Loading...
HomeMy WebLinkAboutNOI APPLICANT Kerry King 19 Eldredge Lane Cohasset, MA 02025 R EPRESENTATIVE Environmental Consulting & Restoration, LLC P.O. Box 4012 Plymouth, MA 02361 (617) 529-3792 Notice of Intent 8 Tide Lane, Yarmouth SUBMITTED TO Yarmouth Conservation Commission November 2022 P.O. Box 4012, Plymouth, Massachusetts 02361 617-529-3792 | www.ecrwetlands.com November 4, 2022 Town of Yarmouth Conservation Commission 1146 Route 28 South Yarmouth, MA 02664 RE: Notice of Intent, Landscape Improvements, 8 Tide Lane, Yarmouth, Massachusetts Dear Members of the Conservation Commission: Please accept this Notice of Intent application for the after the fact and proposed landscape improvements associated with the single-family residential property located at 8 Tide Lane in Yarmouth (the Site). The project is located within the 100-foot buffer zone top of the Coastal Bank, 200-foot Riverfront Area, and Land Subject to Coastal Storm Flowage. Also included in this application is the replacement of a wooden pile associated with the existing pier, ramp, and float system in the Parkers River. This application is being submitted in accordance with the Massachusetts Wetlands Protection Act Regulation and Town of Yarmouth Wetlands Bylaw. If you have any questions or require additional information, please contact me at (617) 529 - 3792. Sincerely, Environmental Consulting & Restoration, LLC Brad Holmes, PWS Manager CC: Department of Environmental Protection, Southeast Regional Office, 20 Riverside Drive, Lakeville, MA 02347 Division of Marine Fisheries Service, Attn: Environmental Reviewer, 836 South Rodney French Boulevard, New Bedford, MA 02744 Kerry King, 8 Tide Lane, S. Yarmouth, MA 02664 JC Engineering, 2854 Cranberry Highway, Wareham, MA 02538 3836 11/4/2022 3837 11/4/2022 Environmental Consulting & Restoration LLC 11/4/2022 11/4/2022 $125.003837 $110.00 8 Tide Lane, Yarmouth Site Photographs Photograph #1 – View of the existing float system that requires a pile to be replaced. Photograph #2 – View of the reconstructed and enlarged patio along the west side of the house. Note that residing and interior work on the house is underway. 8 Tide Lane, Yarmouth Site Photographs Photograph #3 – View of the reconstructed walkway. Photograph #4 – View of the driveway reconstruction area. USGS SITE LOCUS MAP 8 Tide Lane Yarmouth, Massachusetts Source: MassGIS - MassMapper N  SITE FEMA F.I.R.M 8 Tide Lane Yarmouth, Massachusetts Source: FEMA Map 25001C0588J and 25001C0589J; Effective: 07/16/2014 N  SITE Priority Habitat of Rare Species, Estimated Habitat of Rare Wildlife & Certified Vernal Pool Map 8 Tide Lane Yarmouth, Massachusetts Source: MassGIS - MassMapper N  Site LOCUS #8 EXISTING 3-BEDROOM DWELLING (SLAB) 1,000 GALLON SEPTIC TANK MAP 25 LOT 26 11,400± S.F. TIDE LAN E (40' WID E L A Y O U T ) Benchmark Garage Slab Elev. = 6.17' NAVD 88 TOF=6.2'± FENCE (T Y P ) EDGE OF P A V E M E N T S78° 03' 1 0 " W 105.00'N11° 56' 50"W90.00'S78° 03' 1 0 " W 100.00' S78° 03' 1 0 " W 25.01' MAP 25 LOT 27 MAP 25 LOT 27 SHED #4 EXISTING DWELLING (SLAB)EDGE OF VEGETATIONTOP OF COASTAL BANK5 55 4 44321043210 5 4 35 5PARKERS RIVER(TIDAL)M.L.W. (EL.=1.42'±)4x6' 4x4' 4x2' 4x1' 4x7' 4x6' 5x6' 5x4' 5x1' 4x8' INSPECTION PORT 18 ARC 36 (Model #3613) PLASTIC CHAMBERS D-BOX GEOMEMBRANE LINER 1,000 GALLON H-20 MONOLITHIC PUMP CHAMBER 3' HIGH (MAX.) RETAINING WALL 4" SCH. 40 PVC VENT PIPE50' C.B. OFFSET100' C.B. OFFSETCOVERED PORCH APPROX. PIER RAMPFLOATPILING RAMP WALK ARBOR6 7~GRAVEL DRIVE~(538 sf)~CONCRETE DRIVE~(488 sf)~CONCR E T E P A T I O ~ (398 sf)~CONCRETE PATIO~(886 sf)20. 1 ' 25.2' 24.6' -6x2'-7x2' -7x0'-5x6' -6x6' -6x7'-1-2-3-4-5-6-7-7-6-5-4-3-2-10U.S.G.S. LOCUS MAP SCALE: 1"=1000' EXISTING CONDITIONS PLAN AT 8 TIDE LANE SOUTH YARMOUTH, MA PREPARED FOR: KERRY KING PREPARED BY: JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 SCALE: 1" = 10' OCTOBER 22, 2022 JOB#5243-1 EXISTING FENCE NOTES: 1.) ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II. 2.) MEAN HIGH WATER LINE, AS SHOWN ON THIS PLAN, WAS DELINEATED BASED ON THE U.S. DEPARTMENT OF COMMERCE NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION (NOAA), STATION ID: 8447495; STATION NAME: SAQUATUCKET HARBOR, MA (EPOCH: 1983-2001). 3.) TOP OF COASTAL BANK, AS SHOWN ON THIS PLAN, WAS DELINEATED BASED ON THE STANDARDS UNDER MA DEP DWW POLICY 92-1 (ISSUED: MARCH 3, 1992). 4.) ENTIRE PROPERTY IS LOCATED WITHIN THE RIVERFRONT AREA. 5.) EXISTING CONDITIONS SHOWN ON THIS PLAN WAS BASED ON A FIELD INSTRUMENT SURVEY PERFORMED ON 9-21-22.P.B. 186, PG. 33EXISTING GAS LINE EXISTING CONTOUR50 EXISTING 1,000 GALLON SEPTIC TANK 50x0' 50 EXISTING 4" SOLID SCHEDULE 40 PVC PIPE EXISTING DISTRIBUTION BOX EXISTING OVERHEAD UTILITIES EXISTING SPOT GRADE PROPOSED CONTOUR LEGEND PROPOSED SPOT GRADE50 EXISTING WATER LINE EXISTING 1,000 GAL. H-20 MONOLITHIC PUMP CHAMBER EXISTING 2" SOLID SCHEDULE 40 PVC FORCEMAIN EXISTING ARC 36 (#3613BD) CHAMBER LOCUS EXISTING 1,000 GALLON SEPTIC TANK TO BE USED IN THIS DESIGN EXISTING SAS (APPROXIMATE LOCATION ONLY) MAP 25 LOT 26 11,400± S.F. TIDE LAN E (40' WIDE L A Y O U T ) Benchmark Garage Slab Elev. = 6.17' NAVD 88 FENCE (T Y P ) EDGE OF P A V E M E N T 5x0' TP 1 S78° 03' 1 0 " W 105.00'N11° 56' 50"W90.00'S78° 03' 1 0 " W 100.00' S78° 03' 1 0 " W 25.01' MAP 25 LOT 27 MAP 25 LOT 27 SHED L.P. #4 EXISTING DWELLING (SLAB)CHIM.EDGE OF VEGETATIONTOP OF COASTAL BANK665 55 4 44321043210 5 4 35 5PARKERS RIVER(TIDAL)M.L.W. (EL.=1.42'±)4x6' 4x4' 4x2' 4x1' 4x7' 4x6' 5x6' 5x4'5x2' 5x1' 4x8' PROPOSED INSPECTION PORT WITH ACCESS BOX TO GRADE PROPOSED TOTAL 18 ARC 36 (Model #3613) PLASTIC CHAMBERS IN A FIELD CONFIGURATION PROPOSED DISTRIBUTION BOX PROP. 40 MIL. IMPERVIOUS GEOMEMBRANE LINER; TOP EL.=6.50'; BOT EL.=2.50' PROPOSED 1,000 GALLON H-20 MONOLITHIC PUMP CHAMBER REMOVE ALL UNSUITABLE MATERIAL DOWN TO TOP OF "C" SOIL & REPLACE WITH CLEAN COARSE SAND PER 310 CMR 15.255(3) CUT BACK EX. DRIVEWAY AS SHOWN EDGE OF EX. DRIVEWAY (TYP) PROP. 3' HIGH (MAX.) RETAINING WALL PROPOSED 4" SCH. 40 PVC VENT PIPE7x7'7x5'5 76.9' STRAWBALE LINE DEWATERING SEDIMENT TRAP FOR TANK & SAS EXCAVATIONS (see detail). CONTRACTOR TO ENLARGE SIZE, SHOULD IT BE NECESSARY DURING CONSTRUCTION (DO NOT ENCROACH WITHIN 50-FT WETLAND BUFFER ZONE) WORK LIMIT LINE PROP. WATER METER PIT PROP. WATER SERVICE LINE TO REPLACE EXISTING WATER SERVICE LINE 95 . 2 '7x5'5. 5 ' EXISTING WATER SERVICE LINE TO BE REPLACED WITH NEW WATER SERVICE LINE AS SHOWN ON PLAN CONNECT NEW WATER LINE TO EXISTING WATER LINE CONNECT NEW WATER LINE TO EXIST. WATER LINE50' C.B. OFFSET70' C.B. OFFSET100' C.B. OFFSETPROPOSED ARC 36 (Model #3613) PLASTIC COUPLING (TYP OF 3) #8 EXISTING 3-BEDROOM DWELLING (SLAB) TOF=6.2'± COVERED PORCH PERGOLA (167 sf)~BLOCK PATIO~(391 sf)29.8' 32.3' ~BLOCK W A L K ~ (265 sf)~GRAVEL DRIVE~(1,045 sf)RAMPFLOATPILING RAMP WALK ARBOR -6x2' -5x6' -6x7'-1-2-3-4-6-7-6-5-4-3-2-1 PIER DESIGN DATA EXISTING GAS LINE JLCChecked By:MCP Designed By:JOB No. 5243Drawn By: 80 FEET LOCATED AT PREPARED FOR: JOSEPH & ELAINE FERRARA, TRUSTEES 8 TIDE LANE SOUTH YARMOUTH, MA 02664 4020010 1 INCH = 10 FT. 508.273.0377 PREPARED BY: JC ENGINEERING, INC. EAST WAREHAM, MA 02538 DATE: NOVEMBER 13, 2020 2854 CRANBERRY HIGHWAY SCALE: PROPOSED SEPTIC SYSTEM UPGRADEP.B. 186, PG. 33EXISTING CONTOUR50 SOUTH YARMOUTH, MA 02664 EXISTING 1,000 GALLON SEPTIC TANK 17.DEED REFERENCE: BOOK 10448, PAGE 327 SCALE: 1" = 1000' LOCUS PLAN SCALE: 1" = 10' SITE PLAN DESCRIPTIONAPP'D.DATEREV.BY ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 50x0' 50 20. 19. PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED DISTRIBUTION BOX EXISTING OVERHEAD UTILITIES TEST PIT LOCATION EXISTING SPOT GRADE PROPOSED CONTOUR LEGEND PLAN REFERENCE: PLAN BOOK 186, PAGE 33 LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. OWNER OF RECORD: ASSESSOR'S MAP 25 LOT 26 PROPOSED PROJECT IS LOCATED WITHIN: CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION THROUGH DIG-SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. ELEVATIONS BASED ON NAVD 88 DATUM. BENCHMARK ELEVATION OF 6.17' ESTABLISHED ON TOP OF GARAGE SLAB AS SHOWN ON PLAN. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. COMMUNITY PANEL # 14. ADDRESS: 18. FEMA FLOOD ZONE 16. 15. 13. 11. 10. 8. 9. 7. 6. 25001C0588J JOSEPH & ELAINE FERRARA, TRUSTEES AE (EL.11) 8 TIDE LANE SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 6.50' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. GENERAL NOTES 5. 4. 3. 2. 1. A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3" OF FINISH GRADE. A REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS. 21. PROPOSED SPOT GRADE50 EXISTING WATER LINE TOTAL DESIGN FLOW GAL/DAY DESIGN FLOW GAL/DAY/BEDROOM NUMBER OF BEDROOMS 110 330 USE EXISTING GALLON SEPTIC TANK1,000 DESIGN FLOW x 200 % = GAL/DAY660 3 12.ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 22. MCP C-1 TEST PIT DATA 0" No Mottling Observed C.S.E. APPROVAL DATE:Oct. 23, 2019 PERC NO.N/A EVALUATOR: Brian Wallace, EIT, CSE PERC RATE = July 29, 2020 ELEV WATER = TEXTURAL CLASS: DEPTH OF PERC = TEST PIT #: ELEV TOP = DATE: I 1 ' INSPECTOR: Mallory Langler 5.00' 5.00 52"0.67' 122"-5.17' C-2 Peat 10Yr 2/1 Medium Sand 2.5Y 4/2 Fill SIEVE ANALYSIS RESULTS (Soil sample taken from "C-2" soil in TP1) SAND 97.8% SILT 0.7% CLAY 1.5% PER TITLE 5 ALTERNATIVE TO PERCOLATION TESTING GUIDANCE FOR SYSTEM UPGRADES (EFFECTIVE DATE: MAY 3, 2006) UNDER POLICY BRP/DWM/PeP-P00-4: SOIL TYPE: "UNCOMPACTED" EFFLUENT LOADING RATE FOR CLASS 1, >85% SAND = 0.74 GDP/SF ASSUMED PERC RATE < 2 mpi N/A See sieve results below 74"-1.17' Weeping @ 50"50"0.83' Standing @ 64"64"-0.33' OF THE BELLERIVE REALTY TRUST TEE TEE 3" 2" SCH. 40 TO D-BOX 9" MIN.24" MIN. (TYP) 6.0'±F.G. OVER TANK EL.= @ FND. EL.= PROP. LENGTH WIDTH DEPTH 9" 14"L=8'± 1,000 GALLON H-20 PUMP CHAMBER1,000 GALLON SEPTIC TANK 7'-8"6'-0"6'-0" SLOPE @ 1% min. 40 PVC 4" SCH.3"6"36" MAX. 3" DROP MAX.13"PROP. 1,000 GAL. H-20 MONO. PUMP CHAMBER TEE 48" LIQUID LEVEL INV. OUT= OFF PUMP PUMP ON ALARM ON F.G. OVER P.C. EL.= NOT TO SCALE EXISTING 1,000 GAL. SEPTIC TANK & TANK SHALL BE INSTALLED ON A LEVEL STABLE BASE 5.8'± 2.75' 3.00' 5.6'± FINISH GRADE 2" DROP MIN. ALL TEES TO BE LINED UP DIRECTLY UNDER CENTER OF RISER OPENINGS TOF EL. =6.2'± EL.=-1.75' EL.=4.25'13"GW @ EL.=1.42' PROVIDE EXTENSION RISER OVER OUTLET COVER TO F.G. (TYP. FOR S.T. AND P.C.) 22" ZABEL FILTER MODEL # A1801-4x22 (GAS BAFFLE ON BOTTOM) 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE (FOR PUMP CHAMBER) DISCONNECT PROVIDE WATER-TIGHT SEAL AT ALL PIPE PENETRATIONS (TYP) JUNCTION BOX E=-0.25' E=0.10' E=0.75' (DIMENSIONS PER ACME-SHOREY) EL.=-1.25' PROVIDE EXTENSION RISER WITH COVER OVER INLET TO WITHIN 6" OF F.G. (TYP. FOR S.T. AND P.C.) 9" MIN. 1" BASE. FIRST TWO FEET OF OUTLET CROSS SECTION VIEW DISTRIBUTION BOX DETAIL NOT TO SCALE PIPES TO BE LAID LEVEL. OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE 2" PVC TEE FINISH GRADE OVER D-BOX = REMOVABLE WATERTIGHT RISER 36"MAX. 5" DIA. OUTLET(S) 5 6.10'6.27' 7.9'± TO WITHIN 6" OF FINISHED GRADE 12" MIN.6" 4" PVC OUT TO SAS 40 MIL GEOMEMBRANE LINER, BOTTOM ELEV. = 2.50' (MAX.) 40 MIL GEOMEMBRANE LINER, TOP ELEV. = 6.50' (MIN.) 13" 11.5' INSPECTION PORT WITH ACCESS BOX TO WITHIN 3" OF F.G. (SEE PLAN FOR LOCATION) 7.13" (TYP) 4" SCHEDULE 40 PVC MIN. SLOPE 1%FINISHED GRADE OVER CHAMBERS = SLOPE @ 2% MIN. (TYP.) 7.7' - 7.5' NOT TO SCALE 1.42' (M.H.W.) 5' MIN. (REQ'D) TOP OF SAS / B.O. = GROUND WATER ELEV.= 6.50' CHAMBER END VIEW 6.01' 0.59' 31.2' 5.0' (TYP.) CHAMBER PROFILE 1.08' (TYP.) 2.875' (34.5")5.42'(STONELESS SYSTEM) (min.) 1.0' ARC 36 CHAMBERS (Model #3613) 36" MAX. 9" MIN. FILTER FABRIC NOTE #1: DRAPE THE FABRIC TO COMPLETELY COVER THE LOUVERED SIDEWALLS OF THE CHAMBERS TO PREVENT SOIL INTRUSION. FABRIC: SPUN BONDED, MADE UP OF NYLON FIBERS, HYDROPHILIC IN NATURE • WEIGHT: 0.35 - 1 OZ/YD2 RETAINING WALL TO BE CONSTRUCTED AROUND ENTIRE PERIMETER OF SAS *CONTRACTOR TO VERIFY EXISTING ELEVATION PRIOR TO ANY WORK & NOTIFY ENGINEER IF DIFFERENT. EXISTING SEWER *3.3'± 0.83' 4.0' PROPOSED (See L.U.A. Request #1 on Sheet 2 of 2) PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE NOTE: EFFECTIVE LEACHING AREA OF 4.80 SF/LF OBTAINED FROM THE DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR SYSTEMS, INC., REVISED OCTOBER 28, 2013. TRANSMITTAL NUMBER = X235253. SYSTEM CAPACITY (TOTAL L.F. OF CHAMBERS) (4.8 SF/LF) (0.74 GPD/SQ.FT.) = GPD (93.6') (4.8 SF/LF) (0.74 GAL/SQ.FT.) = 332.5 GAL. LEACHING / DAY TOTALS: TOTAL NUMBER OF CHAMBERS: 18 TOTAL NUMBER OF COUPLINGS: 3 TOTAL LEACHING AREA: 449.3 TOTAL LEACHING CAPACITY: 332.5 INSTALL 18 - ARC 36 (#3613BD) CHAMBERS & 3 COUPLINGS PROP. 1,000 GAL. H-20 MONOLITHIC PUMP CHAMBER PROPOSED 2" SOLID SCHEDULE 40 PVC FORCEMAIN SHEET 1 OF 1 1.2' COUPLING PROVIDE FILTER FABRIC OVER ENTIRE LEACHING FACILITY (SEE FABRIC NOTE #1 BELOW) PROPOSED WATER LINE PROPOSED ARC 36 (#3613BD) CHAMBER NOTES: 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 3.) ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II. 4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. 5.) MEAN HIGH WATER LINE, AS SHOWN ON THIS PLAN, WAS DELINEATED BASED ON THE U.S. DEPARTMENT OF COMMERCE NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION (NOAA), STATION ID: 8447495; STATION NAME: SAQUATUCKET HARBOR, MA (EPOCH: 1983-2001). 6.) TOP OF COASTAL BANK, AS SHOWN ON THIS PLAN, WAS DELINEATED BASED ON THE STANDARDS UNDER MA DEP DWW POLICY 92-1 (ISSUED: MARCH 3, 1992). 7.) ELECTRIC LINE FROM PUMP CHAMBER TO CONTROL PANEL AT THE BUILDING SHALL BE INSTALLED BY THE CONTRACTOR. ELECTRIC LINE TO BE ROUTED FROM PUMP CHAMBER TO BUILDING WITH THE LEAST AMOUNT OF DISTURBANCE TO THE PROPERTY AS POSSIBLE. 8.) PROPOSED WATER SERVICE LINE TO BE INSTALLED IN ACCORDANCE WITH THE YARMOUTH WATER DEPARTMENT SPECIFICATIONS.