HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. S 2 Lot ��1:7 Zone of Contribution: In_ Out ' Acreage /� e G
Commercial: Residential: 1.----
Street: /8 0 jam' r r-c.! < , 51
Village: Floor Plan: V # Bedrooms:
Owner: Installer: R. (DU /'
Address: Phone:
Phone:
Builder:
Address: Engineer: .-ft.,�! Neer / ,t, 1/ -
Phone:
Phone:
N/A YES NO
1. Required#of copies received ,.*/
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: v/
6. Benchmark indicated and shown-NGVD if near wetlands C./
7. Septic tank minimum 10 ft from foundation, deck Var.: L
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: I I
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: /
15. System not in top or subsoil(A,B horizons)or 5' removal I
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", %"preferred /
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal /
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade /
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes t/'
27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size L----
28. Septic tank/pump chamber to be factory waterproofed 1.---
29. Vent provided if leaching below 3 feet,under driveway/parking L/
30.Buoyancy calculations for tank/pump chamber l✓
31. Engineer to inspect and certify soils: wall: commercial:,
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature _/
33.H-20 loading is subject to vehicular traffic,groundwater /
34.Title V Application and permit fee,installer signature
35. Foundation footing min.2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map l
Plan reviewed by e- _ 600,