Loading...
HomeMy WebLinkAboutEngineer PlanNOTES ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE T PROVIDE -MIN. 20" DIAM. WATERTIGHT LOCATION. 1. DATUM IS NAVD 88 ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE TOP FOUND. EL 19.5' FILTER FABRIC OVER STONE 2. MUNICIPAL WATER IS EXISTING MINIMUM .75' OF COVER OVER PRECAST' 29� SLOPE REQUIRED OVER SYSTEM 18.5' 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. NOTE: 2" MIN. WALL PRECAST H-�a THICKNESS REQUIRED BLOCKS OR 4. DESIGN LOADING FOR ALL PROPOSED PRECAST RISERS (1YP.) UNITS TO BE AASHO H-10 2 4" SCH40 PVC PRECAST RISERS .. MORTAR ALL H-10 *; 6' MIN. SUMP PI ES LEVEL 1 ST 2' , COMPONENTS 12" MIN. INT. DIM.ENDS (TYP.) 7' q• 5. PIPE JOINTS TO BE MADE WATERTIGHT. �. *17.17' " 1500 GAL H-10 " SIDES 16.0 10 14 i' °°o"°o °" °°° °°° °°° 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE ➢_�,a.�,e°�o TEE SEPTIC TANK TEE , o o a o. o. o °°o °°° 15.75 5.5 _ o 0 0 ®®®Q® ® ®® ®�®� ooa00000 WITH 310 CMR 15.000 (TITLE 5.) �. No. 000000o0o W TERTEST D'BOX ;00000000 ®®®® ® ®® ® ;ooQ000000 0 0 0 0 oon0000n®®® ®® ®®0000007. THIS PLAN IS FOR PROPOSED WORK ONLY AND GAS BAFFLE r000 0,0_ F R LEVELNESS c�i o0000000 ®®® ��® 000000., , NOT TO BE USED FOR LOT LINE STAKING OR ANY 4' LIR. LEVEL (ACME OR EQUAL) 15.44' 1 .27' >�o�o�000 00000a�Q 13.17 OTHER PURPOSE. oil, ':,.,_,...._•.:..:.,... ;. ..�.. �:.• •..:.-.: L 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40- "°°'O°O°O°O°O°O°°°O°°°00000°O°OOD°°°O°°°O°O°O°O 4 PVC. o°000°0c0�o„o,n,o°o°0°0000ohoMoo0„00000°0. „ H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4-1-1/2" DOUBLE WASHED STONE 4' MIN. REQUIRED ALL AROUND PRECAST STRUCTURES (3) UNITS 9. COMPONENTS NOT TO BE BACKFILLED OR 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE 33.5' X 12.83' CONCEALED WITHOUT INSPECTION BY BOARD OF COMPACTION. (15.221 (2]) r- HEALTH AND PERMISSION OBTAINED FROM BOARD 19 OF HEALTH. LO 10. CONTRACTOR SHALL BE RESPONSIBLE FOR (�•5 SLOPE) (1 � SLOPE) 7.5' BOTTOM TH-1 CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP (1 X SLOPE) NO GROUNDWATER FOUND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. „ , SCALE 1 =2000 t FOUNDATION 15' SEPTIC TANK 6' D' BOX 12' LEACHING FACILITY 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 50 PARCEL 48 BE REMOVED BENEATH AND 5' AROUND THE *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X UTILITIES AND ALL BUILDING SEWER OUTLETS PRIOR TO NSTA I 4ND ELEVATIONS 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS - LLING ANY PORTION OF SEPTI SYSTEM AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001CO587J LEGEND SAND. DATED 7/16/2014 99 - EXISTING CONTOUR OF THE ENGINEER PERFORM INSPECTIONS FINAL INSTALLATION. MINIMUM OF24 HOURS X 99.1 Exf ST NOTICE REQUIRED. . SPOT ELr-V. PROPOSED CONTOUR l98.4J PROPOSED SPOT EL. TH1 0 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR W DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: JAY GARDINER DATE: 6/22/2022 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 18.5' IN PER 132" 1 7.5' .DEG NO GROUNDWATER ENCOUNTERED DCE #22- > 53 -■) v SATU N LANE �p D G SYSTEM DESIGN: - G G G ------ 10 .39 GARBAGE DISPOSER IS NOT ALLOWED p E - - - DESIGN FLOW: 4 BEDROOMS CAD 110 GPD = 440 GPD _ LOT 13 DRIV AY _i USE A 440 GPD DESIGN FLOW 12,132t S.F. p D BEDROOM LIVINGROOM SEPTIC TANK: 440 GPD (2) = 880 19 USE A 1500 GAL. SEPTIC TANK a!GARAGE LEACHING: 1g BEDROOM BATH KITCHEN PORCH SIDES: 2 (33.5 + 12.8) 2 (.74) = 137 GPD EXI TING DWELLING / BOTTOM 33.5 x 12.8 (.74) = 317 GPD TOF = 19.5' LF TOTAL: 614 S.F. 454 GPD EXISTING l ST FLOOR PLAN NOT TO SCIdE USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND '---19 o a? r BEDROOM BEDROOM rr BATH NJ q [16.5J r 0 -o r O 'v� � �ti o EXISTING ) ' J.O --t�_ �� 2ND FLOOR PLAN - - MA 'LP �,,--,t NOT 70 sc4cE APPROVED DATE BOARD 0 HEALTH TH 1 <<LP � TITLE 5 S TE PLAN Q OF BENCHMARK: BULKHEAD =19.0' NAVD88 #7 SATURN: LANE rn ��' SOUTH YARMOUTH, MA PREPARED FOR , OF s ���jHOF4fjo JOAO PEREIRA qC� �� DANIELA cy la�?�;Ir=L ��� R Al 0AL.A 'f o OCIVIL JALA DATE: JULY 18, 2022 r. Nci. 4G983n �. n No. 46502 off 508-362-4541 �q°�Fess 0�pcN�� E�fax 508-362-9880 sUR I I downcape.com p � down alt engine�rin,�, iec. Scale: 1,,= 20' ~may civil engineers �--. /crud surveyors 0 10 20 30 40 50 FEET HEAD,` DEPT. DATE DANIEL A. OJALA, P.E., P.L.S. 939 Main Street i Rte 6A > YARMOUTHPORT MA 02675 22-153 PEREIRA.DWG