Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. /� Lot 3 Zone of Contribution: In Out y Acreage / n_n (o. Commercial: Residential: Street: (o � Village: (.� _ Floor Plan: 7. #Bedrooms: Owner: /d/ci c /1YC/i-0'(,!/ Installer: Address: Phone: Phone: Builder: Engineer: ,c77tg rf (i‘e411 Address: Phone: - t Phone: -- x %" ` N/A YES NO 1.Required#of copies received Lf 2. Date of soils exam and percolation test not older than 2 years �/' 3. 4-5 ft of naturally occurring pervious material, above water table ✓- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: \__ 5. Water line 10 ft from septic components Var.: L� 6. Benchmark indicated and shown-NGVD if near wetlands L� 7. Septic tank minimum 10 ft from foundation, deck Var.:8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: i..----"'- 12. System meets all other setback requirements Var.: �.------' 13.Uses adjustment for maximum high groundwater Var.: �_�== 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: \----- 15. System not in top or subsoil(A,B horizons or 5' removal �,/' 16.Proposed contours are suitable i 17. System meets slope requirements-min. 1/8", '/4"preferred �� 18. System meets breakout requirements PVC liner: Wall: .._/ 19. Specified tee sizes are proper, gas baffle on outlet tee k. 20. Sewage is under 10,000 gpd for parcel ,------' 21.No garbage disposal L/ 22. System adequately sized for its intended use ` i 23.Minimum 6"stone or compacted below tank and dbox , 24.Manhole covers within 6"of grade, pump chamber cover to grade L----- 25. Inspection port on plastic chambers/leach field t / 26. Electrical permit for pump chamber/Separate meter for duplexes / 27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size ��J 28. Septic tank/pump chamber to be factory waterproofed ,_-� 29. Vent provided if leaching below 3 feet, under driveway/parking ,_� 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: `/ 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature L� 33. H-20 loading is subject to vehicular traffic, groundwater c_/ 34. Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house _/� 36. Deed Restriction required max. #bedrooms: max. flow: gpd _------ /, 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03