HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. /� Lot 3 Zone of Contribution: In Out y Acreage
/ n_n (o.
Commercial: Residential:
Street: (o �
Village: (.� _ Floor Plan: 7. #Bedrooms:
Owner: /d/ci c /1YC/i-0'(,!/ Installer:
Address: Phone:
Phone:
Builder: Engineer: ,c77tg rf (i‘e411
Address: Phone: - t
Phone: -- x %"
` N/A YES NO
1.Required#of copies received Lf
2. Date of soils exam and percolation test not older than 2 years �/'
3. 4-5 ft of naturally occurring pervious material, above water table ✓-
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: \__
5. Water line 10 ft from septic components Var.: L�
6. Benchmark indicated and shown-NGVD if near wetlands L�
7. Septic tank minimum 10 ft from foundation, deck Var.:8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.: i..----"'-
12. System meets all other setback requirements Var.: �.------'
13.Uses adjustment for maximum high groundwater Var.: �_�==
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: \-----
15. System not in top or subsoil(A,B horizons or 5' removal �,/'
16.Proposed contours are suitable i
17. System meets slope requirements-min. 1/8", '/4"preferred ��
18. System meets breakout requirements PVC liner: Wall: .._/
19. Specified tee sizes are proper, gas baffle on outlet tee k.
20. Sewage is under 10,000 gpd for parcel ,------'
21.No garbage disposal L/
22. System adequately sized for its intended use ` i
23.Minimum 6"stone or compacted below tank and dbox ,
24.Manhole covers within 6"of grade, pump chamber cover to grade L-----
25. Inspection port on plastic chambers/leach field t /
26. Electrical permit for pump chamber/Separate meter for duplexes /
27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size ��J
28. Septic tank/pump chamber to be factory waterproofed ,_-�
29. Vent provided if leaching below 3 feet, under driveway/parking ,_�
30. Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial: `/
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature L�
33. H-20 loading is subject to vehicular traffic, groundwater c_/
34. Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house _/�
36. Deed Restriction required max. #bedrooms: max. flow: gpd _------ /,
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 6/03/03