HomeMy WebLinkAboutNOI
APPLICANT
Kerry King
19 Eldredge Lane
Cohasset, MA 02025
R EPRESENTATIVE
Environmental Consulting & Restoration, LLC
P.O. Box 4012
Plymouth, MA 02361
(617) 529-3792
Notice of Intent
8 Tide Lane, Yarmouth
SUBMITTED TO
Yarmouth Conservation Commission
November 2022
P.O. Box 4012, Plymouth, Massachusetts 02361 617-529-3792 | www.ecrwetlands.com
November 4, 2022
Town of Yarmouth
Conservation Commission
1146 Route 28
South Yarmouth, MA 02664
RE: Notice of Intent, Landscape Improvements, 8 Tide Lane, Yarmouth, Massachusetts
Dear Members of the Conservation Commission:
Please accept this Notice of Intent application for the after the fact and proposed landscape
improvements associated with the single-family residential property located at 8 Tide Lane in
Yarmouth (the Site). The project is located within the 100-foot buffer zone top of the Coastal
Bank, 200-foot Riverfront Area, and Land Subject to Coastal Storm Flowage. Also included in
this application is the replacement of a wooden pile associated with the existing pier, ramp, and
float system in the Parkers River. This application is being submitted in accordance with the
Massachusetts Wetlands Protection Act Regulation and Town of Yarmouth Wetlands Bylaw.
If you have any questions or require additional information, please contact me at (617) 529 -
3792.
Sincerely,
Environmental Consulting & Restoration, LLC
Brad Holmes, PWS
Manager
CC: Department of Environmental Protection, Southeast Regional Office, 20 Riverside
Drive, Lakeville, MA 02347
Division of Marine Fisheries Service, Attn: Environmental Reviewer, 836 South Rodney
French Boulevard, New Bedford, MA 02744
Kerry King, 8 Tide Lane, S. Yarmouth, MA 02664
JC Engineering, 2854 Cranberry Highway, Wareham, MA 02538
3836 11/4/2022
3837 11/4/2022
Environmental Consulting & Restoration LLC
11/4/2022
11/4/2022
$125.003837
$110.00
8 Tide Lane, Yarmouth
Site Photographs
Photograph #1 – View of the existing float system that requires a pile to be replaced.
Photograph #2 – View of the reconstructed and enlarged patio along the west side of the house. Note that residing and
interior work on the house is underway.
8 Tide Lane, Yarmouth
Site Photographs
Photograph #3 – View of the reconstructed walkway.
Photograph #4 – View of the driveway reconstruction area.
USGS SITE LOCUS MAP
8 Tide Lane
Yarmouth, Massachusetts
Source: MassGIS - MassMapper
N
SITE
FEMA F.I.R.M
8 Tide Lane
Yarmouth, Massachusetts
Source: FEMA Map 25001C0588J and 25001C0589J; Effective: 07/16/2014
N
SITE
Priority Habitat of Rare Species, Estimated Habitat of Rare Wildlife
& Certified Vernal Pool Map
8 Tide Lane
Yarmouth, Massachusetts
Source: MassGIS - MassMapper
N
Site
LOCUS
#8
EXISTING
3-BEDROOM
DWELLING
(SLAB)
1,000 GALLON
SEPTIC TANK
MAP 25
LOT 26
11,400± S.F.
TIDE LAN
E
(40' WID
E
L
A
Y
O
U
T
)
Benchmark
Garage Slab
Elev. = 6.17'
NAVD 88
TOF=6.2'±
FENCE (T
Y
P
)
EDGE OF
P
A
V
E
M
E
N
T
S78° 03' 1
0
"
W
105.00'N11° 56' 50"W90.00'S78° 03' 1
0
"
W
100.00'
S78° 03' 1
0
"
W
25.01'
MAP 25
LOT 27 MAP 25
LOT 27
SHED
#4
EXISTING
DWELLING
(SLAB)EDGE OF VEGETATIONTOP OF COASTAL BANK5
55
4
44321043210 5
4
35 5PARKERS RIVER(TIDAL)M.L.W. (EL.=1.42'±)4x6'
4x4'
4x2'
4x1'
4x7'
4x6'
5x6'
5x4'
5x1'
4x8'
INSPECTION PORT
18 ARC 36 (Model #3613) PLASTIC
CHAMBERS
D-BOX
GEOMEMBRANE LINER
1,000 GALLON
H-20 MONOLITHIC
PUMP CHAMBER
3' HIGH (MAX.)
RETAINING WALL
4" SCH. 40 PVC
VENT PIPE50' C.B. OFFSET100' C.B. OFFSETCOVERED
PORCH
APPROX.
PIER
RAMPFLOATPILING
RAMP WALK ARBOR6
7~GRAVEL DRIVE~(538 sf)~CONCRETE DRIVE~(488 sf)~CONCR
E
T
E
P
A
T
I
O
~
(398 sf)~CONCRETE PATIO~(886 sf)20.
1
'
25.2'
24.6'
-6x2'-7x2'
-7x0'-5x6'
-6x6'
-6x7'-1-2-3-4-5-6-7-7-6-5-4-3-2-10U.S.G.S. LOCUS MAP
SCALE: 1"=1000'
EXISTING
CONDITIONS PLAN
AT
8 TIDE LANE
SOUTH YARMOUTH, MA
PREPARED FOR:
KERRY KING
PREPARED BY:
JC ENGINEERING, INC.
2854 CRANBERRY HIGHWAY
EAST WAREHAM, MA 02538
SCALE: 1" = 10' OCTOBER 22, 2022
JOB#5243-1
EXISTING FENCE
NOTES:
1.) ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II.
2.) MEAN HIGH WATER LINE, AS SHOWN ON THIS PLAN, WAS
DELINEATED BASED ON THE U.S. DEPARTMENT OF COMMERCE
NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION (NOAA),
STATION ID: 8447495; STATION NAME: SAQUATUCKET HARBOR, MA
(EPOCH: 1983-2001).
3.) TOP OF COASTAL BANK, AS SHOWN ON THIS PLAN, WAS
DELINEATED BASED ON THE STANDARDS UNDER MA DEP DWW
POLICY 92-1 (ISSUED: MARCH 3, 1992).
4.) ENTIRE PROPERTY IS LOCATED WITHIN THE RIVERFRONT AREA.
5.) EXISTING CONDITIONS SHOWN ON THIS PLAN WAS BASED ON A
FIELD INSTRUMENT SURVEY PERFORMED ON 9-21-22.P.B. 186, PG. 33EXISTING GAS LINE
EXISTING CONTOUR50
EXISTING 1,000 GALLON SEPTIC TANK
50x0'
50
EXISTING 4" SOLID SCHEDULE 40 PVC PIPE
EXISTING DISTRIBUTION BOX
EXISTING OVERHEAD UTILITIES
EXISTING SPOT GRADE
PROPOSED CONTOUR
LEGEND
PROPOSED SPOT GRADE50
EXISTING WATER LINE
EXISTING 1,000 GAL. H-20 MONOLITHIC PUMP CHAMBER
EXISTING 2" SOLID SCHEDULE 40 PVC FORCEMAIN
EXISTING ARC 36 (#3613BD) CHAMBER
LOCUS
EXISTING 1,000
GALLON SEPTIC
TANK TO BE USED
IN THIS DESIGN
EXISTING SAS
(APPROXIMATE
LOCATION ONLY)
MAP 25
LOT 26
11,400± S.F.
TIDE LAN
E
(40' WIDE
L
A
Y
O
U
T
)
Benchmark
Garage Slab
Elev. = 6.17'
NAVD 88
FENCE (T
Y
P
)
EDGE OF
P
A
V
E
M
E
N
T
5x0'
TP 1
S78° 03' 1
0
"
W
105.00'N11° 56' 50"W90.00'S78° 03' 1
0
"
W
100.00'
S78° 03' 1
0
"
W
25.01'
MAP 25
LOT 27
MAP 25
LOT 27
SHED
L.P.
#4
EXISTING
DWELLING
(SLAB)CHIM.EDGE OF VEGETATIONTOP OF COASTAL BANK665
55
4
44321043210 5
4
35 5PARKERS RIVER(TIDAL)M.L.W. (EL.=1.42'±)4x6'
4x4'
4x2'
4x1'
4x7'
4x6'
5x6'
5x4'5x2'
5x1'
4x8'
PROPOSED INSPECTION
PORT WITH ACCESS BOX
TO GRADE
PROPOSED TOTAL 18 ARC 36
(Model #3613) PLASTIC CHAMBERS
IN A FIELD CONFIGURATION
PROPOSED DISTRIBUTION BOX
PROP. 40 MIL. IMPERVIOUS
GEOMEMBRANE LINER;
TOP EL.=6.50'; BOT EL.=2.50'
PROPOSED 1,000 GALLON H-20
MONOLITHIC PUMP CHAMBER
REMOVE ALL UNSUITABLE
MATERIAL DOWN TO TOP
OF "C" SOIL & REPLACE
WITH CLEAN COARSE SAND
PER 310 CMR 15.255(3)
CUT BACK EX.
DRIVEWAY AS SHOWN
EDGE OF EX.
DRIVEWAY (TYP)
PROP. 3' HIGH (MAX.)
RETAINING WALL
PROPOSED 4" SCH.
40 PVC VENT PIPE7x7'7x5'5
76.9'
STRAWBALE LINE
DEWATERING SEDIMENT TRAP FOR TANK &
SAS EXCAVATIONS (see detail). CONTRACTOR
TO ENLARGE SIZE, SHOULD IT BE NECESSARY
DURING CONSTRUCTION (DO NOT ENCROACH
WITHIN 50-FT WETLAND BUFFER ZONE)
WORK LIMIT LINE
PROP. WATER
METER PIT
PROP. WATER SERVICE
LINE TO REPLACE EXISTING
WATER SERVICE LINE
95
.
2
'7x5'5.
5
'
EXISTING WATER SERVICE
LINE TO BE REPLACED
WITH NEW WATER SERVICE
LINE AS SHOWN ON PLAN
CONNECT NEW
WATER LINE TO
EXISTING WATER LINE
CONNECT NEW WATER LINE
TO EXIST. WATER LINE50' C.B. OFFSET70' C.B. OFFSET100' C.B. OFFSETPROPOSED ARC 36 (Model #3613)
PLASTIC COUPLING (TYP OF 3)
#8
EXISTING
3-BEDROOM
DWELLING
(SLAB)
TOF=6.2'±
COVERED
PORCH
PERGOLA
(167 sf)~BLOCK PATIO~(391 sf)29.8'
32.3'
~BLOCK
W
A
L
K
~
(265 sf)~GRAVEL DRIVE~(1,045 sf)RAMPFLOATPILING
RAMP WALK
ARBOR
-6x2'
-5x6'
-6x7'-1-2-3-4-6-7-6-5-4-3-2-1
PIER DESIGN DATA
EXISTING GAS LINE
JLCChecked By:MCP Designed By:JOB No. 5243Drawn By:
80 FEET
LOCATED AT
PREPARED FOR:
JOSEPH & ELAINE FERRARA, TRUSTEES
8 TIDE LANE
SOUTH YARMOUTH, MA 02664
4020010
1 INCH = 10 FT.
508.273.0377
PREPARED BY:
JC ENGINEERING, INC.
EAST WAREHAM, MA 02538
DATE: NOVEMBER 13, 2020
2854 CRANBERRY HIGHWAY
SCALE:
PROPOSED SEPTIC SYSTEM UPGRADEP.B. 186, PG. 33EXISTING CONTOUR50
SOUTH YARMOUTH, MA 02664
EXISTING 1,000 GALLON SEPTIC TANK
17.DEED REFERENCE: BOOK 10448, PAGE 327
SCALE: 1" = 1000'
LOCUS PLAN
SCALE: 1" = 10'
SITE PLAN
DESCRIPTIONAPP'D.DATEREV.BY
ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION.
THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT
ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE.
50x0'
50
20.
19.
PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE
PROPOSED DISTRIBUTION BOX
EXISTING OVERHEAD UTILITIES
TEST PIT LOCATION
EXISTING SPOT GRADE
PROPOSED CONTOUR
LEGEND
PLAN REFERENCE: PLAN BOOK 186, PAGE 33
LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK
FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS
NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH
AND DESIGN ENGINEER.
OWNER OF RECORD:
ASSESSOR'S MAP 25 LOT 26
PROPOSED PROJECT IS LOCATED WITHIN:
CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN
SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK.
WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE
MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY.
REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY,
FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3).
DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES.
NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING
REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM
APPROPRIATE AUTHORITY.
ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT.
CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION
THROUGH DIG-SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT
1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES
TO THE DESIGN ENGINEER.
ELEVATIONS BASED ON NAVD 88 DATUM. BENCHMARK ELEVATION OF 6.17' ESTABLISHED
ON TOP OF GARAGE SLAB AS SHOWN ON PLAN.
THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.
COMMUNITY PANEL #
14.
ADDRESS:
18.
FEMA FLOOD ZONE
16.
15.
13.
11.
10.
8.
9.
7.
6.
25001C0588J
JOSEPH & ELAINE FERRARA, TRUSTEES
AE (EL.11)
8 TIDE LANE
SLOPE ALL SOLID PIPE AT 1.0% MINIMUM.
4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL
SYSTEM UNLESS OTHERWISE NOTED.
ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION
METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL
CODE AND ANY APPLICABLE LOCAL RULES.
TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN
ELEVATION = 6.50' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A
40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF
THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION.
GENERAL NOTES
5.
4.
3.
2.
1.
A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A
DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3" OF FINISH GRADE. A
REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS.
21.
PROPOSED SPOT GRADE50
EXISTING WATER LINE
TOTAL DESIGN FLOW GAL/DAY
DESIGN FLOW GAL/DAY/BEDROOM
NUMBER OF BEDROOMS
110
330
USE EXISTING GALLON SEPTIC TANK1,000
DESIGN FLOW x 200 % = GAL/DAY660
3
12.ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED
UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR
TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING.
OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL
REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT.
22.
MCP
C-1
TEST PIT DATA
0"
No Mottling Observed
C.S.E. APPROVAL DATE:Oct. 23, 2019
PERC NO.N/A
EVALUATOR: Brian Wallace, EIT, CSE
PERC RATE =
July 29, 2020
ELEV WATER =
TEXTURAL CLASS:
DEPTH OF PERC =
TEST PIT #:
ELEV TOP =
DATE:
I
1
'
INSPECTOR: Mallory Langler
5.00'
5.00
52"0.67'
122"-5.17'
C-2
Peat
10Yr 2/1
Medium Sand
2.5Y 4/2
Fill
SIEVE ANALYSIS RESULTS
(Soil sample taken from "C-2" soil in TP1)
SAND 97.8%
SILT 0.7%
CLAY 1.5%
PER TITLE 5 ALTERNATIVE TO
PERCOLATION TESTING GUIDANCE
FOR SYSTEM UPGRADES
(EFFECTIVE DATE: MAY 3, 2006)
UNDER POLICY BRP/DWM/PeP-P00-4:
SOIL TYPE: "UNCOMPACTED"
EFFLUENT LOADING RATE FOR
CLASS 1, >85% SAND = 0.74 GDP/SF
ASSUMED PERC RATE < 2 mpi
N/A
See sieve results below
74"-1.17'
Weeping @ 50"50"0.83'
Standing @ 64"64"-0.33'
OF THE BELLERIVE REALTY TRUST
TEE
TEE
3"
2" SCH. 40
TO D-BOX
9" MIN.24" MIN.
(TYP)
6.0'±F.G. OVER TANK EL.=
@ FND. EL.=
PROP.
LENGTH WIDTH DEPTH
9"
14"L=8'±
1,000 GALLON H-20 PUMP CHAMBER1,000 GALLON SEPTIC TANK
7'-8"6'-0"6'-0"
SLOPE @ 1% min.
40 PVC
4" SCH.3"6"36" MAX.
3" DROP MAX.13"PROP. 1,000 GAL. H-20 MONO. PUMP CHAMBER
TEE
48"
LIQUID
LEVEL
INV. OUT=
OFF
PUMP
PUMP ON
ALARM ON
F.G. OVER P.C. EL.=
NOT TO SCALE
EXISTING 1,000 GAL. SEPTIC TANK &
TANK SHALL BE INSTALLED ON A LEVEL STABLE BASE
5.8'±
2.75'
3.00'
5.6'±
FINISH GRADE
2" DROP MIN.
ALL TEES TO BE
LINED UP DIRECTLY
UNDER CENTER OF
RISER OPENINGS
TOF EL. =6.2'±
EL.=-1.75'
EL.=4.25'13"GW @ EL.=1.42'
PROVIDE EXTENSION RISER
OVER OUTLET COVER TO
F.G. (TYP. FOR S.T. AND P.C.)
22" ZABEL FILTER
MODEL # A1801-4x22
(GAS BAFFLE ON BOTTOM)
6" CRUSHED STONE
OVER MECHANICALLY
COMPACTED BASE
(FOR PUMP CHAMBER)
DISCONNECT
PROVIDE WATER-TIGHT SEAL AT
ALL PIPE PENETRATIONS (TYP)
JUNCTION BOX
E=-0.25'
E=0.10'
E=0.75'
(DIMENSIONS PER ACME-SHOREY)
EL.=-1.25'
PROVIDE EXTENSION RISER WITH
COVER OVER INLET TO WITHIN 6"
OF F.G. (TYP. FOR S.T. AND P.C.)
9" MIN.
1"
BASE. FIRST TWO FEET OF OUTLET
CROSS SECTION VIEW
DISTRIBUTION BOX DETAIL
NOT TO SCALE
PIPES TO BE LAID LEVEL.
OUTLET DISTRIBUTION BOX
TO BE INSTALLED ON A LEVEL STABLE
6" CRUSHED STONE
OVER MECHANICALLY
COMPACTED BASE
2" PVC TEE
FINISH GRADE OVER D-BOX =
REMOVABLE WATERTIGHT RISER
36"MAX.
5" DIA. OUTLET(S)
5
6.10'6.27'
7.9'±
TO WITHIN 6" OF FINISHED GRADE
12" MIN.6"
4" PVC OUT
TO SAS
40 MIL GEOMEMBRANE LINER,
BOTTOM ELEV. = 2.50' (MAX.)
40 MIL GEOMEMBRANE LINER,
TOP ELEV. = 6.50' (MIN.)
13"
11.5'
INSPECTION PORT WITH ACCESS
BOX TO WITHIN 3" OF F.G.
(SEE PLAN FOR LOCATION)
7.13" (TYP)
4" SCHEDULE 40 PVC MIN. SLOPE 1%FINISHED GRADE OVER CHAMBERS =
SLOPE @ 2% MIN.
(TYP.)
7.7' - 7.5'
NOT TO SCALE
1.42' (M.H.W.)
5' MIN.
(REQ'D)
TOP OF SAS / B.O. =
GROUND WATER ELEV.=
6.50'
CHAMBER END VIEW
6.01'
0.59'
31.2'
5.0'
(TYP.)
CHAMBER PROFILE
1.08'
(TYP.)
2.875' (34.5")5.42'(STONELESS SYSTEM)
(min.)
1.0'
ARC 36 CHAMBERS (Model #3613)
36" MAX.
9" MIN.
FILTER FABRIC NOTE #1: DRAPE THE FABRIC TO COMPLETELY
COVER THE LOUVERED SIDEWALLS OF THE CHAMBERS TO
PREVENT SOIL INTRUSION. FABRIC: SPUN BONDED, MADE UP OF
NYLON FIBERS, HYDROPHILIC IN NATURE • WEIGHT: 0.35 - 1 OZ/YD2
RETAINING WALL TO BE
CONSTRUCTED AROUND
ENTIRE PERIMETER OF SAS
*CONTRACTOR TO VERIFY
EXISTING ELEVATION PRIOR
TO ANY WORK & NOTIFY
ENGINEER IF DIFFERENT.
EXISTING SEWER
*3.3'±
0.83'
4.0' PROPOSED
(See L.U.A. Request
#1 on Sheet 2 of 2)
PROP. VENT WITH CHARCOAL
FILTER TO ABOVE GRADE
NOTE:
EFFECTIVE LEACHING AREA OF 4.80 SF/LF OBTAINED FROM THE
DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER
CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR SYSTEMS,
INC., REVISED OCTOBER 28, 2013. TRANSMITTAL NUMBER = X235253.
SYSTEM CAPACITY
(TOTAL L.F. OF CHAMBERS) (4.8 SF/LF) (0.74 GPD/SQ.FT.) = GPD
(93.6') (4.8 SF/LF) (0.74 GAL/SQ.FT.) = 332.5 GAL. LEACHING / DAY
TOTALS:
TOTAL NUMBER OF CHAMBERS: 18
TOTAL NUMBER OF COUPLINGS: 3
TOTAL LEACHING AREA: 449.3
TOTAL LEACHING CAPACITY: 332.5
INSTALL 18 - ARC 36 (#3613BD) CHAMBERS
& 3 COUPLINGS
PROP. 1,000 GAL. H-20 MONOLITHIC PUMP CHAMBER
PROPOSED 2" SOLID SCHEDULE 40 PVC FORCEMAIN
SHEET 1 OF 1
1.2' COUPLING
PROVIDE FILTER FABRIC OVER
ENTIRE LEACHING FACILITY
(SEE FABRIC NOTE #1 BELOW)
PROPOSED WATER LINE
PROPOSED ARC 36 (#3613BD) CHAMBER
NOTES:
1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF
EACH SEPTIC SYSTEM COMPONENT.
2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE
PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT
DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF
HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA.
3.) ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II.
4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY
FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS
IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL
NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT.
5.) MEAN HIGH WATER LINE, AS SHOWN ON THIS PLAN, WAS DELINEATED
BASED ON THE U.S. DEPARTMENT OF COMMERCE NATIONAL OCEANIC AND
ATMOSPHERIC ADMINISTRATION (NOAA), STATION ID: 8447495; STATION
NAME: SAQUATUCKET HARBOR, MA (EPOCH: 1983-2001).
6.) TOP OF COASTAL BANK, AS SHOWN ON THIS PLAN, WAS DELINEATED
BASED ON THE STANDARDS UNDER MA DEP DWW POLICY 92-1 (ISSUED:
MARCH 3, 1992).
7.) ELECTRIC LINE FROM PUMP CHAMBER TO CONTROL PANEL AT THE
BUILDING SHALL BE INSTALLED BY THE CONTRACTOR. ELECTRIC LINE TO BE
ROUTED FROM PUMP CHAMBER TO BUILDING WITH THE LEAST AMOUNT OF
DISTURBANCE TO THE PROPERTY AS POSSIBLE.
8.) PROPOSED WATER SERVICE LINE TO BE INSTALLED IN ACCORDANCE WITH