Loading...
HomeMy WebLinkAboutEngineer PlanLEGEND 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]--- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2��• SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2(33.5 + 12.83) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.83 (.74) = 318 GPD TOTAL: 615 S.F. 455 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED , MA DATE BOARD OF HEALTH SYSTEM PROFILEALL SYSTEM SHALL BE MARKED WITHCOMPONENTS MAGNETIC TAPE OR (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION, PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE CONCRETE COVERS TO WITHIN 3" GRADE 2" PEASTONE OR GEOTEXTILE TOP FOUND. EL, 100.0 FILTER FABRIC OVER STONE 98.0 MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 96.5' PRECAST H-10 NOTE: 2" MIN. WALL THICKNESS REQUIRED BLOCKS OR RISERS (TYP.) 2'0 4" GSCH40 PVC PRECAST RISERS MORTAR ALL ,.: 6" MIN. SUMP PIPES LEVEL, 1ST 2' �ENDS4'COMPONENTSH-10 (TYP.) INV°S EL. 92.70 4' 12MIN. INT. DIM. SIDES' \*_95.200C ° MIN. 94.8 TEE 1500 GAL H--10 TEE ••, SEPTIC TANK �4.60 ®®®® ® ®®®® - ®®®® 'o°o°o°o° DoWATERTEST D BOX ° o 0 0 ;o°o°o°o° ® ®®®®®� ® 0 0 0 0 >°0000 4' LIQ. LEVEL GAS BAFFLE ACME OR EQUAL oO;o;o;g;o;,o .• ' on�no�°ryD- FOR LEVELNESS (V ° ° ° ° oo')o')ono ®®®�® ®®®®® ®®®®®®®®®® ® ®®®® ® ®®®®®®�®®® ° ° ° ° ;oD0000$o M: 92.97' 92.80' o 0 0 0 °g°g°g°o o 0 0 0 °°°°°°°° < DoO0�a8�O�Opa�p��OpQOQ�OQOpOpQ�ODoDo o 00000. n00000000000no,pog00000000000Fo�00000„o�00000. 3�4"-1-1%2" DOUBLE WASHED STONE 4' MIN, H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. (3) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' COMPACTION. (15.221 [2]) { 2'S% SLOPE) (1 % SLOPE) 75.0' BOTTOM TH-2 NO GROUNDWATER FOUND _ (1 % SLOPE) FOUNDATION 12' SEPTIC TANK 16' D' BOX LEACHINGFACILITY 12' H FN ------------ B CHMARK: u IL. o --- - _ MENT BOUND OX 885.0' NAVD88 86 TH 8� 30 � DRAI GE EM�E 100% RESERVE ' m 29.6' O 1 COM)D O0 -o 0 BENCHMARK TOP OF CONCRETE SOUND FOUND 66�L 96.4 PROPOSED DWELLING TOF = 100.O --96 Oo .. O1 PROPOSED POOL HOtAE w i GARAGE SLAB = 99.5 v LOT".. 15 1 °4,1 F 'm/ NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPOSED 3. MINIMUM PIPE! PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H- j,Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER - PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10 CONTRACTOPo SHALL BE RESPONSIBLE FOR CALLING Rt 6A Qua . 0 0 o Dennis Pond a -- �, o Oakmont Dr Locus , xit 7 Routh 6 DIGSAFE (1-8$87344-7233) AND VERIFYING THE LOCUS MAP LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000't 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED ASSESSORS MAP 93 PARCEL 4--15 LEACHING FACILITY. 12. POOL FENCE! SHALL HAVE SELF -CLOSING SELF -LATCHING GATES, SIZE AND MATERIALS TO MEET LOCAL AND STATE BUILDING CODE, ALL DWELLING DOORS OPENING TO POOL SHALL BE ALARMED TO CODE. ZONING SUMMARY ZONING DISTRICT: R-40 DISTRICT MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20 TEST HOLE LOGS MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% MAX. BUILDING HEIGHT 35' ENGINEER: DANIEL E. GONSALVES, SE # 13587 PROP. BUILDING COVERAGE 7.5% WITNESS: PHIL RENAUD DATE: 2/14/2019 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. ELEV. 4 0" 88' 0" 86' Yarmouth Health Department vED► e 4" Name at 7» I 30" PERC 150" A LS 10YR 4/2 E MS 10YR 5/2 B LS 1OYR 4/4 C MS 2.5Y 7/4 OF 3" 6" 85.5' 48" 75.5' 132" A LS 1OYR 4/2 E MS 1OYR 5/2 B LS 1OYR 4/4 C MS 2.5Y 7/4 #42 SISTERS CIRCLE YARMOUTHPORT, A PREPARED FOR ELIE BASSIL DATE: DECEMBER 8, 2020 REV.: DECEMBE-R 30, 2020 (POOLHOUSE) Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcope.com a►own cape en,�ineeting, rnc. civil en insets 82' 75' I land 939 Moin Street ( surveyors Rte 6A) DATE DANIEL A. OJAL , P.E., P.L.S. YARMOUTHPORT MA 02675 19-014