HomeMy WebLinkAboutBLDE-22-005266 0V) Commonwealth of Official Use Only E` Massachusetts Permit No. BLDE-22-005266 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:3/21/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 49 BARNBOARD LN Owner or Tenant Brienchard Srfleur Telephone No. Owner's Address MA Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of Solar PV System 41 Panels 14.55 KW Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total nal No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: , „ Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: NATHAN A ASHE Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 R E C E / E A./ Zfficial Use Only Commonwealth o/Mamach ..el yMA�'w •_1* I , PermitNo. -.22 - 04:26C 1JI Y Apartment o/Dire Serviced Occupancy and Fee Checked BUILDING ':, ,t. MRD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) By AP ' A TION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527CMR12.00 (PLEASE PRINT IN INK OR,TIPS ALL I FORMATION) Date: 3- in-Q�_X`.(CX City or Town of: `(nrTo the Inspector of Wires: By this application the undersigned gives otice of his or her intention to perform the electrical work described below. Location(Street&Number) U4 rn '\ Ln F . Owner or Tenant hn[r S Ti"�_ r Telephone No. 77u .qqq- (Cl�l Owner's Address S nuve, Is this permit in conjunction with a building permit? Yes va No n (Check Appropriate Box) Purpose of Building n(,1eutUtility Authorization No. Existing Service an Amps / Volts Overhead d Undgrd❑ No.of Meters I New Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters Number of Feeders and Ampacity Locationand Nature of Proposed Electrical Work: ins-6 a-(on & red (i phDinVolinic. oior s Stenns ; ut pc e& 1LIM KW Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No. T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Connection Other No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water No.of No.of HeatersKW Data Wiring: Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: � � Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Valu o ''cal Work: .]Il 902..mU (When required by municipal policy.) Work to Start: ., Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such covea is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE Z' BOND ❑ OTHER 0 (Specify:) I certify,under t •p, 'ns and pen,ties of perjury,that the information on this application is true and complet. FIRM NAME: L it II i LIC.NO.: Licensee: I • k i A Signature / _ / LIC.NO.. (If applicable�nter " emptla*license number l e,L Bus.Tel.No.: EMI =Address: C5. , 9les _sh h„dt icunioh Mg , OWO Alt.Tel.No.:M.G.L.c. 147, 57-61, security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ r SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:14555W DC,9800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), r , j----SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(41)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE 1 LTD:LR4-60HPB-355M INSTRUCTIONS. L J P e 0 q PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE3800H-USS3,(1)SOLAREDGE TECHNOLOGIES: •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. LM J MAIN PANEL - _ - PV-3.0 LAYOUT SE6000H-USSN •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY a PV-4.0 ELECTRICAL •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. _-� TRACK ON COMP,SEE DETAIL SNR-DC-00436 •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SUB-PANEL SNR MOUNT SP PV-5.0 SIGNAGE - SNR MOUNT&SKIRT •MAIN PANEL UPGRADE.EXISTING 200 AMP MAIN PANEL WITH •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 200 AMP MAIN BREAKER TO BE REPLACED WITH NEW 225 AMP •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. MAIN PANEL AND 200 AMP MAIN BREAKER. •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II LC PV LOAD CENTER XCHIMNEY MODULES,ARE CLASS A FIRE RATED. •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). SM SUNRUN METER ATTIC VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. ._i FLUSH ATTIC VENT •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. PM DEDICATED PV METER PVC PIPE VENT •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). Cs METAL PIPE VENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INV INVERTER(S) LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION 23i T-VENT �tH OF41q ]ACI AC DISCONNECT(S) `•o 44's. i f SATELLITE DISH s', CHER P, DC STRJCTiIRAL L3 0 DC DISCONNECT(S) FIRE SETBACKS i.\ 4, .,°E��o�O,. IQ COMBINER BOX f HARDSCAPE \FSSiL�°•• :N CB r-1 INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 (E) EXISTING Des MYLESSTANDISHBLVD,TAUNTON,MA0ne0.7331 ESS ENERGY STORAGE SYSTEM FAHONE0 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC BRIENCHARD STFLEUR MSP MAIN SERVICE PANEL 49 BARNBOARD LN, (N) NEW YARMOUTH,MA,02673 ,1 NTS NOT TO SCALE OC ON CENTER TEL.(774)417-2247 PRE-FAB PRE-FABRICATED APN:YARM-000056-000001 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: 49 BU'PAoard Lr. PV PHOTOVOLTAIC V!,Yarmouth VIA RSD RAPID SHUTDOWN DEVICE 223R-049STFL TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL V VOLTS BRAD SOBER W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET - REV:A 3/9/2022 PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=3/32"=1'-0" SITE PLAN DETAIL-SCALE=31128"=1'-0" PITCH AZIM AZIM (SQFT) AR-01 41° 113° 127' 509.8 VIP AR-02 23° 293° 307° 294.1 g a /-- (N)ARRAY AR-02 /N( ii 414 (E)RESIDENCE 4..i,4 _ Oe eriff g 2 tati QEf ♦ ¢�L------ � P ♦ ♦ #_. ♦ s♦ (N)ARRAY AR-01 unrun I ♦ #180120 OS MYLES STANDISH BLVD,TAUNTON,MA 02700,31 HONED FAX 0 AP CUSTOMER RESIDENCE. \ SMP C� BRIENCHARD STFLEUR O)[ 49 BARNBOARD LN, YARMOUTH,MA,02673 INV INV LCO PM SE - TEL.(774)417-2247 APN:YARM-000056-000001 PROJECT NUMBER 223R-049STFL jH V9 DESIGNER: (415)580-6920 ex3 /' PAUL K. BRAD SOBER CACHER 9.(STCTURAL E"- RJSHEET 00 " SITE PLAN NOTES: � No 30 ` . e °. NO GATES OR FENCES S/ONALE r` REV:A 3/9/2022 PRESENT ON SITE PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max 00 Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Configuration Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON - WIND SPEED: N 16" COMP,SEE DETAIL SNR-DC-00436 -1" 4-0" 2-0" STAGGERED 140 MPH 3-SEC GUST. AR-02 COMP SHINGLE-RLU 2-Story2X8 RAFTERS 14'-0° - - 5/16'XG SCREWS: AR-01 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 13'-0" RL UNIVERSAL,DETAIL SPEEDSEAL TRACK ON 5/16"X UR L MIN EMBEDMENT 16 COMP,SEE DETAIL SNR-DC-00436 1'-10" STAGGERED STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:1/8"=1'-0" ENGINEER OF ANY POTENTIAL AZIM:113° STRUCTURAL ISSUES PITCH:41' 18'-1" 17-5" OBSERVED PRIOR TO PROCEEDING W/ 1 6 INSTALLATION. IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE ���� = EDGES(EXCEPT VALLEYS), MIATHEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG � � REDUCED WITHIN THE 17'-3" BOUNDARY REGION ONLY AS FOLLOWS: _�- _ IIIIII •.•ALLOWABLEACING ATTACHMENT 11.0111,. SPACING INDICATED ON • ��� PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG III INDICATED ON PLANS TO BE 6"" 1/5TH OF ALLOWABLE ATTACHMENT SPACING ---6'-5" -- -------- ---29'-1" INDICATED ON PLANS D2-AR-02-SCALE:1/8"=1'-0" PITCAZIMH:19° sunrun PITCH:19° k -.5'_9"— 11'_8.,_--_.- ? ----11,_7,x- #180120 MYLOES STANDISH BLVD,TAUNTON.MA,03780-7331 PHONE1'-6" FAX 0 1 _ - CUSTOMER RESIDENCE: RDS FLEUR 4 BARN OA D LN, 49 BARNBOARD LN, YARMOUTH,MA,02673 TEL.(774)417-2247 13'-10" 1:1111:10.1. - APN:YARM-000056-000001 _ _ _ � PROJECT NUMBER: •11111111.1.111 ESIGNERSTFL L�y1H�'U'9Ss DESIGNER: (415)560-0920 ex3 9 PAUL K. % BRAD SOBER 6��.3 ZACHENL, SIRJCTURAL ;.,-4 SHEET 5'-z" —---zs'-r • r• r-s" L` .Ng:so�9o. e LAYOUT SIONAL0-'`' REV:A 3/9/2022 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE SOLAREDGE TECHNOLOGIES: SE3800H-USS3 OMETER#: 3800 WATT INVERTER JUNCTION BOX PV MODULES EVERSOURCE 1983401 2a OR EQUIVALENT 9 LONGI GREEN ENERGY TECHNOLOGY UTILITY �/ CO LTD:LR4-60HPB-355M GRID SUPPLY SIDE TAP .`-'..s - ~~/ j —•--- S 4(T// OPT MIIZER(16) S WIRED IN: I I (1)SERIES OF(16)OPTIMIZERS '' (N)100A PV LOAD LOAD RATED DC DISCONNECT CENTER WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS • 0(6) I COMPLIANT P401 (Nt 1 NEW 200A MAIN BL LOCKABLE 3a BLADE TYPE (N)MA SMART BREAKER FUSED AC (N)LOCKABLE UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT BLADE TYPE REVENUE J SE6000H-USSN AC DISCONNECT METER 6000 WATT INVERTER JUNCTION BOX PV MODULES / (A� OR EQUIVALENT 22 A 1 " �\ 3b� 7/7--- 2b 1b // CONGI GREEN ENERGY N R 55MECHNOLOGY ---..."—N.— O J ^ " ^� J t / (25)MODULES MAIN i. , `Y OPTIMIZERS WIRED IN: FACILITY PANEL 60A FUSES I I (1)SERIES OF(12)OPTIMIZERS LOADS -.1= SQUARED SQUARED 240V METER SOCKET 20A BREAKER(A) LOAD RATED DC DISCONNECT i (1)SERIES OF(13)OPTIMIZERS D222NRB DU222RB 100A CONTINUOUS 35A BREAKER(B) WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1a NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 1b NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER s u n r u n 2a 3/4"EMT OR EQUIV. (2)10 AWG THHWTHWN-2 NONE (1)10 AWG THHN/THWN-2 2b • 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHNJTHWN-2 #180120 3a 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG TIHN/THWN-2 (1)8 AWG THHN/THWN-2 6/35 uYLES STANDISH..TAUNTON NA,02780.7.13+ PHONED 3b 3/4"EMT OR EQUIV. (2)8 AWG THHNITHN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 A o W CUSTOMER RESIDENCE: 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 BRIENCHARD STFLEUR 49 BARNBOARD LN, 5 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHWTHWN-2 YARMOUTH,MA,02673 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(774)417-2247 LONGI GREEN ENERGY APN:YARM-000056-000001 TECHNOLOGY CO LTD: MIN INPUT VOLTAGE: 8 VDC MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR460HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC 223R-049STFL MAX POWER VOLTAGE: 34.6 V SHORT CIRCUIT CURRENT: 11.25 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM CHARACTERISTICS-INVERTER 2 BRAD SOBER SYSTEM SIZE: 5680 W SYSTEM SIZE: 8875 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 16 V SYSTEM OPEN CIRCUIT VOLTAGE: 13 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 3/9/2022 SYSTEM OPERATING CURRENT: 14.95 A SYSTEM OPERATING CURRENT: 23.36 A SYSTEM SHORT CIRCUIT CURRENT: 15 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.O INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION: INVERTER 2 INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE: 480 VDC LABEL LOCATION: INVERTER(S),DC DISCONNECT(S). PER CODE(S):NEC 2020:690.53 DUAL POWER SUPPLY WARNING: PHOTOVOLTAIC SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC POWER SOURCE SYSTEM LABEL LOCATION: LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, CAUTION • UTILITY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2020:705.12(C) PER CODE(S):NEC 2020:690.31(D((2),IFC 2012: 805.11.1.4 MULTIPLE SOURCES OF POWER • A RAPID SHUTDOWN SWITCH H POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEN9 DO NOT RELOCATE THIS 1111 SOLAR PANELS ON ROOF/ OVERCURRENT DEVICE 11111 LABEL LOCATION: ;; LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN 1111 s u n r u n ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC FUSED AC DISCONNECT SOCPD ):NEC 2 (IF APPLICABLE). 2012 605.11.1,IFC 2016:1204.5.3 1111 PER CODE(S):NEC 2020: , 7os.,z(B)(3)(z) 11 1111 MAIN PANEL(INT) II #180120 SOLAR PV SYSTEM EQUIPPED 1111 1, „ SERVICE ENTRANCE EPS MYLEssrANDISHBLVD,TAUNTON,MA,o„eo„3, PHOTOVOLTAIC WITH RAPID SHUTDOWN PANELaHweo COMBINERR E o DO NOT ADD LOADS UNFUSED AC DISCONNECT CUSTOMER RESIDENCE BRIENCHARD STFLEUR LABEL LOCATION: PHOTOVOLTAIC AC COMBINER(IF PV PRODUCTION METER 49 ARD LN, APPLICABLE). MOUTH,MA,02673 PER CODE(S):NEC 2020:705.12)D)(2))3((c) 3” TURN RAPID SHUTDOWN SWITCH TO THE"OFF" ,N. PV LOAD CENTER TEL.(774)417-2247 POSITION TO SHUT DOWN APN:YARM-000056-000001 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE -INVERTER (EXT) PROJECT NUMBER: SHOCK HAZARD IN THE 223R-049STFL MAXIMUM AC OPERATING CURRENT:40.83 AMPSall NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. INVERTER (EXT) DESIGNER: (415)580-092o ex3 LABEL °CATI°": 49 BARNBOARD LN, YARMOUTH, MA, 02673 BRAD SOBER AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. ^ SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 3/9/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0