HomeMy WebLinkAboutEngineer PlanLOCUS MAP GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING PURPOSES ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET, SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3 ' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D-BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "DIG -SAFE". 1-888-DIG-SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UT I L 1 T 1 ES - 8. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DES 1 GN ENGINEER TWO DAYS PR 1 OR TO CONSTRUCTION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE CONSTRUCTION INSPECTIONS. 9. ALL UNSUITABLE MATERIAL (A d B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. /0. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZON i NG REGULA T I ONS . IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS, VARIANCES ETC. FOR THIS PROJECT. 1/. IT SHALL REMAIN THE CL 1 ENT ' S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. I ACCESS COVERS MUST BE WITHIN 9 " MINIMUM. 6" OF FINISH GRADE 3' MAXIMUM COVER 97.0 FIRST 2' TO BE L E VEL7 MI N 2 " OF PEA STONE OR F I L TER FABRIC 4' DIAM PIPE 3/4" - 1 1/2" DIA. 0 93.5 0 92. 75 91,83 2 �o DOUBLE WASHED STONE 93. 0 FFLEJ g2' 0 89. 3 87. 3 3 OUTLET 3-500 GAL LEACHING CHAMBERS Mir °� 1 D-BOX W/4' STONE AROUND. 12.8'w x 33.5'1 x 2'd l50 GAL H-20 SEPTI TANK 6 - CRUSHED STONE OR COMPACTED BASE PROF l L E : NOT TO SCALE I N VER T EL E VA T l ONS : DES l GN CRITERIA: INVERT AT BUILDI G: 93.5 DESIGN FLOW: INVERT IN SEPTIC TANK: 93. 0 4 BEDROOMS AT 1/0 G.P.D. PER INVERT OUT SEPTIC TANK: 92.75 BEDROOM EQUALS 440 G.P.D. INVERT IN DIST. OX: 92.0 INVERT OUT DIST. BOX: 91.83 NO GARBAGE GRINDER INVERT IN LEACH HAMBER : 89.3 SEPTIC TANK REQUIRED: BOTTOM OF LEACHCHAMBER: 87.3 440 G.P.D. X 200% - 880 GAL. ADJUSTED GROUNDWATER: N/A SEPTIC TANK PROVIDED: 1500 GAL. MINIMUM OBSERVED GROUND WATER. N/A BOTTOM OF TEST H LE #l: 75.4 SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MIN/ I NCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0. 74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED PROVIDED: 3-500 GAL LEACHING CHAMBERS W/4 ' STONE AROUND. A-614 S.F. 6I4- S.F. x 0. 74- _454 G. P._D. - CB BRKA CO DH \ 1 1 \ 87.92 rn I I \ 1 I ) \ \ I l t 1 \ \ 1 r \ 1 \ / VEWAY \ / PAVED DR! \\ GARAGE \ \ 1 IQA \ \ 9a ------- 1 \\ \\ \\ \ \ \ _ --- fcl / GRAVEL DR/ VE \ PROPOSED DRIVEWAY / 92,6 cP \ I \ I CB DH FND16, 95 6 / / O F 1 EXISTING \ \ 12- NES SEPTIC SYSTEM - 92.5 /\ \\ \\\ \\\------- 6 TO BE REMOVED P) OPOSED \ 164 RA GE 9i. PofleH 1! 96 - 8 1 \ \\ ° TP#3 1 1 1 PROQSED DWELLING ,l rl 1 � 1 TOP OF` FOUND - 97\0\\ 2 I 112.8' SOIL TEST P l T DA TA s \ I , , r n 1 , TP.4, to INDICATES V INDICATES PERCOLATION = OBSERVED 1 1 1 1 ! / \ TEST GROUNDWATER I ( 10' _ / t -� • •-• •' 1 • I � / BM. CB SEAL FND TP # l TP s2 r 1 1 /PORCH / Y ..:.: _ - 1 IQ T P• I EL -90.0 l 1500 GALLON D BOX HORIZON TEXTURE COLOR89.4 HORIZON TEXTURE COLOR 918 /-. : .1 H \ l % / SEPTIC TANK', 'O \ 0 0 11 II I / // 96.3 �r i' 96 3"--- -- -- -- --- - -- 89.2 3" --- --- -- - - - -- -- 9/.6 1 1 1 / , /fig J TP2 \, \ LOAMY IOYR LOAMY IOYR 2 1 1 \ / / /9 95 1'.'.. j I \\ '4 SAND 3/3 A SAND 3/3 v o�� 1 / / ' 1' I 89 - 4 9'--- -- ---- -- - - -- 88.7 6'----- ---- - - - - -- 91.3 + B LOAMY IOYR B LOAMY IOYR '\ / / // / / 3-�00 GALLONi 80- I / LEACHING CHA48ERS 22 SAND 5/8 SAND 5/- \ ' / W,14' STONE AROUND 30'------ -- --- - - -- 86.9 30' --------- ---- -- 89.3 1� \-9 94.3 I" C / MED I UW IOYR Cl MED I UM IOYR 1 / /' /'' /'' + 9 A- SAND 7/2 SAND 7/2 - / / / , . - 92. 6 1 rV 168 _ NO WATER 75.4 168' NO WATER 77.8 TP *3 TP *4 O_ HORIZON TEXTURE COLOR 94.1 0' HORIZON TEXTURE COLOR 94.7 0 0 3' ---- ---- - - - - - -- 93.9 3' ---- -- ----- - - -- 94.5 A LOAMY IOYR A LOAMY IOYR SAND 3/3 SAND 3/3 6 -- -- ---- --- ---- 93.6 6' ---- --- -- -- ---- 94.2 B LOAMY IOYR B LOAMY IOYR 5AND 5/8 SAND 5/8 24' ---- ----- - - - - -- 92.1 24' ---- - ----- - - - -- 92.7 C / MEDIUM IOYR C / MEDIUM IOYR SAND 7/2 SAND 7/2 48' 132' NO WATER 1 83.1 132' 1 NO WATER DATE: FEBRUARY 16. 2021 TEST BY: MIC14AEL O'LOUGHLIN WITNESSED BY: MALLORY LANGLER PERC RATE: C 3 MIN/INCH LEGEND CB CONCRETE BOUND -W WATER L l NE O HYDRANT G GAS L I NE OHW- OVER HEAD WIRES -0 LIGHT POST E- UNDERGROUND ELECTRIC LINE -T - UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEVISION LINE -I- 40.4 SPOT ELEVATION ., ._40------- EXISTING CONTOUR 401 PROPOSED CONTOUR 83.7 0 1 10 20 / ' 90.4 /P"0 T 2 45.677+ S.F. A No. 38721 � VET S l TE7 PLAN OF LAND t:j� Cl OAK H / LL LANE . MAP l l 9 . P/O PARCEL 8 SOUTH l'ARMOUTH. MA- PREPARED FOR : GR EG HA ND R EN SCALE: l -- 20 APR / L 2 3. 2021 STEPHEN A. HAAS. PE 293 Cran\/iew Road Brewster, MA 02631 f 0 LOT l 55.549* S.F. 5ftm CS SEAL FND JOB NO: 2/-001 E9cc LIO u 1.0 04 21 HEALTH [DEPT.