HomeMy WebLinkAboutEngineer PlanTBM EL = 49.2
Top of Bulkheo
Mop 60
Parcel 119 1,L0 �� SA
Line
i
(49.3)
1.) Assessor's Map 60 Parcel 120
2.) Bk 1865Pg. 344
3.) Plan Book 84 Page 149 Lot A
ao 5.) This property is not in the Aquifer
Q, Protection District
S $ spa J, 5.) This property is in Flood Zone X
12. Firm map 250001CO587J Dated: 7/16/14
x.x DB.
i,� .
xx
Ca 6� \9 s Line x x .. x TIPeSc
Eliminate x x 49 q / Mop 60
kox, � 9os Outletti Parcel 123
i S (49 5) r' � 1
\ ?� Lot
�N, 11.350±
�o \ aQ
�O, �O \
0
LOCATION OF UTILITIES IS APPROXIMATE AND ALL
UNDERGROUND AND OVERHEAD UTILITIES MUST BE
DETERMINED IN THE FIELD PRIOR TO COMMENCEMENT
OF ANY WORK, THIS INCLUDES, BUT NOT LIMITED TO,
REQUESTS TO DIGSAFE, ANY PRIVATE UTILITY COMPANIES
AND THE LOCAL WATER DEPARTMENT.
as
/ j\
Reroute 48
ofe`—< Plumbing, / Note �i9 �ST
ter \ Existing �i tiofl �} Elev = 48,0 j
(to remain)
1 House #62
3 Bedroom \
TOF EL = 50.0t
Ft
South Yarmouth, MA
SITE LOCUS
NOT TO SCALE
Maximum Feasible Compliance
Variances: 310 CMR 15,221 (7) General Construction
Requirements for All System Components:
1.) Variance to the 20' setback between the edge of the SAS
and the Foundation. An 10.0' setback is provided.
An 10' Variance is requested. 310 CMR 15.405(1)(a)
(20.5) j Permit/:�I�cl iU� REPAIR OF 5E YSTEIY 60
Y, oitc W Slate and 1,o sep 'c varian�Ies• el 122
o: >.colt review a approval is quired W
i 9ny /, ;otlth ' strenovationstalter lions to
dill • ami/or structuresidw0 ing. ��F0s
1 ar month health Department
EP9r
/ \/ 5,;STH�N s�
(48.9) i 12a �jl IlV Y ' �RQORE
u
IO
Dates�R
Map 60
\ / Parcel 121 6 "�
GRARHIC SCALE
10 20 40
(IN FEET)
1 inch = 20 ft.
3 FF 7 7-M v D
NOV -1 b 2022
HEALTH DmPT
80
Proposed
62 Pond Street
Prepared for:
Wesley Griifin
62 Pond Steet
South Yarmouth, MA
€2
Septic Plan
South Yarmouth, MA
Prepared by:
All Cape Septic LLC
618 Route 28
West Yarmouth, MA 02673
(508) 771-4200
alicapeseptic@gmoil.com
Date: i v/25/22 Sheet 1 of 2 By: MA Check: SM Project No. AC-518
Exit House RAISE MIN. 20" DIAMETER COVER RAISE. MIN. 20" DIAMETER COVER
CONSTRUCTION NOTES Top Fnd. TO WITHIN 6" OF FINISH GRADE TO WITHIN 6" OF FINISH GRADE
FI -tin n4-
1.) ALL WORK SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 (310 CMF 15.000):
STANDARD REQUIREMENTS FOR THE SITING; CONSTRUCTION, INSPECTION, UPGRADE, AND
EXPANSION OF ON -SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS AND FOR THE NSPORT
AND DISPOSAL OF SEPTAGE, AND THE LOCAL BOARD OF HEALTH REGULATIONS.
2.), ANY SEPTIC SYSTEM COMPONENT INSTALLED IN A LOCATION WHERE THERE IS POTENTIAL FOR
VEHICLES OR HEAVY EQUIPMENT TO PASS OVER IT SHALL BE DESIGNED TO WITHSTAND AN H-20
LOADING, IF UNDER AN IMPERVIOUS SURFACE, SYSTEM SHALL BE VENTED TO THE ATM SPHERE.
3.) TO MINIMIZE UNEVEN SETTLING, SEPTIC TANKS AND D-BOX SHALL BE INSTALLED a A STABLE
MECHANICALLY -COMPACTED BASE ON SIX INCHES OF CRUSHED STONE.
4.) COVERS OVER THE INLET AND OUTLET TEES OF THE SEPTIC TANK, THE DISTRIBUTIC14 BOX, AND
THE SOIL ABSORPTION SYSTEM SHALL BE RAISED TO WITHIN 6" OF FINAL GRADE. LEACHING
FIELDS, TRENCHES, AND OTHER SOIL ABSORPTION SYSTEMS WITHOUT ACCESS MANHOLES SHALL
HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4" PVC PIPE PLACED
VERTICALLY TO THE BOTTOM OF THE SOIL ABSORPTION SYSTEM WITH A CAP, TIED WITH MAGNETIC
MARKING TAPE, ACCESSIBLE TO WITHIN 3" OF FINAL GRADE.
5.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT, PIPE SHALL BE LAID ON A
MINIMUM CONTINUOUS GRADE OF NOT LESS THAN 2% FROM THE BUILDING TO THE SEPTIC TANK,
AND NOT LESS THAN 1% OTHERWISE.
6.) DISTRIBUTION LINES FOR THE SOIL ABSORPTION SYSTEM SHALL BE 4" DIAMETER SC14EDULE 40
PVC (OR EQUIVALENT) LAID AT 0.005 FT/FT. UNLESS OTHERWISE NOTED. LINES SHALL 3E CAPPED
AT END OR AS NOTED.
7.) LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRST TWO (2) FEET 8£ ORE
PITCHING TO THE SOIL ABSORPTION SYSTEM. DISTRIBUTION BOX SHALL BE WATER TESTED TO
ASSURE EVEN DISTRIBUTION.
8.) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES
IN ORDER TO PROVIDE A WATERTIGHT SEAL,
9.) HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE
DISPOSAL FIELD DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM.
10.) IN ACCORDANCE WITH 310 CMR 15.221, ALL SYSTEM COMPONENTS SHALL BE MARK D WITH
MAGNETIC MARKING TAPE.
IL) THERE ARE NO KNOWN WELLS OR WETLANDS WITHIN 150' OF THE PROPOSED SOIL 0SORPTION SYSTEM,
12.) FROM THE DATE OF THE INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF
THE CERTIFICATE OF COMPLIANCE, THE PERIMETER SHALL BE STAKED AND FLAGGED TO PREVENT
USE OF THE AREA THAT MAY CAUSE DAMAGE TO THE SYSTEM.
13.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS
CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES SHALL BE APPROVED IN WRITING E Y THE ENGINEER,
14.) THE BOARD OF HEALTH REOUIRES INSPECTION OF ALL CONSTRUCTION BY AN AGENr OF THE
BOARD OF HEALTH AND THE DESIGNER. THE DESIGNER SHALL CERTIFY IN WRITING THAT THE
SEWAGE DISPOSAL SYSTEM WAS INSTALLED IN ACCORDANCE WITH THE TERMS OF THE RERMIT
AND THE APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS REQUESTED.
15,) LOCATION OF UTILITIES IS APPROXIMATE AND CONTRACTOR SHALL BE RESPONSIBLE FOR
DETERMINING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO
COMMENCEMENT OF ANY WORK, THIS INCLUDES, BUT IS NOT LIMITED TO, REQUESTS TO DIGSAFE,
ANY PRIVATE UTILITY COMPANIES, AND THE LOCAL WATER DEPARTMENT.
16.) CONTRACTOR SHALL VERIFY THAT ALL WASTELINES ARE CONNECTED BY WATER m -ONG
WITHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS.
17,) CONTRACTOR SHALL VERIFY EXISTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY
SEPTIC SYSTEM COMPONENTS.
18.) TEST HOLES COMPLETED PER STATE ENVIRONMENTAL CODE, TITLE 5. SOILS CAN BE
VARIABLE AND TEST HOLE DATA IS NO GUARANTEE OF SOIL CONDITIONS IN OTHER AREAS. IF
SOILS DIFFER FROM THOSE SHOWN IN THE SOILS LOGS, DESIGN ENGINEER IS TO INSPECT THE
SOILS PRIOR TO PROCEEDING WITH INSTALLATION OF ANY SEPTIC COMPONENTS.
19.) EXISTING SEPTIC COMPONENTS TO BE LOCATED, PUMPED DRY, FILLED WITH CLEAN 3AND AND
ABANDONED IN PLACE OR REMOVED AS REQUIRED. AREA TO BE COMPACTED TO MINIMIZE SETTLING.
49.0+
I e 5 e 47.6
. _ 30't
" A,U 46,25
o
00
tl'
LE GAS BAFF6" Cru
Stone
......... /
1,500 GALLON
SEPTIC TANK
^r r- e, -r- I I n 1 r- 1 /11% n t^
Test Hole 1 (EL-49.Ot)
1 C J I I I V L L_ L U L7 J
Depth
Elev.
Layer
Soil Class
Soil Color
Other
0-11"
48.1
A
Loamy Sand
1OYR3/2
11"_22"
47.2
B
Loamy Sand
10YR3/4
2.2"-144"
37.0
C
Med Sand
21OYr6/4
DATE OF TESTING: 08/19/22
SOIL EVALUATOR: MARK POLSELLI
WITNESS: JAY GARDINER YARMOUTH HEALTH AGENT
PERCOLATION RATE HOLE #1: LESS THAN G 2 MIN/INCH (0 51")
NO GROUNDWATER ENCOUNTERED
NO MOTTLING ENCOUNTERED
Bed
Be Bath
1 Kit
81 it/ Liv
1 -- 22't --�
0
M
GEOTEXTILE
FABRIC
r •Liner
t
Mil
46.0
I r r r
45.4
z ti !1-1/2" STONE
r TWO !! GALLON
43.0 CONCRETE LEACH CHAMBERS WITH 4' OF
STONE ON ENDS AND 4' ON SIDES 4t.0
6 LEACH CHAMBERS 6.0'
(END VIEW)
FLOW PROFILE
NOT TO SCALE EL=37.0 Bottom Test Hole
SYSTEM DESIGN CALCULATIONS
SEWAGE DESIGN FLOW: EXISTING THREE BEDROOM DWELLING 0 110 GPD/BEDROOM = 330 GPD
(MINIMUM DESIGN REQUIRED 330 GPD)
SEWAGE DESIGN FLOW PROVIDED: TWO (2) 500 GALLON CHAMBERS
WITH 4' STONE ON THE ENDS AND 4' STONE ON THE SIDES
Vt = [(25.0 x 12.83) + 2(25.0 + 12:83) (2) x .74 = 332 GPD PROVIDED
332 GPD PROVIDED > 330 GPD REOUIRED
SEPTIC TANK CAPACITY REQUIRED: 330 GPD X 200 = 660 (MINIMUM)
SEPTIC TANK CAPACITY PROVIDED: 1,500 GALLON SEPTIC TANK (PROPOSED)
A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN FLOW
Proposed
62 Pond Street
Septic Plan
South Yarmouth, MA
Prepared for:
Wesley Griifin
62 Pond Steet
South Yormouth, MA 02664
Prepared by:
All Cape Septic and Survey
618 Route 28
West Yarmouth, MA 02673
(508) 771- 4200
alicapeseptic@gmaii.com
Date: 10/25/22 Sheet 2 of 2
Project No. AC-518-2