-940672 •Pre assembled and and end camp: lOr•Lrisc m width dth fapto,easy� err+erz n .. • Mldnamps�ndlhfaclAtdtcsconsist en4eve+, ;'?. „� '^t .,...r; ��, SOLAR WOLF ITIC :mule spacing -- III. 111111 •uL 2703 LISed tnteg•ated grour+ding Flexible Design _ •Addresses r:eary all sloped re9denital roots "" I •Design Inlandscape and portrait with up to s' r., raa span •Pre-drilled rails and rail spice "` x.. •tots ral:re,e.3yr,hctadPman3Fernent rr Customer-Preferred Aesthetics ae; •et mcsJrcle and+l1 mounting aesthetics Elegant Simplicity pr,w.. :wpv a:wracw We{ .am t nit• •Bestirs class system aesthetics 2,I bolt +wto i,nm omamrneaa ssxw:;ec,c a;�; •Premntn.bwprU+te design SunPowent InvisiMount'"is a SunPower-designed uwi nut .no-+, NN e013 SSXN m a .a:.IuR t MO4 l 7 bolt u..r Clrrygn•n .non i C sr RrP •Black anodized components rait-based mounting system.The InvisiAfount system avi'" .-- 100t.,.arwn •Hnklen mid damps and capped,flush gmn'6;1. Iss,o wr�s ra+•,1,,,._ _ -. ... i •u,.. addresses residential sloped roofs and combines*aster end clamps k''' " I tea•. installation time,design flexibility.and superior aesthetics Part of Superior System The Ira s:Mount product was specficai:y erwisoned and •9ulo for use with SunPnwer DC and Al'modules re i-s. _ •2s. arppuct.•e-a,, engineered to pair wth Sunpower modules.The resulting �— I •8es1.in class s,stemretiabllty and aesthetti; a. j �,,,,L, ,+kttl3P5 sK" . RACKING system-level approach amplifies the aesthetic and tn„r1A,,,p 1 I _ •optional rooftoptransalonflashing,rail 1 'a'03LI DATA SHEET maned(box.and woe management rail dips installation benefits—for homeowners and for installers. t i en rca:u:� •Combine with 5unPower modules and 100: _._._.... +fra:s.lke WM...,+4W,.vf sail bit l Drawn by' Verne,rx.rrwrd seo mr.a i ■_ keg A9hayanrs upin retort SolarPaperwork.com tent perer to ratsru+,,me+v rrware,nn,uactve,xam•ercatm supportIDsolarpaperwork.corn .f sunpower.com i I -"e"' �•"U` I --- DATE.06/04/2021 sr U) •wn: w t ri6tlCau a`"m .;,«ws .e m.. .e mane spm-,...varea.a..enyp.s:..nee a•.pu a..., James Wolf e, .acg..a uraav c.,ry.arulosln5aw as a.,a*.e.,sc:auw,o-.vm cesr,w.. c:•, u r,reururongneo;rp,*n,..,r+m .+,.naeaorv.:0pe..e.wx:s,.aw«:n.I.a 5.op>.r+asun.7e67. v:,prwn.;ar. 24 Gooseneck Rd �'.-�",x.. ,...v..., ,... e.,•.._:..,� ,,,+, ... e+ ,,. ,e ..,.,,ter,.,.. . ,.-.,, sxK'*__' Yarmouth Port,MA 02675 A MUM!,eel SUNf L R SUNP WER' Pc WEp. PV SYSTEM AS INDICATED D 7.0 Installation steps for FastJack" Third Pa'"ty Fast_lack l-• and FastJack°Flashing � uS•a <rCt_r i,elernrehrY6wn CONTRACTOR U12703e a0 Solar Wolf Energy 1,380 Toted Address:771 Washington St. Wnrerl'rne� FastJack Structural Roof Attachment e�r. Auburn,MA 01501 Phone number:(888)878-4396 with New Aluminum Flashing and Collar ktzI ;f may. License#.B-940672 "See 90 second real-time complete stp1:0r11mitap•dt hole wlth Step 2:Mark him knee using templatei��61 SOLAR WOLF Step 3:Trim and remove shingle. , g p Install video at 3116•carbide bit and limber crayal For high wurre use Are.TutfoSheer k. "'0r t www.prosolar.com" 'hnpD"�"" ar +eYraina-ten Fesi j eck 65 n.s 4 m FeYJw E.Soinerr Pod er E-200 Port JEX a r,.rap Foxtrot*'E.S•ep Port OfJE- h)bAioaPba a`!, Stop 1.Drve lag screw through Fait- Shop S:Side fntJtdrBhashingg wiM cordless impact gun under shingle Stop a:Tighten Feat x@ poet base Ste base Festhca E Sin Flashing a Color Part 6JE•P wet!seated ll Benefits ofFastfack•and Fastfack FlashingTM •Lowest cost highest quality •Solid aluminum post prevents water fbw \ •90 second install time through post into roof ., : •Includes Lag screw and ProSolar rail •Heavy-duty 0.032"aluminum flashing attachment hardware thickness •Black powder-coated flashing and collar Step 7:Apply 1r4"bead of sealant Step 8•Dane Step 9:Attach ProSolar RoofrracE IGeoco 450ot and compress with of and clamps ATTACHMENT professional The Fastfack Design Aluminum collar SOLAR Patented,single lag bolt design makes cJq For use with t inch post diameter DATA SHEET products* 1. t the easiest to install attachment Pro Solar®astJaclR�E-Se ies ' -`f ^ •2 piece design allows flashing to easily a FastJack E-Series and parts Drawn by slip over base,prior to post packaged separately Areg Aghayants (805)486-4700 "' ` �y—` SolarPaperwork.com ( ae6d -47 s •Flashing design prevents water ,„r` ' ,a• • See online installatbn guide for supportebsolarpaperwork.com ingress from any direction further details DATE O6/042021 1551 S.Rosa Ave. r w Oxnard.CA93033 .um. •Made in U.S.A.,American Recovery hastJacke patent#6.360.491 and Reinvestment Act(ARRA) James Wolf View more info on our Sharpie cutting-F prate Malco ailTurboShear drill accessory WebSte at: compliant Pan#TEMP-FJE Pa„#A-Mako map,,,,, www.p ro sot a r.co m "°°•'""°"" 24 Gooseneck Rd WWW.pmsOlar.COti1 a Yarmouth Port,MA 02675 Prolessieral Solar Products Inc Feb 2015 Fastjack':is reg,stered trademark and rounmed under Pat 46 35C 4P 1 F.au Scale_ "As bad lasted wyk ProSolorSe R.M.19 System PV SYSTEM AS INDICATED D 8.0 v , .ti•- • r n • 4 _ >r x r CONTRACTOR Sur Power InvisiMountTm I Residential Mounting System r i rill'n,^ter InvisiMountTM I Residential Mounting System Solar Wolf Energy Invisi41 u'mt rofirxrr:ire. Address:771 Washington St. Simple and fast Installation Auburn,MA 01501 • integrated module to-railgrouodng a#_ Phone number(888)878-4396 License#:B-940672 eassemt led endued end damps ailljr wttating rr d r.amp fa c14 easy placement - . Aid clamp eaclth far utatesconStstent.Net, 5:pro - hoc SOLAR WOLF i:dine spacing • . • i 2703 r_sted ntegrated grounding Flexible Design 1..... jilt •Addresses nearly a4 sloped residential wIIial roofs •Design In landscape and pa,.raft with up to 8' - °,C.,ar c R41 me Pad Spite ;ri%Spdrr, • F9ren 4pn Gro:::'ra.g SKr • fe-drilled 4115 did tali splice • :33115 made eas'pbslade management ,'r :... _ M:n:i4n Oak 01Fie...less 0eee 3(10ae55 53gr22en terrrper.ure .,3e C to 90•C(-40•r to dart E,:c 51.53 Ora.anorvertaktorrooter 5330 5t4es 1,0g13a3 00605$5 Customer-Preferred Aesthetics aaaa ,x ak es '83 s Ma x WN1 ! oerxr Pa rkxv-5 51 module ar:dal mounting aesthetres Elegant Simplicity P.ai sauce 43.5nrstro 8.30v13000vares Irk00r lvozrrr :St-In-C.-rS�,nntemaesthe0.K5 .n 5cv Mad- rt.zrrm Yra tNgo t• , SunPowef0 InursiMourt'5 is a SunPower-des-designed ii 'y„ `Mm i ("Srr9B4,303 ,- I 1 emium,l„ovl-pidkle de9gn g :r•aa •i loo sa sn ekrter el05 -per. S 304 n.Aln& ¢de'r4Rer;ug r -g(-l5 ax, .co.^i>DS! sr,gil g1010 Y /4 Nr,r n,ack.malted components rail-based mounting system.The invisiMount systemiir^",°^ m+. i i ry uleta1e0 to°rSO dirt reecho.' . .ridden mid clamps and sapped, faster F , iss x3ww s3o+M6 urns sg ze:r - "'PS "� addresses residential sloped roofs and combines end clamps .r0,n on I aNtiinf M-:sae Paris 5C(0 nor, installation time design flexibility,and superior aesthetics. Part of Superior Sys ern The In3nsiMount product was specifically envisioned and •7u:lt for use with Sunp ower DC aid AC ro ies „ .in "a mr 25*e.v engineered to pair wth SunPower modules.The resulting 1 a:'.m bl,fcir SaliW I n warfNR,,, o° IrDClo CS system reliability and aestheiml Soo,rI n Ipnunavtxdr±npvarsltbn uasning rain system-level approach amplifies the aesthetic and r�auaPro ; 89.1b1 i----- --- uk tine u.ec ._ MONITORING SYSTEM • :nountedi box,and wiremanagenent rail dips installation benefits—for homeowners and for installers. esnae '`---- "` ;:,.-. DATA SHEET •r aRlbine with SunPow'er nodules artd Pa' t- Mourn!urmvn.dr: Mv,e:r;sa Drawn by: .:Isms ucuvrrnam -atn ivr•r1 Areg Aghayents '` kr, 'MO St SolarPaperwork.corn sunpower.corn ,.,. 90;ur Pzter nrroMarar^v,ev d nrmrnx.: a t.-.^ersar.or. - supeorttisolarpaperwork.corn DATE 06/04/2021 4fisib� 0 ! K s.yr r. James Wolf 24 Gooseneck Rd Yarmouth Port,MA 02675 natasheet SUN P WE R• S U N P W E R• PV SYSTEM AS INDICATED SUN YYL D 9.0 '� ® DATE(MMIDDIYYYY) AccoRe) CERTIFICATE OF LIABILITY INSURANCE 04/23/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT CHRISTINE PRODUCER NAME: --- LEIB INSURANCE AGENCY PHONE 508 792 0411 ac,No JAIL,No,_Ext): —� t L 537 PARK AVE ADDRESS: WORCESTER MA INSURERS)AFFORDING COVERAGE NAIC# INSURERA: NAUTILUS _- INSURED INSURER 8: SOLAR WOLF ENERGY INSURERC: — 771 WASHINGTON ST INSURER D: AUBURN MA INSURER E: LIBERTY MUTUAL INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR'�. ADDL SUBR I POLICY EFF I POUCY EXP I LIMITS LTR TYPE OFINSURANCE LEISR WVD POLICY NUMBER {MM/DD/YYYYI (MMIDD/YYYY)GENERAL UABIUTY I EACH OCCURRENCE 1 $ 1,000,000 DAMAGE TO—RANTED X COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence) I$ 100,000 CLAIMS-MADE I X OCCUR MED EXP(Any one person) $ 5,000 N NN1119891 06/08/2020 06/08/2021 PERSONAL a ADV INJURY $ 1,000,000 { GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 I POLICY I I PJFSROT- I 1 LOC $ MBINED AUTOMOBILE UABIUTY (EOa accciden�SINGLE LIMB S ^'ANY AUTO BODILY INJURY(Per person) $ ALL OWNED I SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS NON OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS (Per accident) I $ UMBRELLA UAB I OCCUR EACH OCCURRENCE S EXCESS UAB 1 CLAIMS-MADE AGGREGATE $ DED I RETENTION$ $ WORKERS COMPENSATION I TORY LIMITS I WC STATU- I T AND EMPLOYERS'LIABILITY ANY PROPRIETORiPAHTNER/EXECUTIVE YIN E.L.EACH ACCIDENT S 1,000,000 E OFFICER/MEMBER EXCLUDED? Y N/A WC2-31S-614936-020 08/10/2020 j 08/10/2021 1,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE$ II yes.describe under I DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 I DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (Attach ACORD 101,Additio iat Remarks Schedule,if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE YARMOUTH TOWN HALL THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 1146 ROUTE 28 ACCORDANCE WITH THE POUCY PROVISIONS. YARMOUTH PORT, MA 02664 AUTHORIZED REPRESENTATIVE /I- rr', ),- a . I lI ' 'll _ ACORD 25(2010/05) ©1988-2010 1ICORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD