HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
1 SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Zd Lot // Zone of Contribution: In Out Acreage . J E�
7
� / Commercial: Residential:
Street: 4 f 1 b a g,00 S
Village: Floor Plan: #Bedrooms: ill
Owner: ea N r.u' (>Q?l ejc
{� � Installer:
Address: Phone:
Phone:
Builder: Engineer: fc.i A,.e u 7 LN V,,v vw,
Address: Phone:
Phone:
N/A YES NO
1.Required#of copies received a/
2. Date of soils exam and percolation test not older than 2 years .' [
3.4-5 ft of naturally occurring pervious material,above water table /
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: /
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
L_ �
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ei
11.Tank/leaching minimum 10 ft from property line Var.: v
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.!
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable Vy
_17. System meets slope requirements-min. 1/8", %"preferred /
18. System meets breakout requirements PVC liner: Wall:19. Specified tee sizes are proper, gas baffle on outlet tee /
20. Sewage is under 10,000 gpd for parcel f
21.No garbage disposal /
22. System adequately sized for its intended use V
23.Minimum 6"stone or compacted below tank and dbox V
24. Manhole covers within 6"of grade, pump chamber cover to grade /
25. Inspection port on plastic chambers/leach field r
26. Electrical permit for pump chamber/Separate meter for duplexes --
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking /,
30. Buoyancy calculations for tank/pump chamber 7
31. Engineer to inspect and certify soils: wall: commercial:
17/
32. Engineer/Registered Sanitarian an. and Surveyor stamps/signatur- ?on i4 p V
33.H-20 loading is subject to vehicular tra ,a es .wa er
34.Title V Application and permit fee,installer signature ,_. /
35.Foundation footing min.2 feet above adjusted ground water for new house /
36.Deed Restriction required max. #bedrooms: max. flow: gpd 7
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 6 o.in
-