HomeMy WebLinkAboutReview Checklist J SEWAGE PLAN REVIEW CHECKLIST
Location: AM Pill LOT T/ Date of Subdivision Approval A//r
Street 5 A1EP01-6Ii idl/,EA/UE Zone of Contribution: In X Out
Village YA. ki tou',-1j Commercial Residential X
Owner Ft,k)o% GeRbeti Installer
Builder Engineer bju1.t1(RpE rAzivrEE146
N/A Yes No
1 . Required number of copies received. X
2. Date of soils exam and percolation test not older than 2 years. �C
3. 4 feet of naturally occcurring pervious material. X
4. Foundation 2 feet above high point in fronting road. X
5. Water availability letter from Water Department.
6. Benchmark indicated and shown. )(
7. Building sewer does not exit center of house. )(
8. Septic tank a minimum of 10 feet from house and deck. X
9. Leaching a minimum of 20 feet (10 feet) from house and deck. )e
10. Leaching a minimum of 100 feet from wetlands. X
11 . Leaching a minimum of 150 feet from wells. 1(
12. System meets all other setback requirements. X CAL
13. USGS adjustment used for maximum high groundwater.
14. .Leaching 4 feet above adjusted water table or bottom of test pit. X O .
15. System not in top or subsoil or 10 foot removal. )(
16. Proposed contours are suitable.
17. -System meets slope requirements. X
18. System meets breakout requirement. X
19. Specified tee sizes are proper.
20. Sewage flow not over 10000 gpd. j(
21 . No garbage disposal. X
22. System adequately sized for its intended use.
23. Engineer to certify.
a. Clay removal. x
b. 25 foot removal. X
c. Tight installation. �(
d. Commercial system. �(
24. Engineer and Land Surveyor Stamp and Signature. x
25. H 20 Loading when system is subjected to vehicular traffic. �(
26. Title 5 application and fee signed by licensed installer X
27. Foundation footing 2 feet above adjusted water table. j(
Plan reviewed by j24tf
2/4/88
TH:fs