HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
, 6 SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. ` Lot /02 Zone of Contribution: In_ Out Le Acreage
Commercia • Residential:
Street: 8� ki 4?6, / ye
Village: /Pelt Floor Plan: #Bedrooms:
Owner: 4.d y1 Installer: '4' 'J'`'�� �'
-) Ad
Address: Phone: 77 - 97
Phone:
Builder: Engineer: 2> f (& Eeptal-
Address: 7 Phone: -36 22•--- -S4/
Phone: ��'�tC ' Gild�' L. ''/*
N/A YES NO
1. Required#of copies received - t,,/
2. Date of soils exam and percolation test not older than 2 years 1�
3. 4-5 ft of naturally occurring pervious material, above water table f
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: t./
5. Water line 10 ft from septic components Var.: �f
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: Cy7;S
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: i . )/
9. Leaching minimum 100 ft from wetlands Var.: - ' ' c,/
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well /Var.: c�
11. Tank/leaching minimum 10 ft from property line Var.: c _
12. System meets all other setback requirements Var.: V
13. Uses adjustment for maximum high groundwater Var.: t./
14. Leaching set 4-5 ft above adj. water or botto -of test hole Var.: t<
15. System not in top or subsoil(A,B horizons) r 5' removal- ' i/
16.Proposed contours are suitable ;/
17. System meets slope requirements-min. 1/8", ' "preferred t .
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee ../
20. Sewage is under 10,000 gpd for parcel f _
21.No garbage disposal
-
22. System adequately sized for its intended use t.-/
23. Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6"of grade,pump chamber cover to grade L�
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2" line,weep hole,check valve,tee in dbox,pump size ,..--"#
28. Septic tank/pump chamber to be factory waterproofed t.-------
29. Vent provided if leaching below 3 feet, under driveway/parking :---'
30. Buoyancy calculations for tank/pump chamber `r
31. Engineer to inspect and certify soils: wall: commercial: �---"
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature �'`
33. H-20 loading is subject to vehicular traffic, groundwater E/
34.Title V Application and permit fee, installer signature ✓-
35. Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd_ L-
37. Check area lots for groundwater/Label groundwater in Assessor's Map ---- -
Plan reviewed by: 6/03/03