Loading...
HomeMy WebLinkAbout2022 Sign off Transmittal - Addition r ov'.Y. ,i. TOWN OF YARMOUTH s-tier`j c HEALTH DEPARTMENT 'ty� PERMIT APPLICATION SIGN OFF TRANSMITTAL SHEET To be completed by Applicant: Building Site Location: 717 Willow Street Proposed Improvement: Removing part of house built on slab and replacing with great room addition Applicant: McPhee Associates, Inc. Tel.No.: 508-385-2704 Address: PO Box 799, East Dennis,MA 02641 Date Filed: 8/12/22 **If you would like e-mail notification of sign off,please provide e-mail address: mcphee@mcpheeassociatesinc.com Owner Name: David&Theresa Pearson Owner Address: 3440 Austin Court, Alexandria, VA 22301 Owner Tel. No.: 703-589-8466 RESIDENTIAL AND/OR COMMERCIAL BUILDING HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e., Requirements For Septage Disposal and other Public Health Activities. Please submit three (3) copies of plans, to include: (1.) Site Plan showing existing buildings, water line location, and septic system location; (2.) Floor plan labeling ALL rooms within building (all existing and proposed) — Note:Floor plans not required for decks, sheds, windows, roofing; (3.) If necessary, Title 5 application signed by licensed installer with fee. REVIEWED BY• ,� �q L� �,t,zst. DATE: / 1._PLEASE NOTE - j o COMMENTS/CONDITIONS: N Q 1 1�1 O COr VVT^�11 U Q W � Q U � �f1 O r--f o 0 6" T �$ # x � s O � co O� N Ul o tp � O T'� S S � U Y Z C C z N Q 0 C4 Q w w - U O Z w z z U w �J F z o_ 0 0 x G U z 14 w F Q 0 co m w w G U } A,3 O U N N U a w �i w F PAt, 2022-06-2.4 J Q FRAMING RAMI: REQUIREMENTS MENTS _ STRUCT URAL: • LALLY COLUMNS INSTA LLED TIGHT TO BEAMS &PLATES CONNECTED • POINT LOAD BEARING SOLID BLOCKED AND CONTINUOUS • BASEMENT BEAM HAS SOLID BEARING AT POCKETS, NO WOOD SHIMS • ALL HURRICANE CLIPS, TIE DOWNS HANGERS ETC. INSTALLED & NAILED OFF COMPLETELY • ALL JACKS SHALL BE TIGHT TO STRU.CTLT AL HEADERS, ANY FURRING DOWN OF OPENING SHALL BE BETWEEN JACKS. • JACKS SHALL NOT BEAR ON SILL COMPONENTS, THEY ARE TO RUN CONTINUOUS FROM HEADER TO BOTTOM PLATE ; • CRACKED OR SPLIT STRUCTURAL MEMBERS SHOULD NOT BE USED • LVLS & PSLS IN PLACE PER STRUCTURAL PLANS, TIMBERLOCKED TOGETHER • COLLAR TIES WHERE REQUIRED • CONNECTIONS IN GENERAL ARE TIGHT & SECURE • JOIST SPACED PER PLAN, BEARING AT ENDS • ROOF SHEATHING BROKEN BACK FROM ROOF RIDGE VENT CLEARANCE - SHEATHING TO MEET OVER RIDGE I FOOT FROM GABLE ENDS AND I FOOT BACK FROM INTERSECTION OF RIDGE AT CHECK WALLS/OTHER ROOFS. SHEATHING SHOULD MEET IF NO VENT. GENERAL: • BLOCKING FIRE - AS REQUIRED BY CODE - MID SPAN, ALL WALLS OVER 8 FT. SHOWERS - 2X10 AROUND PERIMETER OF BASE • ROUGH OPENINGS - CHECK FOR CORRECT SIZE, PLUMB AND WIND • MEDICINE CABINETS IF RECESSED ARE THEY FRAMED? • PLYWOOD BREAKS ON JOIST, STUD, OR RAFTERS (NO BLOCKING) • FLOOR PLYWOOD GLUED AND NAILED & CHECKED FOR SOFT SPOTS & SQUEAKS • ALL WALLS - PLUMB, SQUARE, STRAIGHT AND DIMENSIONALLY CORRECT • CABINET AND VANITY WALLS DOUBLE CHECKED FOR STRAIGHTNESS • STRAPPING - NAILED OFF AND STRAIGHT • NAILERS -ALL MISCELLANEOUSNAILERS FOR SHEET ROCK ARE IN PLACE WALL LEGEND LOW FOUNDATION WALL ' 10" x 4'-0" CONC. WALL ON 20" X 10" FIG. 10" x 4'-0" CONC. WALL O 10" SONO TUBE FILLED (min. 48" below finished grade) V.j � � o U W Q �d �w n v t� Q U ¢ -.. ON V PLATFOR M TUB DIM ENSIONS S ARE VER IFIED DCO RRECT IF APPLICABLE ' STAIRS FINISH TREAD THICKNE SS/RISE /RUN / 'WID TH /HEADROOM / SPEC IAL DE TAILS AILS VERIFIED RI D CONFIRM h WALL ST ABILITY • PROVIDE 2X WIND BLOCKING IN RAFTER BAYS, TYPICAL t 28n ' -0 • SKY LIGHTS GH S PADDED FOR SHEET ROCK IF APPLICABLE • STUDS TWISTED OR LOOSE (TOE NAILED) REPLACE AS NEEDED • BOTH TOP - AND BOTTOM WALL PLATES TO BREAK ON STUD S 2 • DU CT CHASES HEADED OFF • JOISTS SPACED FOR PLUMBING TOILET WASTE NEEDS 3 CLEAR • .BATH VAL VE WALLS O HAVE 16 CLEAR BAY CE NTERED FOR VALVE O • SCUTTLES IN PR o - OPER PLACE _ • HEADER HEIGHTS AND DROPPED CE ILING HEIGHTS ARE VERIFIED CORRECT _ o N CV v_ • INTERIOR — _ — O �- O PARTITIONS TIGHT TO STRAPPING — — — — — — � — • INTERIOR BE _ 4 � BEARING PARTITIONS TOP PLATE TI ... .. . .. .. . . GHT TO JOISTS .:• ... .. — • ALL HEADERS, JACK /STUD COMBOS &CORNERS SHALL BE NAILED . •: • ' I •; — — T —. — — — — — — — — 1 11 _ THROUGH BOTH ID _ e� SIDES � 1 - 5 1 6 T.O.F.1.7 ± t n z • .ALL HEADERS TO BE NAILED THROUGH KING STUDS . �': _ 1 2 1/8 " „, 80 • ( FROM SILLS . , ) 10 x4 - � r - TO BE TOE NAILED TO JACKS AS WELL AS NAILED TO CRIPPLES 0 CONCRETE40 .. 1ST FLR ROUGH V.I.F. • �- ALL WALL .. � PLATES SHALL BREAK ON STUD LAYOUT WALL M. • EXTERIOR WALL BOTTOM PLATES TO BE SEALED TO DECK WITH I - CONSTRUCTION AD „ ADHESIVE I 10 x20„ CONT. FOOTING •• • _ a` • O O RIGID G INSULATION TO BE INSTALLED IN EX TERIOR WALL PARTITION ( KEYWA • W _ / Y TYP. BACKERS & IN HEADERS 2X6 WALL IN LIEU OF PLYWOOD x . T • FRAME IN VESTIBULE AT BULKHEAD AND INSTALL . PLYWOOD ON BULKHEAD " I FR AME IN TILED SH OWER HEADERS WHERE APPLICABLE • INSTALL AL VERTICAL 1x5 KOMA ON EITHER SIDE OF OVERHEAD.: GARAGE - DOORS AS WELL AS ABOVE - i K1 TO RECEI VE TRACKS AND OPENER SPRINGS. .. - — T� � co INCLUDE ALL RELATED BLOCKING ; I BEAM POCKET 1„ OC SET _ -- m i • 3 a LALLY EXTERIOR TRIM &MILLWORK: I �. W/30"00"xff' / 3tt 2" FOOTING, TYP. • PAINTED TRIM (IF APPLICABLE) IS BACK PRIMED INCLUDING ALL FRESH CUT _ _ `2) 1 4 X 11 8 LVI; EDGES I I— , = '� DROPPED � • PVC TRIM JOINTS TO BE GLUED WITH BOND N FILL OR EQUAL `�'I /I • PVC TRIM TO BE FASTENED W/SCREWS OR HEADED NAILS, NO FINISH NAILS can OR BRADS ( + L _J • NAILS ARE SET FOR PAINT, FLUSH FOR NATURAL TRIM; NAILS SHALL NOT STAND PROUD OF TRIM • TRIM IS STRAIGHT AND TRUE, JOINTS ARE FLUSH, TRIM IS DAMAGE FREE • SOFFIT VENT NEAT AND CONTINUOUS • HOLD TRIM 1/4 INCH AWAY FROM ROOF SHINGLES 1 INCH BELOW THE DROP 81-711 81-711 1. 81-711 21-011 u OF FOUNDATION - r• E" �. • e� TO a _ U E KICKS AT DOORS ARE SUPPORTING SILLS -. = s FRIEZE BOARDS, BOTTOM OF WINDOW CASINGS AND WINDOW APRONS ARE RABBETED ' 4" 1 I c SL / DEEP X I HIGH FOR SIDEWALL SHINGLES, 2ND TO LAST -• _ o v COURSE TO GO UNDER, LAST COURSE TO BUTT TRIM • .FABRICATE RABBETED LIGHT &VENT BLOCKS & TACK IN PLACE FOR FINAL - I INSTALL BY OTHERS I , „ , NEW 3 -0 x3 -0„ OPENING • DOOR LEAD TO HAVE FOLDED - NOT CUT - CORNERS FOLD OL LEAD UP, INSTALL TO NEW C .... , ...... RAWL SPACE TEMPORARY 3/4 (STRAPPING) BOARD &TRIM LEAD ALONG TOP OF STRAPPING • , . - , � . INS I --- TALL WINDOWS WITH FLEX WRAP PANS TO BE FOLDED UP AND STAPLED -: TO INSIDE WINDOW SILL, UNLESS OTHERWISE NOTED — N • INSTALL WINDOWS AND DOORS PLUMB, LEVEL & SHIMMED TO _ , MANUFACTURER S SPECS PRIOR TO INSTALLATION OF EXTERIOR TRIM. • � ' CHECK THAT ALL WINDOWS D — — — • O S & DOORS OPERATE SMOOTHLY • CONFIRM ALL TEMPERED UNITS ARE IN CORRECT LOCATION ' I •. ENTRY DOORS OTHER THAN SLIDERS/PATIO ARE SHIMMED UP FROM 1/" F SUB 2 FLOOR T.O.F . — • _ EL.- 11.16 BUILDING PAPER ALL EXTERIOR TRIM SHALL HAVE TARPAPER BENEATH IT - AT ALL SEAMS WHERE IT MEETS SIDING. ALL ICE & WATER VYCOR ETC. — z SHALL BE INSTALLED SO THAT BUILDING APE — P R CAN BE SLIPPED UNDER IT Q SO OVERLAP IS C t 11 - — CONTINUOUS FROM THE TOP DOWN. DO NOT LEAVE I&W OR _ ► n � .. 15 6 � 12-3 VYCOR STUCK TO THE SHEATHING.. cry — • RETURN AFTER SIDING TO CUT DOWN CORNER BOARDS B � SITE CONDITIONS: •' TIO S. 9 • p A. W REMOVE ALL STAGI NG, UP 12 , TEMPORARY BRACING CLEATS ETC. _ R AUG • ALL LOW SILL HEIGHT SECOND L F OOR WINDOW OPENINGS SHALL HAVE A LHEALTH ZX4 SAFETY RAIL NAILED OVER THE OPENING UNTIL -WINDOW IS SET. D; _wpT_ ALL HOLES IN 1ST AND 2ND FLOORS SHALL BE COVERED OVER FOR SAFET Y; BA LCONIES AND STAIRWELLS SHALL HAVE TEMPORARY RAILS. • ALL MATERIAL SHALL BE KEPT IN NEAT PILES AND JOB SITE SHALL BE CLEANED EACH DAY. ALL LUMBER PILES TO BE COVERED FOR PROTECT ION IF PROJECT IS A RENOVATION EXISTING STRUCT URE TO BE WEATHER TIGHT NIGHT LY ► 1� OF Mq S • ALL TRASH TO BE PUT IN DUMPSTER OR ON -SITE BARRELS. MCPHEE LABOR 1 ,. S ti IS PROVIDED TO EMPTY BARRELS AS NEEDED NOT TO CLEANUP SITE BEHIND. SUBCONTRACTORS. Eto DeANG � PROPOSED FOUNDATI NT �T STRUCTUR ►, O1 � PLA1 � Pdo• 3506 1 I / f11 �O FGt sc�,E. 1r4I I _ 1 0 bAfr-2022 06 2,4