Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-21-006343 PLANS
GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: 2015 INTERNATIONAL RESIDENTIAL CODE 2020 NATIONAL ELECTRICAL CODE 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION SHEET INDEX ^® PV 0.0-COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES ^�C//) E 3.0-WARNING LABELS \ ✓l E 4.0-WARNING LABEL LOCATIONS 7(22LE 5.0-BONDING DETAILS GENERAL ELECTRICAL NOTES GENERAL STRUCTURAL NOTES 1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED SYSTEMS- ROCK-IT RAIL-LESS SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SPACED AS SHOWN IN THE DETAILS-AND MUST BE STAGGERED TO ADJACENT SURFACE. FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE 2.UNLESS NOTED OTHERWISE SEE S 1.0-MOUNTING ANCHORS SHALL BE 5116'LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2.1/4/MIN PENETRATION INTO ROOF FRAMING. 3.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE 3.THE PROPOSED PV SYSTEM ADDS 3.0 pef TO THE ROOF FRAMING SYSTEM 4.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE 4.ROOF LINE LOAD•20 pet TYPICAL-0 pef UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE 6.GROUND SNOW LOAD•30 pet I `'' VOLTAGE. 6.WIND SPEED•140 mph 5.SEE•E 1.0 AND 2.0 FOR DIAGRAMS-CALCULATIONS-SCHEDULE AND 7.EXPOSURE CATEGORY•B SPECIFICATIONS vivint.Solar Sunrun coMrAN,v 1800 ASHTON BLVD.LEHI,UT,84043 1.977.404.4129 MA LIC:170848 1180BBA PHOTOVOLTAIC SYSTEM SPECIFICATIONS 1,7 Circuit Rd E, SYSTEM SIZE-5.85KW DC 13.8KW AC WARBURTON RESIDENCE 7CIRCUIT RDE West Yarmouth.MA... MODULE TYPE&AMOUNT-(18) JINKO SOLAR JKM325M-6OHBL WITH SOLAREDGE P370 OPTIMIZERS WEST YARMOUTH,MA 02673-372A • MODULE DIMENSIONS:(UW/H)66.3139.5/1.4 UMW ACCOUNT:27161470070 METER 2306264 INVERTER:(1)SOLAREDGE TECHNOLOGIES SE3800H-US 3. INTERCONNECTION METHOD(GRID-TIED):LOAD BREAKER Se S-6621196 ROC:MA-03 PV 0.0 DRAWN BY:DIN -:r_ DATE 04/24/2021 _s REVISION:0 '� PV STRINGS: ROOF SECTION: SYSTEM LEGEND PV SYSTEM SIZE: ®PV STRING 1=10 MODULES ROOF PLANE 1 SLOPE•31° (N)5.85010/DC 13.800kW AC PV STRING 2=8 MODULES ROOF PLANE 1 AZIMUTH=228° ROOF 1 MAT•COMPOSITION SHINGLE Mii POINT OF TION IN guil EXISTING INTERIOR MSP CTED TO 7 CIRCUIT RD E UTIUTY METER 2305244. FRONT OF HOUSE. ©OFM TMETER.LOCATEOWITHPIC g(N)PV SYSTEM AC DISCONNECT. CCCCCN)1 P/STRING INVERTER� � : (N)IS JINKO SOLAR J164326M-6011 0 MMODULES WITH P370 OPTMIZERS61. MOUNTED ON THE BACK OF EACH MODULE. ®(N)JUNCTION BOX. (MOUNTED WITM SOLADECK) LiEXISTING DETACHED UTKm METER(2305264) 0 7 / \ 714 \ 0E3° .//A 0 O vivint.Solar A sunrun CUM'A'ti Y 1800 ASHTON BLVD.LEHI,UT,04043 1.877.1044126 MA LIC:170848)16686A WARBURTON RESIDENCE 7CIGCUIT RDE iWEST YARMOUTH,MA 02675372/ UTILITY ACCOUNT:27161170070 i METER 2306281 +� SITE PLAN 7156 ROC: PV 1A 1.0A43 SCALE:3116"=1'-0" DRAWNBo10irs 21 REVISION:0 9 MOUNTING NOTES ROGER COUPLING MC CAMP ROOM'COUPUNO Ak MID CAMP Mr MO .10 'Lids Ji■ S ' ROCX4T10000PLMO Ill I) MOWI R 'RSUM MD DAMP PEDESTAL .11 0 �— MnAL HEX FIANCE JOLT BB FUMING ® CCIPLNOlH F 01":1 300 SEEMS (T; ROCK4T COUPLING SHELF \, COAs MTINGLlB iiz ii it 8S LAO SCREW --11- 411 TOROUE•13A2 R4-B8. TE PLATE HE(FLANGE HEX FIANCE SCT 8 ILSC0 SGB{GROUNDING LUGS nun 300 BER-!BB �� Y fl 49 ROCK.I'T 3.0 MOUNT DETAIL S 1.0 NOT TO SCALE NOT TO SCALE U1.1.0T122 FOR ECWMTEN:9N9 2 ROCK-IT 3.0 COUPLING ASSEMBLY MIGHT,Sae. 81,0 NOT TO SCALE MAX MOUNT SPACING LANDSCAPE MOUNT SPACING•84' CAA,.AnACNMEM,Trp LANDSCAPE CANTILEVER•21' G.MF.A7TACHMENT,TYP PORTRAIT MOUNT SPACING•48' COUPLPIOI TYP . 17/, ' 'TTF PORTRAIT CANTILEVER•16' ER:851 MOURTMO NOTES MOW SPACING:SEE ROOM SLIDE MOUWNONOTEB CLAMP FRMWNG,TYP MODULE,TVP = MODULE 851k MODULE TYP FLAWING r EPDM BONDED WASTER L FORMS WATERTIGHT SEAL �FRAMMG.TYP FRAMING,TVP • , I 4 L4ANOWAPE CLAMP SPACING MESEEZIESECEM 4 PV SYSTEM MOUNTING DETAIL ® MODULES 14 PORTRAIT/LANDSCAPE I -I L•PORTRAR 310 NOT TO SCALE NOT TO SCALE CLAW SPACING COMP SHINGLES 1111 MN 3•MN AND TY MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE ONE NCE STEEL STRAP CONCUR MIN SAW DNA 88 LAO SCREW PV MODULE,TVP,MOUNT A TOROUE•1302 FT4L1111. TO FRAMING OF BEM ROW TTPE,PARALLEL Mr 10\ WITH PLANE OF ROOF - CONDUIT MOUNT BRACKET __ X11 vivint.SQlar r i :A sunrun 1800 ABHTON BLVD.LEHI,�,•101,9 t SECT/ON VIEV( ' 1.077.404.412028FLASHINGFIA0R TEE STRAP MA LIC:77.40.11•SBSA I�' 5 AMAAM.14.1lY44/W2f1.1TA4V,'WA4R:IAMINMIPIZAWr4SM'WY PYRI YYAV W24Pinih1• WARBURTON RESIDENCE ____._. __.�._._.—_—_____—___ 7 CIRCUIT RD E 3 SECTION VIEW WEST YARMOUTH,MA 02 87 3 17 24 31.0 NOT TO SCALE Op PV ARRAY TYP,ELEVATION 7 CONDUIT MOUNTING DETAIL UTILITY ACCOUNT:27151470070 y NOT TO SCALE 81.0 NOT TO SCALE METER:2305284 aJ MOUNT DETAILS °" 113S 1.0 1 ROC:MA-03 SCALE:NOT TO SCALE DRAWN BV:DW t DATE 0412/12021 REVISION:0 9 Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shen be Copper) DC System Size(Watts) 5850 Tag Description Wire Gauge A of Conductors/Color Conduit Type Conduit 5121 e AC System Size(Watts) 3800 1 DC-to-DC Converter Output(PV Wire) 10 AWG 2(V+,V-)B/R Free Air N/A Total Module Count 18 1 EGC(Bare) 6 AWG 1 BARE Free Air N/A § M W r .a+ 2 DC-to-DC Converter Output(THWN-2) 12 AWG 4(2V+,2V-)B/R FMC 1/2" 2 z 0 ..1 2 EGC(THWN-2) 12 AWG SCORN) FMC 1/2" cc C a '1 3 DC-to-DC Converter Output(THWN-2) 12 AWG 4(2V+,2V-)B/R EMT 1/2" f fli 3 EGC(THWN-2) 12 AWG SCORN) EMT 1/2" '0 4 Inverter Output(THWN-2) 12 AWG 3(11,U.N)B/R/W EMT 1/2" ; s.i' 4 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" !it r , Q t11 � ; u C C ear ...- ,y C a- 00. 0 SolarEdge SE3800H-US oFq 'Conforms to ANSI •+ 012.1.2008 .4t PV System SMART Mater Z g Point of Interconnection,Load External Rapid Shutdown Side 705.12(B))3)(2) Disconnect;Square D DU223RB 240V/30A a iz N 1 1 o— _ Unfused,NEMA3terminations with Existing Cutler Hammer «. IA 3 ti 75Y tarminatlons M 240V/125A Service Panel, Z Z H M IS STRING 2:8 PV O O 8 '"' Single Phase,with 100A Main Disconnect SHEET MODULES W/OPTIMIZERS . .""� .�. NAME: `a a __ LINE r 1]OA STRING 1:10 PV 0 © 10 \ MODULESNEMA 3R!unction Box 4 LO'sCI W/OPTIMIZERS . .""" 4 (e1 4 Minimum GEC size 6 OA SHEET Y AW G coppe NUMBER: 18 PV MODULES PER INVERTER•5850 WATTS fVI– STC s V- • a•a nife'PC Disconnect W Inverter/Optimizer Specs PV Module Rating•sic Conductor Calculations Optimizer SolarEdge P370 Module Make/Model Jinko Solar JKM32SM-60HBL DC Input Power 370 Watts Max,Power•PoInt Current(Imp) 9.68 Amps Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature 6 DC Max.Input Voltage 60 Volts Max,Power-Point Voltage(Vmp) 33.6 Volts calculations from Table 310.15(8)(1)&310.15(6)(2)and raceway fill adjustments from 310.15(C) W no DC Max.Input Current 13.75 Amps 0 n{Ircuk Voltage (1).Conduit on the roof shall be Installed no less than 1"above the roof deck. • Yy 0 PW (Voc) 41.1 Volts PV Circuit conductor ampecity Is constrained using the 75'C column with the continuous duty 8 lel DC Max.Output Current 15 Amps Short-Clrcult Current Om) 10.2 Amps uprating or the 90'C column with the relevant ambient temperature and raceway fill adjustments a i 1 Max.string rating inverter dependent.See SE documents. Max.Series Fuse(OCPD) 20 Amps without the continuous duty uprating per 690.8(8),whichever results with a larger wire size. O^ Invertor Make//Model SolarEdge SE360ON-US Nom,Max.Power at STC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity in the 75'C column or the 90'C column with the CEC Efficiency 99 % Max.System Voltage 1000 VDC(UL/IEC) relevant ambient temperature and raceway fill adjustments,whichever is less(110.14(C)& 3 x- 4. AC Operating Voltage 240 Volts Voc Temperature Coefficient -0.26 I %/C 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, Cont.Max Output Current 16 Amps the continuous duty uprated current DC Max Input Current 10.5 Amps ASHRAE 2017-BARNSTABLE MUNICIPAL More Information about conductor calculations can be provided upon request. Input Short Circuit Current 45 Amps Highest Monthly 2%D.B.Design Temp.:29.5'C Calc.Ex:Wire Amrpacity x Ambient Temp.Corr.Factors Conduit Fill Adj.Factor Output Current Max Output Fault Current 17.5 A/20 ms Lowest Min.Mean Extreme D.8,:-19.2'C (Tag 1 Under Array): DC-to-DC Converter Output:10 AWG rated 30 A, 30 A>•18.75 A i s Output Cask:705.12(B)(3)(2) (Tag 2 Attic). C3 Power Source (s) PDC-to-DC Converter Output:12 AWG rated 30 A, 30 A x 0.76 x 0.8.18.24 A s=15 A e' (Tag 3 On Roof): Main Bus Rating:125 Amps DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>•18.75 A •• `14. ; Main Service Breaker Rating:100 Amps (Tag 4 Exterior): C PV Uprated Output Current:20 Amps Inverter Output 12 AWG rated 20 A, 20 A s•20 A •�� ` 100A+20A<.125 x 1.2;120<=150A,OK ' S . .` < tv I N •S Other Notts •Designed according to and all code citations are relevant to the 2020 National Electrical Code. •All interior raceways carrying DC current shall be metallic. es Voltage and OCPD Calculations(690.7,690.9) i a a: PV Source Max Circuit Voltage:Module Voc x(1-(AT x Voc Coeff))(art.690.7(A)] JKM325M-60HBL:41.1 V x(1-((25 C--19.2 C)x-0.28%))•46.19 V<.60 V F 1 ti `v3 Inverter Output Circuit(s):Listed Output Current x 1.25[art.690.9(8)) SHEET Inverter 1:SE3800H-US Max Output=16 A x 1.25•20 A<=20 A(OCPD) NAME: System output current w/continuous duty•20 A<.20 A(System OCPD) I SHEET NUMBER: tV to All AC Disconnecting Means-AC Disconnect(s), Conduit,Raceways,and J-Bones(Labeled Every 10')and Installed within 3 ft of Rapid Shutdown Switch,Reflective,and shall be placed on Combiner Panels and Load Centers• r 690.54 Inverter l DC Disconnect• r 690.53 Reflective per 690.31(0)(2) both Panel Exterior&next to Main Disconnect• r• r 690.5.C 2 PHOTOVOLTAIC AC DISCONNECT " MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCHMAXIMUM AC OPERATING CURRENT: ICA g O OF PV SYSTEM: 480 PHOTOVOLTAIC POWER SOURCE FOR SOLAR PV SYSTEM NOMINAL AC OPERATING VOLTAGE: 240V . S LliPV S stem Disconnects•er 690.13 B PV with Rapid Shutdown Switch,Installed within 3 ft of Service Disconnecting f O^ Means with min.3/8"black capitalized text on yellow background&3/16" 3 y 4- PV SYSTEM DISCONNECT biackca•itallzedtextonwhiteba-•round••r690.5•C i' r_ TURN RAPID SHUTDOWN § AIL p a SWITCH TO THE R "OFF"POSITION TO } U SHUTDOWN PV SYSTEM �, { AND REDUCE C c SHOCK HAZARD § •� " IN ARRAY . a; c a Plaque/Directory at Service Equipment Location and Power Production System Disconnecting f v i 1 CAUTION: MULTIPLE SOURCES OF POWER Discon Disconnecting Load Centers,a dCC&obiner POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE Panels•er690,13 B &690.15 C FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS ELECTRICAL SNOOK HAZARD SHOWN TERMINALS ON THE LINE AND .-i LOAD SIDES MAY BE ENERGIZED ,.. - IN THE OPEN POSITION y_rt I Power Source Output Connection,Adjacent to z a ' Back fed Breaker•=r 705.12 B 3 2 i 1 METER AND MAIN POWER SOURCE OUTPUT CONNECTION SHEET~ - i SERVICE DO NOT RELOCATE NAME / ,1\ I I I ! 1 \ G Y ll" THIS OVERCURRENT PROTECTION DEVICE I ; j ] �' ' \ I AC DISCONNECT Dual Power Sources In Main Service Panel g� 1 and Sub Panel s ••-r 705.12 C ••SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER 3 7E \ll' DC DISCONNECT LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED 666 1 1i PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY SIGNS AND LABELS• SHEET _j . DUAL POWER souecc SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING NUMBER: SOURCES:UTILITY GRID REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO fM) WITHSTAND THE ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS W MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCH SITE PLACARD SHOWING ADDITIONAL POWER SOURCE WARNING C. 4 AND DISCONNECT LOCATIONS.PLACARD SHALL BE 10 DUAL POWER SOURCE OF PV SYSTEM •"V FOR SOLAR PV SYSTEM SOURCES:UTILITY GRID L+ MOUNTED ON EXTERIOR OF ELECTRICAL PANEL AND PV SOLAR ELECTRIC SYSTEM E N WARNING MAIN BREAKER DE-RATED ~ v ( L J PHOTOVOLTAIC POWER SOURCE () SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND q DUE TO SOLAR CIRCUITS WITH RAPID SHUTDOWN ® LOAD SIDES MAY BE ENERGIZED 1 "'AMPS MAX ALLOWED 1 11/ IN THE OPEN POSITION DO NOT UPGRADE 3 sT t �\ PHOTOVOLTAIC AC DISCONNECT WARNING g C PV SYSTEM DISCONNECT ( �j ; MAXIMUM AC OUTPUT CURRENT:"'A POWER SOURCE OUTPUT CONNECTION �� NOMINAL AC OPERATING VOLTAGE:•"V DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE s_ .t p ROOFTOP ARRAY 4 ..... 0 • >_ > i 0 ®IF APPLICABLE •' N 1 4 O © INSIDE m O 0 PANEL ., OS pp 6 6 OS 0 O O Q EVERY 10'AND -, , a WITHIN 1'OF ELBOWS S "\,, DISCONNECT M O — 0DC ii cc INSIDE O y z ., ,7S —" SHEET COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE NAME: ROOFTOP SOLAR INVERTER JUNCTION BOX I (WHEN USED) DISCONNECT(WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) "•-value calculated for each ilL TYPICAL SOLAR GENERATION INSTALLATION account,for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page SHEET NUMBER: •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY SIGNS AND LABELS•SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE a ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS Ly BONDING NOTES em..-BONDING PATH MODULE FRAME ROCK-IT COUPLING MID CLAMPS --Ajl, II iii 4 4 1 ���1 `"ii A ` ROCK-IT ROCK-IT SLIDE UL2703:2015 LISTED PEDESTAL �