HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. � �/ Lot {� d g a 8,. 3 3
'/ Zone of Contribution: In Out Acreage
1 Commercial: Residential: L----
Street:
Village: Floor Plan: 1- #Bedrooms: 3
- ra . (
Owner: Installer: 13zfg ,icI/
Address: Phone:
Phone:
Builder: Engineer:c., L..r.,---ty
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received /
2.Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table %�
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.:
11.1
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
L
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: I�
15. System not in top or subsoil(A,B horizons)or 5' removal
16. Proposed contours are suitable , /'
17. System meets slope requirements-min. 1/8", 'A"preferred j '
18. System meets breakout requirements PVC liner: Wall: i
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel _
21.No garbage disposal i '
22. System adequately sized for its intended use y '
23.Minimum 6"stone or compacted below tank and dbox z.- ,
24.Manhole covers within 6"of grade, pump chamber cover to grade i/"`
25. Inspection port on plastic chambers/leach field a�
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size //
28. Septic tank/pump chamber to be factory waterproofed ,"
29. Vent provided if leaching below 3 feet,under driveway/parking e/
30. Buoyancy calculations for tank/pump chamber ,/
31. Engineer to inspect and certify soils: wall: commercial: / .
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature e'
35. Foundation footing min.2 feet above adjusted ground water for new house /
36.Deed Restriction required max. #bedrooms: max. flow: gpd /
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed b_- - __ r c o;o: