Loading...
HomeMy WebLinkAboutSouth Yarmouth MA 301729 SET-063022F.D.F.O.FIN.FL.EXT.EXIST.EQ.ELEC.EQUIP.DWG.EA.EL.D.S.DR.DIM.DN.DISP.DIA.D.F.FLOOR DRAINFACE OFFINISHFLOOREQUIPMENTELECTRICALEXISTINGEXTERIOREQUALDOWN SPOUTELEVATIONDRAWINGEACHDOORDIMENSIONDISPENSERDIAMETERDRINKING FOUNTAINDOWNCONST.DTL.DEPT.CONT.CONC.CMCOL.CMUCLOS.CLG.BSMT.BOT.C.T.C.L.BTWN.BM.BLDG.ALT.APPROX.BD.CONC. MASONRY UNITCONSTRUCTIONDEPARTMENTCONCRETECONTINUOUSDETAILCONSTRUCTION MGR.COLUMNCEILINGCLOSETBASEMENTCERAMIC TILECENTER LINEBOTTOMBETWEENAPPROXIMATEALTERNATEBEAMBUILDINGBOARDA.F.F.ALUM.A/CA.D.@&ALUMINUMAIR CONDITIONINGABOVE FINISH FLOORAREA DRAINATANDCOMBODUNKIN'/BASKINDUNKIN'/TOGO'STOGO'S/BASKIND.B.I.DUNKIN' BRANDS INC.C.S.CONSTRUCTIONSPECIFICATIONSON CENTERNOMINALOVERALLNOT TO SCALENUMBEROPENINGOPTIONALPROPERTYPLYWOODPLUMBINGPAINTEDPOLY VINYL CHLORIDEPER SQUARE INCHPER SQUARE FOOTPLASTIC LAMINATEOUTSIDE DIAMETERP.V.C.PTD.P.S.I.PR.PROP.P.S.F.PLYWD.PLUMB.PAIROPT.PL.P.LAM.O.D.OPNG.PLATEN.T.S.O.C.O.A.NO.NOM.HOLLOW METALHEADERGYPSUM BOARDHARDWOODGALVANIZEDINTERIORINSULATIONHORIZONTALLAMINATEKITCHENLAVATORYMANUFACTURERMAXIMUMMECHANICALMASONRYMOUNTEDMISCELLANEOUSMINIMUMNOT IN CONTRACTINSIDE DIAMETERMASONRY OPENINGM.O.MTD.N.I.C.MIN.MISC.MECH.MFR.MTL.MAX.MAS.METALLAM.LT.LAV.KIT.JT.LIGHTJOINTI.D.INT.INSUL.HGT.HORIZ.HEIGHTGYP. BD.HDWD.H.M.HDR.GALV.GA.GAUGESECTION NUMBERSHEET NUMBERSECTIONDETAILDETAIL NUMBERSHEET NUMBERDETAILDOOR MARKDOORKEY NOTEEQUIPMENT TAGFINISHESROOMFINISHNUMBERROOMNUMBERCOLUMN REFERENCE GRIDSPARTITION TYPEINTERIOR ELEV. INDICATORELEV. NUMBERSHEET NUMBERTOP OF PLATET.O.P.VINYL WALL COVERINGVINYL COMPOSITION BASEVINYL COMPOSITION TILEWELDED WIRE MESHWITHW/WWM.WT.WD.W/OWP.W.C.WEIGHTWATERPROOFINGWATER CLOSETWITHOUTWOODT.O.SL.T.O.S.V.W.C.V.C.T.VERT.V.C.B.V.I.F.TYP.TRT.VERIFY IN FIELDVERTICALTOP OF SLABTOP OF STEELTREATEDTYPICALSPECIFICATIONSPEC.THRUSUSP.STRUCT.TEL.THK.S.S.STL.STD.SQ.STRUCTURALTHROUGHSUSPENDEDTELEPHONETHICKSTANDARDSTAINLESS STEELSQUARESTEELRESIL.REQ'DSCHED.S.F.SIM.SHT.SEC.R.O.RM.REV.SIMILARSQUARE FOOTSCHEDULESECTIONSHEETROUGH OPENINGRESILIENTREQUIREDREVISIONROOMREINF.RAD.REF.R.A.QTY. Q.T.REINFORCINGRADIUSDUNKIN' BRANDSREFRIGERATORQUANTITYQUARRY TILEHUB DRAINH.D.ORIENTED STRAND O.S.B.BOARDFRPFIBERGLASS FURN.FURNITUREFT.FOOTREINFORCED PANELS UNLESS NOTED OTHERWISEU.N.O.DB-DEMO-TAGDB-NOTES-TITLEDRAWING INDEXT-1.0 TITLE SHEET/ ARCHITECTURAL DATA RESPONSIBILITYGN-2.0 MASTER FINISH SCHEDULEGN-2.1 MASTER FINISH SCHEDULE (CONT.)GN-2.2 MASTER FINISH SCHEDULE (CONT.)GN-2.3 MASTER FINISH SCHEDULE (CONT.)GN-3.0 NATIONAL ACCOUNTSA-8.0 INTERIOR ELEVATIONSA-9.0 INTERIOR DETAILSK-1.0 EQUIPMENT PLAN K-2.0 EQUIPMENT SCHEDULEE-2.0 ELECTRICAL POWER PLAN & ELEVATIONSE-3.0 TECHNOLOGY POS PLAN AND SCHEDULESE-3.1 TECHNOLOGY DETAILSP-1.0 PLUMBING PLAN; SCHEDULE; NOTESA-1.0 FLOOR PLAN; NOTES; DETAILSA-5.0 EXTERIOR ELEVATIONSA-2.0 REFLECTED CEILING PLAN; LIGHTING PLANGN-2.4 MASTER FINISH SCHEDULE (CONT.)A-5.1 EXTERIOR ELEVATIONSGN-2.5 MASTER FINISH SCHEDULE (CONT.)A-5.2 EXTERIOR DETAILSM-2.0 SANDWICH STATION HOOD DETAILA-8.1 INTERIOR ELEVATIONSE-2.1 ELECTRICAL BACKLINE ELEVATIONSP-3.0 3M WATER FILTRATION SYSTEMP-2.0 PLUMBING PLAN; SCHEDULE; NOTESA-2.1 NOTES; DETAILSJAMES D. SMITH ARCHITECTST-1.0S-1.0 SITE PLAN SCHEMATICAB-1.0 AS-BUILT FLOOR PLAND-1.0 DEMO PLANA-1A DIMENSION PLANA-3.0 FLOOR TILE PLAN JAMES D. SMITH ARCHITECTSS-1.0SITE NOTES:KEYED PLAN NOTES:DRIVE-THRU CONDUIT GENERAL NOTES:ALL CONDUIT SHALL BE PVCSURFACE OF VEHICLECONCRETE CURBCONDUIT w/ C PULLSTRING (TYP.)ORDERCANOPY/SPEAKERINDEPENDENTGROUND LOOPSFOR COMMUNICATIONSCONCRETE PADCONCRETE FOOTING SIZE &CONFIG. BY MANUFACTURERNOTE:REFER TO ELECTRICAL DRAWINGSFOR ALL LOOP & CONDUITREQUIREMENTS (TYP.)COORD ALL ELECTREQUIREMENTS w/MANUF PRIOR TOSTART OF WORKINDEPENDENTCONDUITS FORPOWER,DATA,VOICEAND SPARE. JAMES D. SMITH ARCHITECTSGN-2.0 GENERAL NOTES:1.NEW & REMODEL STORES HAVE THE OPTION OF A COOL OR WARM PALETTE FOR INTERIOR FINISHES2.CODE SUFFIX ( C ) = COOL PALETTE FINISHES3.CODE SUFFIX (W ) = WARM PALETTE OR REMODEL FINISHES WHEN KEEPING 2015 IMAGE FLOOR TILE4.CODE SUFFIX ( E ) = EXISTING5.FINISHES WITHOUT SUFFIX ARE UNIVERSAL TO THE COOL & WARM PALETTE6.REMODEL STORES KEEPING EXISTING 2015 IMAGE FLOOR TILE (TAN COLOR) SHALL ONLY USE THE WARM PALETTE JAMES D. SMITH ARCHITECTSGN-2.1 JAMES D. SMITH ARCHITECTSGN-2.2 JAMES D. SMITH ARCHITECTSGN-2.3 JAMES D. SMITH ARCHITECTSGN-2.4 JAMES D. SMITH ARCHITECTSGN-2.5 GENERAL NOTES:1.NEW & REMODEL STORES HAVE THE OPTION OF A COOL OR WARM PALETTE FOR INTERIOR FINISHES2.CODE SUFFIX ( C ) = COOL PALETTE FINISHES3.CODE SUFFIX (W ) = WARM PALETTE OR REMODEL FINISHES WHEN KEEPING 2015 IMAGE FLOOR TILE4.CODE SUFFIX ( E ) = EXISTING5.FINISHES WITHOUT SUFFIX ARE UNIVERSAL TO THE COOL & WARM PALETTE6.REMODEL STORES KEEPING EXISTING 2015 IMAGE FLOOR TILE (TAN COLOR) SHALL ONLY USE THE WARM PALETTE JAMES D. SMITH ARCHITECTSGN-3.0ACOUSTICAL CEILING TILES & GRIDS(ALL REGIONS)ARMSTRONG WORLD INDUSTRIESVENDOR CONTACT: MAUREEN CONEP: 703-389-2701E: MMCONE@ARMSTRONGCEILINGS.COMWWW.ARMSTRONG.COM/CEILINGSACOUSTICAL PANELSNEW ENGLAND SOUND PROOFINGP: 781-710-1261WWW.NEWENGLANDSOUNDPROOFING.COMALLEN INDUSTRIESVENDOR CONTACT: KEITH WHITLEYP: 919-410-1234E: KEITH.WHITLEY@ALLENINDUSTRIES.COMWWW.ALLENINDUSTRIES.COMATM SERVICESCARDTRONICSVENDOR CONTACT: TOM SPOONERP: 888-890-0600 X 14240E: TSPOONER@CARDTRONICS.COMWWW.CARDTRONICS.COMJARRETT SERVICESVENDOR CONTECT: ERIC JOHNSTONEP: 1-800-935-0107 X 204E: SALES@JARRETTFORCASH.COMWWW.JARRETTFORCASH.COMAWNING FABRICS AND VINYL:ARLON:VENDOR CONTACT: KEN HUGGINSP: 714-985-6310E: KHUGGINS@ARLON.COMWWW.ARLON.COMBOLLARD COVERSIDEAL SHIELDVENDOR CONTACT:1-800-731-1722DENNIS KNITTELPHONE: (313)551-2275DKNITTEL@IDEALSHIELD.COMBINDU ABRAHAMPHONE: (313)551-2283BABRAHAM@IDEALSHIELD.COMWWW.IDEALSHIELD.COMCOKE COOLERSCOKEVENDOR CONTACT: CARISSA BRUCEP: (800) 531-2238 EXT. 3716E: CABRUCE@COCA-COLA.COMCOMING SOON BANNERSLSM NOWP: 1-855-576-6669E: LSMNOW@WELDMEDIA.COMWWW.LSMNOW.NET/LOGIN.ASPXDRIVE THRU HEADSETS3MVENDOR CONTACT: BILL MUENKELP: 952-484-4875E: WEMUENKEL@MMM.COMWWW.3M.COM/FOODSERVICEHMEVENDOR CONTACT: PATRICK KELLYC: 858-535-6042E: PKELLY@HME.COMWWW.HME.COMDRIVE THRU TIMERSACRELECSCOTT MARENTAYP: 412-680-3909HMEVENDOR CONTACT: PATRICK KELLYC: 858-535-6042E: PKELLY@HME.COMWWW.HME.COMDRIVE THRU MENU BOARDSEVERBRITEVENDOR CONTACT: ANA DOMINGUEZP: 414-529-7107E: ADOMINGUEZ@EVERBRITE.COMWWW.EVERBRITE.COMVGSVENDOR CONTACT: ELIOT COHENC: 201-528-2122E: ECOHEN@VGS-INC.COMWWW.VGS-INC.COMHILTON DISPLAYSVENDOR CONTACT: PRESTON SMITHP: 865-320-6663E: PRESTONSMITH@HILTONDISPLAYS.COMWWW.HILTONDISPLAYS.COMPERSONA SIGNSVENDOR CONTACT: SUSAN KOELZERP: 605-882-2244 X 390E: SKOELZER@PERSONASIGNS.COMWWW.PERSONASIGNS.COMDRIVE THRU WINDOWSSALES: READY@READY-ACCESS.COMREADY ACCESSVENDOR CONTACT: KELLY MCGOLDRICKP: 630-876-7766 EXT. 113E: KELLY@READY-ACCESS.COMWWW.READY-ACCESS.COMQUIKSERVINSIDE SALES DEPT./ORDER ENTRYSALES@QUIKSERV.COMBRANDI LAIRDJESSICA WILLIAMSORBRANDI LAIRDPHONE: 713-849-5882TECHNICAL & PARTS SUPPORTBRIAN COBLENATIONAL ACCOUNTS MANAGERWADE ARNOLD11441 BRITTMORE PARK DRIVEHOUSTON, TX 77041PHONE: 713-849-5882FAX: 713-849-5708DRIVE THRU STENCILDGS RETAILVENDOR CONTACT: KAREN MCCUEE: KARENMCCUE@DGSRETAIL.COMP: 508-337-2990F: 508-337-5040WWW.DGSRETAIL.COMPAVEMENT STENCIL COMPANYP: 800-250-5547E: STENCILS@PAVEMENTSTENCIL.COMWWW.PAVEMENTSTENCIL.COMELECTRIC PANELS & BREAKERSVILLA LIGHTINGVENDOR CONTACT: DEANNA MCCLANAHANP: 1-800-325-0963E: DEANNA.MCCLANAHAN@VILLALIGHTING.COMWWW.VILLALIGHTING.COMEPOXY FLOORINGSTONHARDVENDOR CONTACT: SCOTT GARSTKAC: 413-237-9267P: 800-854-0310 OFFICE X-5158F: 856-321-7510E: SGARSTKA@STONHARD.COMWWW.STONHARD.COMEXTERIOR FIBER-CEMENT CLADDINGSYSTEMSNICHIHAPROJECT MANAGER: MATT STEPHENSONNATIONAL BRANDS MANAGERP: 770-789-8228EMAIL: DUNKINDONUTS@NICHIHA.COMEMAIL: MSTEPHENSON@NICHIHA.COMWWW.NICHIHA.COMEXTERIOR FIBER-CEMENT SIDING ANDPANELSJAMES HARDIEJEFF HARVEYP: 774-287-6278EMAIL: JEFFERY.HARVEY@JAMESHARDIE.COMWWW.JAMESHARDIE.COMWOODTONE PRODUCTSLAURENCE TAYLORWOODTONESALES REPRESENTATIVEP: 604-792-3680C: 604-798-2664EMAIL: LAURENCET@WOODTONE.COMTIM FOLSTERWOODTONEMANAGER, STRATEGIC ACCOUNTS8007 AITKEN ROADCHILLIWACK, BCP: 604-792-3680C: 604-845-9663EMAIL: TIMF@WOODTONE.COMWWW.WOODTONE.COMEXTERIOR INSULATED FIBERGLASSSYSTEMS (EIFS)DRYVIT SYSTEMSVENDOR CONTACT: ROBERT DAZELP: 734-276-0404E: BOB.DAZEL@DRYVIT.COMWWW.DRYVIT.COMEXTRUDED METAL CHANNEL @ EXTERIORAGIVENDOR CONTACT: RANDY KERRP: 800-877-3810 EXT.3248E: RKERR@AGI.NETWWW.AGI.NETHORACIO'S SHEET METALVENDOR CONTACT: MICHAEL TAVARESP: 508-985-9940F: 508-985-9965E: MIKE@HORACIOS.COMWWW.HORACIOS.COMTAMLYN - XTREME TRIMVENDOR CONTACT: IAN DANIELSP: 713-446-3075E: IDANIELS@TAMLYN.COMWWW.TAMLYN.COMFIBERGLASS REINFORCED PANELS (F.R.P.)CRANE - KEMLITE COMPOSITESVENDOR CONTACT: JEFF TOLLEP: 1-800-435-0080 OR 1-815-467-8600 OR1-815-274-9125 (DIRECT)C: 330-260-7627E: SALES@CRANECOMPOSITES.COMWWW.CRANECOMPOSITES.COMMARLITEVENDOR CONTACT: JAMIE MCEDWARDP: 800-377-1221 OR 603-924-9128F: 330-343-4668C: 330-260-7627E: JMCEDWARD@MARLITE.COMWWW.MARLITE.COMHVAC ROOFTOP UNITSTRANEVENDOR CONTACT: JONATHAN RALYSP: 781-305-1335F: 781-938-8912E: JONATHAN.RALYS@TRANE.COMWWW.TRANE.COMCARRIER CORPORATIONWWW.CARRIER.COMORDER MANAGER: CAROL VAVONESEOFFICE PHONE: 315-432-3254EMAIL: CAROL.J.VAVONESE@CARRIER.UTC.COMEMAIL: STRATEGICACCOUNTS2@CARRIER.UTC.COMACCOUNT GENERAL MANAGER: PAUL WITZCELL PHONE: 315-317-2481EMAIL: PAUL.WITZ@CARRIER.UTC.COMEMAIL: CAROL.J.VAVONESE@CARRIER.COMEMAIL: STRATEGICACCOUNTS2@CARRIER.COMEMAIL: PAUL.WITZ@CARRIER.COMEMAIL: DEREK.BIRDSALL@CARRIER.COMEMAIL: SCOTT.GILLISPIE@CARRIER.COMSERVICE CONTACT: DEREK BIRDSALLCELL PHONE: 315-726-2255EMAIL: DEREK.BIRDSALL@CARRIER.UTC.COMBUSINESS MANAGER: ROB ROHDEOFFICE PHONE: 315-432-3377EMAIL: SCOTT.GILLISPIE@CARRIER.UTC.COMRHEEM MANUFACTURING COMP.WWW.RHEEM.COMVENDOR CONTACT: LUKE BABEYP: 904-271-1126E: LUKE.BABEY@RHEEM.COMIN STORE MUSICFRANCHISEES TO SOURCE LOCALLYINTERIOR MENU BOARDS(STATIC)VGSVENDOR CONTACT: ELIOT COHENC: 201-528-2122E: ECOHEN@VGS-INC.COMWWW.VGS-INC.COM(DIGITAL)TEXAS DIGITALP: 877.504.4887 OPTION 2E: DUNKIN.TDS@NCR.COMKITCHEN HOODS/EXHAUST SYSTEMSCAPTIVE-AIRE SYSTEMSDAVID CRITTENDENP: 813-435-3388E: REG62@CAPTIVEAIRE.COMWWW.CAPTIVEAIR.COMKITCHEN SWING DOORELIASON CORPORATIONVENDOR CONTACT: JOE DUSENBERYP: (800) 828-3655F: (800) 828-3755E: DOORS@ELIASONCORP.COMLAMINATESFORMICAFOR LOCAL DISTRIBUTOR CALLKAREN KENNEY866-573-3512E: K.KENNEY@FORMICA.COMREP: JEAN MARIE REMICKO: (781) 235-4165C: (617) 217-8146JEANMARIE.BISSON@FORMICA.COMWWW.FORMICA.COMWILSONARTFOR ORDERS CALL800-433-3222 FOR A LOCAL DISTRIBUTOR.REPRESENTATIVE: AMY MORGENWECKP: 917.951.6524E: MORGENA@WILSONART.COM LIGHTING FIXTURES: INTERIOR & EXTERIORVILLA LIGHTINGVENDOR CONTACT: DEANNA MCCLANAHANP: 1-800-325-0963E: DEANNA.MCCLANAHAN@VILLALIGHTING.COMWWW.VILLALIGHTING.COMSPECIALTY LIGHTING GROUPVENDOR CONTACT: ANUSH KAZARIAN & LORRAINEGARIGLIANOP: 508-922-0786P: 860-767-0110 X 252E: ANUSH.KAZARIAN@SSLIGHTING.COMOR DUNKIN@SSLIGHTING.COMWWW.SSLIGHTING.COMMILLWORK/EQUIPMENT CONSOLIDATORQUALSERVVENDOR CONTACT: HEATH HAYDONP: 479-420-0298E: HHAYDON@QUALSERVCORP.COMWWW.QUALSERVCORP.COMHOCKENBERGSVENDOR CONTACT: TOM NEMMERSP: 913-526-9816E: TOMN@HOCKENBERGS.COMWWW.HOCKENBERGS.COMCONCEPT SERVICESVENDOR CONTACT: CHRIS PARNELLP: 512-343-3100E: CPARNELL@CONCEPTSERV.COMMILLWORK FABRICATORHOMELAND BUILDERSVENDOR CONTACT: BRIAN RIBEIROP: 508-677-0401 X 221E: BRIANR@HOMELANDBUILDERS.COMWWW.HOMELANDBUILDERS.COMHORACIO'S SHEET METALVENDOR CONTACT: MICHAEL TAVARESP: 508-985-9940F: 508-985-9965E: MIKE@HORACIOS.COMWWW.HORACIOS.COMNEXTGEN "D" DOOR HANDLES:TRIMCOVENDOR CONTACT:P: 323.262.4191 X 2E: CSR@TRIMCOHARDWARE.COMOLD STYLE "D" DOOR HANDLES:MICHAEL HEALY DESIGNSVENDOR CONTACT: NATASHA DURANDP: 1-800-995-0988E: CUSTOMERSERVICE@MICHAELHEALY.COMOUTSIDE FURNITURE: (LIGHT WEIGHT)KEY OFFICE INTERIORSACCOUNT MANAGER: DOUGLAS BUMSTEADP: 857-991-1376F: 617-439-0322E: DUNKINORDERS@KEYOFFICEINTERIORS.COMUMBRELLAS:EAST COAST UBRELLASVENDOR CONTACT: NICOLE MASONP: 910-462-2500 X 1223E: UMBRELLAS@EASTCOASTUMBRELLA.COMTUUCIVENDOR CONTACT: TAMMY LENHAMP: 305-637-6881E: TLENHAM@TUUCI.COMPATIOFLORIDA SEATINGVENDOR CONTACT: ERROL ROSARIOP: 727-540-9802E: ERROL@FLORIDASEATING.COMHJC (RAILING)VENDOR CONTACT: DAVID LIGHTFOOTP: 479-366-0642E: DAVID. LIGHTFOOT@HJCINC.COMPAINTSHERWIN WILLIAMSMARK T. WEINERNATIONAL ACCOUNT EXECUTIVE93 CHURCH STBARRINGTON RI 02806P: 800-474-3794O: 401-245-5176M: 617-438-1408EMAIL: MARK.T.WEINER@SHERWIN.COMP&G CLEANING AND SANITATION PROGRAMPROCTOR & GAMBLEVENDOR CONTACT: CARLA EVANSP: 513-983-9599E: EQCINCINNATI.IM@PG.COMWWW.PG.COMPIVOTING CANOPY AT DRIVE-THRUSPEAKER & CLEARANCE BAR, DT/ENTRANCE CANOPY & ORANGE BANDUNI-STRUCTURES, INC.VENDOR CONTACT: DANA MCDOUGALC: 678.974.1773E: D.MCDOUGAL@UNISTRUCTURES.COMWWW.UNISTRUCTURES.COMPOS (DD AND DD/BR)RADIANTVENDOR CONTACT: NANY COOPERP: 770-299-6881E: NANCY.COOPER@NCR.COMRADIANTORDERS.HSR@NCR.COMPRICE CONFIRMATION DISPLAY/SCANNERSRADIANTVENDOR CONTACT: NANY COOPERP: 770-299-6881E: NANCY.COOPER@NCR.COMRADIANTORDERS.HSR@NCR.COMRESTROOM FIXTURES AND ACCESSORIESNEWTON DISTRIBUTORSVENDOR CONTACT: PEDRO GRULLONP: 877-837-7745E: PEDRO@NEWTONDISTRIBUTING.COMWWW.NEWTONDISTRIBUTING.COMRESTROOM REMODELS15 HAMMATT ST.PO BOX 34IPSWICH, MA 01938PHONE: 617-500-2554FAX: 617-845-0350WWW.RESTROOMREMODELS.COMSALES@RESTROOMREMODELS.COMROOFING:DURO-LAST ROOFINGVENDOR CONTACT: JIM SCHRIBERP: 800-248-0280 X 2257E: JSCHRIBER@DURO-LAST.COM OR:CORPORATEACCOUNTS@DURO-LAST.COMSALES AREA, SERVICE/PREP. AREA FLOOR& WALL TILESDAL TILEVENDOR CONTACT: PAULA TOSTIP: 978-835-7793E: PAULA.TOSTI.@DALTILE.COMWWW.DALETILEPRODUCTS.COMCREATIVE MATERIALSVENDOR CONTACT:P: 800-207-2967 EXT. 3865 (DUNK)F: 518-452-9153E: DUNKINTILE@CREATIVEMATERIALSCORP.COMSECURITY PCI COMPLIANCE/ WIFICOMCASTDBI_COMCAST_ORDERING@COMCAST.NETORROSE VAZQUEZP: 508-314-7545ROSE_VAZQUEZ@COMCAST.COMSIGN MANUFACTURERAGIVENDOR CONTACT: RANDY KERRP:800-877-3810 EXT.3248E:RKERR@AGI.NETWWW.AGI.NETEVERBRITEVENDOR CONTACT: ANA DOMINGUEZP: 414-529-7107E: ADOMINGUEZ@EVERBRITE.COMWWW.EVERBRITE.COMPERSONA SIGNSVENDOR CONTACT: SUSAN KOELZERP: 605-882-2244 X 390E: SKOELZER@PERSONASIGNS.COMWWW.PERSONASIGNS.COMSIGN RESOURCEMAYWOOD, CAVENDOR CONTACT: KEN SIEGERTP:810-241-0272E:KSIEGERT@SIGNRESOURCE.COMSTORE GRAPHICSDGS RETAILVENDOR CONTACT: KAREN MCCUEE: KARENMCCUE@DGSRETAIL.COMP: 508-337-2990F: 508-337-5040WWW.DGSRETAIL.COMSTORE SURVEILLANCESECURITY SOURCE/MARCH SYSTEMSVENDOR CONTACT: SHAWNA REEVESP: 800-323-7612 X 109E: SREEVES@SECURITYSOURCE.COM/SECURITYSOURCEORDERS@SECURITYSOURCE.COMWWW.SECURITYCOURCE.COMSOLAR SHADERPHIFERP: 205-345-2120E: INFO@PHIFER.COMWWW.PHIFER.COMROLL-A-SHADEVENDOR CONTACT: RIC BERGP: 951-245-5077 X 113E: RIC@ROLLASHADE.COMWWW.RIC@ROLLASHADE.COMVENDOR CONTACT: KRISTEN FANNINP:951-245-5077 X 114C: 949 838 6436E:KRISTEN.FANNIN@ROLLASHADE.COMTANKLESS HOT WATER HEATERSRINNAIRINNAI AMERICA CORPORATION103 INTERNATIONAL DRIVEPEACHTREE CITY, GA 30269P: 866-383-0707TECHNICAL SUPPORT:DESK: 1-888-746-6247NATIONAL SALES MANAGER - CORPORATEACCOUNTSWALLY RICHARDSONDESK: 800-621-9419CELL: 678-848-1240EMAIL: WRICHARDSON@RINNAI.USNATIONAL SALES MANAGER - CORPORATEACCOUNTSWALLY RICHARDSONDESK: 800-621-9419CELL: 678-848-1240EMAIL: WRICHARDSON@RINNAI.USTHUNDER GROUPORDER CONTACT INFORMATION:THUNDER GROUP, INC.NDCPEMAIL: DUNKINSALES@THUNDERGROUP.COMP: 626-935-1605780 SOUTH NOGALES STREETCITY OF INDUSTRY, CA 91748WALK-IN BOXNORLAKEVENDOR CONTACT: DAVID VIOLAP: 715-386-2323E: DAVID@VIOLAGROUP.COMWWW.NORLAKE.COMKOLPAKVENDOR CONTACT: PHIL LETVINCHUKP: 508-320-3939E: PHILL@HATCHJENNINGS.COMWWW.KOLPAK.COMTHERMAL RITEVENDOR CONTACT: BECKY MURPHYP: 763-543-0136E: BECKY.MURPHY@THERMALRITE.COMWWW.THERMALRITE.COMWALL COVERINGS:APA GRAPHICSVENDOR CONTACT: MO KIMP: (404) 355-1355 X 206F: (404) 355-1359E: DUNKINORDERS@APACOLORGRAPHICS.COMWWW.APACOLORGRAPHICS.COMWATER QUALITY REQUIREMENTS:WATER BOOSTER SYSTEMMCCANN'S ENGINEERINGVENDOR CONTACT: ELEANOR HINSONP: 818-637-7219E: ELEANOR.HINSON@MANITOWOC.COMWWW.MCCANNSENG.COMWATER QUALITY:WATER FILTRATION SYSTEM3M FILTRATIONORDERS & WATER TEST KITSLETICIA GUZMANP:800-333-2866 (CUNO)F: 630-836-1793E: AWS@AWSDISTRIBUTING.COM3M SALES NATIONAL ACCOUNT REP:GREG HARRINGTONNATIONAL ACCOUNT SALES MANAGERPHONE: 732-644-8990GJHARRINGTON@MMM.COM3M FIELD OPERATIONSGREG HARRINGTONPHONE: 732-644-8990GJHARRINGTON@MMM.COMWWW.SOLUTIONS.3M.COM/WPS/PORTAL/3M/EN_US/3M-PURIFICATION-INC/3MPI-US/WATER FILTRATION SYSTEMPENTAIR (EVERPURE)ORDERS & WATER TEST KITS1800-842-6193DUNKINH2OKIT@PENTAIR.COMJOHN HINERSTRATEGIC ACCOUNT MANAGERPENTAIR FILTRATION SOLUTIONSPENTAIR WATER QUALITY SYSTEMSP: 201-417-5564E: JOHN.HINER@PENTAIR.COMNATIONAL ACCOUNTS SOURCE INFONOTE:1.FOR COMPLETE NATIONAL ACCOUNTS SOURCE INFORMATION, REFER TO THE DUNKIN' BRANDS NATIONAL ACCOUNT WEB SITE (http://extranet.dunkinbrands.com). TO OBTAIN A USER NAME AND PASSWORD PLEASE CONSULT YOUR LOCAL CONSTRUCTION MANAGER.2.CONTRACTOR TO IDENTIFY ONESELF AS WORKING WITH DUNKIN' BRANDS WHEN ORDERING FROM NATIONAL ACCOUNTS. JAMES D. SMITH ARCHITECTSAB-1.0ICE MACH.DISPLAYRACKDISPLAYRACK2'-7"HAND-OFFSANDWICH STATION 10'-0"" D/T COFFEE13'-0"COUNTER52" CNTR.HandSinkEXIST POT SINKORDERTAKER 4'-4"D/T POSPOS TRASHEMTRYWater FiltrationSystemCOOLERTABLEEXIST. ELEC. SERVICE5'-8"POS STATIONPOSPOSCOOLATTA8'-6"COUNTER51" CNTR.BEV.REF.(By Pepsi)ACCESSIBLERESTROOMACCESSIBLERESTROOMOFFICE4'-0"CONDIMENTFREEZERHandSink3'-8"CNTR.16"16" D-1.0JAMES D. SMITHARCHITECTS1. DEMO EXISTING CEILING GRID/ TILES IN HALL, SALES/SERVING AREAS. NEW CEILING PER REFLECTED CEILING PLAN SHEET A-2.0. 2. REPLACE EXISTING LIGHT FIXTURES IN SALES AREA/SERVING AREAS WITH NEW LED LIGHT FIXTURES. SEE CEILING PLAN A-2.0. 3. WALK-IN FREEZER AND REFRIGERATOR TO REMAIN POWERED AND FUNCTIONAL THROUGHOUT DURATION OF PROJECT. 4. GC TO OBTAIN ALL CONSTRUCTION MATERIALS IN ADVANCE AND STORE WITHIN ONSITE STORAGE UNIT. MATERIALS WITHIN STORAGE UNIT ARE TO BE PACKED AND STAGED ACCORDING TO SEQUENCE OF PROJECT TO FACILITATE LOADING JOB. 5. EQUIPMENT SUPPLIER TO PLACE ALL NEW EQUIPMENT. 6. GENERAL CONTRACTOR TO PLACE ALL EXISTING EQUIPMENT AS INDICATED ON EQUIPMENT PLAN. 7. GENERAL CONTRACTOR TO MAKE ALL MECHANICAL, PLUMBING AND ELECTRICAL CONNECTIONS FOR ALL THE EQUIPMENT AS INDICATED ON EQUIPMENT PLAN. 8. GENERAL CONTRACTOR TO DISCONNECT ALL EXISTING EQUIPMENT AS REQUIRED PER SCOPE OF OUTLINED WORK, SHUTDOWNS MAY BE STAGED, UNLESS MAJOR ELECTRICAL OR PLUMBING WORK IS REQUIRED THAT COULD CAUSE DAMAGE TO EQUIPMENT THAT IS CONNECTED. 9. REMOVE EXISTING PYLON SIGN. NEW SIGN FACE BY SIGN VENDOR. SEE SHEET A-5.2. 10. GC TO COORDINATE PERMIT, APPROVALS, AND LOCATION OF DUMPSTER AND STORAGE UNIT PRIOR TO STORE CLOSING. 11. BACK OF HOUSE TO BE THOROUGHLY CLEANED INCLUDING ALL WALLS, FLOORS, RACKS, ETC. 12. CONSULT OWNER TO REPLACE TOILET FIXTURES. SEE PLUMBING PLAN P-1 FOR RESTROOM EQUIPMENT SCHEDULE. 13. REMOVE ALL EXISTING BUILDING SIGNS. SEE EXTERIOR ELEVATION SHEET FOR NEW SIGNS. SIGN VENDOR TO APPLY FOR PERMITS. 14. EXISTING DRIVE-THRU MENUBOARD TO BE REMOVED/REPLACED W/ NEW DIGITAL MENU BOARD; SEE DETAIL ON SHEET A-5.2. 15. EXISTING GYP. BOARD CEILING IN TOILETS TO REMAIN. PAINT CEILING. NEW LED LIGHT FIXTURES. NEW MOTION SENSORS. SEE CEILING PLAN A-2.0. 16. EXISTING FLOOR TILE IN SALES/SERVICE/HALL/TOILET AREAS TO REMIAN. G.C. TO REPLACE ANY BROKEN/DAMAGED TILES AS NEEDED. 17. ADD NEW VEHICLE CLEARANCE BAR. SEE EXTERIOR DETAIL SHEET A-5.2. 18. DEMO ALL EXISTING FRONT LINE/BACK LINE MILLWORK. NEW MILLWORK PER FLOOR PLAN. NEW SANDWICH STATION & HOOD. SEE SHEETS A-2.0/M-2.0. 19. REMOVE ALL EXISTING TABLES/CHAIRS/FIXED TABLE BASES. REPAIR/REPLACE AFFECTED FLOOR TILES AS NEEDED. ALL NEW SEATING PER FLOOR PLAN. 20. REMOVE EXISTING WALL FINISHES THROUGHOUT THE SALES/SERVING/RESTROOM AREAS. ALL NEW WALL FINISHES. SEE INTERIOR ELEVATIONS A-8.0/8.1. 21. REPAIR ANY DAMAGED ASPHALT. RE-SEAL/RE-STRIP PARKING AS REQUIRED. UPDATE SITE LIGHTING TO LED. CONSULT OWNER. DEMOLITION NOTES 22. ALL EXISTING CAMERAS/EMERGENCY FIXTURES TO REMAIN. DISCONNECT AS REQUIRED. RELOCATE CAMERAS & RE-WIRE SPEAKERS AS REQUIRED. 23. PORTION OF EXISTING BACKLINE SOFFIT TO REMAIN. NEW SOFFIT LIGHT FIXTURES PER CEILING PLAN A-2.0. 24. NOT USED 25. G.C. TO REPLACE/REPAIR ANY DAMAGED STORE FRONT, WOOD SIDING, GUTTERS ETC. 26. REPLACE/REPAIR ANY DAMAGED DOORS. 27. ALL SITE LIGHTS & SIGN PLOES TO BE RE-PAINTED. REPLACE/REPAIR NON-WORKING LIGHT FIXTURES. 28. REPLACE/REPAIR ANY DAMAGED STORE FRONT FRAMES/PANELS. 29. G.C. TO PROVIDE NEW CONCRETE PAD AT DRIVE-THRU MENU BOARD. 30. ALL SALES AREA CEILING FIXTURES INCLUDING SPEAKERS, DIFFUSERS ETC. TO BE PAINTED BLACK TO MATCH NEW CEILING TILE/GRID. ICE MACH.Water FiltrationSystemTABLEEXIST. ELEC. SERVICE Hand Sink JAMES D. SMITH ARCHITECTSA-1.0Water FiltrationSystemHandSink05'10'442 SF Non-Retail1233 SF Retail1675 SF Total84 SF Interior Walk In12 SEATS= VIDEO DISPLAY UNIT= PRINTER= PRINTER UNDERCOUNTER= ELECTRICAL DUPLEX OUTLET= SURFACE MOUNTED PLUMBING= OPTIONAL OSB VDU= RECESSED TECHNOLOGY= FLOOR SINK= ELECTRICAL SINGLE OUTLET= D/T MONITORBEV. REF.(LOW HT.,BY COKE)5 WIDE BAKERY CASEPOSOPTIONALPOS5'-0" POSEXPEDITOR VDUPOS OPTIONAL COIN DISPENSERBUMP BAR(VERTICAL ONMULLION/WALL)O-TUCR42" CASH CARTGO21 MONITOR FOR D/TCAMERAMONITOR FOR D/TTIMERVDUSANDWICH STATIONDUKE 94 (7'-10")1 VDU, 1 PRINTER6336HOOD ABOVEICE BINCUPSBEVERAGE VDU3'-6"CUPSCUPSLID HOLDERSPOONHOLDER2 DBL. WARMERSSHELF FOR 2PRINTERS & 1BUMP BARUCRESPRESSO6'-3" TAPS ONLY KNEEWALL8 HEAD TAP SYSTEM10"3'-6 1/2"BUMP BAR FOR EXPEDITOR VDUOTGO PRINTER (UNDERCOUNTER)OPTIONAL OSB VDU(6'-8" AFF TO BOTTOM OF UNIT)6'-0" ORDERPICK-UPOMOPICK-UP(W/ SHELVING)3'-0" ORDERPICK-UP (ext.)ICE BINCUPSBEVERAGE VDU 3'-6"CUPS CUPSSHELF FOR 2PRINTERS & 1BUMP BARLID HOLDERESPRESSO UCR ISLANDOASISUCRHOTCHOCOLATE3-TIERMERCHANDISING3-TIERMERCHANDISINGKIOSKADAClearanceCONDIMENTS/ TRASH48" W. TABLE48" W. TABLEICBSYRUP RACKPOWDER RACKLID HOLDERISLANDOASIS BAKERYCASEDBL. LIDHOLDERTrashHANDSINK LID HOLDER SYRUP RACK POWDER RACK CONDIMENTS/ TRASHLID HOLDER 2 DBL. WARMERS TRASHCOMPOSTDBL. LIDHOLDER13. NEW MANDATORY WATER FILTRATION SYSTEM MOUNTED ON WALL. CONNECT EQUIPMENTS AS SHOWN ON SHEET P-3.0. OPTIONAL BOOSTERPUMP IS REQUIRED IF EXISTING WATER PRESSURE IS BELOW 65 PSI. EXACT LOCATION OF WATER FILTRATION SYSTEM TO BE DETERMINED BY GC/OWNER.1. TYPICAL SUBSTRATES FOR NEW INTERIOR WALLS SHALL BE AS FOLLOWS:PREP/ KITCHEN AND STORAGE AREAS: 0'-0" TO 3'-0" - 58" DUROCK CEMENT BOARD, 3'-0" AND ABOVE - 58" ORIENTED STRAND BOARD (OSB)SERVICE AREA:58" MIN. ORIENTED STRAND BOARD (OSB), 58" DUROCK CEMENT BOARD BEHIND PORCELAIN/ CERAMIC TILES.SALES AND SEATING AREAS:58" GYPSUM BOARD, 58" DUROCK CEMENT BOARD BEHIND CERAMIC TILES, 58" ORIENTED STRAND BOARD @ DECORATIVE PLAM "WOOD" WALLS.RESTROOMS:58" DUROCK CEMENT BOARD - GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING AS REQUIRED THROUGHOUT: IN RESTROOMS FOR GRAB BARS, LAVATORIES, HANDDRIERS, MIRRORS, PAPER TOWEL DISPENSERS, SOAP DISPENSERS, AND OTHER ACCESSORIES UNLESS OTHERWISE NOTED; IN SERVICE AREA FOR:VDU, WALL SHELVES, ETC.2. DIMENSIONS SHOWN ARE TO THE FACE OF FINISH.3. REFER TO EQUIPMENT "K" SHEETS FOR INFORMATION REGARDING THE EQUIPMENT AND EQUIPMENT LAYOUT.4. REFER TO NEXT GENERATION PROTOTYPE SET FOR DOOR SCHEDULE AND DOOR & FRAME TYPES.5. THESE PLANS ARE CONSIDERED MINIMUM DUNKIN' BRANDS CORPORATE DESIGN REQUIREMENTS. ANY STRUCTURAL DESIGN, REQUIRED ADACOMPLIANCE AND GENERAL BUILDING REQUIREMENTS MUST BE EVALUATED AND CERTIFIED BY AN ARCHITECT REGISTERED IN THE STATE WHERETHIS STRUCTURE IS TO BE BUILT.6. THE FOLLOWING SITE ELEMENTS SHALL BE UPGRADED TO THE NEXT GENERATION IMAGE AS APPLICABLE: - HEIGHT RESTRICTION BAR - MENU BOARD/ ORDER CANOPY - DIRECTIONAL SIGNS - PYLON/ MONUMENT SIGN - NEW BOLLARD AT DRIVE-THRU MENU BOARD. (SEE BOLLARD DETAIL ON SHEET A-5.2)7. PROVIDE FIRE EXTINGUISHERS, TYPE ABC, WALL HUNG, TOP @ 5'-0" A.F.F. (BY G.C.). - NUMBER AND LOCATION AS DETERMINED BY LOCAL CODE8. LAYOUT NOTES:A. ARCHITECT & G.C. TO ENSURE 40" MINIMUM CLEAR ACCESS INTO AND THROUGHOUT THE STORE FOR DELIVERY OF LARGE EQUIPMENTITEMS.B. FRANCHISEE'S ARCHITECT TO VERIFY COMPLIANCE WITH APPLICABLE ADA AND CODE REQUIREMENTS FOR RESTROOM(S) ANDENTRANCE(S).C. FRANCHISEE'S ARCHITECT SHALL DETERMINE MENUBOARD SIZE AND CONFIGURATION BASED ON FIELD CONDITIONS AND MENU CHOICES.10. INDOOR AIR QUALITY MANAGEMENT REQUIREMENTS:A. DURING CONSTRUCTION THE USE OF SMOKING/TOBACCO PRODUCTS INSIDE THE BUILDING IS PROHIBITED.B. CONTRACTOR AND SUBCONTRACTORS SHOULD MAKE EVERY EFFORT TO MAINTAIN CLEAN WORK AREAS.C. MATERIALS THAT ARE ABSORPTIVE SHOULD BE ELEVATED FROM THE GROUND AND COVERED WITH VISQUEEN WHILE STORED ON SITE.D. IF THE HVAC SYSTEMS WILL BE USED DURING CONSTRUCTION ACTIVITIES, TEMPORARY FILTRATION (MERV 8) SHOULD BE USED ON ALLRETURN AIR INTAKES, AND THE FILTERS INSIDE THE UNIT SHOULD BE REPLACED PRIOR TO BUILDING TURN OVER.E. ALL INDOOR AIR QUALITY MANAGEMENT POLICIES OUTLINED ABOVE ARE PHOTOGRAPHED AT 25%, 50%, AND 75% PROJECT COMPLETION TOCONFIRM MEASURES WERE FOLLOWED.11. CONSTRUCTION WASTE RECYCLING REQUIREMENTS:A. ALL CONSTRUCTION-RELATED RECYCLABLE WASTE SHOULD BE RECYCLED/REUSED OR OTHERWISE DIVERTED FROM LANDFILL WHENEVERPOSSIBLE.B. AT MINIMUM ALL CONCRETE, METAL, AND PLASTIC THAT MEETS LOCAL RECYCLING STANDARDS SHOULD BE RECYCLED.C. WHERE LOCAL MUNICIPALITIES OR VENDORS OFFER COMMINGLED RECYCLING OPPORTUNITIES TO HELP ACHIEVE OVER 50%CONSTRUCTION WASTE DIVERSION RATE FROM LANDFILL, FRANCHISEE SHOULD PURSUE.12. EXISTING EMERGENCY FIXTURES, SECURITY CAMERAS TO REMAIN.GENERAL NOTES14. G.C. TO PROVIDE NEW BOLLARDS IN FRONT OF STORE. INSTALL BOLLARDS 5'-0" O.C.. SEE SITE PLAN (S-1.0) AND BOLLARD DETAIL ON SHEET A-5.2.1A-11A-112312311131825251216161697455242424242427202020202020201923172288888151.CASEWORK BY OTHERS.2.EXISTING BUMP-OUT DRIVE-THRU WINDOW.3.EXISTING ROOF LADDER.4.EXISTING JANITOR'S SINK - PROVIDE DEDICATED WATERSUPPLY FOR P&G DISPENSER (SEE NATIONAL ACCOUNTS).P&G EQUIPMENT INSTALLED BY VENDOR.5.SURFACE MOUNTED HAND DRYER W/ DBI BRANDING ANDSUSTAINABILITY MESSAGE; REFER TO NATIONALACCOUNTS.6.P.O.S. OUTLET BOX (48" A.F.F.) WITH 12" CONDUIT W/PULLSTRING TO CEILING.7.EXISTING TANK TYPE HOT WATER HEATER.8.EXISTING BOLLARD, REFER TO NATIONAL ACCOUNTS FORNEW BOLLARD COVER INFORMATION.9.EXISTING 3 COMPARTMENT SINK W/ 2 INTEGRATED DRAINBOARDS - PROVIDE DEDICATED WATER SUPPLY FOR P&GDISPENSER (SEE NATIONAL ACCOUNTS). P&G EQUIPMENTINSTALLED BY VENDOR.10.EXISTING FROST PROOF HOSE BIB.11.2" X 2" STAINLESS STEEL CORNER GUARDS, FULL LENGTHOF CORNER UP TO CEILING (TYPICAL THROUGHOUT BACKOF HOUSE).12.EXISTING ELECTRICAL PANELS.13.HAND SINKS ARE REQUIRED WITHIN A 25 FT. RADIUS OF ALLWORK STATIONS IN SERVICE AND PREP. AREAS (OR PERLOCAL CODE IF MORE STRINGENT).14.SWING GATE BY MILLWORK VENDOR.15.EXISTING ELECTRICAL METER.16.PROVIDE DIRECT LINE W/ TEMPERATURE REGULATORVALVE FROM HWH TO ALL HAND WASHING SINKS.17.LINE OF ORANGE METAL CANOPY.18.G.C. TO PROVIDE ANCHOR BOLTS FOR SLAB MOUNTED SAFEIN OFFICE- REFER TO SPECIFICATIONS TO BE PROVIDED BYFRANCHISEE.19.EXISTING WATER FILTRATION SYSTEM (BRANCH OFF MAINLINE) FOR COFFEE BREWING EQUIPMENT, BEVERAGEMACHINES, ETC. AND BOOSTER PUMP (OPTIONAL).20.WINDOW SHADE; SEE CONSTRUCTION SPECIFICATIONS ONGN-1.5 AND NATIONAL ACCOUNTS SUPPLIER ON THEEXTRANET.21.CORE DRILL. REFER TO NEXT GENERATION PROTOTYPE SETFOR ADDITIONAL INFO.22.LINE OF ORANGE METAL CANOPY OVER DRIVE THRUWINDOW.23.MILLWORK SUPPLIER SHALL PROVIDE ACCESS FORUTILITIES & CLEANING AT ALL FRONT LINE MILLWORK.24.PROVIDE CLEAR ANODIZED ALUM EDGE TRIM (SCHLUTER"JOLLY") FOR FULL HEIGHT OF WALL @ EXTERNAL CORNERS& ALL LOCATIONS WHERE TILE ENDS.25.EXISTING WALL FINISHES IN OFFICE AND PREP./STORAGEAREAS TO REMAIN, TYP.26.NOT USED27.ACCENT PANEL. SEE EXTERIOR ELEVATIONS.28."PLAN TUBE" MOUNTED ON WALL. PLAN NOTES: JAMES D. SMITH ARCHITECTSA-1.AWater FiltrationSystemHandSinkBEV. REF.(LOW HT.,BY COKE)5 WIDE BAKERY CASEPOSOPTIONALPOS5'-0" POSEXPEDITOR VDUPOS OPTIONAL COIN DISPENSERBUMP BAR(VERTICAL ONMULLION/WALL)O-TUCR42" CASH CARTGO21 MONITOR FOR D/TCAMERAMONITOR FOR D/TTIMERVDUSANDWICH STATIONDUKE 94 (7'-10")1 VDU, 1 PRINTER6336HOOD ABOVEICE BINCUPSBEVERAGE VDUCUPSCUPSLID HOLDER SPOON HOLDER2 DBL. WARMERSSHELF FOR 2PRINTERS & 1BUMP BARUCRESPRESSO6'-3" TAPS ONLY KNEEWALL8 HEAD TAP SYSTEM10"3'-6 1/2"BUMP BAR FOR EXPEDITOR VDUOTGO PRINTER (UNDERCOUNTER)OPTIONAL OSB VDU(6'-8" AFF TO BOTTOM OF UNIT)6'-0" ORDERPICK-UPOMOPICK-UP(W/ SHELVING)3'-0" ORDERPICK-UP (ext.)ICE BINCUPSBEVERAGE VDU CUPS CUPSSHELF FOR 2PRINTERS & 1BUMP BARLID HOLDERESPRESSO UCR ISLANDOASISUCRHOTCHOCOLATE 3-TIERMERCHANDISING3-TIERMERCHANDISINGKIOSKADAClearanceCONDIMENTS/ TRASH48" W. TABLE48" W. TABLEICBSYRUP RACKPOWDER RACKLID HOLDERISLANDOASIS BAKERYCASEDBL. LIDHOLDERTrashHANDSINK LID HOLDER SYRUP RACK POWDER RACK CONDIMENTS/ TRASHLID HOLDER 2 DBL. WARMERS TRASHCOMPOSTDBL. LIDHOLDER JAMES D. SMITH ARCHITECTSA-2.01. EXISTING GYPSUM WALL BOARD CEILING. PAINT CEILING2. EXISTING BACKLINE SOFFIT. REFER TO INTERIOR ELEV. FOR PAINT FINISH.3. ARCHITECT TO ENSURE THAT ADEQUATE DISTANCE IS MAINTAINED BETWEEN 4. NEW EXHAUST HOOD FOR SANDWICH STATION WITH ROOF FANREQUIRED PER DBI STANDARDS.6. NEW DIGITAL MENU BOARDS ON NEW BACKLINE SOFFIT. CENTER WITH 7. 24"x24" ACCESS PANEL 8. 50" WIDE "LROD" PANEL ARTWORK - SEE INTERIOR ELEVATIONS9. PORTION OF EXISTING SOFFIT TO REMAIN. GYPSUM BOARD CEILING.10. CUSTOM LIGHT BAR, MOUNTED @8'-0" A.F.F., SEE DETAIL #1/ SHEETA-2.1.12. NOT USED14. PORTION OF EXISTING SOFFIT TO REMAIN. FRONTLINE SOFFIT TO15. NOT USED18. CEILING MOUNT SPEAKERS. PAINT WHITE COLOR IN RESTROOM 17. GC TO PAINT EXISTING SUPPLY DIFFUSER CEILING FINISH COLOR.20. EXISTING EXIT SIGNS TO REMAIN.19. NOT USEDGENERAL NOTES:1.ALL INTERIOR & EXTERIOR LIGHTING TO BE LED.2.EFFECTIVE LIGHTING CONTROLS STANDARD THROUGHOUT. OCCUPANCY SENSORS TO BE USED IN SPACES NOTACTIVELY USED THROUGHOUT THE DAY (RESTROOMS, OFFICE, CONFERENCE ROOMS AND ETC.).INTEGRATE OCCUPANCY SENSORS IN SPACES NOT ACTIVELY USED THROUGHOUT THE DAY INCLUDING:RESTROOMS, OFFICE, WALK-IN BOX, CONFERENCE ROOMS & CLOSETS.3.REFER TO MASTER FINISH SCHEDULE FOR CEILING FINISHES.4.ACT CEILING IN SEATING/ QUEUING/ VESTIBULE TO BE CT-02 ("BLACK" CEILING TILE). ALL DEVICES (DIFFUSERS,RETURNS, SMOKE DETECTORS, ETC.) TO MATCH CEILING.5.LAYOUT NOTES:A.PROVIDE EMERGENCY LIGHTS & SMOKE DETECTORS AS REQUIRED BY LOCAL GOVERNING CODE.B.ADD THE RH REMOTE WEATHER PROOF EMERGENCY HEAD (PRODUCT #Z1PB) TO THE EXTERIOR EGRESSDOORS IF REQUIRED BY CODE.C.HOOD OVER SANDWICH STATION IS RECOMMENDED BUT NOT REQUIRED. ARCHITECT / ENGINEER MUSTREVIEW LOCAL CODES TO DETERMINE WHETHER A HOOD IS REQUIRED. IF A HOOD IS NOT USED IT ISREQUIRED THAT AN EXHAUST GRILL BE PLACED IN THE CEILING ABOVE THE SANDWICH STATION. IF NOEXHAUST IS PROVIDED AT THE SANDWICH STATION THE FRP PANELS AND / OR DIGITAL MENU BOARDS COULDBE AFFECTED BY THE HEAT FROM THE SANDWICH STATION.6.MUSIC SYSTEM NOTES: THE MUSIC SYSTEM IS A REQUIREMENT OF THE BRAND. ARCHITECTS TO FOLLOW ALLGUIDELINES LISTED BELOW.A.MUSIC SYSTEM IS REQUIRED IN ALL NEW AND REMODEL STORES. ALL CEILING SPEAKERS TO BE FLUSHMOUNTED @ GYP. BOARD CLG. & ACT CLG. ALL INTERIOR SPEAKERS TO MATCH SURFACE IT IS MOUNTED ON.ALL EXTERIOR SPEAKERS TO BE BLACK, WITH EXTERIOR GRADE CONSTRUCTION.B.ONE SPEAKER IN EACH RESTROOM- FLUSH MOUNT.C.A MINIMUM OF TWO SPEAKERS IN THE SEATING AREA NO SPEAKERS IN THE SERVICE AREA.D.A MINIMUM OF TWO SPEAKERS AT EXTERIOR SEATING AREAS WHERE APPLICABLE.E.SPEAKER AT EXTERIOR OF BUILDING ADJACENT TO ENTRY.F.PROVIDE AND INSTALL SEPARATE VOLUME CONTROLS FOR EACH AREA (RESTROOMS, SEATING AREA,EXTERIOR)G.HARDWARE TO BE INSTALLED IN THE OFFICE. FIELD VERIFY AND COORDINATE WITH FRANCHISE FOR THEEXACT LOCATION OF THE UNIT AND VOLUME CONTROLS. PLAN NOTES:AND BLACK IN SALES AREA. VESTIBULE SAME COLOR CEILING.POS STATION AT FRONT LINE. PROVIDE ELECTRICAL CONNECTION AS REQUIRED.DIGITAL MENU BOARDS AND OTHER OBSTRUCTIONS SUCH AS LIGHTS, SPRINKLER CAUSE UNWANTED GLARE. HEAT FROM TOASTER WILL LEAD TO SCREEN FAILURE. HEADS, CAMERAS, AND TOASTER/OVEN. 36" MIN. DISTANCE BETWEEN DMBS AND EACH OBSTRUCTION IS PREFERRED. LIGHTS PLACED TOO CLOSE TO DMB MAY13. G.C. TO PROVIDE BLOCKING AND TO INSTALL CEILING MOUNT POLE (PROVIDED BY VENDOR) FOR ORDER STATUS BOARD.11. GC TO INSTALL OCCUPANT SENSOR IN RESTROOMS/OFFICE AT 42" A.F.F. TIE EXISTING EXHAUST FAN AND LIGHT TO SENSOR.CEILING LEGEND:R1LED RECESSEDSOFFIT LIGHT FIXTUREWSCX-2GOOSE NECK LIGHTFIXTURE(TYP.)GYPSUM BOARDCEILING2"X4" CEILINGGRID SYSTEMCEILING MOUNTED SPEAKERWALL MTD EMERG LIGHT/EXITSIGN COMBOEXISTING WALL MTD EMERGLIGHT TO REMAIN.ORANGE LIGHTBAR FIXTUREWALL-MTD OCCUPANCYSENSOREWS-1WALL PACKR4EX12"X2" CEILINGGRID SYSTEMAWALL WASH FIXTURE2x2 LAY-IN LED TROFFER LIGHTFIXTURER22x2 LAY-IN LED LIGHT FIXTUREW/ LENSR6LED-2EXTERIOR RECESSEDLIGHT FIXTUREEXTERIOR LED TAPE LIGHTLED-12/ LED-13/ LED-14TRACK LIGHTCCEILING EXHAUSTREGISTER24"X48" SUPPLY AIRDIFFUSER24"X48"RETURN AIR DIFFUSER12"X12"SUPPLY AIRDIFFUSEREBU-W(IN BOTH TOILETS & OFFICE)MOCEX2WALL MTD EXIT SIGN16. EXISTING EMERGENCY LIGHT TO REMAIN.18181717MOC11MOC11EBU-W16EBU-W16EXISTING EMERGENCY LIGHTHEADS TO REMAIN V.I.F.16REPLACE EXISTINGLIGHT FIXTURE WITHNEW LED LIGHTREPLACE EXISTINGLIGHT FIXTURE WITHNEW LED LIGHTEXISTING SOFFIT. PAINTEX2 20EBU-W16EXISTING EMERGENCY LIGHTHEADS TO REMAIN V.I.F.14 ALIGN WITH MILLWORK BELOW.1013EXISTINGSOFFIT LINE792563114EBU-W8LED-2LED-2LED-2REMOVE EXISTING LIGHT FIXTURES.REPLACE WITH NEW LED LIGHTS17118NEW CEILING SPEAKER.CONNECT TO EXISTING CIRCUIT1818VMOC111815LENGTH OF LED-13WSCX-2EXISTING SOFFIT LINE.REPLACE EXISTINGLIGHT FIXTURE WITHNEW LED LIGHT1EXISTING SOFFIT. PAINT5. 4- 32" (DEFAULT SIZE) DIAGONAL BOARDS IS 118" L (9'-10") AND 19"H (1'-7") 1. ALL INTERIOR & EXTERIOR LIGHTING TO BE LED (INCLUDING IN THE WALK-IN BOX).2. EFFECTIVE LIGHTING CONTROLS STANDARD THROUGHOUT. OCCUPANCY SENSORSTO BE USED IN SPACES NOT ACTIVELY USED THROUGHOUT THE DAY (RESTROOMS,OFFICE, CONFERENCE ROOMS AND ETC..).INTEGRATE OCCUPANCY SENSORS IN SPACES NOT ACTIVELY USED THROUGHOUTTHE DAY INCLUDING: RESTROOMS, OFFICE, WALK-IN BOX, CONFERENCE ROOMS &CLOSETS.3. REFER TO MASTER FINISH SCHEDULE FOR CEILING FINISHES.4. OPEN CEILING IN SALES & SEATING AREA TO BE ALTERNATIVE OPTION.5. ALL DEVICES (DIFFUSERS, RETURNS, SMOKE DETECTORS, ETC.) TO MATCH CEILING.WHEN OPEN CEILING IS USED ALL PIPES AND DUCTS AND ALL OTHER ITEMS THATARE ON CEILING TO BE PAINTED TO MATCH CEILING.6. LAYOUT NOTES:A. PROVIDE EMERGENCY LIGHTS & SMOKE DETECTORS AS REQUIRED BY LOCALGOVERNING CODE.B. ADD THE RH REMOTE WEATHER PROOF EMERGENCY HEAD (PRODUCT #Z1PB)TO THE EXTERIOR EGRESS DOORS IF REQUIRED BY CODE.C. HOOD OVER SANDWICH STATION IS RECOMMENDED BUT NOT REQUIRED.ARCHITECT / ENGINEER MUST REVIEW LOCAL CODES TO DETERMINEWHETHER A HOOD IS REQUIRED. IF A HOOD IS NOT USED IT IS REQUIRED THATAN EXHAUST GRILL BE PLACED IN THE CEILING ABOVE THE SANDWICHSTATION. IF NO EXHAUST IS PROVIDED AT THE SANDWICH STATION THE FRPPANELS AND / OR DIGITAL MENU BOARDS COULD BE AFFECTED BY THE HEATFROM THE SANDWICH STATION.GENERAL NOTESJAMES D. SMITH ARCHITECTSA-2.1NOTE:FRANCHISEE AND GENERAL CONTRACTORTO COORDINATE LIGHTING VENDOR DECISION.VILLA or SPECIALTY LIGHTING JAMES D. SMITH ARCHITECTSA-3.0SERVICE SIDESALES SIDE2134AA-3.0AA-3.0AA-3.0CA-3.0AA-3.0AA-3.0AA-3.0AA-3.0AA-3.02314FT-01 (C)FTB-01CUT(C)ORCOVE(C)FTB-01FT-01 (C)FTB-01CUT(C)ORCOVE(C)FTB-01FT-01 (C)FTB-01CUT(C)ORCOVE(C)FTB-01FT-01 (C)FTB-01CUT(C)ORCOVE(C)FTB-01 JAMES D. SMITH ARCHITECTSA-5.0NOTES:1.ACCENT ELEMENTS ARE 12' BREAK METAL SECTIONS, PRE-FINISHED TO MATCHPATTERN.2.PANELS TO BE INSTALLED AT THE CENTERLINE OF MONOLITH, INSTALLED OUTWARDAND MITER CUT EACH END IN FIELD.3.EACH PANEL (A and B) CONSISTS OF 3 UNIQUE ROWS (1, 2, and 3).4.PANELS SHOULD REPEAT A, B, A, B, ETC. UNTIL DESIRED WIDTH IS MET.1'-6"2"2"1'-6"2"12'-0"12'-0"ROW 1ROW 2ROW 3B PANELA PANEL2'-0"2'-0"4'-10"3'-2"3'-0"9'-0"2'-0"4'-0"5'-2"10"6'-0"3'-0"7'-0"2'-0"2'-0"5'-6"4'-6"PANEL 'A'PANEL 'B'LCOF MONOLITHLCOF MONOLITHORANGE BEAM LIGHTING OPTIONS- UNDERSIDE OF BEAM - WHEN USING THE NATIONAL ACCOUNTSPREFABRICATED ORANGE BEAM LED-13 SHALL BE PROVIDED BY THEVENDOR FOR THE UNDERSIDE OF THE BEAM; WHEN THE ORANGE BEAM ISFIELD FRAMED LED-2 SHALL BE PROVIDED BY THE G.C. AND USED ON THEUNDERSIDE OF THE BEAM- TOP OF BEAM - WHEN USING THE NATIONAL ACCCOUNTSPREFABRICATED ORANGE BEAM LED-13 SHALL BE PROVIDED BY THEVENDOR FOR THE TOP OF THE BEAM; WHEN THE ORANGE BEAM IS FIELDFRAMED LED-12 SHALL BE PROVIDED BY THE G.C. AND USED ON TOP OFTHE BEAM.PC-13PC-12 JAMES D. SMITH ARCHITECTSA-5.1S. YARMOUTH'A''B'LED-12 LIGHT FIXTURE ABOVE MONOLITH BAND TO BEINSTALLED MIN. 1" FROM E.I.F.S., REFER TO REFLECTED CEILINGPLANRECESSED LED-2 LIGHTFIXTURE, REFER TOREFLECTED CEILING PLAN1 12" E.I.F.S. OVER 5/8" EXT. GRADEPLYWOOD SHEATHING.REFER TO ELEVATION FOR FINISH2 3/4" ALUM. ANGLE. PAINT INSIDEFACE WHITE; OUTER FACE TOMATCH COLOR OF ELEMENT IT ISINSTALLED ON (TYP.)EXISTING FINISH PER EXTERIOR ELEVATIONSG.C. TO PROVIDE BLOCKING @PREFAB CANOPY AS REQUIRED.PRE-FABRICATEDORANGE BEAM/CANOPY.REFER TO ELEVATIONSFOR FINISH.'B ALT.'12" EXT. GRADE PLYWOOD SHEATHINGWITH WEATHER RESISTANT BARRIER.SLOPE PLYWOOD TO DRAIN W/ BLOCKINGAS REQUIRED (14" PER FOOT MIN)LED LIGHT FIXTURE ABOVEMONOLITH BAND TO BE INSTALLEDMIN. 1" FROM E.I.F.S., REFER TOREFLECTED CEILING PLANRECESSED LED LIGHTFIXTURE, REFER TOREFLECTED CEILING PLANCONT. BREAK MTL. REFER TOELEVATIONS FOR FINISH.12" EXT. GRADE PLYWOODSHEATHING"2x8" WOOD STUDS @ 16" O.C.LED-13 TAPE LIGHT FIXTURE ON TOP OF ORANGE BEAM, REFER TO REFLECTED CEILING PLANPRE-FABRICATED ORANGEACCENT BEAM. REFER TOELEVATIONS FOR FINISH.G.C. TO PROVIDE BLOCKING@ PREFAB ORANGE ACCENTBEAM AS REQUIRED.LED-13 TAPE LIGHT W/ LIGHTDIFFUSER AT THE BOTTOM OFORANGE BEAM, REFER TOREFLECTED CEILING PLANMETAL FLASHING TIED INTO AWRB WITHDRYVIT/TREMCO FLASHING MATERIAL3/4" GAP W/ BACKER ROD & SEALANT3/4" GAP W/ BACKER ROD & SEALANTMETAL FLASHING TIED INTO AWRB WITHDRYVIT/TREMCO FLASHING MATERIALDRAINAGE STRIP AT E.I.F.S. TERMINATIONTERMINATE E.I.F.S. 2"ABOVE METAL BANDEXISTING EIFS FINISHPER EXTERIOR ELEVATIONSEXISTING EIFS FINISHPER EXTERIOR ELEVATIONSDRAINAGE STRIP AT E.I.F.S. TERMINATIONTERMINATE E.I.F.S. 2"ABOVE METAL BAND JAMES D. SMITH ARCHITECTSA-5.2NOTE:INSTALLER MUST BE SURE TO SHIMCANOPY PLATE AT BOTTOM, ANDADJUST ANCHOR BOLTS ATBOTTOM OF COLUMN SO THAT THECANOPY SITS WITH A 18" / FT FALLFROM OPEN SIDE TO POLE SIDE SOWATER WILL DRAIN OFF POLE SIDE.NOTE:SEE DUNKIN' BRANDS WEBSITE, http://extranet.dunkinbrands.com,FOR COMPLETE INFORMATION AND DETAILSPMSCOLORS:VINYL/PAINTPMS 165 DD ORANGETRANS 3M #3630-3123PMS 219 DD PINKTRANS 3M #3630-1379PMS 7540C DD GRAY TRANS 3M #7725-41PMS COOL GRAY 1C TRANS 3M #7725-11NON-ILLUMINATED DRIVE-THRU STRUCTURENOTES:1.PAINT TO MATCH ORANGE PMS 165C, GLOSS FINISH.2.PAINT TO MATCH PINK PMS 219C, GLOSS FINISH.3.PAINT TO MATCH PMS COOL GRAY 1C, GLOSS FINISH.4.OPTIONAL 24" x 24" MEDALLION SIGN WITH REMOVABLE /ADJUSTABLE PLATES, SINGLE SIDED VINYL.5.OPTIONAL REFLECTIVE FILM;3M IJ680CR-10 SCOTCHLITE REFLECTIVEMCS (LATEX OR SOLVENT INKS)8519 LUSTER PROTECTIVE LAMINATE PRINTED TO MATCH.·PMS 165 DUNKIN' ORANGE·PMS 219 DUNKIN' PINK·PMS 7540C DUNKIN' GRAY·PMS COOL GRAY 1CADDITIONAL NOTES:·ARTWORK FONT: DUNKIN SANS DISPLAY·120 VOLT CIRCUIT, TO BE CONFIRMED BY SITE·CLEARANCE TO BE CONFIRMED BY SITE4'-10"2'-1012"1'-1"3'-5"4'-10"4"1'-1"3'-5"CDEFG2'-612"AB5"SIGNAGE BOX AREA: 2.75 SQ. FT.LED ILLUMINATED DIRECTIONAL SIGNNOTES:1.5" x 1" x .063" ALUMINUM SPACE FRAME.2.1" ALUMINUM RETAINER.3.1" x 1" x 1/8" ALUMINUM ANGLE.4.4" x 4" x .075" SQUARE TUBE SUPPORT PAINTED ORANGE PMS 165C5.GE TETRA MAX 7100K WHITE LED'S. (OR GE REPLACEMENT EQUIVALENT).6.LED POWER SUPPLIES, AS REQUIRED.7.118" CLEAR SOLAR GRADE POLYCARBONATE FACE 2ND SURFACE.8.BACKGROUND COLOR TO BE 403 WHITE BACK-SPRAY.9.3M #3630-3123 DUNKIN' ORANGE TRANSLUCENT FILM 2ND SURFACE.10.3M #3630-1379 DUNKIN' PINK TRANSLUCENT FILM 2ND SURFACE.11.3M #7125-41 DUNKIN' GRAY TRANSLUCENT FILM 2ND SURFACE.ADDITIONAL NOTES:·ARTWORK FONT: DUNKIN SANS DISPLAY·EXTERIOR FINISH: PAINT PANTONE 7540C·INTERIOR FINISH: PAINTED REFLECTIVE WHITE·RETAINERS / FACE REMOVABLE FOR SERVICE ACCESS·ELECTRICAL: (1) 20-AMP / 120 VOLT CIRCUIT·U.L. LISTED47,82,115,634DRIVETHRU91012,1134HJIKLNMNOTE:SEE DUNKIN' BRANDS WEBSITE, http://extranet.dunkinbrands.com,FOR COMPLETE INFORMATION AND DETAILSPMSCOLORS:VINYL/PAINTPMS 165 DD ORANGETRANS 3M #3630-3123PMS 219 DD PINKTRANS 3M #3630-1379PMS 7540C DD GRAY TRANS 3M #7725-41PMS COOL GRAY 1C TRANS 3M #7725-111'-0" CONDUIT PROTECTION SIDE VIEWCURBD/T SURFACE312"10"MOUNTING PLATESETBACK 18" FROMFACE OF 6" CURBLINE OF D/TSURFACE1'-0" CONDUIT PROTECTION FRONT VIEW (SINGLE LANE)11'-0"(EXTENSION ARM)12'-6" 9'-6" 11'-0" CLEARANCE HEIGHT 2" 4"3/4" PVC GRAPHICS2'-0"2'-0" 10"7'-0"(CLEARANCE BAR)10"2'-412"4"312"31,26"3"433 1/2"x3 1/2"x3/16"SQUARE STEEL TUBESTEELMOUNTINGPLATE1,5FORMED CONCRETE TOPMIN 4" CONCRETEFILLED STEEL PIPEWITH BOLLARDCOVER; REFER TONATIONAL ACCOUNTS.3'-6"LINE OF PAVING -SEE SPECIFICATIONSPAVEMENT THICKNESSNOTES:1) SEE SITE PLAN FORLOCATIONS2) SEE EXTERIOR FINISHSCH. FOR BOLLARDCOVER SPEC.POURED CONCRETEFOOTINGREFER TO LOCALCODE FOR REQ.DEPTH OF FOOTING1'-6" 6'-10" OVERALL HEIGHT 5'-0"2'-0"4"8"6'-10"SIDE VIEWPOST AND BOXPAINTED TO MATCHPMS 7540C DD GRAY4'-5"2'-0"1'-4"4'-5"2'-0"1'-4"1'-012"A2'-3"4'-7"122'-0"12MULTIPLE PANELDIGITAL MENU BOARDSNOTE:SEE DUNKIN' BRANDSWEBSITE,http://extranet.dunkinbrands.com,FOR COMPLETEINFORMATION AND DETAILSNOTES:1.MENUBOARD ISPOWDER COATEDTO MATCH PMS7540C (CABINET,BASE CLADDING,DOOR FRAMES &EXTENDERFRAMES).2.SAMSUNG OHFSERIES DISPLAYMENUBOARDS,OHF55F - 55".ADDITIONAL NOTES:·ARTWORK FONT:DUNKIN SANSDISPLAYFRONT VIEWRUN CONDUIT FOR ELEC. &DATA TO BLDG., VERIFYSIZE w/ MANUFACTURERG.C. TO PROVIDEFOUNDATION, ANCHORBOLTS, CAGE, AND ALLRELATED ACCESSORIESPRIOR TO INSTALLATION.SIGN VENDOR TO SUPPLY10"FRONT VIEWSIDE VIEW4'-5"2'-0"1'-4"4'-5"2'-0"1'-4"LINE OF DTSURFACECURBA5 DEG.10"4'-0"6'-4"9'-0"4"MOUNTING PLATESETBACK 12" FROMFACE OF 6" CURBORDERHERE321'-6"2'-1" 2'-0" 4'-1" DT SURFACE TO SPEAKER 4"4"1,4210"x10"x3/16" SQUARESTEEL POLEREAR ACCESS PANEL10'-0 1/2" OVERALL HEIGHT DT SURFACEILLUMINATED DRIVE-THRU CANOPY SIGNNOTE:SEE DUNKIN' BRANDS WEBSITE,http://extranet.dunkinbrands.com,FOR COMPLETE INFORMATION AND DETAILSNOTES:1.PAINT TO MATCH ORANGE PMS 165C, GLOSSFINISH.2.PAINT TO MATCH PMS COOL GRAY 1C, GLOSSFINISH.3.BLACK VINYL, ARLON 2100-03, MIC BY OTHERS.4.BREAKAWAY SWIVEL TOP.ADDITIONAL NOTES:·ARTWORK FONT: DUNKIN SANS DISPLAY·120 VOLT CIRCUIT, TO BE CONFIRMED BY SITE·CLEARANCE TO BE CONFIRMED BY SITE·TOP HAS TWO DOWN LIGHTS3/4" THICKSTEEL PLATE1,4LED LIGHT SOURCEOPTION 1 (PREFERRED)OPTION 2 JAMES D. SMITH ARCHITECTSA-8.0Water FiltrationSystemHandSinkBEV. REF.(LOW HT.,BY COKE)5 WIDE BAKERY CASE82G5WR/5WLPOSOPTIONALPOS5'-0" POS142650B1426 EXPEDITOR VDUPOS OPTIONAL COIN DISPENSERO-T*120F*UCR142242" CASH CARTGO211445171B MONITOR FOR D/TCAMERAMONITOR FOR D/TTIMER375VDU215215244ASANDWICH STATIONDUKE 94 (7'-10")1 VDU, 1 PRINTER*246A*6336HOOD ABOVE101L101C-3202AICE BINCUPS1504BEVERAGE VDU3'-6"CUPSCUPSLID HOLDER1516101C-3SPOONHOLDER1500124B124G124B124B124B124G2 DBL. WARMERS104ASHELF FOR 2PRINTERS & 1BUMP BAR1507UCR*120F*96.4ESPRESSO1523A6'-3" TAPS ONLY KNEEWALL2578 HEAD TAP SYSTEM886B886C886C10"3'-6 1/2"BUMP BAR FOR EXPEDITOR VDUOTGO PRINTER (UNDERCOUNTER)OPTIONAL OSB VDU(6'-8" AFF TO BOTTOM OF UNIT)6'-0" ORDERPICK-UPLEGS-S-21LEGS-S-2134634614251425OMOPICK-UP(W/ SHELVING)142714273'-0" ORDERPICK-UP (ext.)LEGS-S-211427346ICE BINCUPS15031503BEVERAGE VDU 3'-6"CUPS CUPS101C-3104ASHELF FOR 2PRINTERS & 1BUMP BARLID HOLDER151696.4ESPRESSO 202A101C-3101L1507 *120F*116.1ISLANDOASIS1507UCR*120F*119HOTCHOCOLATE3-TIERMERCHANDISING8773-TIERMERCHANDISING877KIOSKADAClearanceCONDIMENTS/ TRASH36COND48" W. TABLEICB200A143615281425SYRUP RACKPOWDER RACK1409LID HOLDER1516116.1ISLANDOASIS1513 BAKERYCASE70.5B*101Q-3*DBL. LIDHOLDER1517Trash1510124B124E395HANDSINK1531LID HOLDER1516SYRUP RACKPOWDER RACK14091523ACONDIMENTS/ TRASH36CONDLID HOLDER1516 1500 *101Q-3*124B124G124B 124B124B124G2 DBL. WARMERS TRASHCOMPOST1508124A124B 124BDBL. LIDHOLDER1517ADCB1A-8.1ADCB2A-8.1ADCB3A-8.1CBA4A-8.11A-8.0116.1140996.4104A101C-3101C101L124G124G*120F**120F*124E101Q-31A8.0OPEN TO BEYONDBACKLINE SOFFITPT-01CWT-01CT-03124A124G124G101Q101C101L96.4104A101C-3116.1BA2A-8.12A8.0WT-01CT-03EXISTINGEXISTINGA.A.395VDUWT-01CT-03B.EXISTING3A-8.0OPEN TOHALL(EXIST.) PT-02 (C)3A8.05'-0" MIN.WT-02RUNS ONYARMOUTHCT-024A-8.05A-8.04A8.0CT-02WT-01CT-03EXISTINGEXISTING GLASSCT-02EXISTING GLASS5A8.0PT-03 (C)PT-03 (C)1A8.0PT-03 (C)PT-03 (C)PT-03 (C)CT-02DMB JAMES D. SMITH ARCHITECTSA-8.1THE GENERAL CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE BARRIER FREE REQUIREMENTS FOR THEAPPLICABLE STATES AND THE AMERICAN DISABILITIES ACT (ADA) AND SHALL ENSURE THAT THIS FACILITY WILL BEACCESSIBLE ACCORDING TO THE STRICTER REQUIREMENTS OF THE APPLICABLE STANDARDS. THE FOLLOWING IS APARTIAL LIST OF REQUIREMENTS.1.DOOR HARDWARE SHALL BE MOUNTED BETWEEN 36" AND 42" ABOVE FLOOR AND BE LEVER TYPE.2.TOILETS:A.LAVATORY TO HAVE LEVER HANDLES, SELF METERING FAUCETS OR SPRING FAUCET. FAUCETS SHALLBE SET TO REMAIN OPEN FOR 10 SECONDS MINIMUM.B.A COAT HOOK 48" ABOVE THE FLOOR SHALL BE MOUNTED ADJACENT TO THE BARRIER FREE STALLDOOR.C.LOCATE THE WATER CLOSET 16" TO 18" FROM THE CENTER LINE OF THE FIXTURE TO THE WALL. THESEAT WILL BE 17" TO 19" ABOVE THE FLOOR TO THE TOP OF SEAT. FLUSH HANDLE TO BE ON EXPOSEDSIDE OF WATER CLOSET.D.PROVIDE ONE 42" AND ONE 36" LONG x 1 1/2" OUTSIDE DIAMETER PEENED GRAB BARS, 1 1/2" FROM THEWALL WITH ONE BEHIND AT 12" FROM CENTER LINE OF WATER CLOSET ON ONE SIDE. ONE ADJACENTTO AT 12" FROM THE WALL 33"-36" PARALLEL TO AND ABOVE THE FLOOR.E.LAVATORY TO BE MOUNTED 34" MAX. ABOVE THE FINISHED FLOOR TO RIM WITH KNEE SPACE OF 30" INWIDTH AND 27" IN CLEAR HEIGHT. (29" CLEAR UNDER FRONT EDGE)F.INSTALL MIRROR 40" MAX. ABOVE THE FINISHED FLOOR TO BOTTOM EDGE OF REFLECTING SURFACE(MIRROR GLASS BOTTOM) AND 72" TO TOP.G.DISPENSERS TO BE MOUNTED A MAXIMUM OF 42" ABOVE THE FLOOR TO ALL OPERATING OR DISPENSINGSLOTS.H.TOILET PAPER DISPENSERS MOUNTED 19" MIN. TO CENTER LINE ABOVE THE FLOOR AND 7" MINIMUM AND9" MAXIMUM FROM FRONT EDGE OF WATER CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSERADA NOTES:1.2 SOAP DISPENSERS - PROCTOR AND GAMBLECOMPANY - SEE NATIONAL ACCOUNT SOURCEINFO ON EXTRANET.2.CHEMICAL DISPENSER - PROCTOR ANDGAMBLE COMPANY - SEE NATIONAL ACCOUNTSOURCE INFO ON EXTRANET.3.7 SHELF STANDARDS - KNAPE & VOGT, 87ANO-24 IN4.14 SHELF BRACKETS - KNAPE & VOGT, 187LLANO-12 IN5.14 SHELF CLIPS - KNAPE AND VOGT, 214 BLK6.PAPER TOWEL HOLDER - AMERICANSPECIALTIES, INC., 0245SSKITCHEN AND STO. ACCESSORIESLINE OF GYP. BOARDCEILING (TYP.)3'-4"NOTE: LAVATORY TO HAVE LEVERHANDLES, SPRING FAUCETS ORSELF-METERING FAUCETSBOTTOM OFREFLECT. SURF.ACCENTMIRROR85"EMPLOYEES MUST WASH HANDS"SIGN MOUNTED @ 4'-6"2'-10"18"G.C. TO PROVIDEPROTECTIVE PIPECOVERS FOR ALLEXPOSED PIPING ATHAND SINK (TYP.)D.B.7" - 9"17"-19"12"MAX.17"-19"13'-6"1'-7" MIN. 8'-0"TOILET PAPER DISPENSER(SUPPLIED FREE BY LOCALDCP, G.C. TO INSTALL)WT-03LINE OF GYP. BOARDCEILING (TYP.)44'-0"PT-02 (W)DOORAND FRAMEWT-038'-0"63'-6" MAX.ADA HANDDRYER WITHWALL GUARDKIT7LINE OF GYP. BOARDCEILING (TYP.)WT-04(W)2A-9.08'-0"A.1A8.1LAVATORYWT-03LINE OF GYP. BOARDCEILING (TYP.)16" MIN / 18" MAX3'-0"TOILET1'-0"ACCESSIBLEGRAB BAR"EMPLOYEES MUST WASH HANDS"SIGN MOUNTED @ 4'-6"3'-512"1C.LINE OF GYP. BOARDCEILING (TYP.)3'-4"NOTE: LAVATORY TO HAVE LEVERHANDLES, SPRING FAUCETS ORSELF-METERING FAUCETSBOTTOM OFREFLECT. SURF.ACCENTMIRROR85"EMPLOYEES MUST WASH HANDS"SIGN MOUNTED @ 4'-6"2'-10"18"G.C. TO PROVIDEPROTECTIVE PIPECOVERS FOR ALLEXPOSED PIPING ATHAND SINK (TYP.)C.A.7" - 9"17"-19"12"MAX.17"-19"13'-6"1'-7" MIN. 8'-0"TOILET PAPER DISPENSER(SUPPLIED FREE BY LOCALDCP, G.C. TO INSTALL)WT-03LINE OF GYP. BOARDCEILING (TYP.)44'-0"PT-02 (W)DOORAND FRAMEWT-038'-0"63'-6" MAX.ADA HANDDRYER WITHWALL GUARDKIT7LINE OF GYP. BOARDCEILING (TYP.)WT-04(W)2A-9.08'-0"B.2A8.1LAVATORYWT-03LINE OF GYP. BOARDCEILING (TYP.)16" MIN / 18" MAX3'-0"TOILET1'-0"ACCESSIBLEGRAB BAR"EMPLOYEES MUST WASH HANDS"SIGN MOUNTED @ 4'-6"3'-512"1D.C.3A8.1PT-01 (C)WC-01 (C)ORCT-02LINE OF DROPCEILINGPT-02 (C)B.8'-0"ADA SIGN1/4"THICKSIGNSGRADE 2BRAILLENOTE:ARCHITECT TO VERIFYSYMBOLS FOR SIGNS PERLOCAL CODE. SIGNS MUSTCOMPLY WITH ALL STATEAND FEDERAL SIGNAGEREGULATIONSOPEN TOSALESAREA8'-0"PT-01 (C)WC-01 (C)ORCT-02LINE OF DROPCEILINGPT-02 (C)18" x 18" CLEAR SPACESHALL BE PROVIDEDCENTERED ON AND INFRONT OF ADA BRAILLESIGN (TYP., U.N.O.)V.I.F.LOCATIONC/LGRADE 2 BRAILLE ADA ROOM IDENTIFICATIONSIGN MTO @ LATCH SIDE OF THE DOORACRYLIC RESTROOM GRAPHIC PROVIDEDBY DGS & INSTALLED BY G.CD.PT-01 (C)WC-01 (C)ORCT-02LINE OF DROPCEILINGPT-02 (C)8'-0"18" x 18" CLEAR SPACESHALL BE PROVIDEDCENTERED ON AND INFRONT OF ADA BRAILLESIGN (TYP., U.N.O.)V.I.F.LOCATIONGRADE 2 BRAILLE ADA ROOM IDENTIFICATIONSIGN MTO @ LATCH SIDE OF THE DOORACRYLIC RESTROOM GRAPHIC PROVIDEDBY DGS & INSTALLED BY G.C18"C/LA.PT-01 (C)WC-01 (C)ORCT-02LINE OF DROPCEILINGPT-02 (C)8'-0"B.EXISTING GLASSLINE OF GYP. BOARDCEILING (TYP.)EXISTING GLASSLINE OF GYP. BOARDCEILING (TYP.)PT-01 (C)WC-01 (C)ORPT-01 (C)WC-01 (C)ORC.EXISTING GLASSLINE OF GYP. BOARDCEILING (TYP.)PT-01 (C)WC-01 (C)ORA.4A8.18'-0"13 JAMES D. SMITH ARCHITECTSA-9.02ACCENT WALL TILE (WT-04) INSTALL. PATT. @ REST-RM1 1/2" = 1'-0"NOTE:1WALL TILE (WT-01) INSTALLATION PATTERN @ BACKLINE/ SERVICE AREA1 1/2" = 1'-0"NOTE:AACBDCTILE PATTERNSTARTING POINTLINE OF WALLLINE OF CEILINGABDCABDCABDCNOTES:TILE PATTERN TO BE RANDOM. INSTALLPER THE GUIDELINES BELOW:·TILE A - START OF TILE PATTERN.·TILE B = TILE "A" ROTATEDCOUNTER CLOCKWISE 90 DEG.·TILE C = TILE "B" ROTATEDCOUNTER CLOCKWISE 90 DEG.·TILE D = TILE "C" ROTATEDCOUNTER CLOCKWISE 90 DEG.BDACBDDCBADCBANOTES:TILE PATTERNTO BE RANDOM.STACKED TILE LINE 1STACKED TILE LINE 2ACBDACBDLINE OF TILECREATIVE SOLUTIONSMATERIALSABDCDALTILEABDCABDCABCDTILE PATTERNSTARTING POINTLINE OF WALLLINE OF CEILINGNOTES:TILE PATTERN TO BE RANDOM. INSTALLPER THE GUIDELINES BELOW:·TILE A - START OF TILE PATTERN.·TILE B = TILE "A" ROTATEDCOUNTER CLOCKWISE 90 DEG.·TILE C = TILE "B" ROTATEDCOUNTER CLOCKWISE 90 DEG.·TILE D = TILE "C" ROTATEDCOUNTER CLOCKWISE 90 DEG.NOTES:1.CHAIR RAIL TO BE FASTENED TO STUDS; PROVIDEBLOCKING AS REQUIRED.2.ALL OUTSIDE CORNERS TO RECEIVE ACROVYN 4000SERIES 1 12" x 1 12" "BRUSHED NICKEL". CORNER GUARDS,FROM TOP OF WALL BASE TO 5'-6" A.F.F.TO BE CUTDOWN @ CHAIR RAIL AND CONTINUE ABOVE; PROVIDECORRESPONDING CHAIR RAIL CORNER PIECE ASNEEDED. REFER TO NATIONAL ACCOUNT FOR FURTHERINFO.3WALL PROTECTION OPTIONS AND DETAILS - WARM PALETTE3" = 1'-0"NOTE:TOP OF CHAIR RAILEL. = 2'-6 1/2" A.F.F.WP-CR1 CHAIR RAIL . ALUMINUM CHAIRRAIL RETAINER TO BE FASTENED TOWOOD BLOCKING2" x 4" WOOD BLOCKINGBEHIND CHAIR RAILWALL BASE FTB-01 CUT(C)OR FTB-01 COVE(C)WP-CR2(C) CHAIR RAILFRENCH CLEAT CUT INTO BACK OFSTONE TO FIT OVER AND GLUED TOSOLID WOOD MOUNTED TO WALL WITHMINIMAL GAPSFASTENED TO WALL12" SOLID WOOD W/ FRENCH CLEATFASTENED TO WALLTOP OF CHAIR RAILEL = 2'-6 1/2" A.F.F.ALUMINUM "J" CHANNEL CAPTOP OF WALL PROTECTION @ BASEEL = 4'-6" A.F.F.REFER TO PARTITIONTYPES FOR WALLASSEMBLYFINISHED FLOORFINISHED FLOOROPTION 1aOPTION 2aOPTION 3aREFER TO PARTITION TYPESFOR WALL ASSEMBLYREFER TO PARTITION TYPESFOR WALL ASSEMBLYFINISHED FLOOR2" x 4" WOOD BLOCKINGBEHIND CHAIR RAIL 14" HIGH-DENSITY FIBER BOARD(HDF) WITH LAMINATE SURFACEWP-PL2(C) OR WC-02(C)APPLIED DIRECTLY TO GWBSURFACE BELOW CHAIR RAILWALL BASE FTB-01 CUT(C)OR FTB-01 COVE(C)WALL BASE FTB-01 CUT(C)OR FTB-01 COVE(C) 14" HIGH-DENSITY FIBER BOARD (HDF)WITH LAMINATE SURFACE WP-PL2(C) APPLIED DIRECTLY TOGWB SURFACE BELOW CHAIR RAIL 14" HIGH-DENSITY FIBER BOARD(HDF) WITH LAMINATE SURFACEWP-PL2(C) OR WC-02(C)APPLIED DIRECTLY TO GWBSURFACE BELOW CHAIR RAILWC-01(C) OR WC-02(C) ORPT-01(C) ABOVE CHAIR RAILWC-01(C) OR WC-02(C) ORPT-01(C) ABOVE CHAIR RAILWC-01(C) OR WC-02(C) ORPT-01(C) ABOVE CHAIR RAIL JAMES D. SMITH ARCHITECTSK-1.0Water FiltrationSystemHandSink82G5WR142650B1426 EXPEDITOR VDUPOS OPTIONAL COIN DISPENSERBUMP BAR(VERTICAL ONMULLION/WALL)O-T*120F*142242" CASH CARTGO211445171B MONITOR FOR D/TCAMERAMONITOR FOR D/TTIMER375215215244ADUKE 94 (7'-10")1 VDU, 1 PRINTER*246A*6336HOOD ABOVE101L101C-3202ACUPS15043'-6"CUPSCUPS1516 101C-31500124B124G124B124B124B124G104ASHELF FOR 2PRINTERS & 1BUMP BAR1507*120F*96.41523A257886B886C886C10"3'-6 1/2"LEGS-S-21LEGS-S-213463461425142514271427LEGS-S-211427346CUPS 150315033'-6"CUPS CUPS101C-3104ASHELF FOR 2PRINTERS & 1BUMP BAR151696.4 202A101C-3101L1507 *120F*116.11507*120F*119877877KIOSKADAClearance36COND*641**924**924**643**924**924**924**924**649**924**924**924**924**641**924**924*200A1436 152814251409 1516116.11513 70.5B*101Q-3*15171510124B124E395 15311516 14091523A 36COND1516 1500 *101Q-3*124B124G124B 124B124B124G 1508124A124B 124B1517101L101C-3202ACUPS1504CUPS CUPS1516 101C-31500124B124G124B124B124B124G104ASHELF FOR 2PRINTERS & 1BUMP BAR1507*120F*96.41523A116.11507*120F**101Q-3*15171510124B124E 15311516 14091523A1516 K-2.0HYDROVECTION OVEN DOUBLE - NATURAL GAS 60"X36" STAINLESS STEEL FINISHING TABLE SQUARE MERCHANDISER SPECTAS 1912-369 STAINLESS STEEL CART 28"W x 30"L x 17"H REINFORCED TO HOLD (2) TURBO CHEF OVENS DD-30SLS-3017-C 5.0 DINING CHAIR - NICO/EARTHERN TWILL STOOL - NICO/EARTHEN TWILL SUPPLIER 24"X24" LAMINATE TABLE TOP 24"X33" ADA LAMINATE TABLE TOP MILLWORK MILLWORK ALLEMUIR DB432 ALLEMUIR DB433 MZ223-4D 8.3 ALLEMUIRCYLINDER TABLE - 24" DIA, 16" H / COOL PALETTE 30"X48" ADA LAMINATE TABLE TOP MC212-DD PLYMOLD 30048PVC MIXER CUP HOLDER WIREFAB WF 35897 LOCATION RUNS ON DUNKIN ART WORK COM-NG PLYMOLD 24048PVC24"X48" LAMINATE TABLE TOP COOL PALLETTE/WHITE TIGRIS SPM-475 PRODIGY ICE MAKER (PRODUCTION: UP TO 1553 LBS/ 24 HRS)C1448SA-32 DD-25SLS-3020-C MILLWORK 6PC COFFEE STORY & DONUT STORY WALL ART DGS RETAIL 880-NG-CAD-6PC FOR WALLS 16'-0" - 18'-6" DGS RETAIL 60" WIDE WATERFALL MERCHANDISER TABLE SPECTAS 2002-043 JAMES D. SMITH ARCHITECTS LID RACK WIREFAB WF 35873 RUBBERMAID AOT30TRASH CONTAINER OPEN TOP (22" ROUND) ELEVATION VIEWSHEETMETAL EXHAUST RISER. TRANSITIONAND OFFSET AS NEEDED INSTALL WITHCRIMPS "AGAINST AIR FLOW" TO PREVENTPOOLING OF CONDENSATE IN DUCT.3/8" ALL THREAD ANDHARDWAREUNISTRUT OR ANGLE IRONATTACHED TO TRUSS OR JOISTCEILINGIF TOP OF HOOD IS BELOW THE FINISHEDCEILING, HVAC CONTRACTOR IS TO FURNISH ASTAINLESS STEEL SHROUD.PLAN VIEWâ„„VDUTOASTERTURBOCHEFOVENS2HOOD 2 - ELEVATION AND PLANNONEDESIGN PROFESSIONAL TO DESIGN HOODFOR EVERY LOCATION PER CRITERIASHOWNJAMES D. SMITH ARCHITECTSM-2.0STEEL HANGING ANGLEUL 710 & ULC710 STANDARDSSLIDTERE.T.L. LISTED 3054804-001HOODS SHALL BEBUILT IN COMPLIANCE WITHNFPA #96NSFWITHY.IC,MHNNARBOAR NFPANo. 96RATOROABE T NSF STI NGLBUILTINACCORDANCE1HOOD 1 - NOT USEDNONEGENERAL NOTES:A.ALL ELECTRICAL "FIELD" CONNECTIONS AND RELATED INTERCONNECTIONS BY ELECTRICAL CONTRACTOR.B.ALL PLUMBING "FIELD" CONNECTIONS AND RELATED INTERCONNECTIONS BY PLUMBING CONTRACTOR.C.ALL ASSOCIATED HANGER MATERIALS BY INSTALLING CONTRACTOR.D.ANY LIGHTS SHOWN INSTALLED BY THE MANUFACTURER, AND FACTORY PREWIRED PER THE PLANS.INTERCONNECTIONS BETWEEN HOODS AND TO SWITCHES BY ELECTRICAL CONTRACTOR.E.SEISMIC RESTRAINTS ARE RESPONSIBILITY OF INSTALLING CONTRACTOR.F.INSTALLING CONTRACTOR ASSUMES ALL RELATED RESPONSIBILITY FOR VERIFICATION OF DIMENSIONAL DATACONTAINED ON THESE DOCUMENTS FOR ACCURACY, INTEGRATION, AND ADMINISTRATION OF CODE REQUIREMENTSIN EFFECT PRIOR TO ANY RELEASE FOR PRODUCTION OF EQUIPMENT SHOWN.G.SIGNED AND "APPROVED" COPIES OF THIS DOCUMENT MUST BE RECEIVED BY THE FACTORY PRIOR TOCOMMENCEMENT OF FABRICATION.H.NOMINAL HOOD DIMENSIONS AS SHOWN ON DRAWINGS.I.THE HOODS INDICATED SHALL BE CAPTIVE-AIRE MODEL VHB OR APPROVED EQUAL. THE HOOD SHALL BE SINGLEWALL TYPE HOOD WITH NO BUILT-IN MAKE-UP AIR CAPABILITIES. THE HOOD COMPONENTS SHALL BE FABRICATED OFTYPE 304 STAINLESS STEEL WITH A #3 OR #4 POLISH, ON ALL EXPOSED SURFACES. THE HOOD SHALL BE PROVIDEDWITH HANGING ANGLES ON EACH END OF THE HOOD. NOMINAL HOOD DIMENSIONS SHALL BE AS SHOWN ONDRAWINGS.3HANGING ANGLE DETAILNONE38" - 12" Ø HEAVY DUTY NUT. ONEABOVE AND TWO BELOW HANGINGANGLE.38" - 12" Ø ALL THREAD RODCONNECTED TO ROOF JOISTTHROUGH ANOTHER HANGINGANGLE.EXHAUST FAN AND GRILL WITH METAL CEILING TILES OVER THEOVENS AND TOASTERS IS THE MINIMUM REQUIREMENT PER DBISTANDARDS. THE ARCHITECT / ENGINEER IS RESPONSIBLE INDETERMINING IF AN ACTUAL HOOD IS THE MINIMUM REQUIREDPER LOCAL JURISDICTION.HOOD CONTROL SEQUENCE OF OPERATIONSMANUAL CONTROL:·TO TURN ON THE HOOD SYSTEM, PUSH THE FAN AND LIGHTS BUTTONS ON THETOUCH SCREEN USER INTERFACE. THE FANS AND LIGHTS WILL TURN ON AND THEINDICATING LIGHTS ADJACENT TO THE BUTTONS WILL ILLUMINATE INDICATING THEFANS AND LIGHTS ARE ON.·TO TURN OFF THE HOOD SYSTEM, PUSH THE FAN AND LIGHTS BUTTONS ON THETOUCH SCREEN USER INTERFACE. THE FANS AND LIGHTS WILL TURN OFF AND THEINDICATING LIGHTS ADJACENT TO THE BUTTONS WILL GO OUT INDICATING THE FANSAND LIGHTS ARE OFF.·THE HOOD WILL REMAIN ON BASED ON DIFFERENTIAL TEMPERATURE BETWEEN THEROOM THERMOSTAT AND THE HOOD TEMPERATURE PROBE. ONCE THE EQUIPMENTCOOLS DOWN, THE HOOD WILL SYSTEM WILL TURN OFF AUTOMATICALLY.AUTOMATIC CONTROL:·THE HOOD SYSTEM WILL TURN ON AUTOMATICALLY ONCE THE TEMPERATURE WITHINTHE HOOD SYSTEM REACHES A SET TEMPERATURE. THE INDICATOR LIGHTADJACENT TO THE FANS BUTTON ON THE TOUCH SCREEN USER INTERFACE WILLILLUMINATE. THE LIGHTS WILL NEED TO BE TURNS ON MANUALLY.·THE HOOD SYSTEM WILL TURN OFF AUTOMATICALLY AS DESCRIBED ABOVE.GENERAL:·THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH CAPTIVE AIRE.·THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE ELECTRICALCONTRACTOR ON THE REQUIRED WIRING OF THE OF THE HOOD CONTROLS PER THECAPTIVE AIRE DRAWINGS. JAMES D. SMITH ARCHITECTSE-2.0Water FiltrationSystemHandSinkEXPEDITOR VDUPOS OPTIONAL COIN DISPENSERO-TGO21 MONITOR FOR D/TCAMERAMONITOR FOR D/TTIMERCUPSCUPSCUPSSHELF FOR 2PRINTERS & 1BUMP BAR10"3'-6 1/2"CUPS CUPS CUPSSHELF FOR 2PRINTERS & 1BUMP BARKIOSKADAClearance A.ALL CONDUIT SHALL BE RUN CONCEALED IN SO FAR AS IS PRACTICABLE. CONDUITSSHALL BE EXPOSED ONLY WHERE SO INDICATED ON THE DRAWINGS OR INUNFINISHED AREAS SUCH AS ELECTRICAL AND BOILER ROOMS.B.MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS NOTED OTHERWISE ON THE PLANS.C.RIGID METAL CONDUIT: HOT DIPPED GALVANIZED, MILD STEEL PIPE, ZINC COATEDTHREADS WITH AN OUTER COATING OF ZINC BICHROMATE, AS MANUFACTURED BYTRIANGLE, REPUBLIC, WHEATLAND OR EQUAL.D.INTERMEDIATE METAL CONDUIT (IMC): HOT DIPPED GALVANIZED, MILD STEEL PIPE,ZINC COATED THREADS WITH AN OUTER COATING OF ZINC BICHROMATE ASMANUFACTURED BY TRIANGLE, REPUBLIC, WHEATLAND OR EQUAL.E.FLEXIBLE METAL CONDUIT: GALVANIZED OR ZINC METALIZED STEEL, SINGLE STRIPINTERLOCKED CONSTRUCTION AS MANUFACTURED BY TRIANGLE, ANACONDA,AMERICAN FLEXIBLE CONDUIT, ELECTRIC-FLEX, OR EQUAL.F.ELECTRIC METALLIC TUBING (EMT): HOT DIPPED GALVANIZED, MILD STEEL TUBE,ZINC COATED, AS MANUFACTURED BY TRIANGLE, REPUBLIC, WHEATLAND OREQUAL.G.RIGID NONMETALLIC CONDUIT: SCHEDULE 40 PVC AS MANUFACTURED BY CARLONOR EQUAL.H.METAL CLAD CABLE: TYPE MC, COPPER CONDUCTOR, 600 VOLT THERMOPLASTICINSULATION, 90 DEG. C, INTERLOCKED STEEL TAPE ARMOR.I.ARMORED CABLE: TYPE AC, COPPER CONDUCTOR, 600 VOLT THERMOPLASTICINSULATION, 90 DEG. C.J.ANY EXPOSED RACEWAY SHALL BE RUN TRUE, PLUMB AND PARALLEL ORPERPENDICULAR TO BUILDING LINES.K.ALL CONDUCTORS SHALL BE COPPER.L.RACEWAYS SHALL BE SEALED WHERE ENTERING PULL BOXES OR STRUCTURES.M.SINGLE CONDUCTOR CABLES SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITWIRING (EXCEPT WHERE AC AND MC CABLE IS USED). MINIMUM SIZE WIRE SHALLBE #12 AWG UNLESS OTHERWISE INDICATED AND SHALL BE SIZED TO CONFORM TONORMAL NEC VOLTAGE DROPS. WIRE SIZES #10 AWG AND SMALLER SHALL BESOLID, #8 AWG AND LARGER SHALL BE STRANDED.N.FEEDERS AND ALL WIRING IN MOIST OR WET LOCATIONS UNDERGROUND ORUNDER THE SLAB SHALL BE 600 VOLT CODE TYPE THHN-THWN. BRANCH CIRCUITWIRING IN DRY LOCATIONS, ABOVE GRADE, IN THE INTERIOR OF THE BUILDINGSHALL BE 600 VOLT CODE TYPE THHN-THWN OR XHHW.O.WIRING TO RECESSED FIXTURE AND WITHIN FIXTURE RACEWAYS SHALL BE TYPETHHN, #12 AWG MINIMUM.P.EQUIPMENT GROUND: GREEN CONDUCTOR SHALL BE USED.ELECTRICAL WIRING METHOD208/240V, 30A/2P, 60HzNema 6-30P(2) TURBOCHEF OVENSPRINTER(DATA AND POWER)120V, 1800W, 15A/1P, 60HzNema 5-20PHOLDING UNITVDU(DATA AND POWER AT 115V)115V, 10.4A, Nema 5-15STATION REFRIG. 120V, 3.9A, 60Hz,Nema 5-15STATION REFRIG. 208/240V, 23.8/20.7A,1 PHASE, 60Hz, Nema 6-30PDUAL LANE TOASTER3'-5"TECHNOLOGY REQUIREMENTS·1 VDU·1 PRINTER·1 BUMP BARRECEPTACLES TAGGED WITH "USB" IN THE SALES & SEATING AREASSHALL BE HUBBELL #USB15X2W (WHITE) / NP26W (WHITE) COMBO USBCOMBO USB CHARGER WITH TAMPER-RESISTANT RECEPTACLE.SEATING AREA RECEPTACLES SHALL BE WHITE WITH WHITE COVER PLATEAND ARE TO BE MOUNTED AT 18" AFF. E-2.1JAMES D. SMITH ARCHITECTSPICK UPWINDOW JAMES D. SMITH ARCHITECTSSCALE GENERAL NOTES:A.REFER TO HTTP://EXTRANET.DUNKINBRANDS.COM FOR A LISTING OF APPROVED POS VENDORS BY CONCEPT.B.FINAL POS DRAWINGS NEED TO BE PROVIDED TO POS VENDOR THAT IS SELECTED.C.POS VENDORS REQUIRE DEDICATED ISOLATED GROUNDED (DIG) OUTLETS ON A 20 AMP CIRCUIT DEDICATED ONLY TOPOS EQUIPMENT. 60HZ, 120+/-10%. ALL POS TERMINALS AND VIDEO DISPLAY DEVICES REQUIRE A DUPLEX OUTLET.THE BACK OFFICE CONTROLLER REQUIRES A QUAD OUTLET. THE NETWORK SWITCH REQUIRES A DUPLEX. IFFEDERAL, STATE, AND LOCAL WIRING CODES DO NOT MEET THIS REQUIREMENT, CONTACT THE POS VENDOR FORINFORMATION ON ADDITIONAL EQUIPMENT THAT CAN BE PURCHASED TO MEET THIS REQUIREMENT. IF THISREQUIREMENT IS NOT MET, THE POS SYSTEM WARRANTY IS INVALID.D.ALL POWER INDICATED ON THIS PLAN MUST HAVE A THIRD WIRE, ISOLATED GROUND, AND BE TERMINATED WITHIN (4)FEET OF THE DEVICE.E.IG-5362 RECEPTACLES MUST BE USED FOR ALL POS UNITS. VDU UNITS AND SITE CONTROLLER UNIT (IN OFFICE).LABEL RECEPTACLES "POS ONLY".F.ALL LOW VOLTAGE WIRE SHALL BE CATEGORY 5e UNLESS OTHER WISE INDICATED.G.ALL LOW VOLTAGE CABLE TERMINATIONS SHALL BE BY THE ELECTRICAL CONTRACORH.LOW VOLTAGE CABLE RUN IN 112" CONDUIT FOR POS EQUIPMENT ONLY, AND MUST BE TERMINATED WITH RJ45 JACKS.ALL POS EQUIPMENT LINES TERMINATE AT THE FRONT COUNTER CHASE.I.A 12" MINIMUM SEPARATION MUST BE MAINTAINED BETWEEN LOW VOLTAGE WIRES AND POWER WIRING (TO AVOIDELECTRICAL INTERFERENCE).J.BRAND REQUIREMENTS DICTATE THAT A MINIMUM OF THREE CONDUITS BE USED FOR DATA LINES BETWEEN THEOFFICE AND OTHER PARTS OF THE STORE- ONE CONDUIT IS TO BE DEDICATED TO POS WIRING, ONE FOR DIGITALMENUBOARD DATA LINES, AND ANOTHER FOR NON-POS ITEMS (I.E. SECURITY CAMERAS, DT TIMERS, HEAD SETWIRINGK.EXACT # OF RECEPTACLES ON OFFICE MUST BE COORDINATED ON A PROJECT-BY-PROJECT BASIS IN TERMS OFEQUIPMENT LOCATED IN THE OFFICEL.ALL CEILING MOUNTED VDU'S TO BE SUSPENDED FROM UNISTRUT BY THREADED ROD W/ WHITE PVC SLEEVE.CONNECT UNISTRUT TO ROOF STRUCTURE. VDU BY POS VENDOR; UNITSTRUT & THREADED ROD BY G.C. UNISTRUTTO SUPPORT MINIMUM 50 LB. WEIGHTM.VDU MOUNTING HEIGHTS (TO BOTTOM OF MONITOR) ARE AS FOLLOWS:a.SANDWICH STATION - 68" A.F.F.b.DRIVE THRU - 61" A.F.F.N.DIGITAL MENUBOARD PREP WIRING:a.PROVIDE BOX, PLATE AND 1" DIA. CONDUIT FROM FROM (2) QUAD DATA OUTLETS IN MENUBOARD SOFFIT TO (2)QUAD DATA OUTLETS IN OFFICE WALL. EITHER (A) PROVIDE PULL STRING IN EACH CONDUIT (CAT 5 CABLING ANDFINAL DATA CONNECTIONS BY DMB VENDOR), OR (B) PROVIDE ALL CAT 5 CABLING AND FINAL CONNECTIONS TODATA PLATES/BOXES- COORD. W/ F'EEVIDEO DISPLAY UNITPRINTERPOINT OF SALE TERMINALVIDEO DISPLAY UNITVDURPPOINT OF SALES TERMINALPREP PRINTERPOSPPRECEIPT PRINTERROUTERRSITE CONTROL (SELF-MOUNTING)RADIANT ONLYFAXSCFAXPOS EQUIPMENT TAGSWITCHBOHPCBACK-OF-HOUSE PCSWUPSUPSMMODEMDRIVE THROUGH TIMERDTTDRIVE THROUGH CONSOLEDTCORDER TAKER TERMINALOTSCANNERBUMP BARVERIFONE SWITCHVSPAYMENT TERMINALPTCASH DRAWERCASHDRCOIN DISPENSERCDDATA OUTLET, RJ45DUPLEX RECEPTACLEMANAGER'S WORKSTATIONMWSDVR SECURITY SYSTEMDVRPRICE CONFIRMATION DISPLAYPCDORDER STATUS BOARDPCDKIOSK SWITCHKIOSKSWTEMP WIRELESS DIAL UPTEMPMDIGITAL MENU BOARD SWITCHDMBSWDIGITAL MENU BOARDDMBDRIVE THRU ORDERCONFIRMATION BOARDOCBDRIVE THRU DIGITAL PREVIEW BOARDDPBDRIVE THRU DIGITAL PREVIEW BOARDDPBSECURITY SYSTEM CAMERACAMDRIVE THRU EXTERIOR DIGITALMENU BOARDEXTDMBOTT VOICE OVER-IP VOIP (PHONE)OTTVOIP-DMB: PROVIDE (8) CAT 5 WIRE PULLS FROM(2) QUAD DATA OUTLETS IN MENU BOARDSOFFIT TO (2) QUAD DATA OUTLETS INOFFICE WALL-2 CONDUITS MIN SHALL BE USED BETWEENOFFICE & OTHER PARTS OF THE STORE1 CONDUIT FOR POS WIRING ONLY1 CONDUIT FOR NON-POS ITEMSCONDUIT NOTESGC POWER/DATA RESPONSIBILITY- EC TO RUN DEDICATED CONDUIT FROM POWER PANEL TO JUNCTION BOX ON BACK SIDE OF MENU BOARD FASCIA AT CENTER LINE OF POS- EC TO RUN CONDUIT WITH J-BOX FROM BACK SIDE OF MENU BOARDFASCIA AT CENTERLINE OF POS TO OFFICEDMB VENDOR POWER/DATA RESPONSIBILITY- CUT HOLE IN MENU BOARD FASCIA FOR POWER/DATA STACK- IN STALL POWER/DATA STACK IN FASCIA- RUN ELECTRICAL CONDUCTOR WIRE FROM MENU BOARD FASCIA TO ELECTRICAL PANEL- MAKE FINAL ELECTRICAL CONNECTION AT POWER/ DATA STACK- MAKE FINAL ELECTRICAL CONNECTION TO CIRCUIT AT POWER PANEL- RUN CAT-5E CABLES AND TERMINATE ENDS AT MENU BOARD FASCIAPOWER/DATA STACK AND IN OFFICE*PRIOR TO BIDDING OR PERFORMING WORK GC TO COORDINATE WITHAUTHORITY HAVING JURISDICTION (AHU). AHU MAY REQUIRE FULL WIRE PREPBY EC. GC TO ALERT CM, F'EE AND DMB INSTALLER IF EC MUST PERFORM ALLELECTRICAL INSTALL WORK.DIGITAL MENU BOARD RESPONSIBILITIES- G.C. TO PROVIDE A POWER / POS STUBUP FROM FLOOR OR A UNISTRUT RAILSUSPENDED FROM ROOF STRUCTURE @10'-6" A.F.F. FOR ELECTRICAL/DATACONNECTIONS AT ORDER KIOSKS.-20A CIRCUIT & (3) CAT-6 DATA CABLESEA - ALL WIRING & FINAL LOC'Ns TBD INFIELD w/ FRANCHISEE & MANUFREQUIREMENTS.-PROVIDE WIRING FROM KIOSK TOFRONT LINE POS AREA FOR "REMOTEASSISTANCE" w/ LIGHT AT POS UNIT -CONFIRM ALL REQUIREMENTS w/ MANUF.KIOSK NOTESDESCRIPTIONREMARKSAMPSVOLTSLOAD2.0LOVORJ45CB#100-240V100-120VRJ45NO100-120V100-120V2.0100-120V100-240V8.2YES100-120V4.0NO1.0NON/AN/A1.5YESYESNORJ450.5N/ARJ45NORJ451.2N/ARJ45RJ4524/34VLOW VOLTYESLOW VOLTLOW VOLTRJ45MUST BE WITHIN 60FT OF DISPLAYLOW VOLTLOW VOLT78265120V11216915214POINT OF SALES TERMINAL (POS)319A18RECEIPT PRINTER20PC SITE CONTROLLER EXTERNALPOS NETWORK HUB/ SWITCHPRINTER/FAX/COPIER (BOH)VDU CONTROLLER (PC BASED)CASH DRAWERSCANNERVDUDT TIMER VDU DISPLAYPREP PRINTERDRIVE THROUGH (DT) TIMER CONSOLEPHONE LINEFAX LINESHARES CIRCUIT WITH POS ITEMS 1 & 2SHARE CIRCUIT WITH POS ITEMS 1 & 12FORMERTRANSSHARES CIRCUIT WITH POS ITEMS 2 & 12N/ASHARES CIRCUIT WITH POS ITEMS 1, 2 & 12N/AN/ATERMN/AN/ARJ45RS232NON/ANORJ45N/ARJ45RJ45NON/A20A/1P20A/1P20A/1P20A/1PN/A20A/1PN/A20A/1P20A/1P4QTY7320A/1P143117011310OFFICELOCATION1OFFICEOFFICEOFFICEOFFICEOFFICEOFFICEUNDER CTR @ FRONT & D/T (2) FRONT COUNTER (1) D/T (1) D/T OT NOSHARES CIRCUITCONNECTED TO POS UNITS10RJ45CONNECTED TO D/T POS UNITPOS COFFEE FRONT CHASEFAX LINE FOR OFFICEPHONE LINE FOR OFFICENOT USED 022LOW VOLTHIGH SPEED INTERNET LINE (MNS)N/ARJ45N/A1OFFICE23LOW VOLTN/ARJ45N/A1SECURITY SYSTEM24FOR SITE CONTROLLER & BOH PCSYSTEM SECURITY DVRLOW VOLTDIGITAL MENU BOARDN/ARJ45N/A8OFFICE/SERVICE AREA25LOW VOLTWIFIN/ARJ45N/A1OFFICEPOS EQUIPMENT26(2) FRONT COUNTER PHONE & DATA LINESOTHER COMMUNICATION DEVICESSPARESPAREPLUGS INTO ROUTER PORT#2PLUGS INTO ROUTER PORT#4PLUGS INTO ROUTER PORT#5N/AN/ARJ4513NO1VERIFY ALL ELECT & POS REQTS w/ MANUFPOS EQUIP & WIRING BY OTHERS143PAYMENT TERMINALVERIFY ALL ELECT & POS REQTS w/ MANUF(2) FRONT COUNTERRJ45NO14a3VERIFONE SWITCH301ORDER STATUS BOARD(1) FRONT COUNTERVERIFY ALL ELECT & POS REQTS w/ MANUF100-240V0.520A/1P(2) FRONT COUNTERCONNECTED TO POS (1)7aPC SITE CONTROLLER INTERNAL1OFFICELOW VOLTSECONDARY WIFI ACCESS POINT (OPT)N/ARJ45N/A0OFFICE26aPLUGS INTO ROUTERLOW VOLTOTT VOIP (PHONE)N/ARJ45N/A1OFFICE27PLUGS INTO ROUTERMUSIC SYSTEMMUSIC PLAYER1OFFICE28NOT USED029MANAGER'S WORKSTATION131100-120V4.0NORJ4520A/1P110NOT USED WORKSTATIONMANAGER'S WORKSTATION (OPT)032OFFICEFIREWALLFIREWALL133BROADBAND MODEM134OFFICEOFFICELOW VOLTN/ARJ45N/ALOW VOLTN/ARJ45N/ASWITCHESSWITCH138DD UTILITY SWITCH (OPT)139OFFICEOFFICEDVR NETWORK SWITCH140OFFICE3536NOT USED37NOT USEDTEMPORARY WIRELESSBROADBAND DIAL-UP DATASOLUTIONOFFICE414211DIGITAL MENU BOARD SWITCHOFFICEKIOSK SWITCHOFFICEMENU BOARD445EXT DIGITAL MENU BOARDS246EXTERIOR DRIVE THRUDRIVE PREVIEW BOARD04748491ORDER COMFIRMATION BOARDNOT USED4344INT DIGITAL MENU BOARDSEXTERIOR DRIVE THRUEXTERIOR DRIVE THRUOPTIONAL COIN DISPENSER0POS-COMMUNICATIONS EQUIPMENT SCHEDULE(2) FRONT COUNTER (1) D/T (1) D/T(1) D/T(1) D/T(2) BEVERAGE STA (1) SANDWICH(3) EXPEDITER @ D/T(1) EXPEDITER @ HAND OFF3PRICE CONFIRMATION DISPLAYOUTSIDE @ D/T WINDOW (EXIST.), & BEHIND FRONT POS UNITS(2) BEVERAGE STATION (1) SANDWICH (1) OTGO PRINTERPOS LEGENDPOS PLAN1/4" = 1'-0"E-3.0Water FiltrationSystemPOSO-T 42" CASH CARTGO21 CUPSCUPSCUPSSHELF FOR 2PRINTERS & 1BUMP BARCUPS CUPS CUPS SHELF FOR 2 PRINTERS & 1BUMP BAR TECH REQUIREMENTS·1 VDU·1 PRINTER·1 BUMP BAR254532" MAX.CUPSCUPSCUPSSHELF FOR 2PRINTERS & 1BUMP BAR25357AE-3.1TECH REQUIREMENTS·2 POS TERMINALS·1 PRICE CONF.DISPLAY (EXTERIOR)·(1) CASH DRAWER·(1) PAYMENT TERM.·(1) SCANNER·(1) RECPT PRINTER·(1) EXPEDITOR VDU·(1) D/T TIMER DISPLAY·(1) DRIVE THRU CAMERAMONITOR (OPT)112113214VDU194POSO-T 42" CASH CARTGO214AE-3.1EXPEDITER VDUMOUNTED ON WALLw/ SWING MOUNT4OPTIONAL COINDISPENSER PLACED ONCOUNTER13OPTIONAL DRIVE THRUCAMERA MONITOR ABOVE4EXTERIOR PRICE-CONFIRMATION DISPLAY10DRIVE-THRU TIMERDISPLAY MOUNTEDTO WALL16ORDER TAKER POSTERMINAL ON COUNTER1RECEIPT PRINTER PLACEDON COUNTER2BUMP BAR FOREXPEDITOR VDUEXPEDITER BUMP BAR MOUNTEDTO F.O. COUNTER BELOW5OTG ALERT DEVICE & PREPPRINTER (STICKY MEDIA REQ'D)332" ORDER STATUSBOARD (CEILINGMOUNTED POSITIONEDTOWARD GUESTS)30EXPEDITER VDUMOUNTED ON COUNTER(POSITIONED TOWARD CREW)4OTGPICK-UPORDERPICK-UP3AE-3.12A E-3.1 5BUMP BAR MOUNTED TOFRONT OF STATION BELOW4VDU MOUNTEDTO WALL3EXPEDITER PREP PRINTER(STICKY MEDIA REQ'D)5330TECH REQUIREMENTS· 1 VDU· 1 32" OSB· 1 PRINTER· 1 BUMP BAR· 1 OSB CEILINGMOUNT, POLE, &BUTTERFLYMOUNT6" MIN 5'-10" BOTTOM OF POLE 4VDU5436AE-3.1119914142122125AE-3.1NOTE:NO TECHREQUIREMENTS12"MIN BAKERY TISSUE TOOCCUPY TOP SHELFRUN ELECT THRUMILLWORK CHASEPOSNETWORKHUBCASHDRORPOSVDUVIDEOCONTROLLEROR3PPIGIGIGIG5A546911232CDPTVS14a1413SWITCHOTTVOIP27MUSICPLAYER28FUTURE USEFUTURE USEFIREWALL33SW(OPT)39M34HIGH SPEED INTERNET FROM STREETDMBIGIG25MWSMWS(OPT)3231SC(INT)7ASC(EXT)7TEMPMIGDVRDVRSW2440IGPCD10OSB30IGWIFI2626aIGKIOSKRPPPPTIG3538KIOSKSW42IGDMBSW4245CAMCAMCAMCAM46OCBIG48EXTDMBIGIGDTTDTC1615KIOSKIGDPBIG477aBEVERAGE STATION ELEVATION1/4"=1'-0"4aD/T POS STATION ELEVATION1/4"=1'-0"4D/T POS STATION PLAN1/4"=1'-0"3HAND OFF STATION PLAN1/4"=1'-0"2SANDWICH STATION PLAN1/4"=1'-0"3aHAND OFF STATION ELEVATION1/4"=1'-0"2aSANDWICH STATION ELEVATION1/4"=1'-0"7aBEVERAGE STATION PLAN1/4"=1'-0"6POS STATION PLAN 1/4"=1'-0"6aPOS STATION ELEVATION1/4"=1'-0"5BAKERY CASE PLAN1/4"=1'-0"5aBAKERY CASE ELEVATION1/4"=1'-0"E-3.1JAMES D. SMITH ARCHITECTSTECHNOLOGY SCHEMATIC11/4" = 1'-0" JAMES D. SMITH ARCHITECTSP-1.0Water FiltrationSystemPOSO-T42" CASH CARTGO21CUPSCUPSCUPSCUPSCUPSCUPSSHELF FOR 2PRINTERS & 1BUMP BAR395 CONNECT TO EXISTING SITE WATER LINE. CONTRACTOR TO VERIFY SIZE AND LOCATION IN FIELD. PROVIDE BACKFLOWPREVENTOR PER REQUIREMENTS OF LOCAL JURISDICTION. PIPE INDIRECT DRAIN FROM TROUGH ON COUNTER AT COFFEE STATIONS TO FLOOR SINK. PROVIDE AIR GAP ASREQUIRED BY CODE. PROVIDE INDIRECT DRAIN FROM ICE CUBER AND ICE BIN TO ADJACENT FLOOR SINK. CONSULT ICE MACHINEINSTRUCTION MANUAL FOR INDIRECT PIPING REQUIREMENTS. PROVIDE THERMOSTATIC MIXING VALVE AT ALL HAND SINKS AND LAVATORIES IF NOT ALREADY PROVIDED WITHTHEM. SET AT 11O°F MAXIMUM.EXISTING WATER FILTERATION SYSTEM. PROVIDE A PRESSURE REDUCING VALVE, PRESSURE GAUGE, AND SHUT-OFF VALVE AT PLUMBING CONNECTIONS TOOVEN. PROVIDE A PRESSURE REDUCING VALVE FOR ESPRESSO MACHINE. PROVIDE VALVED MANIFOLD. TAG LINE AS TO FIXTURE SERVED. PROVIDE VALVELESS MULTI-PORT TEE. TAG LINE AS TO FIXTURE SERVED.KEY NOTESA.ALL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES AND AUTHORITIES HAVING JURISDICTION.B.THE CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS.C.THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS AND TRADES.D.THESE DRAWINGS, AS PREPARED, ARE DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS CONSTRUCTION OF THE PROJECT AND THE WORK OF THE TRADES WILL PERMIT. EQUIPMENT LOCATIONS INDICATED ARE APPROXIMATE. COORDINATE EXACT LOCATIONS AND REQUIRED CLEARANCES WITH EQUIPMENT SUPPLIER AND ALL TRADES PRIOR TO INSTALLATION.E.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL THE EQUIPMENT INDICATED WITHIN THESE DRAWINGS UNLESS OTHERWISE NOTED. VERIFY LOCATION AND DIMENSIONS IN THE FIELD PRIOR TO FABRICATION AND / OR INSTALLATION.F.ALL ROOF PENETRATIONS SHALL BE AT THE CONTRACTOR'S EXPENSE. COORDINATE WITH OWNER'S ROOFING CONTRACTOR SO AS NOT TO VOID ANY EXISTING ROOF WARRANTIES.G.THE ENTIRE INSTALLATION SHALL BE GUARANTEED FREE OF DEFECTS AND CONTRACTOR SHALL REPAIR AND / OR REPLACE ANY DEFECTIVE MATERIALS OR EQUIPMENT AT NO COST TO THE OWNER FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY ARCHITECT OR ENGINEER.H.ALL WORK SHALL BE SUBJECT TO THE ACCEPTANCE AND APPROVAL OF THE ARCHITECT AND OWNER. THE ARCHITECT SHALL BE NOTIFIED OF ANY AND ALL DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE CONTRACT DOCUMENTS BEFORE PROCEEDING WITH THAT PORTION OF THE WORK. FAILURE OF PROPER NOTIFICATION DOES NOT RELIEVE THE CONTRACTOR. THE CONTRACTOR SHALL CORRECT ANY AND ALL WORK ARISING FROM SUCH FAILURE TO COORDINATE DISCREPANCIES TO THE SATISFACTION OF THE ARCHITECT WITHOUT ADDITIONAL COST TO THE OWNER.I.ALL KITCHEN, PREP AREA AND SALES AREA EQUIPMENT WILL BE FURNISHED AND INSTALLED. EQUIPMENT WILL BE FURNISHED WITH TRIM, FAUCETS, ESCUTCHEONS, ETC. PLUMBING CONTRACTOR SHALL PROVIDE ALL ROUGH-IN TRAPS AND MAKE ALL FINAL CONNECTIONS (SEE EQUIPMENT SCHEDULE).J.ALL PIPING TO BE CONCEALED IN HUNG CEILINGS, CHASES AND FURRED SPACES.K.REFER TO EQUIPMENT SCHEDULE AND EQUIPMENT SPECIFICATIONS FOR EXACT LOCATIONS OF PLUMBING CONNECTIONS.L.THE CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION OF ALL EXISTING UTILITIES IN FIELD PRIOR TO STARTING WORK.M.THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL PIPE HANGERS, AND SUPPORTS IN ACCORDANCE WITH THE LOCAL APPLICABLE CODES.N.THE CONTRACTOR TO PROVIDE TRAP PRIMERS, DEEP SEAL TRAP OR TRAP SEAL ON ALL FLOOR DRAINS AS PER APPLICABLE CODE.O.ALL PENETRATIONS REQUIRED FOR PLUMBING EQUIPMENT AND PIPING THROUGH ANY WALL SHALL BE PROPERLY SEALED OFF TO MAINTAIN THE INTEGRITY OF THE STRUCTURE.P.ALL SHUT OFF AND ISOLATION VALVES SHALL BE BALL TYPE. ALL VALVES SERVING TOILETS AND SINKS SHALL BE ANGLE STOP TYPE.Q.PROVIDE AN INDIVIDUAL BALL VALVE AND BACK CHECK VALVE TO EACH INDIVIDUAL PIECE OF EQUIPMENT. R.PROVIDE BACKFLOW PREVENTERS AT ALL COFFEE MAKERS, BAGEL OVEN, DIPPING WELLS, ICE MAKER AND ALL OTHER EQUIPMENT AS REQUIRED BY CODE.S.PROVIDE AERATORS ON ALL HAND SINKS AND LAVATORIES THROUGHOUT THE FACILITY.T.PROVIDE KAY CHEMICAL DISPENSER (SEE NATIONAL ACCOUNTS) AT MOP SINK AND THREE COMP SINK. MOUNT BOTTLE AND DISPENSER ABOVE SINK AS REQUIRED BY CHEMICAL SUPPLIER. JAMES D. SMITH ARCHITECTSP-2.0 CONNECT TO EXISTING SITE WATER LINE. CONTRACTOR TO VERIFY SIZE AND LOCATION IN FIELD. PROVIDE BACKFLOWPREVENTOR PER REQUIREMENTS OF LOCAL JURISDICTION. PIPE INDIRECT DRAIN FROM TROUGH ON COUNTER AT COFFEE STATIONS TO FLOOR SINK. PROVIDE AIR GAP ASREQUIRED BY CODE. PROVIDE INDIRECT DRAIN FROM ICE CUBER AND ICE BIN TO ADJACENT FLOOR SINK. CONSULT ICE MACHINEINSTRUCTION MANUAL FOR INDIRECT PIPING REQUIREMENTS. PROVIDE THERMOSTATIC MIXING VALVE AT ALL HAND SINKS AND LAVATORIES IF NOT ALREADY PROVIDED WITHTHEM. SET AT 11O°F MAXIMUM.EXISTING WATER FILTERATION SYSTEM. PROVIDE A PRESSURE REDUCING VALVE, PRESSURE GAUGE, AND SHUT-OFF VALVE AT PLUMBING CONNECTIONS TOOVEN. PROVIDE A PRESSURE REDUCING VALVE FOR ESPRESSO MACHINE. PROVIDE VALVED MANIFOLD. TAG LINE AS TO FIXTURE SERVED. PROVIDE VALVELESS MULTI-PORT TEE. TAG LINE AS TO FIXTURE SERVED.KEY NOTESA.ALL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES AND AUTHORITIES HAVING JURISDICTION.B.THE CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS.C.THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS AND TRADES.D.THESE DRAWINGS, AS PREPARED, ARE DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS CONSTRUCTION OF THE PROJECT AND THE WORK OF THE TRADES WILL PERMIT. EQUIPMENT LOCATIONS INDICATED ARE APPROXIMATE. COORDINATE EXACT LOCATIONS AND REQUIRED CLEARANCES WITH EQUIPMENT SUPPLIER AND ALL TRADES PRIOR TO INSTALLATION.E.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL THE EQUIPMENT INDICATED WITHIN THESE DRAWINGS UNLESS OTHERWISE NOTED. VERIFY LOCATION AND DIMENSIONS IN THE FIELD PRIOR TO FABRICATION AND / OR INSTALLATION.F.ALL ROOF PENETRATIONS SHALL BE AT THE CONTRACTOR'S EXPENSE. COORDINATE WITH OWNER'S ROOFING CONTRACTOR SO AS NOT TO VOID ANY EXISTING ROOF WARRANTIES.G.THE ENTIRE INSTALLATION SHALL BE GUARANTEED FREE OF DEFECTS AND CONTRACTOR SHALL REPAIR AND / OR REPLACE ANY DEFECTIVE MATERIALS OR EQUIPMENT AT NO COST TO THE OWNER FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY ARCHITECT OR ENGINEER.H.ALL WORK SHALL BE SUBJECT TO THE ACCEPTANCE AND APPROVAL OF THE ARCHITECT AND OWNER. THE ARCHITECT SHALL BE NOTIFIED OF ANY AND ALL DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE CONTRACT DOCUMENTS BEFORE PROCEEDING WITH THAT PORTION OF THE WORK. FAILURE OF PROPER NOTIFICATION DOES NOT RELIEVE THE CONTRACTOR. THE CONTRACTOR SHALL CORRECT ANY AND ALL WORK ARISING FROM SUCH FAILURE TO COORDINATE DISCREPANCIES TO THE SATISFACTION OF THE ARCHITECT WITHOUT ADDITIONAL COST TO THE OWNER.I.ALL KITCHEN, PREP AREA AND SALES AREA EQUIPMENT WILL BE FURNISHED AND INSTALLED. EQUIPMENT WILL BE FURNISHED WITH TRIM, FAUCETS, ESCUTCHEONS, ETC. PLUMBING CONTRACTOR SHALL PROVIDE ALL ROUGH-IN TRAPS AND MAKE ALL FINAL CONNECTIONS (SEE EQUIPMENT SCHEDULE).J.ALL PIPING TO BE CONCEALED IN HUNG CEILINGS, CHASES AND FURRED SPACES.K.REFER TO EQUIPMENT SCHEDULE AND EQUIPMENT SPECIFICATIONS FOR EXACT LOCATIONS OF PLUMBING CONNECTIONS.L.THE CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION OF ALL EXISTING UTILITIES IN FIELD PRIOR TO STARTING WORK.M.THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL PIPE HANGERS, AND SUPPORTS IN ACCORDANCE WITH THE LOCAL APPLICABLE CODES.N.THE CONTRACTOR TO PROVIDE TRAP PRIMERS, DEEP SEAL TRAP OR TRAP SEAL ON ALL FLOOR DRAINS AS PER APPLICABLE CODE.O.ALL PENETRATIONS REQUIRED FOR PLUMBING EQUIPMENT AND PIPING THROUGH ANY WALL SHALL BE PROPERLY SEALED OFF TO MAINTAIN THE INTEGRITY OF THE STRUCTURE.P.ALL SHUT OFF AND ISOLATION VALVES SHALL BE BALL TYPE. ALL VALVES SERVING TOILETS AND SINKS SHALL BE ANGLE STOP TYPE.Q.PROVIDE AN INDIVIDUAL BALL VALVE AND BACK CHECK VALVE TO EACH INDIVIDUAL PIECE OF EQUIPMENT. R.PROVIDE BACKFLOW PREVENTERS AT ALL COFFEE MAKERS, BAGEL OVEN, DIPPING WELLS, ICE MAKER AND ALL OTHER EQUIPMENT AS REQUIRED BY CODE.S.PROVIDE AERATORS ON ALL HAND SINKS AND LAVATORIES THROUGHOUT THE FACILITY.T.PROVIDE KAY CHEMICAL DISPENSER (SEE NATIONAL ACCOUNTS) AT MOP SINK AND THREE COMP SINK. MOUNT BOTTLE AND DISPENSER ABOVE SINK AS REQUIRED BY CHEMICAL SUPPLIER. Water FiltrationSystemPOSO-T42" CASH CARTGO21CUPSCUPSCUPSSHELF FOR 2PRINTERS & 1BUMP BAR10"3'-6 1/2"CUPS CUPS CUPSSHELF FOR 2PRINTERS & 1BUMP BAR2"V2"S2"V2"S3"S 3"S 3"S 3"S 3"S3"S ESPRESSOMACHINES(2)SINGLE COFFEEBREWERTWIN COFFEEBREWERSOFTENINGCARTRIDGE(LOCATEDIN BOH)ISLAND OASISMACHINES(2)ICED COFFEEBREWERHOT WINTERBEVERAGEMACHINESPRAYEROVENOPTIONALBOOSTER PUMPMCANN'S: 16-2173-DD WATER BOOSTERTWIN FILTRATION SYSTEMSERVICE ENTRANCE NOTE:SYMBOL LEGENDWATER QUALITYINSTALLATION CHECKLIST:FRONT OF HOUSE (FOH)BACK OF HOUSE (BOH)DUNKIN' DONUTS WATER SPECIFICATION & TREATMENT REQUIREMENTSUTILITY WATER CONNECTIONS3/4"3/4"UTILITY WATER CONNECTIONSICE MAKER FILTERICE MAKER (1)FRONT OF HOUSE (INCLUDING DRIVE THRU)P-3.0JAMES D. SMITH ARCHITECTS8 HEAD TAPSYSTEMEXISTING