Loading...
HomeMy WebLinkAboutBLDE-22-006009 NteCommonwealth of Official Use Only Ems, Massachusetts Permit No. BLDE-22-006009 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:4/20/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 45 SKIPPER LN Owner or Tenant NUNES GUILHERME Telephone No. Owner's Address 45 SKIPPER LANE,YARMOUTH PORT, MA 02675 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(28 Panels 9.1 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above 0 In- ❑ No.of Emergency Lighting grnd. grad. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. TotaloNo.of Alerting Devices n No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd,Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) ❑ owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 7.. 004, l *= RECEIVED r` O 'al Use Onom ,nweaIh o/massachuseltd ettAPR1UZZ �� Permit No. 6 00 61 " i .a4menore Serviced . -111--e Occupancy and Fee Checked ''-,T-,� +I u iL[B : r-. "i- PREVENTION REGULATIONS [Rev. 1/07] (leave blank) By _ APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: (1-18-a% City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) S 1 Owner or Tenant ui Iherrm Upp Telephone No.algigaiec 11-1 Owner's Address o as Q UV Is this permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box) Purpose of Building Pli)ftt'iUtility Authorization No. Existing Service (m Amps /AC Volts Overhead d Undgrd❑ No.of Meters I New Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters Number of Feeders and Ampacity ff Location and Nature of Proposed Electrical Work: fns-01 I Q-I m (-i r( `ph(� C`�UC k ic. f knr 5i le,m: ; x ryas q .1 (monied Completion of the following_table may be waived by the Inspector of Wires. No. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal r--1 Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Ain 4c ,, Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Valu o .. n cal Work: , 'v�(`,' (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such covea is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE [ BOND ❑ OTHER ❑ (Specify:) I certify,under t •p, ns and pen,hies of perjury,that the information on this application is true and complete FIRM NAME: k it `, LIC.NO.: Licensee: { I 1 i_ A- Signature / _ / LIC.NO.: (If applicable gnter ;'exempt"iW't e license number 1' e,1,. Bus.Tel.No.. �- Address: CC/5, Sh RIlU(1P/d1l , MM , L )72O Alt.Tel.No.: *Per M.G.L.c. 147,s?57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:9100W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), , - SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(28)JA SOLAR:JAM60S17-325/MR MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. a P- �°-- - 0 - ° PV-2.0 SITE PLAN SE7600H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • PV-3.0 LAYOUT •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL - - - TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. w xi PV-4.0 ELECTRICAL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE SP -SNR MOUNT&SKIRT GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER M CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. ( '�, ATTIC VENT SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. -] FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. L, PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). O AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC •10.23 AMPS MODULE SHORT CIRCUIT CURRENT. Q DC DISCONNECT(S) FIRE SETBACKS •15.98 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12)B)(2). E`�"''- CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION SHOWN AS DASHED L J SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT (E) EXISTING 635 MYLES STANOISH BLVD,TAUNTON.MA,02780-7331 PHO ESS ENERGY STORAGE SYSTEM FAX 0E3 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC GUILHERME NUNES ,: • ., ;I, MSP MAIN SERVICE PANEL 45 SKIPPER LN,YARMOUTH, (N) NEW MA,02675 - NTS NOT TO SCALE OC ON CENTER TEL.(508)922-8264 .3'I'! "'4 . PRE-FAB PRE-FABRICATED APN:YARM-000115-000187 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC 223R-045NUNE RSD RAPID SHUTDOWN DEVICE • TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL Rusabh Gandhi V VOLTS W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:A 2/16/2022 PAGE PV-1.0 SITE PLAN-SCALE=1/16"=1'-0" PL ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SQFT) AR-01 38° 187° 201° 507 illi I P( \ PC PL a PL e' a i r ° • ° 4 (E)DRIVEWAY a' / --0-1-E� ,.iINV (N)ARRAY AR-01-- - 1111:11 (E)RESIDENCE tl sunrun #160120 L hes MYLES STANDISH BLVD,TAUNTON,MA.02780-7191 PHD.0 E FAX 0 CUSTOMER RESIDENCE: GUILHERME NUNES 45 SKIPPER LN,YARMOUTH, s' MA,02675 PL ------ PL -__ TEL.(508)922-8264 PL ------_________ PL APN:YARM-000115-000187 �- PL -----______________ PROJECT NUMBER: PL 223R-045NUNE DESIGNER: (415)580-6920 ex3 Rusabh Gandhi SHEET SITE PLAN REV:A 2/16/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF 9 yP Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 8'-1" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: COMP,SEE DETAIL SNR-DC-00436 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: D1-AR-01-SCALE:3/16"=1'-0" 5/16"x 4.5",2.5"MIN EMBEDMENT AZIM:187° STRUCTURAL NOTES: PITCH:36° • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANC REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS 11'-3" { FOLLOWS: ..ALLOWABLE ATTACHMENT i3- ._$_.._ ...._ 11,-2" {,_2„ SPACINGLNST INDICATEDUED { t 9'-6° PLANS TO BE REDUCED BY ON �; I 50% - 0 0 0 0 ..ALLOWABLE OVERHANG INDICATED ON PLANS TO BE _.__.-, � 1/5TH OF ALLOWABLE 1,$„ ATTACHMENT SPACING 0 ❑ 0 0 'j Cl 9 ❑ 0 B..t ❑ ❑ o __. _ INDICATED ON PLANS 1T-3" ❑ ❑ C O ❑ ❑ ❑ ❑ ❑ 1V-8" sunrun 9,_11„ ❑ ❑ 6--6'TYP---J K n ❑ Cl 0 C El #180120 n n n n n n n n n 885 M O LES STANG,.BLVD,TAUNTON,MA,02780-7331 10" PHONE .0 22'-4"____ j CUSTOMER RESIDENCE: 44'-9' __ - ___ _--- - __ GUILHERME NUNES -- -�" 45 SKIPPER LN,YARMOUTH, E.�s OVA F k4 0 MA,02675 ' 'C TEL.(508)922-8264 oy. SAMUEL APN:YARM-000115-000167 3r BROWN0 r--1 PROJECT NUMBER: Y -No y 223R-045NUNE DESIGNER: (415)580-6920 ex3 ANAL Rusabh Gandhi &good on.2/17/2022 SHEET LAYOUT REV:A 2/16/2022 PAGE PV-3.0 i 120/240 VAC SINGLE PHASE SERVICE METER#: < O EVERSOURCE2372853 UTILITY GRID SUPPLY SIDE TAP (N)LOCKABLE I EXISTING 100A BLADE TYPE (N)MA SMART SOLAREDGE TECHNOLOGIES: MAIN BREAKER FUSED AC (N)LOCKABLE UTILITY SE7600H-USSN WITH DISCONNECT BLADE TYPE REVENUE REVENUE GRADE METERING 3 AC DISCONNECT Apo METER 3 7600 WATT INVERTER JUNCTION BOX PV MODULES Q OR EQUIVALENT n JA SOLAR:JAM60S17-325/MR EXISTING �h� / (28)MODULES < 100AIWim. I i 0� o O V `'^ _ �-� -� (l)// OPTIMIZERS WIRED IN: FACILITY PANEL `YY (1)SERIES OF(14)OPTIMIZERS LOADS 40A FUSES I (1)SERIES OF(14)OPTIMIZERS l�ao°Z SQUARE D SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P370 120/240VAC 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 sun r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 605 MYLES STANDISH BLVD,TAUNTON.MA.02/60-7631 PHDNE0 FAX 0 CUSTOMER RESIDENCE: GUILHERME NUNES 45 SKIPPER LN,YARMOUTH, MA,02675 MODULE CHARACTERISTICS TEL.(508)922.8264 JA SOLAR:JAM60S17-325/MR: 325 W P370 OPTIMIZER CHARACTERISTICS: APN:YARM-000115-000187 OPEN CIRCUIT VOLTAGE: 40.87 V MIN INPUT VOLTAGE: 8 VDC MAX POWER VOLTAGE: 33.97 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: SHORT CIRCUIT CURRENT: 10.23 A MAX INPUT ISC: 11 ADC 223R-045NUNE MAX OUTPUT CURRENT 15 ADC DESIGNER: (415)580-6920 ex3 Rusabh Gandhi SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 9100 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE 480 V REV:A 2/16/2022 SYSTEM OPERATING CURRENT: 22.75 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR HARING THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), WARNING: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). PHOTOVOL AIC •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(8) POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN.ABOVE AND BELOW PENETRATIONS. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2020:BB0.31(D)(2),IFC 2012: DUAL POWER SUPPLY 605.11.1.4 SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.58(C((2),IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: l 4„ J 705.12(8)(3)(2) ---__ SOLAR PV SYSTEM EQUIPPED #160120 PHOTOVOLTAIC SYSTEM SOS MALESST350IsHBLVD,TAUNTON,MA,oneo-z33+ COMBINER PANEL WITH RAPID SHUTDOWN FFPHONE 0 .0 DO NOT ADD LOADS CUSTOMER RESIDENCE: LABEL LOCATION: GUILHERME NUNES PHOTOVOLTAIC AC COMBINER(IF 45 SKIPPER LN,YARMOUTH, APPLICABLE). MA,02675 PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN SWITCH TO THE"OFF" KILMAILIOSLIMINTRICTEL.(508)922-8264 POSRION TO SHUT DOWN AP N:VAR M-000115-000187 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT'31.67 AMPS SHOCK AH ARD IN THE 11223R-045N UNE NOMINAL OPERATING AC VOLTAGE: 240 VAC Y. DESIGNER: (415)580-0920 ex3 LABEL LOCATION: Rusabh Gandhi AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. • SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE ON DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 2/16/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0