Loading...
HomeMy WebLinkAboutEngineer PlanPLAN REFERENCE: BARNSTABLE COUNTY REGISTRY OF DEEDS PLAN BOOK 138, PAGE 39. 26 85.01' I I i� iw I I I A� Reserve Inspection I _ 211., ort 45.0' _ ®®I I I I S.A.S. l I � I I I i I i ! Pump -out, fill-i72. or remove I D-Box Existing CesspooIs g I i 1,500 Callon i 28.4 Septic Tank 11j 1 20' L Porch Existing 2 Bedroom Dwelling F.H. = 30.0 Rouse #33 —13— co N; LOT 32 951848+/- S.F. I ju z' n 8 .00 —2 Catch a Bash TBM = 24.8 Catch Basin Rim COTTAGE DRIVE LEGEND Exist. Spot Elev............. Exist. Contour ................ 5.3 Prop. Spot Elev.............. 35.9 Prop. Contour ................. 36 Setback Dimension........ 13' Perc. Test Location........ Prop. Water Service...... RE _EIVEp APR 12 2007 LOT COVERAGE LO-r AREA = 9,848S.F. = 100.00% Dwelling = 879 S.F. = 8.92% Porch = 121 S.F. = 1.23% Total = 1,000 S.F. = 10.15% REVISION DATE BY Al SITE & SEWAGE Z NOSSMA GRflSSMAN � No. 12705CIVIL DISPOSAL PLAN. "LISTE �da a LOT 329 #33 COTTAGE DR. �3sf0At��� toteage Dr WEST YARMOUTH, MA. � ...� APPLICANT: "°S ENGINEER: �oss Todd Prada Norman Grossman, PE, RLS No. 12775 33 Cottage Drive 27 Nichols Road West Yarmouth, MA East Falmouth, MA 02536 LOCUS MAP 508-548-1920 MAP SE DAR LOT ZONE. FLOOD ZONE MAP SCALE I DATE SHEET NO. PLAN NO. 39 77 33 1 R3 I C 125009 0007 F 1" = 20' 1 Mar. 23, 2007 1 OF 2 I H-997-1 FIRST FLOOR ELEVATION 30.0 TOP FOUNDATION ELEVATION_ 29.2 INVERT AT FOUNDATION ELEVATION 27.10 (VERIFYINFIELD PRIOR TO START OF INSTALLATION) BASEMENT FLOOR ELEVATION 11"Unzaa1w.13 FIN. GRADE AT FIN. GRADEOVER FOUNDATION SEPTIC TANK 29.0 28.4 RISERS SET TO WITHIN 6" OF FINISHED GRADE 3" 26.7 1,500 GALLON SEPTIC TANK H- 10 LOADING IGAS BAFFLE ON OUTLET TEE NUMBER OF BEDROOMS ................... 3 G.P.D./BEDROOM ................................ 330 G.P.D. TOTAL DAILY FLOW ............................ 330 G.P.D. GARBAGE DISPOSAL .......................... NO LEACHING REQUIRED ........................ 330 G.P.D. LEACHING PROVIDED ........................ 333 G.P.D. SEPTIC TANK REQUIRED ................... 1500 GAL. SEPTIC TANK PROVIDED ................... 1500 GAL. SIDEWALL AREA ................................. --- S.F. BOTTOM AREA .................................... 450 S.F. TOTAL AREA ........................................ 450 S.F. TOTAL AREA X 0.74 G.P.D./S.F ........... 333.0 G.P.D. SEPTIC SYSTEM PROFILE NOT TO SCALE J TANK , TO BE SET LEVEL AND TRUE TO GRADE ON 6" C RUSHED STONE BASE ON MECHANICALLY COMPACTED NATURAL MATERIAL Mulmmg�11 FIN. GRADE OVER DISTRIBUTION BOX ,28.4 2" 6" 26.50 1 /'11 } = SuT, vixen m RISER SET TO WITHIN 6" OF FINISHED GRADE 26.28 F 2 6.05 9 HOLE DIST. BOX H- 10 LOADING TO BE SET ON A LEVEL AND STABLE BASE INVERT LEVELERS ON ALL OUTLETS ATE OF TEST: 03/22/07 OGGED BY: JE LANDERS-CAULEY 7ITNESSED BY: AMY VAN HONE OWN OF: YARMOUTH ERC RATE: <2 MIN/IN DIL CLASS: 1( 0.74 GALS./S.F.) ROUND WATER: NONE ENCOUNTERED TEST PIT #I EL. 28.4 5" FILL 0/ LOAMY SAND 7" A/E 10YR 5/6 LOAMY SAND 27 1 B IOYR 5/8 MEDIUM SAND 10 11 C-1 I OYR 6/6 MEDIUM TO FINE SAND 122 C-2 I OYR 6/4 26.15 V 19.4 18.25 No MOTTLING TO 108" (EL. 19.4) NOTES: FIN. GRADE OVER SOIL ABSORPTION SYSTEM 28.3 INSPECTION PORT 2" DOUBLE -WASHED 1/8" - 3/4" PEASTONE OR APPROVED GEOTEXTILE FABRIC - - - - - - LL 6" DOUBLE/-WASHIE 1-1/2" CRUSH TO CROWN OIP 10, 45' 9 DIST. LINES 2 5'0" O.C. = 40' 2.5' 6" DOUBLE -WASHED 1-1/2" CRUSHED STONE TO CROWN OFFERF, PIPE LEACHING FIELD (Not to Scale ) SOIL ABSORPTION SYSTEM 26.5+/- END CAP on EACH LINE F-26.00 WI&MOR 1. ELEVATIONS BASED UPON ASSUMED DATUM. OAb4, ­ 2. TOPOGRAPHY BASED UPON AN ON -THE -GROUND SURVEY. OF 3. PROPERTY LINE INFORMATION FROM BOOK 138, PAGE 39. 4. NORTH ARROW NOT TO BE USED FOR SOLAR ORIENTATION. 5. ALL PIPING TO BE CAST IRON OR SCHEDULE 40 PVC. :�Y NOJ9%iAN 6. ALLSYSTEM COMPONENTS TO BE INSTALLED IN ACCORDANCE GROSSMAN WITH SEC TITLE V AND LOCAL BOARD OF HEALTH REGULATIONS. No. 127M 7. NO CHANGES TO LOCATION/ELEVATION OF SYSTEM COMPONENTS CIVIL WITHOUT WRITTEN APPROVAL OF ENGINEER AND BOARD OF HEALTH. /s I 8. NOTIFY ENGINEER 24 HRS. IN ADVANCE FOR AS -BUILT INSPECTION. NAI s REVISION DATE BY fcjmfl A I C'RosswaN SHEET NO. No• 12775 Todd Prada DATE 2 OF 2 Az #33 Cottage Drive, W. Yarmouth 03/23/07 PLAN NH-997-2O. L L I