HomeMy WebLinkAbout115 River St plans 2G A U G H RAN 115 RIVER STREET E S I D E N C E SOUTH YARMOUTH MA. PROPOSED FRONT ELEVATION (east) DESIGNER: NORTHSIDE DESIGN STRUCTURAL ENGINEER Taylor Design LLC ASSOCIATES CIVIL ENGINEER 141 main street yarmouthport MA 02675 Phone: 508.362.2210 fax: 508.362.5269 northside 1 @comcast.net www.northsidedesign.com BUILDER/CONTRACTOR LIST OF DRAWINGS I PAGE # I SHEET # I DESCRIPTION I I 1 C COVER SHEET: PROJECT INFO. & DRAWINGS INDEX I 2 A.0 FOUNDATION PLAN 3 A.1 1ST FLOOR PLAN 4 A.2 2ND FLOOR PLAN 5 A.3 ELEVATIONS 6 A.4 ELEVATIONS 7 A.5 BUILDING SECTIONS 8 A.6 BUILDING SECTIONS 9 A.7 DETAILS 10 A.8 FRAMING TIE -DOWN DETAILS 11 S. 1 111 FLOOR FRAMING PLAN 12 S.2 2ND FLOOR FRAMING PLAN 13 S,3 ROOF & ROOF FRAMING PLANS TYPICAL NOTES I, CONTRACTOR SHALL 51TE INSPECT ALL EX15TING V5. PROPOSED CONDITIONS PRIOR TO AND DURING CON .CT ON AND NOTIFY DESIGNER OF ANY DESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. 2. CONTRACTOR SHALL NOTIFY DESIGNER, IF AT ANY TIME THRO/GFgUT CONSTRUCTION ANY EXISTING CONDITIONS ARE FOUND THAT MAY PREVENT THE SUCCESSFUL COMPLETION OF ANY PORTION OF PROPOSED BUILDING, CONTRACTOR SHALL NOTIFY DESIGNER OF SUCH PRIOR TO MAKING ANY ADJUSTMENTS OR ALTERATIONS TO PROPOSED BUILDING AS PRESENTED IN FINAL CONSTRUCTION DOCUMENTS. 3. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. ANY MISSING, INCORRECT OR QUESTIONABLE DIMENSIONS NOT BROUGHT TO THE ATTENTION OF THE DESIGNER BECOME THE RESPONSIBILITY OF THE CONTRACTOR, 4. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN TEMPORARY WALL5/SHORING ETC. TO MAINTAIN/PROTECT EXISTING HOUSE AND STRUCTURAL INTEGRITY OF EXISTING HOUSE. 5. CONTRACTOR SHALL SCHEDULE AND PROTECT FROM WEATHER ALL EXISTING HOUSE COMPONENTS AND INTERIORS DURING CONSTRUCTION AND CONSTRUCT TEMPORARY STRUCTURES/ENCLOSURES AS MAY BE NECESSARY TO ENSURE 5UC14 PROTECTION. 6. STRUCTURAL ENGINEER/DESIGNER TO PERFORM FRAMING INSPECTION WHEN FRAMING 15 COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR WALL PLASTER BOARD/FINISH. FOUNDATION NOTES I. NEW FOUNDATION WALLS TO BE 10" POURED CONCRETE W-3000 Psi, W/ 2@A5BAR5 TOP t BOTTOM. FOUNDATION WALL TO BE ON 10x20' STRIP FOOTING. PROVIDE 3@N5 HORIZ, BARS CONTINUOUS IN STRIP FOOTING W/ KEYWAY. PROVIDE 75 VERTICAL DOWELS P 24" O.C. EXTENDED V -6 - MIN. ABOVE TOP OF FOOTING. PROVIDE W ANCHOR BOLTS @ 52' O.C. MAX. MIN. 7' EMBEDMENT W/ 9'xVA" PLATE WASHER. 2. INTENT OF DE51GN 15 TO ALIGN NEW FIRST FLOOR SPACES WITH EXISTING FIRST FLOOR. CONTRACTOR SHALL ADJUST TOP OF FOUNDATION WALL AS NECESSARY TO ENSURE DESIGN INTENT. 5. CONTRACTOR SHALL ENSURE THAT ALL FOUNDATION WALLS MAINTAIN 4-0" MINIMUM COVER. 4. CONCRETE SLAB TO BE 4' POURED CONCRETE ON COMPACTED FILL. PROVIDE CONTRACTION JOINTS I" DEEP AT COLUMN LINES. CUT W/ 'EARLY ENTRY" SAW. 5. CONTRACTOR TO PROVIDE CRAWL SPACE VENTILATION AS REQUIRED BY CODE (WINDOWS OR MECHANICAL) 6. ALL STRUCTURAL STEEL COLUMNS TO BE %' CONCRETE FILLED LALLY COLUMNS TO EXTEND TO FOOTING BELOW. PROVIDE 6'xb'.%' CAP PLATE 4 7'x12'x%' BASE PLATE W/ 21 DIA. BOLTS. WELD ALL CONNECTIONS. FOOTINGS TO BE 56 x36"xl2' SQUARE CONCRETE W/ 3@ its BARS EACH WAY. 7. PROVIDE WEB STIFFENING PLATES AT BEARING POINTS OF STEEL BEAMS (TYP,). 5. SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STRUCTURAL COLUMNS. 9. DOUBLE FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS 10, GARAGE AND OTHER FILLED FOUNDATIONS, IO" POURED CONCRETE WALL W/ 2@ b5 TOP AND BOTTOM BARS, FORM FOUNDATION ON 10'x20' STRIP FOOTING, PROVIDE Z! A5 CONTINUOUS HORIZONTAL BARS AND KEYWAY IN STRIP FOOTING. LAP TOP BARS TO MAIN WALL BARS, PROVIDE TRANSITION REINFORCING W/ its BARS SPACED @ 12' O.C. VERTICALLY. PROVIDE %' x 12" ANCHOR BOLTS @ 32" O.C. MAX, MIN. EMBEDMENT W/ 5'x5'xiq" PLATE WASHER, I OTHER NOTES I I SAFETY STANDARDS - FALL PREVENTION I CONTRACTOR TO PROVIDE FALL PREVENTION ON ALL WINDOWS WITH SILLS MORE THEN 72" ABOVE FINISH GRADE PER CODE, ALL WINDOWS SHALL HAVE FALL PREVENTION DEVICES AND SHALL COMPLY WITH THE REQUIREMENTS OF A5TM F2" WINDOW OPENING DEVICES SHALL BE SELF ACTING AND SHALL BE POSITIONED TO PROHIBIT THE FREE PASSAGE OF A 4' DIAMETER RIGID SPHERE THROUGH THE WINDOW OPENING WHEN THE WINDOW OPENING LIMITING DEVICE 15 INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. REVISIONS NO. REVISION DATE H ZU) W w p Z F LU 1 Z p w 0 w 0 0 0 — H= 10 K W 0 m O � X00 Z '0 , F. , w w}V O K F O Z 2 ~ w=�¢i z w °W w wa�z I_ =w�<'o3wpa (� T QO �ZU } W Q Q O; Z O p � p 000 owzMww wz wwzof w- -- H 2 U00===Xww Z O H O w w 0 TITLE : COVER SHEET LSCALE:.S. 77 PROJECT#: SHEET 20-15 C DATE: OF 9/3/21 13