Loading...
HomeMy WebLinkAboutBLDE-21-007529 $ Commonwealth of Official Use Only tL. ,A' Massachusetts Permit No. BLDE-21-007529 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked jRev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:6/27/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of has or her intention to perform the electrical work described below. Location(Street&Number) 67 MERCHANT AVE Owner or Tenant BRENNAN ELAINE C Telephone No. Owner's Address HAMMOND CHRISTINE L, 67 MERCHANT AVE,YARMOUTH PORT, MA 02675-2238 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(18 Panels 6.03 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above in- � No.of Emergency Lighting grnd. grad. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons K\1 No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND ❑ OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: SOLAR WOLF ENERGY Licensee: Kyle Zuidema Signature LIC.NO.: 22593 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 771 Washington Street,Auburn MA 01501 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 00_ ( 2'(167) t � , �,7SZcir RECEIVED-1 Commonwealth.o/Mae3ach.aufb Official U ill ly J U N 2 5 121 1 1 ���� � cc�� c7 Permit No. �_ ..J 3 .Jieparf»unf o`_tiro rwrcr� Q ILDING DEPA'TPAENT r ;a' Occupancy and Fee Ch: ." __.—____A ----- . ' BOARD OF FIRE PREVENTION REGULATIONS Rev. 1/07) (leave blank)." lank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 6/22/2021 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 67 Merchant Ave. Yarmouth Port, Ma 02675 Owner or Tenant Chris Hammond Telephone No.508-398-6694 Owner's Address 67 Merchant Ave. Yarmouth Port, Ma 02675 Is this permit in conjunction with a building permit? Yes ❑ No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No.5792336 i Existing Service 200 Amps 120/240 Volts Overhead El Undgrd n No.of Meters 1 New Service Amps / Volts Overhead ElUndgrd E No.of Meters Number of Feeders and Ampacity • Location and Nature of Proposed Electrical Work: installation of a 6.03kW roof mounted solar array using •.. 18 SPR335W panels with built-in microinverters. Installing an empty meter socket for SMART gen meter. Completion of the following table may be waived by the Inspector of Wires. vi lb Ceil.-Susp.of Recessed Luminaires No.of Ceil Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above In- -No.of Emergency Lighting No.of Luminaires Swimming Pool Above ❑ grnd. ❑ Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones z- In No.of Switches No.of Gas Burners No. Deteon and Initiating Devices i 1,1 No.of Ranges No.of Air Cond. Total No.of Alerting Devices t' Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices Municipal No.of Dishwashers Space/Area Heating KW Local❑ Connection ❑ Other No.of Dryers Heating Appliances KW, ecurity Systems:* No.of bevices or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent a Bathtubs No.of Motors Total HP Telecommunications quin No.Hydromassage No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 8911.80 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND El OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the infornr,tion on this application is true and complete. FIRA1 NAME: Solar Wolf Energy LIC.NO.: 18640 Licensee: Kyle Zuidema Signature f L �,./.--- LIC.NO.: 22593A (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: 508-839-2222 Address: 771 Washington St Auburn Ma 01501 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. C... tot, - O„ p 072 � l d-.I ma m L p tRo¢ . EC rpo,- . mWuEQ m cE LL N Q 9 o m O ..J o€ cf O EYm2 Cr 'c G L m U t m o 0 jJZ �iY U ti.,}J N -1,i,' .` y rU N N W Ct o d 5 i ,. :• r O a IRR 1- m-a-m"' E W w , U 6g8W8 @ $$9 v��za ? Lu 1- ,o., `-OZu c o.o.”m U Q b- ,... $ 'UO< te Odd00 > N x H J y a o w 00 0 0 0 0 0 0 a', O F w O F' N ,i < vi m n m o; }2 O tan Y W~ Z Pi p Z a a a a a o 0 0 0 ‹m mm �w 0 NNO co 20 > F- WE a Li r 0 ¢ w o 0LL{��wc6y. °Gwcw>tw9 0 �2 LL Zu�2 aO 7O0 00 O W W a ve 0z08,mm'mUxa< Z 00 N 2W J amy OLL z&Itio W g j z Z O N u=i a y 0 °U Z�,co o o 0 m 3 Z Q w w F w L Q V V y Z 1}Q@ ufluV1w zg��oEEEtOow a z3 WH ZQ_1pmm.2?IDAWZ8 uj uj Ma 2 W F0�2__S. O.V0 OW. a. U I= fAZ(ozzm _1 0)7I�uL W W 0 W a a 2 2 a Z > w O w N N N N N¢O U V(..) _ ~ J X Q Q O DUD 2 _ > ¢ O V F- O 22 «_, u; OQ W ro� W w222 m 00W F- N m w 0 a a 2 o f U' Fa� ¢¢� m �N o o, C y N_ m .t 1 O u, > G m aci m`G° o� c% c.U `yyoc0,2-@ S > ego � Q t2 t a N II liii UI HI!jtti C C E'C N yog = JI I O� Zt oe = a '9-l gE a cy n, 3 u mC Em , . aa,eo F.- ac coi N '� O. O.E k O O O o c N a a, j g N y N Zj O'O, Nj N c '0 N y O' a 3 Ez,ey„, 8 maEam Gnt caa aaa % - a`, a u m -, 'a voa e U u€ R, _ �'c E... �,m ° co mans m E ° U o jNQ 7 y N, ,e= q G �� ,=�`°Co p>.0?NC O� > > Up O ,;",pc OO ° 2�'cc o`o`o 'i�0 w o'mu e °i t� v�aQN mc E"a m� tc m _ aZd.cG,h 2_ Oyv =2 >_ " g0 Focm ;- 2 , my p O.Gu a ham'.1' HcQcea,00,2mm.c_$ d, O '„ag ‘8tG=huE_ ac a$ eao13g•_ ycy° Eoyc % cm°= yz L82@uou : u=- '2,0c o n0S-6 ? �omEag,u - ccgtot oa . 2'aM w czitSc 2.aimci. aGmvcoaiov`, ,, m eg�TEaom t. a`oat e ` c�c, Qnanm . uoccNa 8.22.2 .O _ O maatm u Dt ' � Nm3'y °E mmo. c. aa w'�c gJ ` g -"o''V't2_ , Q ~ .g2tU zZ Eam� =CCV ; LNmmNayHaaD N1;1>i, y!t82 m— �Eo`.s2, 8 E O ODCYoTB. ta.5.gOe , o Eay,, ° >.aEE-2 .y2N�.,„ otQmEE -A.TQQmgTm !.aom ` Ta > aGyEO n L1 ; ce > ,mo,4%Q1 Ytn cG 5y e O o ,267.6 �? 2t tooz 32� omtCg2tsz,55.=3.—§. � h aS¢ na ¢¢E w ¢aUaO,0.. .. 0. 00vE _ y anyE = _ 60 ofof , ui K cO o; Cl- N ci v ui ui r.: ,o of z. o SOLAR MODULES INDEX rit::;;' 18 SunPower MM (E)Main Meter Model#X21-335-BLK-E-ACMICMSP (E) 200AMainService Panel INVR TER TYPERMS (00 100A PV Sub Panel INVERTER TYPE TEG PVS6..(N)PV Monitoring Systeam W �.,- E 18 FACTORY-INTEGRATED 270 90 Model#X21-335-BLK-E-AC(240V) MA (N)MA Smarth ;v, D� GenCrDisc Disconnect ct AC (N)30A AC Disconnect 1101. JB N)EMT Junction Conduit 180 FMT Conduit SCALE: 1/8"=1.-0" Setback I CONTRACTOR Solar Wolf Energy 4" 0 Address'.771 Washington St. Auburn,MA 01501 O Phone number:(8891 878-4396 License#:B-940672 01111111, > �` SOLAR WOLF a 50: '" N U n 1111117 • • • O SITE MAP&PV 1 �• LAYOUT �0 • 6.. �• � \ Drawn by: Solar PV Array • Areg Agnayanrs 18-SunPower 335W Modules • suppoSolar apenvork.com 18-Built-in Microinverters support(dlsolarpapenvork.com JB I DATE:06/142021 Pitch:24 Deg / _ Orientation:247 De. i" PVS6 Chris Hammond 8 Elaine Brennan PVS AC MA 67 Merchant Ave Yarmouth Port,MA 02675 NOTE: Conduit in attic shall MSP MM PV PV SYSTEM AS INDICATED be minimum 18 inches from roof sheating PV 1 .0 Existing Conduit (E)Generator NOTE:Service Panel is center*Kt Add new 705.12(D)(2)(3)(e) / /(E)Auto Transfer (e)A Connection at either end,but not both ends,of a center-fed f Switch board in dwellings shall be permitted where the sum of 125 I / percent of the power source(s)output circuitcurrent and the rating of the overourrent device protecting the Dusbar does not exceed PV MONITORING , 0 i j 120 percent of the current rating of the busbar SYSTEM V Imo_ (4)#10 ASIG THWN/THWN•2 - ( 1% �/ (1)#8 AWG GND MAIN METER T 3/4"FMT.20 FEET PV DISTRBT.PANEL CENTERFED 200A I�4" t00A,120/240V, MA SMART Viaow,Localxe,L.wled Swonnea �eoxt NEMA 3R GENERATION METER to or Lea rrom udlay lA.osr MAIN C/B ��I EXISTING n rowan 400 KW 120/240V 304 tzorz4w 200A MAIN INSTALL 15A PV / NEMA 3R Non Fuwd Aa 0ieaonneet --_-"" '� �� �, 2-POLE CB SERVICE tL:T / � �i lJ INSTALL 30A 2P CB(PV) ------ PANEL .._ a C•.n. e.n. O.7 INSTALL(2)20A PV (/ INSTALL AT OPPOSITE I IJ 120/240V, I �•:� ��•" •••� -POLE GB END OF BUS FROM 1P,3W CONTRACTOR g Ill •UU as MAIN FEEDER CO rc uu eno un• �� 1••• 2�••• g •• �_ Solar Wolf Energy 0 1 I Address:771 Washington St. "Ivy ��/ �W / y 11 PhoneAubur number:01:(888)01878-4396 _/- License#:B-940872 III P t fi d I m DeTe-n, Oral (4)*10 AWG THWN/THWN-2 GEC x uu u•• (4)#8 AWG GND (3#10 AWG THWN/THWN-2 •• •• •••• SUNPOWER TRUNK CABLE ) (3)CO AWG THWN/THWN-2 '''"a'a' iiii ••• (2)#12 AWG PV WIRE 3/4"EMT.5 FEET (1)#8 AWG GND (1)#8 AWG GND /3)CO AWG THWN/THWN-2 '..r 5 SOLAR w�f' o • •• '}/g"_FMT 9 PT in°. h°: nuu #:i=e_ (1)#8 EGC ,EFT_ 3/4"EMT.2 FEET 1)#8 AWG GND \*irZ•'o flie* - • FREE IN THE AIR /4"EMT,2 FEET (E)GROUNDING ELECTRODE SYSTEM 18 SUNPOWER 335 WATT MODULES 18 SUNPOWER INTEGRATED MICROINVERTERS PV ARRAY RATING WIRE SIZE CALCULATION BRANCH CIRCUIT-A BRANCH CIRCUIT-A Number Modules 9 Type Sunpower AC 335 Watt SPR-X20-335-BLK-E-AC Number OF Microinverters in Circuit 9 Type Sunpower 335 Watt AC SPR-X20-335-BLK•D-AC ypOutput Current Number Microlnverters (A)Microinverter Maximum 9 Factory-intergrated Microinverters (240V) 1.31 Location Watts STC,(Watts/Module)9•335=3015 Branch Circuit Total Current(A) 9•1.31•1.25=14.74 Array Currents I-SC N/A A 1-MP N/A A Breaker Size Per Branch Circuit(A) 20 Module Voltage V-OC N/A V _ V-MP N/A V BRANCH CIRCUIT-B BRANCH CIRCUIT-B Number Modules 9 Type Sunpower AC 335 Watt SPR-X20-335-BLK-E-AC Number OF Microinverters in Circuit 9 Type Sunpower 335 Watt AC SPR-X20-335-BLK-O-AC YPOutput Current Microinverter Maximum (A) Number Microlnverters 9 Factory-interg rated Microinverters (240V) 1.31 Location Watts STC,(Watts/Module)9•335=3015 Branch Circuit Total Current(A) 9•1.31•1.25=14.74 ELECTRICAL 1-LINE Array Currents I-SC N/A A _ I-MP N/A A Breaker Size Per Branch Circuit(A) 20 DIAGRAM Module Voltage V-OC N/A V V-MP N/A V FROM)BOX TO ENPHASE COMBINER BOX . Maximum Continlus Current(A)I 14.74 More Than 3 CCC Adjist.FactorDrawn by: 0.8 Adjusted ConductorAmpacity(AJ I 14.74/0.8=18.43 dreg Aghayants Raceway Height From Roof(Temp 39u22=61C) 3 1/2" I#of wire(#BC*2) I 4 Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a) 10.71 SolarPapetwork.com supportFtsolarpaperwork.com Temp.Derate Factor(max.continous current divided ambient tam.Factor(A) 18.43•0.71=25.95 Wire Size from NEC Table 330.15(b)16 I 10 AWG DATE:06/142021 FROM ENPHASE COMBINER BOX TO MAIN PANEL ngip*ini Chris Hammond 5 Elaine Brennan Total Number Of Microinverters I 18 Total Amps From All Microinverters (A) 18•1.31=23.58 Consider Continuous(A) 23.58•1.25=29.475 Rep"Above Temp.Derate Factor(0.91 at wall of the Building)(A) 29.475/0.91=32.39 Wire Size from NEC Table 310.15(b)16 10 AWG 67 Merchant Ave Yarmouth Port,MA 02675 Ambiend TernFactor Per NEC Table 310.15(b)(2)(a) 0.911 MAIN PANEL PV SYSTEM AS INDICATED PV Backfeed Breaker Size(A) 30 Main Breaker(A) 200 Main Bus Rating(A) 200 Total Amps On Bus(A) 120% 200+30=230 <=240(A) D\/ 2.0 "0 LABEL 1 LABEL 2 LABEL 3 LABEL 4 LABEL 5 LABEL 6 CAUTION CAUTION WARNING! SOLAR PV SYSTEM EQUIPPED WARNING! PV SUB-PANEL ONLY AUTHORIZED SOLAR SOLAR DC CURRENT PRESENT ELECTRIC SHOCK HAZARD. WITH RAPID SHUTDOWN ELECTRIC SHOCK HAZARD. PERSONNAL ONLY! DURING DAYLIGHT HOURS IF GROUND FAULT IS INDICATED, DO NOT TOUCH THE TERMINALS. NORMALLY GROUNDED TURN RAPID SHUTDOWN TERMINALS ON BOTH THE LINE AND (TO BE LOCATED ON (STICKER TO BE LOCATED ON CONDUCTORS MAY BE SWITCH TO THE LOAD SIDES MAY BE ENERGIZED IN SUB-PANEL ONLY CONDUIT WITH DC CURRENT UNGROUNDED AND ENERGIZED. "OFF"POSITION TO I.1...,tt71 THE OPEN POSITION. WHEN SUB-PANEL IS EVERY 4'HORIZONTALLY OR SHUT DOWN PV SYSTEM DEDICATED FOR PV ONLY) 10'VERTICALLY AND 1'FROM AND REDUCE a EACH SIDE OF A BEND) SHOCK HAZARD IN THE ARRAY LABEL 7 LABEL 8 LABEL 9 LABEL 10 LABEL 11 WARNING! PV LOAD CENTER SIZED FOR PV AC DISCONNECT THIS PANEL FED BY SOLAR INVERTER OUTPUT CONNECTION.DO NOT BREAKERS ONLY OR RENDERED UNABLE CONTRACTOR AC PHOTOVOLTAIC POWER SOURCE MULTIPLE SOURCES RELOCATE THIS OVERCURRENT DEVICE TO ACCEPT ANY ADDITIONAL LOADS. RATED AC OUTPUT CURRENT:29.47 A MAX (UTILITY&SOLAR) Solar Wolf Energy NOMINAL AC OPERATING VOLTAGE:240 Vac (STICKER LOCATED (STICKER LOCATED (STICKER LOCATED Address:771 Washington St. INSIDE PANEL INSIDE PANEL NEXT TO SOLAR BREAKER) BELOW PV BREAKER) ON THE PV SUB PANEL) Auburn,MA Ot 50t DIRECTORY Phone number(888)878-4398 License*:B-940872 Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means,if not located at the same location.(Plaques shall be metal or plastic,with engraved or machine printed letters,or electro-photo plating,in a contrasting color to the plaque.Plaques shall be permanently ,r?%.( SOLAR WOLF attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed.Plaques and signage shall meet legibility,defacemet,exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). i INVERTER 1 If applicable METER © O r n SUBS PANES r MAIN SERVICE PV S ANEL �if applicable AC PANEL • INTEGRATED *if applicable DISCONNECT CD BOX DC DISCONNECT O ® *if applicable PV ARRAY ' `0 O 9 4 �O O �O - 0 O 12 ��� MARKINGS,LABELS AND WIRING SIGNS A.Purpose:Provide emergency responders with appropnate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that conned solar panels to the inverter,as these should not be cut when venting for smoke removal B.Main Service Disconnect. 1.Residential buildings-The marking main be placed within the main service disconnect.The marking shall be placed SYSTEM outside cover if the main service disconnect is operable with the service panel closed. 2.Commercial buildings-Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated LABELING DETAIL 3.Markings:Verbiage,Format and Type of Material. a.Verbiage:CAUTION:SOLAR ELECTRIC SYSTEM CONNECTED b.Format:White lettering on a red background.Minimum 3/8 inches letter height.All letters shall be capitalized.Arial or similar font,non bold. Drew,by: c.Material:Reflective,weather resistant material suitable for the environment(use UL-969 as standard for weather rating).Durable adhesive materials meet this Areg Agheyants requirement. SolarPaperwork.com C.Marking Requirements on DC conduit,raceways,enclosures,cable assemblies,DC combiners and junction boxes: support(0solerpaperwork.corn 1.Markings:Verbiage,Format and Type of Material. DATE 06/14/2021 a.Placement:Markings shall be placed every 10 feet on all interior and exterior DC conduits,raceways,enclosures,and cable assemblies, at turns,above and for below penetrations,all DC combiners and junction boxes Chris'"• b.Verbiage:CAUTION:SOLAR CIRCUIT Note:The format and type of material shall adhere to'V.V-3b,c"of this requirement. Chris Hammond 8 Elaine Brennan c.Inverters are not required to have caution markings Rap,arch 1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects. 67 Merchant Ave 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Yarmouth Port,MA 02675 Minimum 3/8"letter height;all upper case letters Anal or similar font;Red background with white lettering. PV SYSTEM AS INDICATED 3.Marcking shall contain the words:WARNING:PHOTOVOLTAIC POWER SOURCE. 4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated PV 3.0 • o LEGEND � — MM Main Meter MSP Main Service Panel 0. ��; 174'-5' PVS PV Sub Panel WE T� — PVS6 PV Monitoring Systeam 270 `� �, 90, — — — — _ v. —v v. v v. ✓ v AC AC Disconnect v. v, v' v. v' v MA MA Smarth - D v v v v v v v v v v v Generation Meter V. v v, v v v, v' v. v v v v v v v v v v. 41 v. to V. v. v _ao. L v v v v V. v v v v v �` 1 P v. v v v v SCALE: 1/16"a 1.C.. I v v v . "" v ... v v v. v v v. a V. v v v. v. v I Iv v v. I v. v v vv. v v v v v v. v. v. v a. CONTRACTOR ,� 10. v- �` v, v v v- v v v- v v I Solar Wolf Energy v, v v. v. v v- v v v. v' v. v'I Address:771 Washington St. 1 v v v w. v v v v v v- v v v Auburn,MA 01501 v v v v v v v. v v. Phone number(888)878-4396 ry v v v v v v v v v v- v. v PROPERTY LINE License#:B-940672 N v v v v v v v v v v v v. v v- v Q vv. v v v v v v v v13 �" v v v v v.v... v v v v # `,. SOLAR WOLF V. v v v v v v v t v v r. v r e\I v v v v v v co 14 '2"I v v. v v. v v- v v v v v v v v v- v v 18 ._9" V. v v v v V. v v v v v v v v v v. v v v v v v v V. v v. \v. V. v M. r a Vv.. I V. v v v v v v v v vvv vv 1 IW. v a vIv. v4 vv. vvvvvv. y vvvv vv. v- vv V• vvV.IV• v V- LLvv v v vY- vvvY• vvvvv. vvv v. vv. v v vvI. v v v I I v v v v v vv11 111111j1i1 ‘.0vv vIv v v v v. v vv v v vvvvvV vvvvvv •3v3 v v v e , v v v v �� ,� v +� • �, —� 9'w' `� �,,, v- " I PROPERTY PLAN , r r v Driveway PVSv.& v v v v v i ' . • v v v • PV v. v v. vl Drawn by: • `. v v M v. v Areg Aghayants v v v SolarPaperwork.CO. v • , �•�•/v. v v •Cv v v. v v suPPORRQsolarpaPenvork.com ^� v v v. v v, v v v -DATE:06/14/2021 v v v v SPv v v ».,4«•••• v v. v v v MM v v. — Chris Hammond 8 Elaine Brennan v - v. v v v.- 67 Merchant Ave \` v v _ �_ 101'-2' Yarmouth Port,MA 02675 P PV SYSTEM AS INDICATED PV 4.0 MODULES ON ROOF DESIGN CRITERIA POINT LOAD CALCULATION PER ARRAY Prior to the commencement of work,the contractor shall verify the existing roof and Solar Modul Modules: Module Weight(Ibs) 42.9 framing conditions.Notify support@SolarPaperwork.com of any Discrepancies 18 #Of Modules 1 8 prior to starting construction. Attachmen Truss 2 x 8 02 18"D.C. Prior to the commencement of work,the contractor shall inspect framing for any Max Distributed Load:3 PSF Total Module Weight{Ibs) 772.2 Plywood 8 Building Felt locking Rack Weight(Ibs) 154.44 damage such as water damage,cracked framing,etc.and notify support©SolarPaperwork.com if any issues are found. 1 Layer of Comp.Shingle. DF#2 Total System Weight(Ibs) 926.64 These Plans are stamped for structural code compliance of the roof framing 2 x 10 # StandoffsOf 38 Maxax Span Between Standoffs(in) 48 supporting the proposed PV installation reference only.These plans are not Loading Per Standoff(Ibs) 23.76 stamped for water leakage.PV modules,racking,and attachment components Total Area(sq.ft.) 324 must follow manufacturer guidelines and requirements. Loading(PSF) 2.86 Attachments to be installed in a staggered orientation to properly distribute loads. CONTRACTOR Solar Wolf Energy Address:771 Washington St. Auburn,MA 01501 Phone number(888)878-4398 License#:B-940872 ei ATTACHMENT RAIL i3� • SOLAR WOLF ems, Truss 2 x 8 ©16"O.C. 4, 0 PEGASUS ATTACHMENT DETAILS LightSpeed Flashing ROOF ASSEMBLY • • • 4----- ® -, .... ATTACHMENT Support Block EPDM WASHER LAYOUT i i ISS011 -j�•`�. Drawn by: II�� fJ� .;, Amg Aghayants 0 �1 1g SolarPaperwork.corn ,1� support{0lsolarpaperwork.com • r\ �1� DATE 06/142021 `1 ., ��• Ca.4w�.. \ '•, , Chris Hammond&Elaine Brennan • Prop.,brow aY0 67 Merchant Ave y �. r i i Yarmouth Port,MA 02675 4r�i i � r i i i PV SYSTEM AS INDICATED PV 5.0 X-Series.X21-350-BLK X21-335-BLK X20-327-BLK — © SUNP WER tl.Yt,ir.,l i X-Series:X21.350-BLK I X21.335-BLK I X20-327-BLK CONTRACTOR aSunPower' Residential Solar Wolf Energy AC Module Address: Washington St. Aubum,MA 01501 Phone number:(888)878-4396 License#:B-940672 Built specifically for use with the sunPower Equinox"system,the only fully integrated solution designed.engineered and warranted by one manufacturer. Flow; SOLAR WOLF Maximum Power.Minimalist Design. r„rg.r 's jaz Industry eadng efl.iency cleans more powet and savings nee available space.With fewer modules required and I •-.:dden microinverters,less is truly more. ,noes,Comfit irons.and Compliance ,1 3mmheac as MiL141r4( 4,30•227a11ueael Non.Pow•tP.nml 350.'. 338W 327W //� Highest Lifetime Energy and Savings. ezd •v.Mi sr Oat f)x .at,4 L 1 .-. ... --.. . C .a>.x,na-..tk t 747/1FE6154) :Na:Je E?em It 9F 2ax 20K U.174i Af taaOuk(ype2 P•e.x.• :. .- 0190E`"C -0 C 0 9NPC n 11E 621091.i IEC 62,732 Na rlwond conditions like partial SI toile and high temperatures.' ' i:ak th va•7 ._.. _ 'f':'''" ,r{CPan 1 Saaes e •^n on bypass dkdes cts W03 Cam e wale03 ••Meg ate]-iidw.leve!rraa,a: .C4hicSFQ22Nd.laJ l.Or 3 wee,Ixan!nttu2t •CA Rule 21(tk 1741 sAr fundamentally Different. in:Ades 4outar and Reach.Pane C.prry And Better. L sune,wer•Xseaas la,to •to Listed Pa Rapd Shadow,Fgipmem° 60% Cpera!v,g Temp .401- es tt{-d0•C to 485°C) '• At ank.+• ° i F Sbs'1 EnaG bCtabdmm acaudarce wan: " mar• NEC ._ NEC690 module{ ism" t _ Idarim. Mat,toad A i62 pat N#1W Ne 4�N front 86ar QC 90.15 RapidShutdown zdta tl d d,array, a coree.ern nMule �ar Sec 25 Pyh'XhP 61Ygh2i M[ •NC C90.15AC CnnneRors,E9a33AIEx1 kneectRelta :. (25^m1*ton...,*ton...,he al 52mpht23✓ : _...._. • When1/16d ssMf kualrrowa•advig ar 3 6,013,3..• ::: Oil 71,731. e „ iot,...c:, 36 Abrettyst•Crc Manor.Gen of •Madttegrouda•g anti ba.drg xvnµn, .u:Mn-..t TheSunPrnveraMa>oem•Solar Cell Veers Pf operation .... ....... ., •r4:Akenged •Enables Mghex.ef:'krency .a,.4,a yree w.<o ev edg ro ^ .ys mth when veil oath addrch AC wiUe O Cab' a modest.: u M Ut223aY modules available- _ .__._-... _.. .._-........_. _.. ._.__ . Avarom6eNs,la "Outdoor',to % ,Cn,an,neak els!ome, •Unmatched rehattaity' Pr9 i•x... } ra.foundation Best Reliability.Best Warranty + ,lass Ihitek +Maedtt.,'Anus rating. t,r+Jo''- round dot o9a„eg _ MODULE iiiKWW J.e',wind u1 we techroog, pi ae to last That's Makit;Peul why we stand behind our module and microir..erter .sunee•a aWW caps,.to a a attwemuv.•w+dv sn.w,ed ss++�.�..a(ND 6 I DATA SHEET anMlee.afwPa ta.dl.aw.naew°ip.wahlaava .aa-Pagasaate with jh the industr/s best 25-year Combined Power and deramstrcm+meltvemta.may”lemraevetnenlamwoutcit,hitea:- 1 "•', tf.WC9•fWW b 0..91,Sr +ea llM�eNa'WIZ Product Warranty.including the highest Power Warranty 1amodanarrmaar.eet.y,wsMotahwbma g6y om..:4.w%,or. in solar. i«�wn a»>am^P`dvitMs,Poan adatyha..fo ea q saia9A.aseanl'wra taw• I _. 6• Drawn by: dn.w a« m'ir+ acn a'a.'0e.ay.n 5':w:elrram onadtate•se, reran i -. Areg Aghayants r .<rarrvene' pia.U13. mp;e n.,'.sron •wa:rraam1Stis..data,a. twa ..1.ad e.^E W...W.4 .n n SolarPaperworx.com • ,nnmeaxenq.sw.t6stvuaa., ataeoa, M Plan.. g ssvednd3ta0.4torandrowrn , nr.A Mc. A 06/olarpaperwork.com •;nlegraedwhe marwgement s uaa a.STlauo�,4.LKae owSva0 e:iotyaaarnn.gta,an..wnaw 1 _. ' DATE'06/142021 ,:pidshuteown n its a!bn.tax.nu:wxd..%OW.nm.a.x.msrmr...R....NK API>a-so.... aan•,.e neerfd and[ditlydtedC E brae. ax C11.t.)pr50Aa,lene.4 ihodu1..W PI PpAr.n,k.no.And IX v....,, • =r.E v ua eaaa,ewaea ecai4eaar '•'' . Chr.sHammond&Elaine Brennan 'kanPower for Sunpower modules • ®.r....._ oyoar cac won*sup kb armor ',co*,ae.... owe do a wm:med uemn 0. •:.w,s,sa :w. •..�w '.nw, ss ,OMc,, a� ae� r t -- S U N P W E R 67 Merchant Ave 3 a - ,e„ Yarmouth Port,MA 02675 rasa M eearamn nlc'a.w,!pp SON,ad n9rn Sca4 PV SYSTEM AS INDICATED Datasheet D 6.0 p . F w Q �mooF _F m et Fc �7w O re Q oEc Q.at0ih { EyU v c 9�i m aaa� : � ,a 0 i **.O.b4 14•i — be E:Y-q in ritx • o -g, s Ei! 1 - L L "la x b A Z Z IlIF! As y t tali a a # - t -,-• --1-- ; -Piii,t'k C 1 4 4• il/t' t„ • nP be 3 Eis ! ` . 3 � , Ec, o� va t � i ��E c Z In i o V1 — r s c y 4 S CZ 1 g _c a E I® N .,lZ c c c r .mac o = 2 .:a o J c c =� a a $ w c o f .. o Q i E B. -Ec c f 'E m n ih a o o `o no N a a Bpi c -q '� ro 'O Nc i Si 09 N ,`�� Pw LY Z in s x t to j 5> !: ; IjJ fl t. v 7II1 EC 4 $ iItE!:! c3L . 3 a 4 . g 2' ; IL y Ul iE . n` , E j ¢ s m ' m i E ,u m' m O E v a `�� PEGASUS A BETTER DAY ON THE JOB COMP MOUNT �ee••• SOLAR' t.art pent hole In I.Opuouel:Apply a CONTRACTOR COMP MOUNT oe•rter of refte. I-shape-of sealant •4 m underside of Solar Wolf Energy tashmg and p°aitron \ . nn+er end shingle Address:771 Washington St. e over Auburn,MA 01501 pilot hn e� Phone number:(888)878-4396 License#:8-940672 1 ea A�so SOLAR WOLF Simple 3-piece deogn a f for rapid imtallation 3.Place L Foot use, 4.Dove lag to requned 4 Y ,nc -_ r�,,.:'' cone end entail lar nnhedment.Attach J n' �g1 �' w,d,washer thou.,, \ �, «.,. 1 7�.. «vl pet LFnnt .� \ nufern,r,s -- nsttuetima ps Encapsulating design raises the water seal 0.9"above roof deck 9 SJ' . g . O I One-piece flashing with elevated cone-No fl press-flts or deck-level EPDM washer;to fail ,�.. l Sperfrcati.,n, Comp Mount install Ka WATERTIGHT FOR LIFE tics PSCar.o PSC-R-uo spcR cn Pegasus Solar's Comp Mount Is a cost effective-high-quality option for rail installations on composition shingle roofs. I loot Tyre Closed Sloe open Slot Closed Slut Designed to last decades,the one-piece flashing with elevated cone means there is simply nothing to fail. sir Cut te„r, I Foot flaulerg,5/16' L-Foot,Fleshing.5/6- I Foot,fiaereng.5/16'SS Lag SSLag w/EPDM washe, SS Lag w/EPDM washa, w/PPOM wane,.M+O Hex Bolt ATTACHMENT F,nnh Black O.foot and Flesh,g) DATA SHEET 25-year Warranty Superior Warterproofing Hoof type Aa,«m hr,non syle 1©'O. MTnu4a<a�udchzdv,,ncedma,,.r,l.z..f ' odmAC2RM1 houscionr C.,hhcenon, Wean Applese� IBC,ASCE/SEl7-to.AC2e6 rings t outlast the roof tn,dl 0.9"elevated water seal Raled System Drawn by: Areg Aghayanfs Con,peeble Rai All SolarPaperwork.com Mustang Materiel Pai,tedGalval,me Plus suppOrtasolarpapenvork.com DATE:06/14/2021 gg Code Compliant All-In-One Kit Packaging LFoot Mend avmin„m m.a.. Fully IBC/CBC Code Complw.n 4! Flashing,,L-feet and 55 lags Mel Lwondad Kit O,»onto 24 Chris Hammond 8 Elaine Brennan Exceeds AS 7.10 Standard. EPDM washers am mcluded in each 24 park Boxes Per Pallet 72 �"67 Merchant AveAM/ Yarmouth Port,MA 02675 Piitti. So. PV SYSTEM AS INDICATED Pegasus Selarine •100 West Ohio Averuur•Rnhmund,CA 94804 • I S10,730.1343• www.p.Sewre.M.ean peeaea Solar lee •tWWest Ohm Avenue,P„hn,,n,I.L.A 94rat4 • 1'tin ' i • wwww pegasueouar corn D 8.0 • .. tee( •.�r^ _I., . -_'=r.nrgyLink"/j Residential and CommercratW!6 . " CONTRACTOR SunPower'°Energ'Link'""I Residential and Commercial PV56 - - A Solar Wolf Energy Address:771 Washington St. Auburn,MA 01501 ..p. ........�� �+ Phone number:(888)878-4396 License#:B-940672 !tilt yogurt:communicate.moms.Audi m0 SOLAR WOLF niiiitiii r• Inc • .. te+n•,u,tt Ya.A1 r,�..eus MaMFM•rd•Na• O#vmaP 111111111111 a k.l K n l m Fr Y bb R T IIr,S . �• • ICO lc 0_at 00,4o e YA..*Cyl-llk3 00/4 SW rs41 i k as 44,4011.c... •IMP for::d•w.iwyaa r Omnm/1.**y i w000.44 b••.•s • rr,aae+nen al na•rlprnr:,,-,* — --. _ --. — Ada i.a:¢for L.e:.GmerS rvRM#I ilwM•r P,' YMh mnn',Ark**,Ah71.1,/lre 1Y•1'''. KC ►c iS•si•e mn eu*•S 415•1***,tsr, Mai....—. Mt lllly",2.40 4..*1C1 _...... ...__ , r•L,.ar tit(MN.991M1'f •Mato 0.._Ira::i•11"LL1...It U-a bona • WO. ar.sovo 'm Art cower cow sla IM t NINIA*0YwM4r , _-_ _—.......__._,......, • COW.*/tour - u.'wx± I An*Ille mr,.:utkd• '°`" `" `""An,tleent* • MONITORING SYSTEM -.-*-.v 1&dm,am*,tram*SMOI .._.....__,_ DATA SHEET 2 Cm•`a!4•dm%d*M.c•d S.9oaRaw+ksr.,u 4114 1,1,4Ve a rn-d'o G441t:P0,1"Itxe. .-- t ISipir lartaam,-•1+4wlrroc -- Drawn by: ) r� Areg Aghayants RC SolarPaperwork.corn . support@ solarpaperwork.corn AL `G'r'"fe�" DATE 06/14/2021 AaR+rt.�. / ,mom"'« 3611wC - Chris Hammond 8.Elaine Brennan 7iIllr..%— onenowora•'•✓... k ron w-a.•.•,.Ima ••rri.er m. .w.•m•a ,wE r Prn...w *tor...ram' ....®......r�..N...«,....�..,v+.....,....-.��..: T.. ... w! t , 1 ♦ 67 Merchant Ave *tor*. Yarmouth Port,MA 02675 (]das`eYs U N PO W E R" P SYSTEM AS INDICATED D9.0 ® DATE(MMIDDIYYYY) A �' CERTIFICATE OF LIABILITY INSURANCE 06(MMIDD21 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT CHRISTINE NAME: LEIB INSURANCE AGENCY PHONE 508 792 0411 FAX (A/C.No.Est1: (A/C,No): 537 PARK AVE ADDRESS: WORCESTER MA INSURER(S)AFFORDING COVERAGE NAIC It INSURER A: NAUTILUS INSURED INSURER B: SOLAR WOLF ENERGY INSURER C: 771 WASHINGTON ST INSURER D: AUBURN MA INSURER E: LIBERTY MUTUAL INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADMTYPE OF INSURANCE INSR wVoSUBR POLICY NUMBER (MMIDDIYYYY) IMM/POLICY EFF DO/TYYYI LIMITS Y EXP LTR INSR WVD GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED 100,000 X COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence) $ CLAIMS-MADE OCCUR MED EXP(Any one person) $ 5,000 A N NN1119891 06/08/2021 06/08/2022 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 I POLICY PRO-T LOC $ JEG AUTOMOBILE UABIUTY COMBINED d SINGLE LIMIT ent) $ ANY AUTO BODILY INJURY(Per person) $ ___ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS _ ____ AUTOS NON OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS Per accident ---- $ UMBRELLA UAB _OCCUR EACH OCCURRENCE $ EXCESS UAB CLAIMS-MADE AGGREGATE $ DED RETENTIONS $ WORKERS COMPENSATION WC STATU- OTH- AND EMPLOYERS'LIABILITY Y/N TORY LIMITS ER EACH ACCIDENT $ 1,000,000 E OFFICER/MEM EREXCLUDED?ANY X ECUTIVE Y N/A WC2-31S-614936-020 08/10/2020 08/10/2021 E.L. (Mandatory In NH) E.L DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY UNIT $ I DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,If more apace Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE TOWN OF YARMOUTH THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 1146 ROUTE 28 SOUTH YARMOUTH MA 02664 AUTHORIZED REPRESENTA KiE oer ACORD 25(2010/05) ©1988-201 A CORPORATIOI�t. All rights reserved. The ACORD name and logo are registered marks of ACORD :` The Commonwealth of Massachusetts ., r� Department of Industrial Accidents i - � � Office of Investigations l'' Lafayette City Center 4.1 r=f 2 Avenue de Lafayette, Boston,MA 02111-1750 wry www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/organization/individual): Solar Wolf Energy Address: 771 Washington St City/State/Zip: Auburn, Ma 01501 Phone#: 508-839-2222 Are you an employer?Check the appropriate box: Type of project(required): 1. I am a employer with 6 4. Ei I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction listed on the attached sheet. 7. ❑Remodeling 2.❑ I am a sole proprietor or partner- ship and have no employees These sub-contractors have 8. Ei Demolition workingfor me in anycapacity. employees and have workers' P tY 9. Building addition [No workers' comp.insurance comp. insurance.$ required.] 5. We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.]t c. 152,§1(4),and we have no employees. [No workers' 13.1411 OtherSolar Installation comp.insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Leib Insurance Policy#or Self-ins. Lic.#: WC2-31S-614936-020 Expiration Date: 08/10/2021 Job Site Address:67 Merchant Ave. City/State/Zip:Yarmouth Port, Ma 02675 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains an enalties of perjury that the information provided above is true and correct. Signature: Date: 6/22/2021 Phone#: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 1DBoard of Health 20 Building Department 3tCity/Town Clerk 4.1:1 Electrical Inspector 5.0Plumbing Inspector 6.0Other Contact Person: Phone#: Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute,an employee is defined as"...every person in the service of another under any contract of hire, express or implied,oral or written." An employer is defined as"an individual,partnership,association,corporation or other legal entity,or any two or more of the foregoing engaged in a joint enterprise,and including the legal representatives of a deceased employer, or the receiver or trustee of an individual,partnership,association or other legal entity,employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein,or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152,§25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally,MGL chapter 152, §25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and,if necessary, supply sub-contractor(s)name(s), address(es)and phone number(s)along with their certificate(s)of insurance. Limited Liability Companies(LLC)or Limited Liability Partnerships(LLP)with no employees other than the members or partners,are not required to carry workers' compensation insurance. If an LLC or LLP does have employees,a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested,not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant that must submit multiple permit/license applications in any given year,need only submit one affidavit indicating current policy information(if necessary)and under"Job Site Address"the applicant should write"all locations in (city or town)."A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e.a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address,telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations Lafayette City Center, 2 Avenue de Lafayette Boston, MA 02111-1750 Tel. (617) 727-4900 or 1-877-MASSAFE Revised 7-2019 Fax(617) 727-7749 www.mass.gov/dia COMMONW. •LTH OF MA CHUSRI. DIVISION OF PROFESSIONAL LICENSURE BOARD OF ELECTRICIANS ISSUES THE FOLLOWING LICENSE REGISTERED MASTER ELECTRICIAN KYLE ZUIDEMA co-w SOLAR WOLF ENERGY,INC 99 DUDLEY RD SUTTON,MA 01590 22593 A 07/3112022 726517 rtr „ k 1,,:_,;; EXPIRATION DATE SERIAL NUMBER ,e::,. ..11:0,04.;..,:..444.,,..- .,,,,,,..;,, . • ,,,,„,.:, ,,,,_ . ,. 1�4r , _ r, l ` k v 7 s n r4' r:y/ r SunPower® X21 -335-BLK-D-AC ( Residential AC Module Series Design-Driven Advantages ©� • #1 module aesthetics and efficiency' • Unmatched module reliability) rd • No electrolytic capacitors SERIES • 25-year Combined Power and Product Warranty • California Rule 21 Phase 1 compliant Maximize Value for Roof • Size system for roof, not string inverter • Optimize performance of each module Expand Deployment Options • Complex roofs and partial shading • Small systems Optimize System and Installation Efficiency • System expandability SunPower®AC modules,which include a factory-integrated SunPower Simplify& Speed Installation microinverter,provide a revolutionary combination of high efficiency, high • Factory-integrated microinverter reliability,and module-level DC-to-AC power conversion. Designed • Robust,double-locking AC connectors • Design flexibility offsite and onsite specifically for use with SunPower InvisiMountTM'and the SunPower • No DC string sizing process Monitoring System,SunPower AC modules enable rapid installation, best- • Fewer installation steps than competing in-class system aesthetics,and intuitive visibility into system performance. systems • Intuitive commissioning All this comes with the best Combined Power and Product Warranty in the industry. Component of Complete System • Built for use with SunPower®InvisiMountim and the SunPower Monitoring System(PVS5x) Grid Support Utility-Interactive Smart Inverter • Superior system reliability and aesthetics SunPower's new Type D AC module is UL tested and certified to UL 1741 SA and provides advanced smart inverter functions. SunPower Type D AC modules are fully compliant with the California Rule 21 Phase 1 /fJ//,// requirements,and the Rule 21 grid profile is easily set during commissioning with SunPower PVS5x monitoring hardware. sunpower.com Datasheet S U N I W E Rc • . 11 ' Y SunPower-' X21 -335-BLK-D-AC I Residential AC Module Series AC Elec-' .- IEEE 1547a-20143 CA Rule 21 SRD Profile (default settings) min./nom./max. min./nom./max. Frequency(Hz) 59.5/60.0/60.5 58.5/60.0/60.5 Power Factor 0.99/1.00/1.00 0.85 lead./1.00/0.85 lag. Reactive Power ±169 Var @240V 211.2/240/264V Voltage @208 V 183/208/228.8 V Max.Current @240 V 1.33 A @208 V 1.54 A DC/AC CEC Conversion Efficiency @240 V 96.0% @208 V 95.5% Max.Units Per 20 A Branch Circuit @240 V 12(single phase) @208 V 10(two pole)wye Power 320 W,320 VA No active phase balancing for 3 phase installations DC Power Data Warranties and Certifications SPR-X21-335-BLK-D-AC SPR-X20-327-D-AC • 25-year limited power warranty Nominal Power(Pnom) 335 W 327 W Warranties . 25-year limited product warranty Power Tolerance +5/-0% +5/-0% UL listed to UL 1741 SA Avg.Panel Efficiency5 21.0% 20.4% • SRDs:IEEE 1547-2003,IEEE 1547a-2014,CA Temp.Coef.(Power) -0.29%/°C Rule 21 Phase 1 •Three bypass diodes • PV Rapid Shutdown Equipment Shade Tolerance •Integrated module-level maximum power point • Equipment Grounding tracking • UL 6703,UL 9703 Connectors and cables (load break disconnection) Tested Operating Conditions • UL 1741 AC Module(Type 2 fire rating) Operating Temp. -40°F to+185°F(-40°C to+85°C) Certifications Enables installation in accordance with: Max.Ambient Temp. 122°F(50°C) • NEC 690.6 Max.Load Wind:62 psf,3000 Pa,305 kg/m2 front&back • NEC 690.12 Rapid Shutdown(inside and Snow:125 psf,6000 Pa,611 kg/m2 front outside the array) Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) • NEC 690.15 AC Connectors,690.33(A)-(E)(1) FCC and ICES-003 Class B Mechanical Data When used with InvisiMount racking(UL 2703): Solar Cells 96 Monocrystalline Maxeon Gen III • Integrated grounding and bonding Front Glass High-transmission tempered glass with anti- • Class A fire rated reflective coating PID Test Potential-induced degradation free Environmental Rating Outdoor rated Frame Weight 45.5sIbsb20.6 kg)lack anodized(highest AAMA rating) 280 02 a- r— Recommended Max. 1.3 in.(33 mm) 11 '�.., Module Spacing ,1 , Em 707 mm ]'Highest of over 3,200 silicon solar panels,Photon Module Survey,Feb.2014 l�. _ t [412 In1 ' W #1 rank in"PV Module Durability Initiative Public Report,"Fraunhofer CSE,Feb 2013.Five out of E - the top eight largest manufacturers were tested.Campeau,Z.et al."SunPower Module 111 30 mm Degradation Rate,"SunPower white paper,Feb 2013.See www.sunpower.com/facts for details. ,■i (1.2 In] 'Factory set to 1547a-2014 default settings.CA Rule 21 default settings profile set during commissioning.See the Equinox Installation Guide#518101 for more information. 'Standard Test Conditions(1000 W✓mr irradiance,AM 1.5.25°C).NREL calibration standard: i.t - -- [6 3 W wwn vuimaN SOMS current,LACCS FF and voltage.All DC voltage is fully contained within the module. LISTED "Based on average of measured power values during production. Please read the safety and installation instructioib loi details. Module Fire Performance:Type 2 See www.sunpower.com/facts for more reference information. rr more details,see extended datasheet.www.sunpower.com/datasheets. ©May 2017 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,MAXEON and InvisiMount are ' t E n trademarks or registered trademarks of SunPower Corporation in the U.S.and other countries as well.Specifications U R. included in this datasheet are subject to change without notice. s r. SunPower® InvisiMlountTM Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates even j= module spacing • Simple,pre-drilled rail splice • UL 2703 Listed integrated grounding Flexible Design I • Addresses nearly all sloped residential roofs • Design in landscape and portrait a Y.L • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and#1 mounting aesthetics • Best-in-class system aesthetics Elegant Simplicity • Premium,low-profile design • Black anodized components SunPower® InvisiMountm is a SunPower-designed • Hidden mid clamps and end clamps rail-based mounting system. The InvisiMount system hardware,and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics. • Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and • Best-in-class system reliability and aesthetics • Combine with SunPower modules and engineered to pair with SunPower modules. The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. 4� � lllllll sunpower.com 40) SUNP WER J I Y y R _... i . *4 t ..,... Y s SunPower° InvisiVountTM Residential Mounting System InvisiMount Component;Images Module*/Mid Clamp and Rail Module*/End Clamp and Rail J . PIWIIIIIIII„. — - M'd riarrn End Clamp Rail&Rail Splice Ground Lug Assembly End Cap Xe' a P. InvisiMount Component Details InvisiMount Operating Conditions Temperature 1 --Li C ry 7i'C( _ Component Materla. Weignt — 1 Max.Load 2400 Pa uplift Mid Clamp Black oxide stainless steel AISI 304 63 g(2.2 oz) 5400 Pa downforce End Clamp Biack anodized aluminum alloy 6063-T6 110 g(3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m(9 oz/ft) InvisiMount Warranties And Certifications Rail Splice Aluminum al oy 6005-T5 830 g/m(9 oz/ft) Warranties 25-year product warranty Ground Lug 304 stainless 5-year finish warranty 106.5 g/m(3.75 oz) Assembly (A2-70 bolt;tin-plated copper lug) End Cap Black acetat(POM)copolymer 10.4 g(0.37 oz) UL 2703 Listed Certifications Class A fire rating when distance between Roof Attachment Hardware Supported by roof surface and bottom of SunPower InvisiMount System Design Tool module frame is 3.5" • Composition Shingle Rafter Attachment Application • Composition Shingle Roof Decking Attachment Roof Attachment Hardware Warranties • Curved and Flat Tile Roof Attachment • Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturer's documentation *Module frame that is compatible with the InvisiMount system required for hardware Interoperability. C;2015 Sunflower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation.All other trademarks are the property of their respective owners. Sunpower com datasheet are subject to change without notice. Document e509506 Rev B SUNP WER