Loading...
HomeMy WebLinkAboutPLANSLOCUS #143 EXISTING 2-BEDROOM DWELLING EXISTING 1,000 GALLON SEPTIC TANK TO BE USED IN THIS DESIGN EXISTING SAS (APPROXIMATE LOCATION ONLY) TO BE REMOVED & REPLACED w/ CLEAN COARSE SAND MAP 25 LOT 23 13,500± S.F.PAWKANNAWKUT DR IVE(40' W IDE LAYOUT) Benchmark Nail Set in 22" Tree Elev. = 7.71' NAVD 88 THRESHOLD EL.=7.6'± FENCE (T Y P )EDGE OF PAVEMENT 6x2' TP 1 L.P. COBB L E S T O N E W A L K PROPOSED INSPECTION PORT WITH ACCESS BOX TO GRADE PROPOSED TOTAL 20 ARC 36 (Model #3613) PLASTIC CHAMBERS IN A FIELD CONFIGURATION PROPOSED DISTRIBUTION BOX PROP. 40 MIL. IMPERVIOUS GEOMEMBRANE LINER; TOP EL.=8.78'; BOT EL.=3.78' PROPOSED 1,000 GALLON H-10 PUMP CHAMBER REMOVE ALL UNSUITABLE MATERIAL DOWN TO TOP OF "C" SOIL & REPLACE WITH CLEAN COARSE SAND PER 310 CMR 15.255(3) PROP. 3' HIGH (MAX.) RETAINING WALL PROPOSED 4" SCH. 40 PVC VENT PIPE DEWATERING SEDIMENT TRAP FOR PUMP CHAMBER & SAS EXCAVATIONS (see detail). CONTRACTOR TO ENLARGE SIZE, SHOULD IT BE NECESSARY DURING CONSTRUCTION (DO NOT ENCROACH WITHIN 50-FT WETLAND BUFFER ZONE) WORK LIMIT LINE ~COB B L E S T O N E D R I V E ~S22° 56 ' 00"E96.72 ' N78° 45' 4 0 " E 208'± N67° 0 4' 0 0 " E 163'± MAP 25 LOT 25 MAP 25 LOT 24 MAP 25 LOT 23 U.P.#388/19 APPR O X.M.P.#137 EXISTING DWELLING VEGET A T I O NLANDSCAPE AREA BUSH E S VEGE T A TI O N GUYW I R E LAND S C A P E A R E A THRESHOLD EL.=7.4'± BREE Z E W A Y 5 6 66 6 6 6 667 67 7 6 7 66 7L.P. L.P. 5x2' 5x2' 5x2' 5x3' 5x6' 5x8' 5x2' 5x9' 5x6' 5x4' 6x9'100' COASTAL BANK OFFSETEXISTING ELECTRIC LINE TO BE ROUTED AROUND SAS 70' COASTAL BANK OFFSET~COB B L E S T O N E D R I V E ~BUSHES6 5x9' LANDS C A P E A R E A 6 9 9 6 9x9' 9x9' 9x6' 9x6' 9x6' 9x6' 7 7 RESERVE AREA2nd FL . BALCONYCONCRETE PAD FLA G S T O N E W A L K FLAG S T O N E W A L K SHOW E R BUSH E S BUSHE S FLAG S T O N E W A L K 8" PINE 15" HOLLY 39.7' 27.7'4.5'12.8'16.0 ' (ex .)55SHED (144 sf) GAZE B O (115 sf ) 50.9' (ex.) EXIST. HOUSE PEAK EL.=35.0'± CHIM. 1 STORY GARAGE PROPOSED 7.5' x 20' TWO (2) STORY LATERAL ADDITION34.3 ' 5.0' 7.5' PROP. G A S FIREP L A C E16.0 ' (pr .) 50.9' (pr.)100' INNER RIPARIAN200' OUTER RIPARIAN15.6 ' EXIST. 2nd FLOOR BALCONY TO BE REMOVED & REPLACED w/ NEW EXTENDED BALCONY AS SHOWN IN HATCH HAYBALESWORK LIMIT LINE PROPOSED 5' x 34.3' 2nd FLOOR BALCONY (172 sf)200' OUTER R IPAR IAN 22.1'15.2 '20.0 ' DESIGN DATA EXISTING GAS LINE JLCChecked By:MCP Designed By:JOB No. 6237Drawn By: 40 FEET LOCATED AT PREPARED FOR: CAPE COD OZ PROPERTY II, LLC 143 PAWKANNAWKUT DRIVE SOUTH YARMOUTH, MA 02664 201005 1 INCH = 10 FT. 508.273.0377 PREPARED BY: JC ENGINEERING, INC. EAST WAREHAM, MA 02538 DATE: JUNE 18, 2022 2854 CRANBERRY HIGHWAY SCALE: PROPOSED ADDITION & SEPTIC PLANP.B. 181, PG.125EXISTING CONTOUR50 EAST FALMOUTH, MA 02536 EXISTING 1,000 GALLON SEPTIC TANK RESERVED FOR BOARD OF HEALTH USE 17.DEED REFERENCE: BOOK 31058, PAGE 119 SCALE: 1" = 1000' LOCUS PLAN SCALE: 1" = 10' SITE PLAN DESCRIPTIONAPP'D.DATEREV.BY ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM INSTALLATION AND ADDITION CONSTRUCTION. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 50x0' 50 20. 19. PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED DISTRIBUTION BOX EXISTING UNDERGROUND ELECTRIC TEST PIT LOCATION EXISTING SPOT GRADE PROPOSED CONTOUR LEGEND PLAN REFERENCE: PLAN BOOK 181, PAGE 125 LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. OWNER OF RECORD: ASSESSOR'S MAP 25 LOT 23 PROPOSED PROJECT IS LOCATED WITHIN: CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION THROUGH DIG-SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. ELEVATIONS BASED ON NAVD 88 DATUM. SEE BENCHMARK LOCATION AND ELEVATION AS SHOWN ON PLAN. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. COMMUNITY PANEL # 14. ADDRESS: 18. FEMA FLOOD ZONE 16. 15. 13. 11. 10. 8. 9. 7. 6. 25001C0588J CAPE COD OZ PROPERTY II, LLC AE (EL.11) 169 METOXIT ROAD SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 8.78' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. GENERAL NOTES 5. 4. 3. 2. 1. A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3" OF FINISH GRADE. A REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS. 21. PROPOSED SPOT GRADE50 EXISTING WATER LINETOTAL DESIGN FLOW GAL/DAY DESIGN FLOW GAL/DAY/BEDROOM NUMBER OF BEDROOMS (DESIGN) 110 330 USE EXISTING GALLON SEPTIC TANK1,000 DESIGN FLOW x 200 % = GAL/DAY660 3 12.ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 22. MCP TEST PIT DATA 0" C.S.E. APPROVAL DATE:Oct. 27, 1999 PERC NO.N/A EVALUATOR: Michael Pimentel, EIT, CSE PERC RATE = April 28, 2022 ELEV WATER = TEXTURAL CLASS: DEPTH OF PERC = TEST PIT #: ELEV TOP = DATE: I 1 ' INSPECTOR: Jay Gardiner (BOH) 6.20' 6.20 30"3.70' 92"-1.47' C Med. to Coarse Sand 2.5Y 6/4 (5-10% gravel) Fill Standing @ 54"54"1.70' Mottling @ 42"42"2.70' TEE TEE 3" 2" SCH. 40 TO D-BOX 9" MIN.21" MIN. (TYP) 7.2'±F.G. OVER TANK EL.= @ FND. EL.= PROP. LENGTH WIDTH DEPTH 9" 14"L=13'± 1,000 GALLON H-10 PUMP CHAMBER1,000 GALLON SEPTIC TANK 8'-6"4'-10"5'-8" SLOPE @ 1% min. 40 PVC 4" SCH.3"6"36" MAX. 3" DROP MAX.13"PROP. 1,000 GAL. H-10 PUMP CHAMBER TEE 48" LIQUID LEVEL INV. OUT= OFF PUMP PUMP ON ALARM ON F.G. OVER P.C. EL.= NOT TO SCALE EXISTING 1,000 GAL. SEPTIC TANK & TANK SHALL BE INSTALLED ON A LEVEL STABLE BASE 6.9' - 7.0' 4.75' 5.00' 7.2'± FINISH GRADE 2" DROP MIN. ALL TEES TO BE LINED UP DIRECTLY UNDER CENTER OF RISER OPENINGS F.F. EL. =7.6'± EL.=0.42' EL.=6.08'10"GW @ EL.=2.7'± PROVIDE EXTENSION RISER OVER OUTLET COVER TO F.G. (TYP. FOR S.T. AND P.C.) 22" ZABEL FILTER MODEL # A1801-4x22 (GAS BAFFLE ON BOTTOM) 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE (FOR PUMP CHAMBER) DISCONNECT PROVIDE WATER-TIGHT SEAL AT ALL PIPE PENETRATIONS (TYP) JUNCTION BOX EL=1.75' EL=2.20' EL=2.75' (DIMENSIONS PER ACME-SHOREY) EL.=0.75' PROVIDE EXTENSION RISER WITH COVER OVER INLET TO WITHIN 6" OF F.G. (TYP. FOR S.T. AND P.C.) 9" MIN. 1" BASE. FIRST TWO FEET OF OUTLET CROSS SECTION VIEW DISTRIBUTION BOX DETAIL NOT TO SCALE PIPES TO BE LAID LEVEL. OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE 2" PVC TEE FINISH GRADE OVER D-BOX = REMOVABLE WATERTIGHT RISER 36"MAX. 5" DIA. OUTLET(S) 5 8.40'8.57' 9.9'± TO WITHIN 6" OF FINISHED GRADE 12" MIN.6" 4" PVC OUT TO SAS 40 MIL GEOMEMBRANE LINER, BOTTOM ELEV. = 3.78' (MAX.) 40 MIL GEOMEMBRANE LINER, TOP ELEV. = 8.78' (MIN.) 13" 11.5' INSPECTION PORT WITH ACCESS BOX TO WITHIN 3" OF F.G. (SEE PLAN FOR LOCATION) 7.13" (TYP) 4" SCHEDULE 40 PVC MIN. SLOPE 1%FINISHED GRADE OVER CHAMBERS = SLOPE @ 2% MIN. (TYP.) 9.9' - 9.6' NOT TO SCALE 2.7' (mottling) 5' MIN. (REQ'D) TOP OF SAS / B.O. = GROUND WATER ELEV.= 8.78' CHAMBER END VIEW 8.29' 0.59' 25.0' 5.0' (TYP.) CHAMBER PROFILE 1.08' (TYP.) 2.875' (34.5")7.70'(STONELESS SYSTEM) (min.) 5.0' ARC 36 CHAMBERS (Model #3613) 36" MAX. 9" MIN. FILTER FABRIC NOTE #1: DRAPE THE FABRIC TO COMPLETELY COVER THE LOUVERED SIDEWALLS OF THE CHAMBERS TO PREVENT SOIL INTRUSION. FABRIC: SPUN BONDED, MADE UP OF NYLON FIBERS, HYDROPHILIC IN NATURE • WEIGHT: 0.35 - 1 OZ/YD2 LINER TO BE INSTALLED AROUND SAS PERIMETER*CONTRACTOR TO VERIFY EXISTING ELEVATION PRIOR TO ANY WORK & NOTIFY ENGINEER IF DIFFERENT. EXISTING SEWER *5.3'± PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE NOTE: EFFECTIVE LEACHING AREA OF 4.80 SF/LF OBTAINED FROM THE DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR WATER TECHNOLOGIES, LLC., MODIFIED JUNE 12, 2015. TRANSMITTAL # X264258. SYSTEM CAPACITY (TOTAL L.F. OF CHAMBERS) (4.8 SF/LF) (0.74 GPD/SQ.FT.) = GPD (100') (4.8 SF/LF) (0.74 GAL/SQ.FT.) = 355.2 GAL. LEACHING / DAY TOTALS: TOTAL NUMBER OF CHAMBERS: 20 TOTAL LEACHING AREA: 480.0 TOTAL LEACHING CAPACITY: 355.2 INSTALL 20 - ARC 36 (#3613BD) CHAMBERS PROPOSED 1,000 GALLON H-10 PUMP CHAMBER PROPOSED 2" SOLID SCHEDULE 40 PVC FORCEMAIN SHEET 1 OF 2 PROVIDE FILTER FABRIC OVER ENTIRE LEACHING FACILITY (SEE FABRIC NOTE #1 BELOW) PROPOSED ARC 36 (#3613BD) CHAMBER 30" - 48" < 2 min./inch 2.70' WRACK EL.=2.0'± M.H.W. EL.=1.4'± 12" NUMBER OF BEDROOMS (EXISTING)2 Perc 48"2.20' CONTRACTOR TO CONTACT YARMOUTH HEALTH DEPARTMENT TO PERFORM OPEN HOLE INSPECTION OF SAS PRIOR TO PLACING CLEAN COARSE SAND PER 310 CMR 15.255(3). *SUBJECT PROPERTY IS NOT LOCATED WITHIN A ZONE II. 4 CHAMBERS WIDE Ownership; Add house addition, fireplace, balcony, etc.JLC11-16-222 MCP RET. WALL TO BE CONSTRUCTED AROUND SAS PERIMETER Remove 1-ft g.w. variance request & add reserveJLC10-8-221 MCP #143 EXISTING 2-BEDROOM DWELLING #137 EXISTING DWELLING GARAGE PAWKANNAWKUT DR IVE(40' W IDE LAYOUT) HC-1 (1) GC-1 (2)14.0 '25.0 ' 25.0' 10.0'11.5 ' (3) (4) (6) (5)16.7'11.5 ' 24.9'25.0 ' 11.5' 10.2' 18.0' RESERVE AREA #143 EXISTING 2-BEDROOM DWELLING EXISTING 1,000 GALLON SEPTIC TANK TO BE USED IN THIS DESIGN EXISTING SAS (APPROXIMATE LOCATION ONLY) TO BE REMOVED & REPLACED w/ CLEAN COARSE SAND MAP 25 LOT 23 13,500± S.F.PAWKANNAWKUT DR IVE(40' W IDE LAYOUT) Benchmark Nail Set in 22" Tree Elev. = 7.71' NAVD 88 THRESHOLD EL.=7.6'± FENCE (T Y P )EDGE OF PAVEMENT 6x2' TP 1 L.P. COBB L E S T O N E W A L K TOP OF COASTAL BANK / WOOD-PILE BULKHEADPARKERS RIVER(M.H.W. EL.=1.4'±)(TIDAL)PROPOSED INSPECTION PORT WITH ACCESS BOX TO GRADE PROPOSED TOTAL 20 ARC 36 (Model #3613) PLASTIC CHAMBERS IN A FIELD CONFIGURATION PROPOSED DISTRIBUTION BOX PROP. 40 MIL. IMPERVIOUS GEOMEMBRANE LINER; TOP EL.=8.78'; BOT EL.=3.78' PROPOSED 1,000 GALLON H-10 PUMP CHAMBER REMOVE ALL UNSUITABLE MATERIAL DOWN TO TOP OF "C" SOIL & REPLACE WITH CLEAN COARSE SAND PER 310 CMR 15.255(3) PROP. 3' HIGH (MAX.) RETAINING WALL PROPOSED 4" SCH. 40 PVC VENT PIPE DEWATERING SEDIMENT TRAP FOR PUMP CHAMBER & SAS EXCAVATIONS (see detail). CONTRACTOR TO ENLARGE SIZE, SHOULD IT BE NECESSARY DURING CONSTRUCTION (DO NOT ENCROACH WITHIN 50-FT WETLAND BUFFER ZONE) WORK LIMIT LINE ~COB B L E S T O N E D RI V E ~S22° 56 ' 00"E96.72 ' N78° 45' 4 0 " E 208'± N67° 0 4' 0 0 " E 163'± MAP 25 LOT 25 MAP 25 LOT 24 MAP 25 LOT 23 U.P.#388/19 APPR O X.M.P.#137 EXISTING DWELLING VEGET A T I O NLANDSCAPE AREA BUSH E S VEGE T A T I O N GUYW I R E WRACK LINE EL.=2.0'±LAND S C A P E A R E A THRESHOLD EL.=7.4'± BREE Z E W A Y 5 6 66 6 6 6 667 67 7 6 7 66 7L.P. L.P. 5x2' 5x2' 5x2' 5x3' 5x6' 5x8' 5x2' 5x9' 5x6' 5x4' 6x9'100' COASTAL BANK OFFSETEXISTING ELECTRIC LINE TO BE ROUTED AROUND SAS 70' COASTAL BANK OFFSET~COB B L E S T O N E D R I V E ~BUSHES6 5x9' LANDS C A P E A R E A 6 9 9 6 9x9' 9x9' 9x6' 9x6' 9x6' 9x6' 7 7 RESERVE AREA2nd FL . BALCONYCONCRETE PAD FLA G S T O N E W A L K FLAG S T O N E W A L K SHOW E R BUSH E S BUSHE S FLAG S T O N E W A L K 8" PINE 15" HOLLY ~WOODEN DECK~39.7' 27.7'4.5'12.8'1.8'16.0 ' (ex .)55SHED (144 sf) SHED (73 sf) GAZE B O (115 sf ) 50.9' (ex.) 8.3' 8.8' EXIST. HOUSE PEAK EL.=35.0'± CHIM. 1 STORY GARAGE PROPOSED 7.5' x 20' TWO (2) STORY LATERAL ADDITION34.3 ' 5.0' 7.5' PROP. G A S FIREP L A C E16.0 ' (pr .) 50.9' (pr.)100' INNER RIPARIAN200' OUTER RIPARIANM.H.W. LINE EL.=1.4'±15.6 ' EXIST. 2nd FLOOR BALCONY TO BE REMOVED & REPLACED w/ NEW EXTENDED BALCONY AS SHOWN IN HATCH HAYBALESWORK LIMIT LINE PROPOSED 5' x 34.3' 2nd FLOOR BALCONY (172 sf)200' OUTER R IPAR IAN 22.1'15.2 '20.0 ' PROPOSED SEPTIC SWING-TIES & DIMENSIONS SCALE: 1" = 20'P.B. 181, PG.125SCALE: 1" = 10' SITE PLAN NOTES: 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. CONTRACTOR TO CONTACT YARMOUTH HEALTH DEPARTMENT TO PERFORM OPEN HOLE INSPECTION PRIOR TO PLACING CLEAN COARSE SAND PER 310 CMR 15.255(3). 3.) ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II. 4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. 5.) MEAN HIGH WATER ELEVATION, AS SHOWN ON THIS PLAN, WAS BASED ON NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION (NOAA) VDATUM SOFTWARE. 6.) ELECTRIC LINE FROM PUMP CHAMBER TO CONTROL PANEL AT THE BUILDING SHALL BE INSTALLED BY THE CONTRACTOR. ELECTRIC LINE TO BE ROUTED FROM PUMP CHAMBER TO BUILDING WITH THE LEAST AMOUNT OF DISTURBANCE TO THE PROPERTY AS POSSIBLE. 7.) LOCATION OF ALL ELECTRIC LINES SHOWN ON THIS PLAN IS APPROXIMATE ONLY. CONTRACTOR TO VERIFY LOCATION AT TIME OF INSTALLATION. 8.) SEE ARCHITECTURAL PLANS PREPARED BY OTHERS FOR ADDITION DETAILS AND SPECIFICATIONS INCLUDING INTERIOR RENOVATIONS. RING OF DOUBLE STACKED AND ENTRENCHED STRAW BALES 1" x 2" x 3' OAK BEANPOLES, 2 PER BALE BINDING WIRE OR TWINE FILTERED RUNOFF EROSION/SILTATION FENCE TO BE INSTALLED CONTINUOUS PIECE OF GEOTEXTILE FABRIC TO BE INSTALLED OVER SEDIMENT TRAP HOSE FROM DEWATERING PUMP SILT FENCE ACCUMULATED SEDIMENT CROSS SECTION OF DEWATERING SEDIMENT TRAP NOT TO SCALE DEWATERING FILTER FABRIC BAG TO BE CLAMPED TO END OF HOSE NOTES: 1.) CONTRACTOR TO SIZE UP THE TRAP AS NECESSARY TO HANDLE DEWATERING OPERATIONS. 2.) CONTRACTOR SHALL NOTIFY CONSERVATION COMMISSION AGENT PRIOR TO START OF ANY WORK ON THIS PROJECT. BUOYANCY CALCULATIONS PROPOSED 1,000 GAL. H-10 PUMP CHAMBER HIGH GROUNDWATER EL.= 2.7' TOP OF PUMP CHAMBER EL. = 6.08' BOTTOM OF PUMP CHAMBER EL. = 0.42' WATER DISPLACED = [2.7' - 0.42'] x 8.5' x 4.83' = 94 C.F. WEIGHT OF DISPLACED WATER = 94 C.F. x 62.4 LB/C.F. = 5,866 LBS WEIGHT OF 1,000 GAL. H-10 PUMP CHAMBER = 8,240 LBS SOIL COVER = (6.9' - 6.08') x 8.5' x 4.83' = 34 C.F. WEIGHT OF SOIL ABOVE TANK = 34 C.F. x 110 LB/C.F. = 3,740 LBS 8,240 + 3,740 = 11,980 LBS > 5,866 LBS; THEREFORE ACCEPTABLE STORAGE PROVIDED ABOVE WORKING LEVEL: 500 GAL. STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GAL. (USE 0.45' TO PROVIDE FOR BACKFLOW) 110 GALS/CYCLE 250 GAL/FT = 0.44 FT/CYCLE ON AND PUMP OFF FLOATS: DISTANCE REQUIRED BETWEEN PUMP 330 GPD / 3 = 110 GALS/CYCLE DOSING REQUIRED:3 CYCLES / DAY 330 GPDDESIGN FLOW: DOSING & STORAGE REQUIREMENTS2.00'1.45'1.00'2"SCH. 40 TEE w/ CLEAN-OUT CAP 1/4" WEEP HOLE IN DISCHARGE PIPE 2" SCH. 40 PVC DISCHARGE PIPE 2" SCH. 40 TO D-BOX 1,000 GALLON H-10 PUMP CHAMBER DETAIL4'-7"13"10"6"3" HOISTING CABLE 7 x 19 STAINLESS STEEL 1/8" DIA. / 1,760 LB. STRENGTH 2" BALL VALVE w/ UNIONS SCH. 80 PVC GEORGE FISHER CO. MODEL NO. 560 2" BALL CHECK VALVE SCH. 80 PVC 100 P.S.I. FLOWMATIC MODEL No. 208S BARNES SE411 PUMP; 0.4 H.P.; 115 V; IMP. DIA. 4.25" (MIN.); 2" DISCHARGE PASSING 1-1/2" SOLIDS OR EQUAL. NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID-TIGHT CABLE CONNECTORS SUPPORTED CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT, JOINTS TO BE MADE WATERTIGHT INSTALL 1-1/4" PVC TO HOUSE. JOINTS TO BE MADE WATERTIGHT. WIRE PUMP AND FLOATS TO SIMPLEX CONTROL PANEL No. 1-CC2 NEMA-1 MFG. HOOVER INSTRUMENTS (2) WIDE ANGLE CONTROL FLOATS (BARNES 073618) 1: PUMP ON/OFF 120 ACTIVATION 2: ALARM ACTIVATION NOT TO SCALE NOTE: PUMP MUST BE EQUIPPED WITH A HIGH LEVEL ALARM LOCATED IN THE BUILDING SERVED WHICH IS POWERED BY A CIRCUIT SEPARATE FROM THE CIRCUIT TO THE PUMP. GW @ EL.=2.7'± 17.4' 22.6' 27.6' 16.4' 28.5' 27.5' 36.3' 37.4' SWING-TIES MEASUREMENTS PUMP CHAMBER IN (1) GC-1HC-1DESCRIPTION PUMP CHAMBER OUT (2) CHAMBER CORNER (4) CHAMBER CORNER (3) 33.6' 40.3' 61.9' 61.3'CHAMBER CORNER (6) CHAMBER CORNER (5) EXISTING GAS LINE JLCChecked By:MCP Designed By:JOB No. 6237Drawn By: 40 FEET LOCATED AT PREPARED FOR: CAPE COD OZ PROPERTY II, LLC 143 PAWKANNAWKUT DRIVE SOUTH YARMOUTH, MA 02664 201005 1 INCH = 10 FT. 508.273.0377 PREPARED BY: JC ENGINEERING, INC. EAST WAREHAM, MA 02538 DATE: JUNE 18, 2022 2854 CRANBERRY HIGHWAY SCALE: PROPOSED ADDITION & SEPTIC PLAN EXISTING CONTOUR50 EXISTING 1,000 GALLON SEPTIC TANK 50x0' 50 PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED DISTRIBUTION BOX EXISTING UNDERGROUND ELECTRIC TEST PIT LOCATION EXISTING SPOT GRADE PROPOSED CONTOUR LEGEND PROPOSED SPOT GRADE50 EXISTING WATER LINE MCP PROPOSED 1,000 GALLON H-10 PUMP CHAMBER PROPOSED 2" SOLID SCHEDULE 40 PVC FORCEMAIN SHEET 2 OF 2 PROPOSED ARC 36 (#3613BD) CHAMBER CONTRACTOR TO CONTACT YARMOUTH HEALTH DEPARTMENT TO PERFORM OPEN HOLE INSPECTION OF SAS PRIOR TO PLACING CLEAN COARSE SAND PER 310 CMR 15.255(3). FRONT YARD ZONING REGULATION REAR YARD SIDE YARD BUILDING COVERAGE* ZONING DISTRICT: R-25 19% 12.8' PROP. 39.7' N/A BUILDING HEIGHT < 35' 17% 12.8' EXIST. 39.7' N/A < 35' 25% MAX. 15' MIN. REQ'D 30' MIN. 20' MIN. 35' MAX. DESCRIPTIONAPP'D.DATEREV.BY Ownership; Add house addition, fireplace, balcony, etc.JLC11-16-222 MCP Remove 1-ft g.w. variance request & add reserveJLC10-8-221 MCP 6" OF 3/4" CRUSHED STONE TO BE PLACED BEHIND AND BENEATH THE WALL 8" H x 18" L x 21.5" W BLOCKS MANUFACTURER CERTIFIES TO HEIGHT OF 6 FEET 6"SEPTICSIDE TRIM CAP WITH CONT. ADHESIVE (AS PER MANUFACTURER'S RECOMMENDATIONS)SLOPE VARIES TOP WALL EL. = 9.9'± (max.) EMBED. 1.5" BURIAL FOR EVERY 1' HEIGHT COMPACTED GRANULAR BASE OR (OPTIONAL CONCRETE LEVELING PAN) HEIGHT VARIES (3' MAX.) KEYSTONE® "STANDARD" RETAINING WALL (TYP) NOT TO SCALE 40 MIL GEOMEMBRANE LINER 1"8"ZONING SCHEDULE RESIDENTIAL PRINCIPAL BUILDING CONSERVATION COMMISSION REQUIREMENTS: 1.) No work of any kind shall occur on the Resource Area side of the work limit line. This line shall be established prior to any construction or work. 2.) All imported fill shall be clean and not contain any foreign debris such as cement, bituminous concrete, rubber, metal, trash, boulders, etc. 3.) Debris, including litter, shall be picked up immediately. Any excess material that is excavated from the job site shall be disposed of at a location approved by the Conservation Administrator or in a covered dumpster. No debris shall be allowed in a Wetland or Waterway. 4.) Washing of equipment/tools shall be done OFF-SITE or handled in a manner appropriate by the Conservation Administrator. 5.) No equipment shall be refueled, nor shall fuel be stored within 100 feet of a resource area. 6.) Any area that is disturbed during construction shall be revegetated immediately or as soon after as the growing season commences. Permanent stabilization shall be carried out in order to minimize erosion. 7.) The proposed sewage disposal system shall meet the applicable Title 5 wetlands setbacks as set forth by the Yarmouth Health Department. 8.) The "work limit" line shown on this plan shall be established with Erosion Controls (i.e. straw bales, staked filter fabric, bark mulch, "silt sacks", products made with rice straw, and other weed-free products or approved by the Yarmouth Conservation Commission). Hay bales are not allowed. The contractor is responsible to implement and maintain appropriate and adequate erosion controls measures throughout the construction process. FRONT YARD ZONING REGULATION REAR YARD** SIDE YARD** BUILDING HEIGHT ZONING DISTRICT: R-25 N/A N/A PROP. N/A N/A BUILDING AREA N/A <1-ST 1.8' EXIST. 27.7' N/A < 150 sf 1-ST. MAX. 6' MIN. REQ'D 30' MIN. 6' MIN. 150 sf MAX. ZONING SCHEDULE RESIDENTIAL ACCESSORY BUILDING **Side and rear yard setbacks for accessory buildings less than one hundred fifty (150) square feet and single story (ST), shall be six (6) feet in all districts, but in no case built closer than twelve (12) feet to any other building *Proposed building coverage includes accessory buildings. RIVERFRONT ALTERATION: WITHIN 100' = 32 S.F. BETWEEN 100' & 200' = 0 S.F.* TOTAL ALTERATION = 32 S.F. TOTAL RIVERFRONT AREA ON THE SITE = 13,500 S.F. *Septic work previously approved by the Yarmouth Health Department. Septic work not included in the above alteration areas.