Loading...
HomeMy WebLinkAbout2022 New Well Drilled 171:1 Massachusetts Department of Environmental Protection Bureau of Resource Protection Well Completion Reports Well Driller Please specify work performed: Address at well location: New Well I Street Number: Street Name: 273 STATION AVE Please specify well type: Building Lot#: Assessor's Map#: Irrigation 78 Assessor's Lot#: ZIP Code: Number Of Wells: 154 02664 City/Town: Well Location YARMOUTH In public right-of-way: GPS Yes r No North: West: 41.67805 70.19898 Subdivision/Property/Description: Mailing Address: click here if same as well location address Property Owner: Street Number: Street Name: FAITH HALLET 273 STATION AVE City/Town: State: Engineering Firm: YARMOUTH MASSACHUSETTS ZIP Code: 02664 Board of health permit obtained: (Yes ai Not Required Permit Number: Date Issued: Nov 18 2022 HEALTH DEPT. LiMassachusetts Department of Environmental Protection Bureau of Resource Protection—Well Driller Program Well Completion Reports(General) Well Driller - General Well Form DRILLING METHOD Overburden Bedrock Auger --Choose Bedrock-- - WELL LOG OVERBURDEN LITHOLOGY l Drop in drill Extra fast or slow Loss or addition I From(ft) 'To(ft) Code Color (Comment stem drill rate of fluid iv j (15 1 Fine To Coarse S + Brown 2....111 1 f Fast C Slow L L_� YES ND — Loss_Addition 15 1125 1 1 Fine To Coarse S I Reddish Brown Fast r Slow YES NO — — ... Loss Addition 1 --------- '25 j [—Fine To Coarse S i Reddish Brown zj C Fast r Slow YES NO ._._.._ _ _. Loss Addition WELL LOG BEDROCK LITHOLOGY From(ft) To(ft) Code Comment j Drop in Extra fast or Loss or Visible Rust Extrga drill stem slow drill rate addition of Staining Lar e fluid Chips 33 i _---,._.....( {( r r' r Choose Code r Yes r Yes YES ND i Fast Slow Loss Addition --- i r ADDITIONAL WELL INFORMATION Developed a Yes r w Disinfected Yes r No Total Well Depth 30 Depth to Bedrock Surface Seal Type None fracture Enhancement r Yes r:No CASING r Is Casing above ground?1 From To Type Thickness Diameter Driveshoe 0 27 It Stainless Steel I Schedule 40 � 4 jr Yes! SCREEN r No Screen [From To Type Slot Size Diameter (27 1 (30 1 Stainless Steel Well Point jj [0.012 1 14 WATER-BEARING ZONES r DRY WELL — From To Yield(gpm) 11 [30 .... .........( 1112 ( PERMANENT PUMP(IF AVAILABLE) Pump Description Horsepower 2 Wire Constant Speed Submersible 3/4 Pump Intake Depth(ft) 26 Nominal Pump Capacity(gpm) 15 Massachusetts Department of Environmental Protection Bureau of Resource Protection—Well Driller Program Well Completion Reports(General) ANNULAR SEAL/FILTER PACK From To Material 1 Weight Material 2 Weight Water Batches Method Of(gal) (count) Placement Choose Material Choose Material 4 —Choose One— WELL TEST DATA Date Method Yield(gpm) Pumped Pumping Level(ft Time To Recover Recovery(ft (gPm) (HH:MM) BGS) (HH:MM) BGS) 10/07/2022 Constant Rate Pump 12 01:30 13 100:01 [11 1 WATER LEVEL Date Static Depth BGS(ft) Flowing Rate(gpm) Measured [10/07/2022 11 12 COMMENTS WELL DRILLERS STATEMENT This well was drilled or altered under my direct supervision,according to the applicable rules and regulations,and this report is complete and accurate to the best of my knowledge. WILLIAM Supervising Driller DESMOND, Monitoring[M] DrillerURQUHART Registration# 877 Signature PATRICK, DESMOND WELL Firm DRILLING INC. Rig Permit# 0089 Date Job Complete 10/17/2022 NOTE:Well Completion Reports must be filed by the registered well driller within 30 days of well completion. NOV 1 8 2U22 HEALTH DEPT, ENVIROTECH LABORATORIES,INC. MA CERT. NO.:M-MA 063 8 Jan Sebastian Drive Unit 12 Sandwich,MA 02563 (508)888-6460 1-800-339-6460 FAX(508)888-6446 Client Name: Desmond Well Drilling Location : Address: PO Box 2783 273 Station Avenue Orleans, MA Yarmouth, MA 02653 Lab Number: DW-224367 Collected By : Desmond Well Drilling Date Received: 10/07/22 Sample Type: Irrigation Well Specs: Location Source Date Collected Time Collected Comments A 10/07122 12:30 Analysis Requested Units Recommended Limits Analysis Result Method Date Analyzed Analyzed By Total Coliform CFU/100mL 0 0 SM9222B 10/07/2022 KF @ 16:45 pH pH units 6.5-8.5 5.53 SM 4500-H-B 10/07/2022 RS Specific.Conductance= umhos/cm 500 520 EPA 120.1 10/12/2022 RS ___-- Nitrite-N mg/L 1.00 <0.006 EPA 300.0 10/08/2022 RS Nitrate-N mg/L 10.0 5.6 EPA 300.0 10/07/2022 RS Sodium mg/L 20.0 77 EPA 200.7 10/08/2022 KB Total Iron mg/L 0.3 0.03 EPA 200.7 10/08/2022 KB Manganese mg/L 0.05 0.102 EPA 200.7 10/08/2022 KB Comments: Low pH indicates high corrosive characteristics. Nitrate level should be monitored periodically. Sodium level is not a health hazard,but if on a low Sodium diet,consult a physician before drinking Over a lifetime,the EPA recommends that people drink water with manganese levels less than 0.3 mg/L and over the short term, EPA recommends that people limit their consumption of water with levels over 1.0 mg/L All samples were analyzed within the established guidelines of US EPA approved methods with all requirements met, unless otherwise noted at the end of a given sample's analytical results. We certify that the following results are true and accurate to the best of our knowledge. Water meets EPA standards and is suitable for drinking for parameters tested. NOV 18 2022 HEALTH DEPT Date 10/14/2022 „finti "('' Ronald J.Saari Laboratory Director BRL=Below Reportable Limits *See Attached Page 1 of 1 ❑Cert f cation is not available for this analyte for potable water samples,.