BLDE-23-000293 PLANS i LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION SE IBC/IEBC), SOLAR MODULES L S PV-1.0 COVER SHEET STALLATION SERVICE ENTRANCE a $ - -I- PV-2.0 SITE PLAN PV-3.0 LAYOUT Kv-IF)) MAIN PANEL 120 PV-4.0 ELECTRICAL SNR MOUNT PV-5.0 SIGNAGE 4RE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT 140 PV LOAD CENTER CHIMNEY 10 SUNRUN METER DI ATTIC VENT I, OR TYPE II Li, DEDICATED PV METER = FLUSH ATTIC VENT o PVC PIPE VENT Y3 ' INVERTER(S) 0 METAL PIPE VENT D ALL el 22 T-VENTAC 2-9... 2(1). 1(G). AC DISCONNECTS) CP SATELLITE DISH 0 DC DISCONNECT(S) FIRE SETBACKS 0.8(b)]. CB IQ COMBINER BOX ,i HARDSCAPE L-......1- I2(B)(2). -PL- PROPERTY LINE NDARY ARE I- -1 INTERIOR EQUIPMENT JN INITIATION L_ _I SHOWN AS DASHED SCALE: NTS A AMPERE SUAfUA AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH #180120 COMP COMPOSITION DC DIRECT CURRENT EXISTING 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 PHONE 0 (E) FAx o ESS ENERGY STORAGE SYSTEM CUSTOMER RESIDENCE: INM EXT EXTERIOR JULIE SHIGEKUNI A INTERIOR MAG MAGNETIC 17 STATION AVE,YARMOUTH, MSP MAIN SERVICE PANEL MA,02664 (N) NEW NTS NOT TO SCALE TEL.(917)771 4531 OC ON CENTER YARM71-4531 000038 PREFAB PRE-FABRICATED NUMBER: PSF POUNDS PER SQUARE FOOT PROJECT NUM SHIG PV PHOTOVOLTAIC 223R-01 (415)580-6920 ex3 RSD RAPID SHUTDOWN DEVICE DESIGNER: TL TRANSFORMERLESS JOSHUA LYONS TYP TYPICAL V VOLTS SHEET W WATTS COVER SHEET REV NAME DATE COMMENTS 11111111111111111111111111 REV:Al 6/30/2022 1111111111111111111111MPAGE Pv_1 ,Q ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SQFT) 4' AR-01 35° 329° 343° 144.9 e� ° AR-02 35° 149° 163° 108.6 A' AR-03 34° 149° 163° 217.3 a , AR-04 42° 149° 163° 362.1 ° r_ of ` /' a ° 4 % [—Cy ° � � / PM rog ♦ /og AC / A` \ -74.t I #sx. • .0• to sunrun S0131k)9\-#8\-- (N)ARRAY AR-03 - #180120 695 MYLES STANDISH BLVD.TAUNTON,MA,02790-7331 PHONED FAX 0 Q" CUSTOMER RESIDENCE: JULIE SHIGEKUNI 17 STATION AVE,YARMOUTH, MA, 02664 0-\___ TEL.(917)771-4531 APN:YARM-000061-000038 (N)CONDUIT RUN PROJECT NUMBER: (ENTRENCHED-60 FT) 223R-017SHIG DESIGNER: (415)580-6920 ex3 rC T C-1 JOSHUA LYONS --��E-^]J SHEET SITE PLAN REV:Al 6/30/2022 PAGE PV_2.O ATTACHMENT INFORMATION DESIGN CRITERIA Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF OC Spacing Overhang OC Spacing Overhang SNOW LOAD: 30 PSF WIND SPEED: TRACK ON 4'-8" 1'- 10" 2'-4" 1'-2" STAGGERED 140 MPH 3-SEC GUST. )C-00436 S.S.LAG SCREWS: ON COMP,SEE4'-8" 1'- 10" 2'-4" 1'-2" STAGGERED 5/16": 2.5" MIN EMBEDMENT 6 STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY ON COMP,SEE 4'-8" 1'- 10" 2'-4" 1'-2" STAGGERED ENGINEER OF ANY POTENTIAL 6 STRUCTURAL ISSUES ON COMP,SEE -4" 2'- 1" 2'-8" 1'-4" STAGGERED OBSERVED PRIOR TO 6 PROCEEDING W/ INSTALLATION. 3/16"= 1-0" • IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE 7" rr 11" EDGES (EXCEPT VALLEYS), 22'-4" k1k THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG I-6" REDUCED WITHIN THE 12" O I BOUNDARY REGION ONLY AS FOLLOWS: —4'-8"TYP 1 •• ALLOWABLE ATTACHMENT SPACING INDICATED ON C) I o C) fl a C7 6'-7" PLANS TO BE REDUCED BY 1 50% •• ALLOWABLE OVERHANG O INDICATED ON PLANS TO BE C) C) C) C) 1/5TH OF ALLOWABLE ATTACHMENT SPACING 2'-7" INDICATED ON PLANS sunrun :: 1/8"= 1-0" #180120 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 PHONED FAX 0 CUSTOMER RESIDENCE: I: invi JULIE SHIGEKUNI Mili: _ APN:MI 17 STATION AVE.YARMOUTH, MA,02664 5'-4"TYP. - _ TEL.(917)771-4531 _ YARM 000061-000038 NMI. PROJECT NUMBER: STRUCT :.` 223R-017SHIG ONLFA�jH SS 415 580-6920 ex3 ( oFM4 DESIGNER: ( )VINCENT s� JOSHUA LYONS MWUMVANEZACIVIL SHEET LAYOUT . •/• ERF N.: '- 'ter ONAIE�G`� REV:Al 6/30/2022 L Z-5" PAGE PV-3.0 (N)HEAVY DUTY SAFETY SWITCH DC DISCONNECT JUNCTION BOX PV MODULES 2t 2a OR EQUIVALENT 1a JA SOLAR:JAM60S17-325/MR / (10)MODULES + $// OPTIMIZERS WIRED IN: (1)SERIES OF(10)OPTIMIZERS LOGIES: SQUARE D �f HU361RB SOLAREDGE POWER OPTIMIZERS TERING 3R,30A,600VDC P370 (N)HEAVY DUTY SAFETY SWITCH DC DISCONNECT JUNCTION BOX PV MODULES 2t oR EQUIVALENT 1a JA SOLAR:JAM60S17-325/MR 2a // (10)MODULES / OPTIMIZERS WIRED IN: ONNECT (1)SERIES OF(10)OPTIMIZERS JTDOWN SQUARE DL )LOGIES: HU361RB SOLAREDGE POWER OPTIMIZERS 3R,30A,600VDC P370 TERING JUNCTION BOX PV MODULES 2b OR EQUIVALENT 9 JA SOLAR:JAM60S17-325/MR / (26)MODULES + // OPTIMIZERS WIRED IN: - (1)SERIES OF(12)OPTIMIZERS --- I I (1)SERIES OF(14)OPTIMIZERS UUTDOONNECT WN L SOLAREDGE POWER OPTIMIZERS TDOWN P370 sunrun #180120 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 PHONE 0 FAX 0 CUSTOMER RESIDENCE: JULIE SHIGEKUNI 17 STATION AVE,YARMOUTH, MA,02664 TEL.(917)771-4531 APN:YARM-000061-000038 PROJECT NUMBER: 223R-017SHIG DESIGNER: (415)580-6920 ex3 JOSHUA LYONS SHEET ELECTRICAL REV:Al 6/30/2022 PAGE PV-4.0 TOVO LTAIC NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE ISCONNECT WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ECT •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT FC.60.11.3 IFC 605.11.1.4 NEC INVOLVED. ,90.13(8)&NEC 690.14C.2.) •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. •DO NOT COVER EXISTING MANUFACTURER LABELS. •HOTOVOLTAIC DC DISCONNECT SYSTEM VOLTAGE: 480 VDC \TION: i),DC DISCONNECT(S). S):NEC 2020:690.53 CAUTIONS ■ MULTIPLE SOURCES OF POWER - SOLAR PANELS ON ROOF A sunrun SIN PANEL DC DISCONNECT #180120 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 PHONE 0 SERVICE II 'II I FAX FAX 0 ENTRANCE CUSTOMER RESIDENCE: 1.11__ � JULIE SHIGEKUNI •'T 17 STATION AVE,YARMOUTH, AC -- SMART L PV LOAD MA, 02664 ISCONNECT METER CENTER TEL.(917)771-4531 APN:YARM-000061-000038 L INVERTERS PROJECT NUMBER: (EXT) 223R-017SHIG DESIGNER: (415)580-6920 ex3 17 STATION AVE, YARMOUTH, MA, 02664 JOSHUA LYONS SHEET SIGNAGE PER CODE(S):NEC 2020:705.10,710.10 REV:Al 6/30/2022 PAGE PV-5.0 SCOPE OF WORK GENERAL NOTES •SYSTEM SIZE: 14950W DC, 12000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780(2015 I • MODULES: (46)JA SOLAR: JAM60S17-325/MR MUNICIPAL CODE,AND ALL MANUFACTURERS' LISTINGS AN[ • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. SE6000H-USSN, (1) SOLAREDGE TECHNOLOGIES: • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE6000H-USSN •RACKING: SNAPNRACK RLU; RL UNIVERSAL, SPEEDSEAL • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NE TRACK ON COMP, SEE DETAIL SNR-DC-00436 •TRENCHING REQUIRED: DC WIRE TO BE TRENCHED 60 FT • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTO IN DIRT MATERIAL. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690 • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. •SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TY MODULES,ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 69 •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 69 •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRE • 10.23 AMPS MODULE SHORT CIRCUIT CURRENT. • 15.98 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)& • PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 6! CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BC LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTD( VICINITY MAP 17 Station Ave, Yarmouth,MA 02664 '9land4ye J` . pit ; ;ith 4 Z cn P Family Table -- Coilaboratr:-e 33 Bass Ri r r,irr SITE PLAN -SCALE=1/16"=1'-0" L SNI (E) RESIDENCE —\ (N)ARRAY AR-01 (N)ARRAY AR-02 Q` WM 0 c L 0, D (E) GATE °a a 2 4 6 t L Q� d G V G r \ C U C • (N)ARRAY AR-04 ----\ 4 y a 4 4 ad. n a \ 4 QA- d \ d `d '6 a 4.(E) DETACHED L a L \ d STRUCTURE c L L a G Q- c ' ° c e 400110 2 c'N' A \ Q a 4 d a \ 'l 1♦ ♦11011.♦ < \ ( N \ A' \ N \ QA' A0 ROOF INFO FRAMING INFO Name Type Height Type Max OC Detail Span Spacing AR-01 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 8'-6" 28" RL UNIVERSAL, SPEEDS/COMP, SEE DETAIL SN AR-02 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 8'-6" 28" RL UNIVERSAL,SPEEDSEAL TR/ DETAIL SNR-DC-C AR-03 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 6'- 10" 28" RL UNIVERSAL,SPEEDSEAL TR) DETAIL SNR-DC-C AR-04 COMP SHINGLE-RLU 1-Story TRUE CUT 2X6 RAFTERS 14'-2" 32" RL UNIVERSAL,SPEEDSEAL TRb DETAIL SNR-DC-( D1 -AR-01 -SCALE: 3/16"= 1'-0" D2-AR-02-SCA AZIM:329° AZIM:149° PITCH: 35° PITCH: 35° 1'-6" } 3'-3" 3'-3" 3._3., 0 0 0 ❑I 0 0 -4'-8"TYP 0 0 a 0 0 0 0 6'-7" 5'-11 I H O O O O O 6" J— 6" 1 i .1-,, 22'-4" L10" -7" D3-AR-03-SCALE: 3/16"= 1'-0" D4-AR-04-SCAI AZIM:149° AZIM:149° PITCH: 34° PITCH: 34° 4'-3" ' 1'-6" 0 ❑ ❑ 0 0 0 ❑ -4'-8"TYP—' ❑ 0 0 ❑ 0 0 - 16'-7" 9'-11" ❑ ❑ ❑ 0 0 0 O O O O O O • 1-5"-4—. 22'4" „,--,_ L8" 9"_ t—'I 6" -1'-6" - SEE SITE PLAN FOR NORTH ARROW 120/240 VAC SINGLE PHASE SOLAREDGE TECI SERVICE NOTE:TOTAL PV BACKFEED=63A SE6000H-USSN WI METER#: USED FOR INTERCONNECTION REVENUE GRADE < (-_—_) EVERSOURCE 2288083 CALCULATIONS 6000 WATT INVER UTILITY GRID ___— `r SUPPLY SIDE TAP (N)100A PV LOAD LOAD RATED DC C CENTER WITH AFCI,RAPID COMPLIANT C I EXISTING 200A (N)LOCKABLEBLADE TYPE (N)MA SMART SOLAREDGE TECI MAIN BREAKER FUSED AC UTILITY SE6000H-USSN WI 1 — DISCONNECT REVENUE REVENUE GRADE METER 6000 WATT INVER' EXISTING Q o Q < 200A MAIN ci----a=o-• O — i ./'` _ .__. PANEL FACILITY '--- 70A FUSES LOADS GROUT D SQUARE D 240V METER SOCKET 35A BREAKER(A) LOAD RATED DC D D223NRB 100A CONTINUOUS 35A BREAKER(B) WITH AFCI,RAPID: 3R, 100A UTILITY SIDE OF CIRCUIT COMPLIANT 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND la NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER lb NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2a 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 2b 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 1"SCH 40 PVC 2T (BELOW GROUND) (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 1"SCH 80 PVC (ABOVE GROUND) 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)4 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 5 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 MODULE CHARACTERISTICS P370 OPTIMIZER CHARACTERISTICS: JA SOLAR:JAM60S17-325/MR: 325 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.87 V MAX INPUT VOLTAGE: 60 VDC MAX POWER VOLTAGE: 33.97 V MAX INPUT TSC: 11 ADC SHORT CIRCUIT CURRENT: 10.23 A MAX OUTPUT CURRENT: 15 ADC SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM CHARACTERISTICS-INVERTER 2 SYSTEM SIZE: 6500 W SYSTEM SIZE: 8450 W SYSTEM OPEN CIRCUIT VOLTAGE: 10 V SYSTEM OPEN CIRCUIT VOLTAGE: 14 V SYSTEM OPERATING VOLTAGE: 380 V SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 17.11 A SYSTEM OPERATING CURRENT: 22.24 A SYSTEM SHORT CIRCUIT CURRENT: 30 A SYSTEM SHORT CIRCUIT CURRENT: 30 A INVERTER 1 P ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE: 480 VDC TERMINALS ON LINE AND LOAD DC SIDES MAY BE ENERGIZED IN LABEL LOCATION: LABEL LO, THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). DC DISCO PER CODE(S):NEC 2020:690.53 (PER COD LABEL LOCATION: 690.15,NE INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL(IPER ODE S):NEC 2020E 901AP13B)(CABLE). WARNING: PHOTOVOLTAIC INVERTEf POWER SOURCE LABEL LOCATION: MAXIM INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. LABEL L( PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: INVERTE DUAL POWER SUPPLY 605.11.1.4 PER COC SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SWITCH POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018: 1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: 4 705.12(8)(3)(2) UippD PHOTOVOLTAIC SYSTEM COMBINER PANELimnit o DO NOT ADD LOADS LABEL LOCATION: PHOTOVOLTAIC AC COMBINER(IF APPLICABLE). 3" TURN RAPID SHUTDOWN PERERCODE(S):NEC 2020:705.12(D)(2)(3)(c) SWITCH TO THE"OFF" SOLAR ELECTRIC IMPANELS POSITION TO SHUT DOWN PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE MAXIMUM AC OPERATING CURRENT: 50.00 AMPS SHOCK HAZARD IN THE ARRAY. ■ NOMINAL OPERATING AC VOLTAGE: 240 VAC LABEL LOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S):NEC 2020:690.56(C) 1 1 =T EV projects@evengineersnet.com 276-220-0064 lima ENGINEERS http://www.evengineersnet.com 30/06/2022 RE:Structural Certification for Installation of Residential Solar JULIE SHIGEKUNI:17 STATION AVE,YARMOUTH,MA,02664 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 32 inches.The slope of the roof was approximated to be 42 degrees. After review of the field observation data and based on our structural capacity calculation,the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install.Should they find any discrepancies,a written approval from SEOR is mandatory before proceeding with install.Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT . . ONL Sincerely, sii 0 OFMgSSgC' O� 9 VINCENT "N Vincent Mwumvaneza, P.E. 0 MWUMVANEZA N EV Engineering, LLC NICIVIL � projects@evengineersnet.com °q;:. Ecco c,�� http://www.evengineersnet.com '• /0NAlOC.1 1/1 =- EV projects@evengineersnet.com 276-220-0064 MINIM ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 30/06/2022 Job Address: 17STA"tIONME YARMOUTH,M1,J0 0 1- Job Name: JUU E:.SHI6EKVNI Job Number: 22063015 Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 20/5 IRC(ASCE 7-10)-CMR 7869th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V 140 mph Exposure C References NDS for Wood Construction STRUCT C , ONL ���`tNOFMgSSA O cy Sincerely, 4' VINCENT aN o MWUMVANEZA CIVIL N Vincent Mwumvaneza, P.E. .N� EV Engineering, LLC : - EV projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed (3s gust),V= ,` 0;'mph ASCE 7-10 Figure 26.5-1A Roughness= C ASCE 7-10 Sec 26.7.2 Exposure= C ASCE 7-10 Sec 26.7.3 Topographic Factor, KZT= 1.00 ASCE 7-10 Sec 26.8.2 Pitch= 410-Degrees Adjustment Factor,A= 1.21 ASCE 7-10 Figure 30.5-1 a= 3.20 ft ASCE 7-10 Figure 30.5-1 Where a:10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -35.3 -35.3 Figure 30.5-1 Pnet=0.6 x X x KZT x Pnet30)= 21.29 25.64 25.64 Equation 30.5-1 Downpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 32.1 32.1 32.1 Figure 30.5-1 Pnet=0.6 x X x KZT x Pnet30)= 23.28 23.28 23.28 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing= 5.3 ft 205 lbs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(lbs) Down(lbs) 1 5.3 14.6 284.0 383.1 2 5.3 14.6 347.4 383.1 3 3 8.3 196.7 216.8 Max= 347.4 < 512.5 CONNECTION 15 OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 mom V EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Pg= 30 psf ASCE 7-10,Section 7.2 pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 pfmin.= 25.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 p5= 25 psf 31.1 plf Is= 1.0 ASCE 7-10,Table 1.5-1 CS 0.467 Max Length, L= 14.17 ft Tributary Width,WT= 32 in Dr= 10 psf 26.67 plf PvDL= 3 psf 8 plf Load Case:DL+0.6W Pnet+PPvcos(8)+Pot= 96.8 plf Max Moment, Mu= 1192 lb-ft Conservatively Pv max Shear 383.1 lbs Max Shear,V„=wL/2+Pv Point Load = 629 lbs Load Case:DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+PP„cos(8)+PDL= 103 plf MdoWn= 1263 lb-ft Mallowable=Sx x Fb' (wind)= 2093 lb-ft > 1263 lb-ft OK Load Case:DL+S Ps+PPVcos(8)+PDL= 64 plf MdoWn= 785 lb-ft Mallowable=Sx x Fb' (wind)= 1504 lb-ft > 785 lb-ft OK Max Shear,V„=wL/2+Pv Point Load = 726 lbs Member Capacity Design Value CL CF C; Cr Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi F„= 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth,d= 6 in Width, b= 2 in Cross-Sectonal Area,A= 12 in2 Moment of Inertia, In= 36 in4 Section Modulus,Sx.= 12 in3 Allowable Moment, Mail=Fb'SXx= 1308.1 lb-ft DCR=M„/Mali= 0.57 < 1 Satisfactory Allowable Shear,Vail=2/3Fv'A= 1080.0 lb DCR=Vu/Vaii= 0.67 < 1 Satisfactory 1/1 mmink v EV projects@evengineersnet.com 276-220-0064 vk ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 42% Dpv and Racking 3 psf Averarage Total Dead Load 11.2 psf Increase in Dead Load 5.0% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans- JULIE SHIGEKUNI.The analysis was according to applicable building codes, professional engineering and design experience,opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1