Loading...
HomeMy WebLinkAboutEngineer PlanSURVEY WITH EXISTING TOPOGRAPHY, UTILITIES AND oROPERTY BOUNDARIES PROVIDED BY DEMAREST ,AND SURVEYING, PLS DATED 18 NOVEMBER 2022. BE OF EL 0 Q ,. N EXISTING SYSTEM SEE NOTES 0 AJ 4 2,000 GAL. H-10 2-COMPARTMENT TANK (COMBINED 1,500 GAL SEPTIC 1500 GAL PUMP CHAMBER) �pej✓ < } ti\ /d pp MAP 39 _e PCL. 152 N i a 0 E r iu r v M 0 v i� q 0 31 CHECKERBERRY LANE ASSESSORS MAP 40 PARCEL 12 i a rT y SITE PLAN Q� SCALE: 1" = 20, < 0 20 40 vi V c� p 0.. 4 a N =PAZ Cli TOF =15.3 sa A :d S ab 2j M/ 0po C a pE aa. . T SHGW 1=9.3 = SEPTIC TANK AND PUMP CHAMBER SHALL BE WATERPROOFED BY MANUFACTURER OR COATED Wt THOROSEALS. A AIT1110 COVER WITH GEOTEXTiLE MAT CONDUIT TO SUPPLIED WITH ELJEN GSF MODULES CONTROL PANEL. 9" MIN, TO 36" MAX. ASTM C33 SAND. NEMA 4X COVER SEE SYSTEM NOTES. JUNCTION BOX Q 3" MIN •i it ISLE t ILTER 2" PVC SWING CHECK VAL r BUOYANCY CALCULATIONS 2,000 Gal.,,2-Compartment Tank Tank & Soil: 20,000 lbs + (12' x 6.5' x Tx 100 Ibs/ft� _ 27,800 lbs Water Displaced: I Z x 6.5' x 2.5' x 62.4 lbs/fe _ 12,168 lbs < 27,800Ibs [OK] 4 INCH INSPECTION PORT, PERFORATIONS ABOVE ELJENS TO BE 14,38 COVERED WITH TYPAR SOCK DISTRIBUTION -. ,::. '' TOS BOX (H-10) i 37' 1/8" WEEP HOLE BOS PVC UNION BALL VALVE. 18 ELJEN GSF B43 MODULES: 3, _ _2" 37' L X 8' W BED CONFIGURATION SURGE CAPACITY (W) SPACING BETWEEN MODULE ROWS -12" _ACTIVE VOLUME (IS") N6E PUMP SUBMERGENCE (2.5") SEASONAL HIGH GROUND WATER (SHGW) _ LEGEND 2,000 GALLON TWO COMP. � WATER SURFACE ELEVATION TANK (H-10) GAS BAFFLE SYSTEM PROFILE NOT TO SCALE TCHEN BATH BED BED BED FLOOR PLAN HED BASEMENT) outh Health Department U OVEDs Date L DEC 012022 HEALTH DEPT. SAS Design Tie -cut Table X �Y A 29, V 49.4' B 39.7' 53, 4' C 33.7 30.2' D 33.0' 22.5' LOCUS 31 Oheckerberry Ln VICINITY MAP NOT TO SCALE VARIANCES / SITE NOTES: 1. PROPOSED SYSTEM COMPONENTS ARE LOCATED IN FEMA FLOOD ZONE X: 0.2% ANNUAL CHANCE OF FLOODING. 2. THE PROPERTY IS NOT LOCATED WITHIN A ZONE it. 3. NO DRINKING WATER WELLS WITHIN 100 FEET OF PROPOSED SYSTEM. GENERAL NOTES 1. THIS PLAN IS INTENDED FOR THE DESIGN OF THE SEWAGE DISPOSAL SYSTEM ONLY AND iS NOT TO BE USED TO ESTABLISH NEW OR EXISTING PROPERTY LINES OR DWELLINGS. 2. LOCATION OF WATER, GAS AND ELECTRIC UTILITY LINES IS APPROXIMATE. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING DIGSAFE AT 1-888-344-7233 AND THE WAREHAM WATER DEPARTMENT PRIOR TO CONSTRUCTION. 3. INSTALLATION SHALL BE IN ACCORDANCE WITH THE STATE ENVIRONMENTAL CODE, TITLE 5 (310 CMR 15.000), THE LOCAL BOARD OF HEALTH REGULATIONS, AND THE ELJEN MA DESIGN AND INSTALLATION MANUAL, 4. THE CONTRACTOR MUST HOLD A VALID INSTALLER LICENSE IN THE TOWN OF YARMOUTH.' 5. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND THE LOCAL BOARD OF HEALTH OF ANY CHANGES TO THESE PLANS. 6. CONTRACTOR SHALL CALL FOR INSPECTIONS AND APPROVALS FROM THE BOARD OF HEALTH AND THE ENGINEER AFTER: 6.1. EXCAVATION OF SAS AREA EXPOSING THE BOTTOM OF SYSTEM. 6.2. INSTALLATION OF SYSTEM COMPONENTS PRIOR TO BACKFILL. 7. ALL PIPING AND FITTINGS SHALL BE SCHEDULE 40 PVC UNLESS OTHERWISE SPECIFIED. 8. FINISHED GRADE OVER THE SAS SHALL HAVE A MINIMUM 2% SLOPE, 9, EXISTING CESSPOOLS TO BE PUMPED DRY, FILLED WITH SAND AND ABANDONED, 10. NO GARBAGE GRINDER SHALL BE INSTALLED AT THE EXISTING DWELLING. 11. CONTRACTOR SHALL INSTALL IMPERVIOUS BARRIER 5 FT FROM THE SAS ON ALL SIDES. GPD DESIGN CALCULATIONS 3 Bedrooms x 110 GPD/Bedroom 330 SEPTIC TANK (Per 310CMR15.233) Single Compartment : 2 Days Flow 660 gallons Minumum Total Volume- 15U0 gallons SOiL ABSORPTION SYSTEM: Loading Rate (310CMR.15): 0,74 GPD/sq ft Area = 330 GPD / 0.74GPD/sq ft 445.9 sq ft Select Eijen B43 Modules: Bed Configuration Eijen B43 Modules are a MassDEP i/A Technology approved for Remedial Use that allow for reduction in offset to groundwater to 3' (for soils with <2min/in•) Total Modules required (Eijen MA Manual) 15 Total Modules provided 1s Minimum Basal Area Required (Eijen MA Manual) 272.0 sq. ft SAS Area = 8 ft x 37 ft 296.0 • ft Test Hole 1(Elev. 13.0) DEPTH (inches) HORIZON / LAYER TEXTURE (USDA) COLOR (Munseli) 0 -10 A Loamy Sand 10YR3/1 0- 32 B Loamy Sand 10YR6/8 32- 120 C Medium Sand 10YR7/4 Notes: Groundwater observed @ W, (5.6) - Adjusted SHGW @ 44.5"(9.3) Groundwater Adjustment Index Well _ MlW-89 Water Level Range Zone B Water Level for Index Well (10/22) 9.43 Adjustment 3.7 Groundwater (observed) 5.6 SHGW (adjusted) 9.3 Schedule of Invert Elevations Location Design As -built 4" sewer invert @ foundation 12•80 4" septic tank in 11.30 2"septic tank out (Pumped 11.05 4 @ D-box in 13.62 3" @ D-box out 13.45 3" @ SAS Chamber in 13.38 IlTop of System (TOS) 13.38 Bottom of Chambers 12.E gotta of Sand (BOS) 12,30 Select Pump INPUTS) Pump Liberty LE41A-3 Volume Pump Tank 501) 1022S Max. Water Depth of Tank 4.00 feet invert Elev. inlet 11.05 feet Elev. Discharge Into Dbox 13.62 feet Pipe Len h 40.0 ft Pipe Diameter 2 in. SCH 40PVC Added headloss 10 feet k Value for Friction Loss 6.6 unitiess CALCULATIONS TDH = AH + Pipe Friction + Minor Lasses AH = Discharge Elevation - Pump low Level pH' = AH +Added losses ball valve adjustment Minor Losses = kvz/2g OUTPUTS AH 6.36 feet AH' 16.36 feet Minor Losses 0,9521 feet Pipe Friction 0,9071 feet TDH 18.2 Ifeet DUTY POINT (see graph) CZ(Flow Rate) 32 JGPM TDH 18.2 Ifeet Determine Float Heights and Dose Volume Min. Dose Volume Required* 185 gal./ dose Volume of Pressure Pipe (drain back)._5.0 gallons Adjusted Total Dose Required 190 allons Volume per Depth of Tank 135 al. ft inches gallons Min. Pump Submergence 2.5 28 Active Volume Depth 17 190 Sur a Volume De th 6 68 Depth Emergency Storage 30.0 1 338 7.05 7.26 8.67 9.17 Elev. Bottom of Tank interior) Elev. Low water level pump OFF) Eiev. High water level (pump ON) Elev. Hi h Alarm PONAL DATER LTD ENGINEERING SERViCES 85 Courtland Street Providence, RI 02909 P: +1 (508) 954 0677 E: jay@robialWater.com CONSULTANTS: a t: a SPEAKMAN EXCAVATING LLC 235 Great Western Rd Dennis, MA 02660 P: +1 (608) 432 5565 E: info@speakmanexcavating.com -._-`-_ --- T----i I I I I ( I I i I I I i 12-0142 I - i i i I I I SG DAN I A. SPEAKMAN_� � v No 394Q2 !�•Ap SeStS,�p� I � I No. REVISION/SUBMISSION DATE COPYRIGHT 2022 - Robial Water Ltd, This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of Robial Water Ltd. PROJECT No. t5s.2022.048 SHEET TITLE: SITE LAYOUT SYSTEM DESIGN SHEET SIZE: 18 IN, X 24 IN, (ARCH C) DATE: 05 December 2022 SHEET NUMBER: SHEET 1 Of 1 PROJECT: I RESIDENTIAL ONSITE WASTEWATER TREATMENT SYSTEM REMEDIAL CONSTRUCTION 31 Checkerberry Lane Yarmouth, MA 02633