Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-21-007109
a Commonwealth of Official Use Only E Permit No. BLDE-21-007109 ,�,� Massachusetts BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:6/7/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perto�e electrical work describe Location(Street&Number) 2 SATURN LN ,0 S v 1 PiK Owner or Tenant NOZZOLILLO MICHAEL B Telephone No. Owner's Address NOZZOLILLO KATHLEEN B, 17 OXFORD TERRACE,WESTWOOD, MA 02090 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters _ New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(36 Panels 11.7 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Lloyd R Smith Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 C..ommonweatth o/faadachujett6 Official Use Only 9 l •-.411--,A, `� // I ('Ell1 c� �/ Permit No. C 2)epartment o/.}ire_ervices -(f ,4 BOARD OF FIRE PREVENTION REGULATIONS [Rev7 Oc.1up/07]y and Fee Checked (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRIC L WORK All work to be performed in accordance with the Massachusetts Electrical Code(M C).527 CMR I . (PLEASE PRINT IN INK OR TYPALL I F'ORVAr Date: (`(� 3 City or Town of: V U R J I 1 To the Inspector of Wires: By this application the undersigned gi es no=ice of is or her intention to perform m the electrical work described below. Location(Street&Number) D Owner or Tenant & it j I Gl " Telephone No. '1Z1( z.ow Owner's Address 6kL D ai,• r Is this permit in conjunctiok with a building permit? Yes ❑ No ❑ (Check Appropriate Box) Purpose of BuildinIg g 'J I (/L Utility Authorization No. Existing Service ICS Amps 12 /94)V Overhead 2( Undgrd❑ No.of Meters New Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Oho-avoIbac sc* r s s m�S) �� K � o :`completion of the following table may be waived by the Inspector of Wires. No. ranoKVA Total No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- Li 'Io.of Emergency Lighting grnd. grnd. BatterUnits No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: ,Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local El Municipal ❑ Other Connection No.of Dryers Heating Appliances KWSecurity Systems:* No.of Devices or Equivalent No.of Water No.of No.of KW Heaters Signs Ballasts No.of Devices Wiring: or Equivalent No. Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: � j1r� Attach additional detail if desired,or as required by the Inspector of Wires. 2� Estimated Value of lec ical Work: 'I L (When required by municipal policy.) Work to Start: I . Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE CO E GE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such cove ge is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE LTJ' BOND ❑ OTHER ❑ (Specify:) I certify,under thi,pains and penalties of per'.ry,that the information on this ap 'cation is true and complete. FIRM NAME: 1/ IV 1 ,g)Ia V I LIC. NO.: Licensee: ,, / AI Signature �1 lir..? Tri �_..� 1�.�� LIC.NO.: � �a/Oo ' 3 (If applicable.enter "exempt"in the license number�I{'ne.) Bus.Tel. No.: L II • 4. Address: KS- M4)Its S i tr\ a LuA1 I1)MM �'r,�( ) Alt.Tel.No.:3=- `—t&s *Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic. No. l OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. [am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: $ GOVERNING CODES - ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: 2015 INTERNATIONAL RESIDENTIAL CODE 2020 NATIONAL ELECTRICAL CODE 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION *ECTOR n a i n e e R e SHEET INDEX 651 W. PARK ar•.!GI PHONE PV 0.0-COVER SHEET Pa.Pea. .020 ....yammer. nt PV 1.0-SITE PLAN 3F1`1 tk, PV 2.0-ELEVATION(S) ct WELLS L. s S 1.0-MOUNT DETAILS '/ ES , S 1.1-BATTERY RACKING DETAIL No.54240 E 1.0-ELECTRICAL DIAGRAM ,\•+., �,f+''' <" . E 2.0-ELECTRICAL NOTES i #''':�.- E 3.0-WARNING LABELS 05/25/2021 E 4.0-WARNING LABEL LOCATIONS VSE Project Number:U2145.6888.211 E 5.0-BONDING DETAILS Vector Structural Engineering has reviewed the existing structure with loading from the solar array end lag screw connections to the ousting framing.The design of the racking system,racking connections,and all other structural d by others.Mechanical,arNitecturel,and ell other nonstructural aspects of the desgn are by otilers. Electrical is by others,unless clamped by Dean Lawmen. GENERAL ELECTRICAL NOTES GENERAL STRUCTURAL NOTES 1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED SYSTEMS- ROCK-IT RAIL-LESS SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SPACED AS SHOWN IN THE DETAILS-AND MUST BE STAGGERED TO ADJACENT SURFACE. FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. • 2.ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE 2.UNLESS NOTED OTHERWISE SEES 1.0-MOUNTING ANCHORS SHALL BE 5/16"LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2-112"MIN PENETRATION INTO ROOF FRAMING. 3.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT COD 3.THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM 4.RAPID SHUTDOWN COMMENCES UPON MANIPULATION OF LOCAL OR REMOTE 4.ROOF LIVE LOAD=20 psf TYPICAL-0 psf UNDER NEW PV SYSTEM. INVERTER DISCONNECT SWITCH. 5.GROUND SNOW LOAD=30 psf 5.SEE•E 1.0 AND CE 2.0 FOR DIAGRAMS-CALCULATIONS-SCHEDULE AND 6.WIND SPEED=140 mph 2 Sarum Lr.. SPECIFICATIONS. 7.EXPOSURE CATEGORY=B Sown'arrnoult' MA 6.480.7(A):BATTERY DISCONNECT MEANS CONTAINED ON BATTERY UNIT 7.480.10(A):VENTILATION.BATTERY TECHNOLOGY DOES NOT EMIT GASES. VIVIt1t• a ar ADDITIONAL MECHANICAL VENTILATION NOT REQUIRED SUIIIUn t,;.if-',.- , 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 MA LIC,170848115688A PHOTOVOLTAIC SYSTEM SPECIFICATIONS SYSTEM SIZE-11.7KW DC 17.6KW AC KRUTIAK RESIDENCE LN C MODULE TYPE&AMOUNT-(36) JA SOLAR JAM60S17-325/MR WITH SOLAREDGE P370 OPTIMIZERS SOUTH YARMOUTHH,,MA 026644335 MODULE DIMENSIONS:(LIW/H)66.5"/39.2"/1.4" UTILITY ACCOUNT:14854970036 n METER:2306538 INVERTER:(1)SOLAREDGE TECHNOLOGIES SE7600H-USS PV BATTERY STORAGE-(1)LG CHEM RESU1OH WITH 5KW DC I 9.8KWH PV STORAGE CAPACITY Sit S4553059Z. INTERCONNECTION METHOD(HYBRID): LOAD TAP ROC:MA-03 PV 0.0-! DRAWN BY:DIN DATE:05/22/2021 -- REVISION:0 u PV STRINGS: ROOF SECTIONS: SYSTEM LEGEND - PV SYSTEM SIZE: V//PV STRING 1=18 MODULES ROOF PLANE 1 SLOPE=25° (N)11.7 KW DC 17.6 KW AC ROOF PLANE 1 AZIMUTH=179° BATTERY SYSTEM SIZE: M PV STRING 2=18 MODULES ROOF 1 MAT=COMPOSITION SHINGLE 5 KW DCI 9'8 MI ROOF PLANE 2 SLOPE=25° M POINT OF INTERCONNECTION N ROOF PLANE 2 AZIMUTH=359° EXISTING INTERIOR MSP TIED TO ROOF 2 MAT=COMPOSITION SHINGLE UTILITY METER 2308538. B (N)1 LG RESU1OH PV BATTERY STORAGE UNIT(S). INTERIOR BATTERY ® (N)SUB PANEL WITH EXISTING HOME INSIDE BASEMENT LOADS ® NAEWUTOMATIC BACKUP USER NTRANSFERTERFACE SWITCH O <(N)PV SYSTEM AC DISCONNECT. NO \ 1 PV TR SE7 PV STRING INVERTER: SE7 p (9) 36 JA SOLAR JAM60S17-3251MR MODULES WITH P370 OPTIMIZERS MOUNTED ON THE BACK OF EACH \N ..-- MODULE. BUI O '-t(N)JUNCTION BOX. (MOUNTED WITH SOLADECK) EXISTINGY DETACHED UTILITMEe TER(2308538) VECTnOR e n a t n e e M Q rtn..aa,urn"EN F, SOw i ..x«,n.a o" ACHOL S L. IBI C 8 STRUCTURAL S H O ClNo.54240 v' ' \1\N/ / / 05/25/2021 VSE Project Number:U2145.6888.21I O Vogear Structural Engeeerag has mewl Me emoting / strucbra We leading from IM solar arra andO Yg screw nngsone to the existing framing.The design of tM1a / racking system.tees. connections.and all alar / structural is by others.uessnmal,ad by DeaaMa1n other noneWClaral aspects of the design are by others. Electrical\\\\ //////7 /. is by otM1ens,unless stamped by Dean Levpse vivint.Solar N SUI1IUr1 r, : e, 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 MA LIC:170848115668A KRUT2SARRNLNIN SOUTH YARMOUTH,MA 02664-4335 e UTILITY ACCOUNT:14854970036 41. METER 2308538 "A SITE PLAN 2 SATURN LN SH S-6553059 PV 1.0,6__,,m SCALE:1/4"=1'-0" FRONT OF HOUSE. 03 DRAWN B DIN P1 REVISION:0 L LEGEND/NOTES . EXTERIOR INTERIOR FROM ROOFTOP FROM INVERTER NEW LO CHEM RESUIOH EXISTING EXTERIOR LG _I MAIN SERVICE PANEL TED TO unm METERQETACIEDT .2508538 NEW SOIAREOGE SOLAREDGE TECHNOLOGIES SE7600H-US BACKUP USER INTERFACE • • (BUB • • NEW ELECTRICAL GUTTER-_ ED TO BATTERY I I VIVint.Solar sunrun, 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 MA LIC:170848115688A KRUTIAK RESIDENCE 2 SATURN LN Lv SOUTH YARMOUTH,MA 02664.1335 N UTILITY ACCOUNT:14854970036 METER:2308538 ELEVATION(S) R"1 PV 2.Oa ROCC:MA-03 DRAWN BY:DIN SCALE:NOT TO SCALE DATE:052212021 REVISION,0 .0 I MOUNTING NOTES . VECTOR ROCK-IT COUPLING ■ n • I t7 ! ■ R • MID CLAMP err.WI PH 990.1775 ROCK-IT COUPLING © nw.>rn.ur...9.1020TNS ww.vrcronsr.row MID CLAMP ®i o? WELLS L. +G MOLMES ® STRUCTURAL H II■ \t No.54240 '� ROCK-1T 3A COUPLING ' I ROCK-IT SLIDE / MID CLAMP ` s'-••,.1.1.'' :% *a •l;/!!' ROCK-IT PEDESTAL ' / , /f���W'J�' METAL ROCK-R 4 5116'x18' •�• PUSHING COUPLING SHELF HEX FLANGE BOLT �- Ir 'Ir ,. 05/25/2021 300 SERIES SS ROCK-IT COUPLING SHELF _ ISOMETRIC VIEW �/% VSE Project Number:U2145.6888.2I I I l Iii Vector has COMP SHINGLES `t structure nstoboeatram theral solar.reviewed VINeearstinw SS LAG SCREW f i connections to the existing framing.This designof Me TORQUE=1302 FT-LBS. I.' racking system.racking connectlaw,and all War ` Q\\� structural a by others.Mechanical,arclvle ural and all SIDE VIEW 1 116'x1 IR' other OOI w Ent010 aspects a the benign are KY Wren. TIE PLATE HEX FIANCE BOLT Electrical W by others,unless stamped by Dean Leyasen. 8 ILSCO SGB-4 GROUNDING LUGS SIDE VIEW MO SERIES SS ® ®O 1 ROCK-IT 3.0 MOUNT DETAIL S 1 0 NOT TO SCALE S 1.0 NOT TO SCALE U.L.LISTING FOR ECOFASTEN.2763 2 ROCK-IT 3.0 COUPLING ASSEMBLY WEIGHT:2.3D. ST.0 NOT TO SCALE TOP VIEW MAX MOUNT SPACING LANDSCAPE MOUNT SPACING=64" CLAMP.ATTACHMENT,TYP LANDSCAPE CANTILEVER=21" • CLAMP.ATTACHMENT,TYP PORTRAIT MOUNT SPACING=48' • COUPLING'TYP PERMITTED COUPLING,TVP PORTRAIT CANTILEVER=16' CANTLEVER:SEE MOUNTING NOTES I I CLAMP SPACING SPACING:SEE MOUNTING NOTES COUPLING CLAMP FRAMING,TYP MODULE,TVP ROCK4T SLIDE MODULE METAL r� 1'1 MODULE,TYP FLASHING I I EPOMBONDED WASHER y II !y RAFTER FRAMING,TYP FORMS WATERTIGHT SEAL / I I LAAMISCAPE CLAMP SPACING i ■ 4 PV SYSTEM MOUNTING DETAIL 5 MODULES IN PORTRAIT/LANDSCAPE I I L=PORTRAIT s 1.0 NOT TO SCALE 8 1.0 NOT TO SCALE CLAMP SPACING COMP SHINGLES 2.11 MN 3'MIN AND 6'MAX BETWEEN TOP OF ROOF AND BOTTOM OF MOOULE MW 5•1S'RAM A ONE HOLE STEEL STRAP CONDUIT SS LAG SCREWS O FRAMINODULE,G TYP.EXISTING TORQUE=1322 FT-LBS. TOOROOF TY E,OE%ISTNL ®_ __ JJJ/- ROOFTYPE,PARALLEL + WITH PLANE OF ROOF CONDUIT MOUNT BRACKET _ vivinI.Solar 1800 ASHTON BLVD.LEHI,UT,84043 SECTION VIEW /''• 117 1.877.404A129 FLASHING OR TLE STRAP �� MA LIC:170848115688A 1- -_ �• "- '• �" KRUTIAK RESIDENCE 2SATURN 3 SECTION VIEW ---_—_-------------------- SOUTH YARMOUTH,MA 02664-4335 v S 1.0 NOT TO SCALE - PV ARRAY TYP.ELEVATION 7 CONDUIT MOUNTING DETAIL UTILITY ACCOUNT:14854970036 METER:2308538 n NOT TO SCALE S 1.0 NOT TO SCALE MOUNT DETAILS SOS-6553059 S 1.Oa ROC:MA-03 DRAWN BY:DIN A SCALE NOT TO SCALE DATE:092212021 REVISION:0 .amu NOTES ,_ 1Y2"EMBEDMENT(MIN) 24"MAX ANCHOR SPACING-- ADDITIONAL STUD, 2X4 STUDS(MIN) • WHERE OCCURS 1 f (ik X S PC II X X PLYWOODANALL FINISH I �' —MOUNTING RACK (WHERE PRESENT) Y"LAG SCREWS WITH WASHER FOR STABILITY SHALL BE INSTALLED IN FRAME MEMBERS.(4)IN TOP OF BRACKET,(4)IN BOTTOM. (4)ADDITIONAL SCREWS OR SHEETROCK ANCHORS. . (2)LOCATIONS TOP,(2)LOCATIONS BOTTOM. LG CHEM BATTERY MOUNTING RACK-\ 12"(I IN TO TOP OF WALL ® o 0 0 0 0 0 0 0 0 0 ® o 0 0 0 0 00 o 0 0 0 2-11" . WALL STUDY WALL STUD (9 0 0 0 0 0 0 to 0 0 0 0 0 o o o o o o o o ® 1—J 2'-4" 1'4'- 10"(MIN '4"-10"(MIN 24"( ) 29"MIN TO BOTTOM OF WALL v$VInt•Solar sunrun ,rr_.j 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 MA LIC:1708481156888 KRUTIAK RESIDENCE 2 SATURN LN `i SOUTH YARMOUTH,MA 02664-4335 0 UTILITY ACCOUNT 14854970036 METER:2308538 1 BATTERY RACKING DETAIL S i l RDC:MA-03 ---- DRAWN BY:DIN 1.7 SCALE:NOT TO SCALE DATE 05/22/2021 REVISION:O B • Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size(Watts) 11700 Tag Description Wire Gauge R of Conductors/Color Conduit Type Conduit Size to, AC System Size(Watts) 7600 1 DC-to-DC Converter Output(PV Wire) 10 AWG 2(V+,V-)B/R Free Air N/A g Total Module Count 36 1 EGC(Bare) 6AWG 1 BARE Free Air N/A u m 2 DC-to-DC Converter Output(THWN-2) 12 AWG 4(2V+,2V-)B/R FMC 1/2" w E N O 2 EGC(THWN-2) 12 AWG 1(GRN) FMC 1/2" y cC 2 Ti� 3 DC-to-DC Converter Output(THWN-2) 12 AWG 4(2V+,2V-)B/R EMT 1/2" ac Fes- V 8 3 EGC(THWN-2) 12AWG 1(GRN) EMT 1/2" '� 1 8 4 Inverter Output(THWN-2) 8 AWG 3(L1,L2,N)B/R/W EMT 3/4" x Q 4 Com Line(600V Rated Ethernet) 4/24 AWG 7(A,B,G,R1,R2,V+,V-) EMT 3/4" A 4 EGC(THWN-2) 10 AWG 1(GRN) EMT 3/4" D 5 Backup Panel Feeders(THWN-2) 4 AWG 3(111,112,1N)B/R/W EMT 11/4" 5 Current Transducer(600V Rated Ethernet) 4/24 AWG 4(2S+,25-)G/Gw/O/Ow EMT 1 1/4" S EGC(THWN-2) 4 AWG 1(GRN) EMT 1 1/4" 6 Load Circuit(THWN-2) 12 AWG 8(411,4N)B/W EMT 1/2" 6 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" 0 7 Battery Output(THWN-2) 10 AWG 2(V+,V-)B/R EMT 1/2" O 7 Corn Line(600V Rated Ethernet) 4/24 AWG 4(G,H,CH,CL)G/Gw/O/Ow EMT 1/2" C ' 7 FXI'(THWN-7) 10 AWn 1(GRN) FMT 1/7" f: 8 Backup Panel Feeders(THWN-2) 4 AWG 3(111,112,19)B/R/W EMT 1" C C 8 EGC(THWN-2) 4AWG 1(GRN) EMT 1" •� ` +4 C i Battery will charge from PV Array.Battery will charge to home. • Z Battery will also discharge to grid when requested by Eversource > o'rt - v A Installers Note(s):LOADS SHALL BE RELOCATED TO USE v LESS THAN 6'OF WIRE-210.12(D)EXCEPTION New Square D HOM48L125GRB 240V/125A StorEdge SE7600H-USS Backup Load Panel CONTAINING RELOCATED Point of Interconnection,Load Side cn 'Conforms to 4AsI EXISTING 220A,AND 2 ISA SINGLE POLE 705.12)8))1))b)&(B)(2) a C12.1-2008 Inverter DC Disc LOAD(S).Main breaker shall comply with is Rapid Shutdown 408.36(0) Disconnect Existing Murray 240V/125A Service y n 1 LG RESU1OH Battery Panel,Single Phase,with 1004 Main 540 Max Capacity:9.8 Disconnect 0 Q kWh....._. PV System SMART Meter �6DA j 5 Z vs K K •, ocl n� SquareD DU222RB m ---"Ti?' 7 ,i i r 240V/60A unfused, a Q o l' - �i10t} --' NEMA3R,with 75°C N N O N u�rr.c _ terminations 11 A Z Z may STRING 2:18 PV 1 2 fe I o fVf MODULES II o • SHEET W/OPTIMIZERS °°\ J ----- Q --.44-- T �_ NAME: fff _. LINE t[� n m __ _ __.__V_( _ y } \ 100 y e STRING 1:18 PV Q �— 6 T. _ - 3 2 MODULES °°° NEMA 3R q 1OAL�\ 11 z1 _ M G W/OPTIMIZERS Junction Box \ Qq 4 SHEET ■ ■ \ 1 • Q 404 SiDA NUMBER: f� �I /1 _ • T ,,__99 36 PV MODULES PER INVERTER=]111700—WATTS — T * - •r-riLAg-o4'NR d STC Visible/Lockable'Knife Interconnection Device Minimum DEC size6 nir vi AC Disconnect AWG copper W Inverter/Optimizer Specs PV Module Rating 41 STC Conductor Calculations w Optimizer SolarEdge P370 Module Make/Model lA Solar JAM60S17-325/MR m Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature g DC Input Power 370 Watts Max.Power-Point Current(Imp) 9.57 Amps d , v+ calculations from Table 310.15(B)(1)&310.15(13)(2)and raceway fill adjustments from 310.15(C) c " a DC Max.Input Voltage 60 Volts Max.Power-Point Voltage(Vmp) 33.97 Volts w ? 0 m (1).Conduit on the roof shall be installed no less than 1"above the roof deck. v a DC Max.Input Current 13.75 Amps Open-Circuit Voltage(Voc) 40.87 VoltsPV Circuit conductor ampacity is constrained using the 75'C column with the continuous duty c cc m • .ti DC Max.Output Current 15 Amps Short-Circuit Current(Isc) 10.23 Amps uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments A a > > Max.string rating inverter dependent.See SE documents. Max.Series Fuse(OCPD) 20 Amps without the continuous duty uprating per 690.8(B),whichever results with a larger wire size. 2 ''I 0 ` r, E u Inverter Make/Model StorEdge SE7600H-USS Nom.Max.Power at STC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity in the 75°C column or the 90°C column with the x CEC Efficiency 99 % Max.System Voltage 1000V/1500V DC(UL) relevant ambient temperature and raceway fill adjustments,whichever is less(110.14(C)& AC Operating Voltage 240 Volts Voc Temperature Coefficient -0.272 I %/C 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, Cont.Max Output Current 32 Amps the continuous duty uprated current. DC Max Input Current 20 Amps ASHRAE 2017-BARNSTABLE MUNICIPAL More information about conductor calculations can be provided upon request. Highest MonthlyCalc.Ex:Wire Ampacity x Ambient Temp.Corr.Factor x Conduit Fill Adj.Factor>=Output Current Input Short Circuit Current 45 Amps 2%D.B.Design Temp.:29.5°C Max Output Fault Current 40 A/20 ms Lowest Min.Mean Extreme D.B.:-19.2°C (Tag 1 Under Array): DC-to-DC Converter Output:10 AWG rated 30 A, 30 A>=18.75 A i Batter Specs (Tag 2 Attic): 0 Battery Make/Model LG RESU1OH DC-to-DC Converter Output:12 AWG rated 30 A, 30 A x 0.76 x 0.8=18.24 A>=15 A Max/Usable Energy Capacity 9.8/9.31 kWh 0 --- (Tag 3 On Roof): Max Voltage 520 Volts DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>=18.75 A Max Charge Current 11.9 Amps (Tag 4 Attic): �r Max Discharge Current 14.3 Amps C^ C Max Power 5 kW Inverter Output:8 AWG rated 55 A, 55 A x 0.76 x 1=41.8 A>=32 A =` (Tag 5 Exterior): / C C Max Surge Current 18.9A/10 sec Backup Panel Feeders:4 AWG rated 85 A, 85 A>=50 A •� N Max Surge Power 7 kW/10 sec > ✓� N (Tag 6 Exterior): Short Circuit Output Current 4.5 kA/400 ms Load Circuit:12 AWG rated 20 A, 20 A>=20 A y (Tag 7 Attic): v Battery Output:10 AWG rated 30 A, 30 A>=25 A u` (Tag 8 Exterior): Backup Panel Feeders:4 AWG rated 85 A, 85 A>=50 A o, N Other Notes a, 8 •Designed according to and all code citations are relevant to the 2020 National Electrical Code. n •All interior raceways carrying DC current shall be metallic. g w 0 N di Voltage and OCPD Calculations(690.7,690.9) '>• Z m m •+ PV Source Max Circuit Voltage:Module Voc x(1-(AT x Voc Coeff))[art.690.7(A)) COI LO N JAM6OS17-325/MR:40.87 V x(14(25 C--19.2 C)x-0.272%))=45.78 V<=60 V .. r a m N N . N 2 2 to Inverter Output Circuit(s):Listed Output Current x 1.25[art.690.9(B)) SHEET Inverter 1:SE7600H-US Max Output=32 A x 1.25=40 A<=40 A(OCPD) NAME: N al al O m Z o. SHEET NUMBER: N W All AC Disconnecting Means-AC Disconnect(s), Installed within 3 ft of Rapid Shutdown Switch,Reflective,and shall be placed on Combiner Panels and Load Centers•er 690.54 Inverter 1 DC Disconnect per 690.53 Conduit,Raceways,and 1-Boxes(Labeled Every 10')and perper ( )( ) PHOTOVOLTAIC AC DISCONNECT g both Panel Exterior&next to Main Disconnect 690.56 C 2 Reflective per 690.31(D)(2) s MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCH MAXIMUM AC OPERATING CURRENT' 32/{ d ? _ OF PV SYSTEM: 480 v PHOTOVOLTAIC POWER SOURCE FOR SOLAR PV SYSTEM NOMINAL AC OPERATING VOLTAGE: 240 V v 8 74 O. = C YN :4;i1 0 PV System Disconnects per 690.13(9) PV with Rapid Shutdown Switch,Installed within 3 ft of Service Disconnecting � iN E PV SYSTEM DISCONNECT Means with min.3/8"black capitalized text on yellow background&3/16" y black ca•italized text on white bac :round•er 690.56 C z e d r F € $ , a Q TURN RAPID SHUTDOWN Allis 0 ' SWITCH TO THE OFF"POSITION TO SHUTDOWN PV SYSTEM BEwas44 AND REDUCE c SHOCK HAZARD �>... c IN ARRAY Ell Plaque/Directory at Service Equipment Location and Power Production System Disconnecting r— vs w CAUTION: MULTIP SOURCES`OF POWER DC Disconl ect(s),Load Centes,and Disconnecting Means- `d biner POWER TO TH UILpING ASO SUPPLIED FROM THE ' Panels per 690.13(89&690.15(C) nl AS a FOLLOWINGDICESW H DISCONNECTS LOCATED AS ELECTRICAL SHOCK HAZARD cc n- 1 _ SHOWN TERMINALS ON THE LINE AND g LOAD SIDES MAY BE ENERGIZED O Nii IN THE OPEN POSITION Z m R f Power Source Output Connection,Adjacent to > Z w w � 1111111168211.11 Back-fed Breaker•er 705.12(8)(3)(2) � —N ; � �MINNOI� /1Battery System/ perO O Q Q m T: � ESS Disconnect 480.7 F &706.15 C N ti N � ul ! s�®� NOMINAL ESS AC VOLTAGE: 240 V z Z " METER AND MAIN POWER SOURCE OUTPUT CONNECTION SHEET §. SERVICE THIS OVERCURREDO OT RELOCATE PROTECTION DEVICE NOMINAL ESS DC VOLTAGE: 400 V NAME: MAXIMUM ESS DC VOLTAGE: 52ov ACDISCONNECT Three Power Sources in Main Service Panel v, , ' and Sub Panel(s)per 705.12(C) •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER 10 a m DC DISCONNECT 33 LOCAL AH.1 REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED '8...' PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS• SHEET ._____ THREE POWER SOURCES SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING NUMBER: REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS co SOURCES:UTILITY GRID,BATTERY OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING TO rn WITHSTAND THE ENVIRONMENT NV RONMENTNOT AND SHALL NVOLVED•SIGNS/LABELS SHALRITTEN• LNOTSHALLLS OF DURABILITY NOTCOVER EXISTING MANUFACTURER LABELS W SITE PLACARD SHOWING ADDITIONAL POWER SOURCE WARNING C MAXIMUM DC VOLTAGE OF PV SYSTEM ".V ® RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM ( 7 ' AND DISCONNECT LOCATIONS.PLACARD SHALL BE 10 THREE POWER SOURCES g JSOURCES:UTILITY GRID,BATTERY MOUNTED ON EXTERIOR OF ELECTRICAL PANEL d a, AND PV SOLAR ELECTRIC SYSTEM d Z c WARNING MAIN BREAKER DE-RATED & °C 2 C SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND DUE TO SOLAR CIRCUITS „ a L PHOTOVOLTAIC POWER SOURCE \ ,� J WITH RAPID SHUTDOWN C LOAD SIDES MAY BE ENERGIZED '"AMPS MAX ALLOWED illn ° o /�/ E IN THE OPEN POSITION DO NOT UPGRADE '� �`m. > 5 PHOTOVOLTAIC AC DISCONNECT �� WARNING NOMINAL ESS AC VOLTAGE:•••V C PV SYSTEM DISCONNECT �� MAXIMUM AC OUTPUT CURRENT:""A POWER SOURCE OUTPUT CONNECTION 1 2 NOMINAL ESS DC VOLTAGE:"""V \� NOMINAL AC OPERATING VOLTAGE:***V `-�j DO NOT RELOCATE 1 MAXIMUM ESS DC VOLTAGE:••"V THIS OVERCURRENT PROTECTION DEVICE 1- 0 0 ROOFTOP ARRAY BATTERY DC 0 C DISCONNECT 12 •> c INSIDE IN •� N N O e IF APPLICABLE > m w illV 1 12 4 O6 �i 0 INSIDE rO1v 0___ / PANEL S P$ . 3 Ci) 6 ®RAT6 O8 10 O O 0 a EVERY 10'AND Oq b g °,° WITHIN 1'OF ELBOWS it" Lo0 w 9 I I I 5gm— Dc M WW ' M a a m o© rm, DISCONNECT INSIDE z z 0 Ln — — r _� ___ _ --- ___. -__.. SHEET ROOFTOP COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C MAIN SERVICE NAME: JUNCTION BOX O SOLAR INVERTER (WHEN USED) DISCONNECT(WHERE (WHERE REQUIRED) DISCONNECT BACKUP INTERFACE DISCONNECT PANEL c REQUIRED) N ***-value calculated for each a m TYPICAL SOLAR GENERATION INSTALLATION account,for specific value see the 3 3 a (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page SHEET NUMBER: •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS•SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE et ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS u.I • BONDING NOTES �=BONDING PATH MODULE FRAME ROCK-IT COUPLING I_ I�� MID CLAMP �., 4 _ I/ 1 -4 - - ROCK-IT ROCK IT SLIDE UL2703:2015 LISTED PEDESTAL m-. 'Y BONDING CLIP MO- x- �n BONDS SOLAR MODULE I FRAME TO OPTIMIZER ;- I OR MICRO INVERTER ", 1 , �I II I, `L. � OPTIMIZER MOUNTED 11 OROCK-IT INTEGRATED BONDING WITH UL2703 TO MODULE FRAME NOTTOSCALE �_ I, iI ili !'. 3OPTIMIZER BONDING DETAIL WITH UL27030 NOT TO SCALE PV MODULE TO ACT AS AN ACTIVE GROUNDING COMPONENT TO EGC iI."Ts maim i!mg • GROUNDING LUG(SEE S1.0 DETAIL#2) •--• E-W BONDING PATH. H_MIN I I. I I I.___ ,=M_ E_Jim _H.11 MM. 1.2 _..I n IM IN-S BONDING PATH,SEE DETAIL#1. .0 o ROCK-IT COUPLING vivint.Solar 1111111- �� m —�� f 11 _,sunrun 1800 ASHTON BLVD.LEHI,UT,84613 1111 ❑ ROCK-IT COUPLING MALe717 e4l488A II �� II _ IIKRU 21 sA RERNIDENCE ry SOUTH YARMOUTH,MA 02684-4335 UTILITY ACCOUNT 14854970036 ¢ METER 2308538 7 ( )SYSTEMNNTTLBONDING LAYOUT WITH UL2703 BONDING DETAILS R M� E 5.O1 DRAWN BY:DIN h SCALE:NOT TO SCALE DATE:05'2212021 - REVISION:0 i