Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST / Location: A.M. 22 Lot 3.� Zone of.Contribution: In Out V Acreage /5 t t 2 t' Commercial: Residential: Street: /S W& I ,Q_,�-74� Village: tvCS7 Floor Plan: ✓ #Bedrooms: tt Owner: 1-4A-7-7,# S L i /C !-4 Installer: - Asstss , Address: Phone: Phone: Builder: Engineer: 6-de-) '-r-L--cm Address: Phone: Phone: N/A YES i NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years ./`- 3.4-5 ft of naturally occurring pervious material,above water table / -- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: / 5. Water line 10 ft from septic components Var.: . ✓ 6.Benchmark indicated and shown-NGVD if near wetlands - ✓ 7. Septic tank minimum 10 ft from foundation,deck Var.: 3' 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: S ' Tu 6u, 9.Leaching minimum 100 ft from wetlands Var.: ✓ 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: / 11.Tank/leaching minimum 10 ft from property line Var.: / 12. System meets all other setback requirements Var.: I 7 13.Uses adjustment or maximum high groundwater Var.: -T,ak-1.- 14.Leaching set 4 5 above adj.water or bottom of test hole Va .. V 15. Syste no n top or subsoil(A,B horizons)or 5' removal i' 16.Proposed contours are suitable V 17. System meets slope requirements-min. 1/8", '/4"preferred / 18. System meets breakout requirements PVC liner: Wall: r/ 19. Specified tee sizes are proper, gas baffle on outlet tee V 20. Sewage is under 10,000 gpd for parcel ,/ 21.No garbage disposal V 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox ✓ 24. Manhole covers within 6"of grade, pump chamber cover to grade ✓ 25. Inspection port on plastic chambers/leach field V 26. Electrical permit for pump chamber/Separate meter for duplexes / 27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size / 28. Septic tank/pump chamber to be factory waterproofed / 29. Vent provided if leaching below 3 feet,under driveway/parking / 30. Buoyancy calculations for tank/pump chamber / 31. Engineer to inspect and certify soils: wall: commercial: I / 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature / 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee,installer signature ✓ 35.Foundation footing min.2 feet above adjusted ground water for new house 36.De d;Restriction required max. #bedrooms: max. flow: ip d I ✓ 37. Check area lots for groundwater/Label groundwater' Assessor's Map Plan reviewed by: _e_5 2.4317t.- _ 6 03 0? Th