HomeMy WebLinkAboutBLDE-23-000554 eVe Commonwealth of Official Use Only E Massachusetts Permit No. BLDE-23-000554 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked IRev.1/071 APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:8/3/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 30 WARBLER LN Owner or Tenant ANDERSON MARIE GRACE Telephone No. Owner's Address 30 WARBLER LN,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(22 Panels 8.80 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. ,I 000tal n No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water K y No.of No.of Ballasts Data Wiring: Heaters Signs No,of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: BRIAN K MACPHERSON Licensee: Brian K Macpherson Signature LIC.NO.: 21233 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:32 GROVE ST,DBA TRINITY SOLAR,PLYMPTON MA 023671306 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature (' — - Te lephone No. PERMIT FEE:$150.00 ix g , FT---, i: --7:77i,„„7-7747.-.71 3 1 permits.wareham@trinity-solar.com AU't 6 �,, 20 �. Commonwealth o/ft/aadachaJetfa Qf�cial Use On� `. _;It [t 2 `� . Permit No. �lJ2J 59-f -- r• eParfinenf o ire Serviced BUILDING DEPA �Y ------ ;: ;I;I 3 Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. I/07 ;��t ) (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to he performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 07/29/2022 City or Town of: Yarmouth, MA To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 30 Warbler Lane, Yarmouth, MA Owner or Tenant Marie Anderson Telephone No.(240) 372-3504 Owner's Address 30 Warbler Lane. Yarmouth. MA Is this permit in conjunction with a building permit? Yes C No n (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps 120 / 240 Volts Overhead❑ Undgrd❑ No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd n No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install 8.80 kw solar panels on roof. Will not exceed roof panel. but will add 6"to roof height. 22 total panels. Completion of the followingtable may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.ofTot Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above In- No.of Emergency Lighting No.of Luminaires Swimming Pool grnd e ❑ grnd. ❑ Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones `No.of Detection and No.of Switches No.of Gas Burners Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of WaterKWNo.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring No.of Devices or Equivalent OTHER: 22 total panels Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 43,000 (When required by municipal policy.) Work to Start: TBD Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this app ,, 'on is true and complete. FIRM NAME: Trinity Solar Inc LIC.NO.: 4434A1 Licensee: Brian MacPherson Signature Z.," 4,. LIC.NO.: 21233A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.•508-291-0007 Address: 32 Grove St.Plymoton,MA 02367 Alt.Tel.No.: 774-271-1858 *Per M.G.L.c. 147,s.57-61,security work requires Department of Pub! afety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner ❑owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE:$ • c INSTALLATION OF NEW WARBLER LANE. • ROOF MOUNTED PV SOLAR SYSTEM 30 WARBLER LANE YARMOUTH, MA 02673 Issued 2 Revisions PI ISS11.10POPMSIIIP FOP Nrr ` CIVICINITY MAP SITE NO, DESCRIPTION DATE SCALE:NTS Project Title: ANDERSON,MARIE- TRINITY ACCT M:2022-06-714669 Project Address: 30 WARBLER LANE YARMOUTH,MA 02673 41.6755649,-70.2208053 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX 1.THE INSTALLATION CONTRACTOR IS B. THE DC VOLTAGE FROM THE PANELS IS 14 BI CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/SITE INFO&NOTES 'Drawing Title: RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLTAMPERE PV-2ROOF PLAN W/MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILOWATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF LWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE 2 THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE MCB MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MDP MAIN DISTRIBUTION PANEL EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALL MLO MAIN LUG ONLY DRAWING OATS: 7/15/2022 DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT, SYSTEM COMPONENTS AS DESCRIBED IN MTD MOUNTED DRAWN BY: MS IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. MTG MOUNTING 3.THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE 16 ALL INFORMATION SHOWN MUST BE N NEUTRAL REVISED BM, RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTIVITIES. NIC NOT IN CONTRACT COMPONENT AND INVERTER MANUALS ARTICLE 6908705. NO It NUMBER System Information: PRIOR TO INSTALLATION.THE INSTALLATION ID. PRIOR TO THE INSTALLATION OF THIS NTS NOT TO SCALE OC SYSTEM SIZE. B.BkW CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE ABBREVIATIONS OCP OVER CURRENT PROTECTION AC SYSTEM SIZE: 7.65W ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL ION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AMP AMPERE PB PULL BOX MODULE COUNT: 22 THEINSTALLATION NSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT PH 0 PHASE MODULES USED: HANWHA 900 SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND AL ALUMINUM PVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC 11 O.PUK DUO MA 51lG109•400 4.ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AF AMP.FRAME PMR POWER EVERSOURCE MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR OTY QUANTITY UTILITY COMPANv:.1430745002 CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL UTILITY ACCT 0: 2 28 9683002 6 ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SN SOLID NEUTRAL UTILITY METER A: 2289669 SOLAR PHOTOVOLTAIC INSTALIATON HARDWARE CHECKS AND DC WIRING C CONDUIT(GENERIC TERM OF JBWBO SWRCHBOARO DEAL TYPE: SUNNOVA COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY.PROVIDE AS TYP TYPICAL 5.FOR SAFETY,IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND SPECIFIED U.O.I. UNLESS OTHERWISE INDICATED THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX WP WEATHERPROOF MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT CIRCUIT XFOR TRANSFORMER Rev.No. Sheet TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER •72 MOUNT 72 INCHES TO BOTTOM INSTALLATION CREW MEMBERS RE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC CU COPPER OF ABOVE FINISHED FLOOR OR IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DC DIRECT CURRENT GRADE ^ 6.THIS SOLAR PHOTOVOLTAIC SYSTEM 15 TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH Y I . BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING CONVENTIONS OF THE NATIONAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER ELECTRICAL CODE.ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND EMT ELECTRICAL METALLIC TUBING WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE FS FUSIBLE SWITCH GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL FU FUSE 7.ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH GND GROUND INSTALLED WITH THIS SYSTEM ARE TO BE N CURRENT PREVAILING MUNICIPAL GFI GROUND FAULT INTERRUPTER 'UL"LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY(CYCLES PER 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND GENERAL NOTES SOLAR IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN NV,PLEASE BE ADVISED THAT FINAL EQUIPMENT ANDIOR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2213 Allenwood R440 877086-7283 Wall,New Jersey 07719 www:INT,IH-Solar.corn I • NOTES.'REFER TO MODULE SPECS FOR MODULE DIMENSIONS \ 'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP NEW PV SOLAR MODULE,TYPICAL (REFER',SPEC Miff/FOR DETAILS, (REFER TO EWIPMENT SCMEWLE FOR SPE;741:,,,D OIWNTITIES) I SOLAR MODULE SOLAR MODULE W MOG FOOT(Ai TE; NM �� POINTS. (REFER TO ECOFASTEN"L'FOOT ECOFASTEN RAIL \H 90 Ilili rvfwFgsRATO BUNTPEPINDICULAA TO STR1LE EXISTINTITS ECOFABTENFLASHN4G� (NEW END CLP.TVPIGL 1•=1111M11•1•1111 IIISIIMIIISIMMIIMII B.S.LAG BOLT APOC SEALANTilk /, 0: �.,\ (REFER TOECOFASTEN TAILS)SPECIFICATION IREEERTO ENONEEBS LETTFRFORSPEW . SOLAR MODULES SHALL NOT /V �� �� /DATA SHEET FOR DETAILS) vEEEV To LING RAFTER R EXCEED PEAK HEIGHT. NEW MID CLP.TYPICAL o ErRO1 EEnS(ErTEq FO AAE, (REFER TO ECOFASTEN SPECIFICATION I DATA SHEET FOR DETAILS) ❑ ATTACHMENT&CLIP DETAIL OPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT OT FROMTO GROUNDSCALE LEVEL TO PEAK OF ROOF SCALE'.NOT TO SCALE SCALE'NOT TO SCALE S ARRAY SCHEDULE Issued/Revisions BACK II AMP TO MAAR.FOP FFRAIIT AIT/FroF NO. DESCRIPTION DATE Project Title: -- ANDERSON,MARIE- -----______ _ _ R TRINITY ACCT R:2022-06-714669 BACK ® Project Address: 30 ER LANE — r Y • ® YARMOUTH,MA 02673 IIIMIIMAI ® R 111 • 1111111 41.6755649,-70.2208053 FRONT IS 111111 111111111111 Drawing Title: PROPOSED PV SOLAR SYSTEM I _ CIm Drawing Information ROOF 1 '©m� ) ® ® DRAWING DATE: 7/15/2022 (PROPERTY UNE I --�-- PRO(:MODULES:22 ---� 30L____________ ____T ORIENTATION:02 wx v. MS ROOF 2 ® REVISED By: 71 MODULES:, System Information: PITCH.30' ORIENATION,262' I ' Ys DC SYSTEM SIZE'. 8 8kW ROOF 3 AC SYSTEM 512E: 7.6kW ORIEN 30 ORIENTATION 262' MODULE COUNT. •22 ROOF 4 MODULES USED: HANWOA400 MODULES:, FRONT MODULE SPEC OK ,.PEAK DUO BIK ML-0109+400 ORIEN TAT3PION:352° UTILITY COMPANY:•EVERSOURCE Ofl1EN ROOF 5 UTILITY ACR p: 14307410026 MODULES:O NOTES: UTILITY METER k: '220%04 OIRIEN 30° ORIENTATION:172' 1.1 EQUIPMENT TEASIULLBE'S INSTALLATONACCORDANCERUCD DEAL LTE'. SUNNOVA ROOF 6 WITH THE MANUFACTURER'S RD PWIT MANUFACTURER C URER SPECIF ONS PITCH 35:0 2.)ARRAY LOCATIONS ROE COMPLYPROWITH MNREQUIRE RE ISPEVIE(CACION. ATI ORIENTATION: 30' 3)ALL LOCATIONS ECT SHALLMIIMTE AND REQUIRE FIELD VERIFICATION. • ORIENTATIDN:SJY 4)AN AC DISCONNECT BE GROUPED WITH INVERTER(S)NEC 690.13(E) Rev.No. Sheet ROOF 7 5)ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. MODULES:, 6)ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. PITH 23' P 1 PV - ORIENTATION.82' ROOFS SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE MODULES:, • OTT SPECS PITCH.23' INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE INDICATES NEW PV ONLY SUBPANEL ORIENTATION.262' ® ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE(UTILITY ACCESSIBLE) SP TO BE INSTALLED 22 HANWHA 4001Q.PEAK DUO BLK ML-G10.8+400) ROOFS -_ MODULES:D INDICATES NEW PV SOUR MODULE.rtEG MOWLES 1 SE7600H-USOSHBNC4 PITCH 38' ORIENTATION:262' (M( INDICATES EXISTING METER LOCATION REFERLi TE PANELS THAT USE MICRO INVERTERS. DC INDICATES NEW DC DISCONNECT • ROOF 1D ��..JJ TO EQUIPMENT SCHEDULE FOR SPECS. MOH:NA'NA • - -- --,�, - - -_ - -- - •OTHER OBSTRUCTIONS PI ELiEi' EP LCCATION'EBASEMENELECTRICAL PANEL )p I INSTALLED TOUTSIDE.ODUCTION METER TO BE SD INDICATES EXISTING SERVICE DISCONNECT ORIENTATION'.NA' 11 II ROOF 11 SOLAR MODULES:° _. __ .. —. - -. • PITCH.30' INDICATES NEW FUSED PV DISCONNECT TO BE INDICATES OUTNEW SIDE. TO BE 2211 Allenwood Road 872-786-2283 ORIENTATION.352' O INSTALLEDOUTSIUEIUTILITYACCESSIBLE( ® INBTAl1E000TSIDE. TS INDICATES EXISTING TRANSFER SWITCH REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey 07719 wwwT unity.SPlar.CDm Engineer/License Holder ARRAY CIRCUIT WIRING NOTES 1.)LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH SOLAR MODULES MOUNTED TO ROOF ON 1 ARRAY NEC 2020 22-400W MODULES W/1 SOLAR EDGE 5440 PER MODULE 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON 15 ADC MAX PER STRING ASHRAE MINIMUM MEAN EXTREME DRY BULB _ TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO 2 STRINGS OF 11 MODULES IN SERIES•400 WTI. JUNCTION INSTALLATION LOCATION.LOWEST EXPECTED AMBIENT �� ROB TEMP=-1St '2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2%DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION.HIGHEST CONTINUOUS TEMP= 33'C 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN EXISTING ryEW EXISTING TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED MAIN BREAKER LOAD CENTER EXISTING TAP BOX 1UTILIYV LITY STATES(PALM SPRINGS,CA 1544.1'C).FOR LESS THAN 9 10 240V GENERATOR INSULATED LINE METER CURRENT-CARRYING CONDUCTORS IN A ROOF.MOUNTEO 10DA MAIN BREAKER ID TAPS TO BE SUNLIT CONDUIT AT LEAST OS'ABOVE ROOF AND USING 100A BUSBAR EXISTING TRANSFER GENERATOR O INSTALLED ON Issued/Revisions THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS -- SWITCH MAIN FEEDERS (ALL OF UNITED STATES) II NEC 705.12(A) S.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I---t-.1 CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I ^- = - a0.. - •I isuxOTammsxlr�nlRMIT u.valll NEC 690.12(A)THROUGH(D) ...�L.. T 17 2P100A _ NO. DESCRIPTION DATE 6.I PHOTOVOLTAIC POWER SYSTEMS SHALL RE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC I I Project Title: SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(M(4 ].)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE ANDERSON,MARIE- IDENTIFIEDWITHTHEFOLLOWINGOUTERFINISH. POSITIVE CONDUCTORS=RED TRINITY ACCT X:2022-06-714669 NEGATIVE CONDUCTORS=BLACK - ,(r NEC 210.5(C)(2) .3 r- Project Address: 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE 010 PV o a oNOTE: V. WIRE TYPE RAW.?OR EQUIVELANT AND SHALL BE = r----{L. L INTERNAL REVENUE GRADE MONITORING 30 WARBLER LANE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT CONTAINED WITHIN SOLAR EDGE INVERTER SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL EXISTING SOLAR EDGE PN.R W ND-3D-240-MB YARMOUTH,MA 02673 CONTAIN 5 20 CURRENT CARVING CONDUCTORS AND MAIN BREAKER LOAD CENTER 41.6755649,-70.2208053 WHERE EXPOSED TO DIRECT SUNLIGHT SHALL J CONTAIN 59 CURRENT CARRYING CONDUCTORS. r 9.1 ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS DreWing Title: OTHERWISE NOTED 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON LOCKABLE 60A DISCONNECT <"_IPI'sPROPOSED PV SOLAR SYSTEM ROOFTOP AND SHALL BE LIMITED TO 12'IF USED FUSED W/40A FUSES OUTDOORS 240V 10 INVERTER pl 11.)OVERCURRENT PROTECTION FOR CONDUCTORS leeeeye 1 .2-=o. J `/T� Drawing Information CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE �I5 }-i DRAWING DATE: 7/15/2022 LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC 7,.....-5 d'� ! 690.91A1(3)(2) DRAWN RH: M5 _ �� (�j JJ REVISED BY: 12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE A f-_ lL / �J� -J UTILITY AND THE OTHER AN INVERTER,PV RACKFEED G _�e[T Ll L2 N 1 r NEC 70 BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY 'le n m e a I` --I 0 B BJ .'(',d I System Information: NEC 705.12(8)(3)(2) I I DC SYSTEM SNE: 88kW SQUARED I LZ .4 AC SYSTEM SIZE. 7.6kW 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY PN:D222NRB GENERATION CIRCUITS AND NO UNUSED POSITIONS OR L- J MODULE COUNT: 22 LOADS MODULES USED. HANWAO 400 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE MODULE SPEC p'. p.PEAK DUO BLk Ml41O.0�400 A NEMA 3R RATINGUTILITY COMPANY EVERSOURCE UTILITY ACCs R. 14307430026 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER 0: 22119684 REQUIRED CONOUCTOR AMPALI IV PER SIRING INK 690.8(0)(1)1:(15.00'1.25)1=18.75A DEAL TYPE: SUNNOVA PV MODULE SPECIFICATIONS AWG 030,DERATED AMPACITY HANWHA400(C1 PEAK DUO BLKML-U10.a*400) Rev.NO. Sheet AMBIENT TEMP:33-C,TEMP DERATING FACTOR:.96 RACEWAY DERATING=4 CCC:O.RO Imp 10.77 T !LAC'ul� (40'.96)0-80=30.72A Vmp 47.33 T .LIH.E, U[Ic l�r u .IL3 .ON D 30.72A'18.7SA,THEREFORE WIRE SIZE IS VALID Voc 45.3 A 46 THWN-2 GEC TO EXISTING GROUND ROD P1 PV - 3 TOTAL AC REQUIRED CONDUCTOR AMPACITY lac 1114 B 3/4.CONDUIT W/2-08 THWN-2,1-010 THWN-2.1410 THWN-2 GROUND 32.0061.25=40.00A C 3/4"CONDUIT W/4-030 THWN-2,1410THWN-2 GROUND AWG 48,DEBATED AMPACITY INVERTER X1-SE76001.1-USOSHBNC4 AMBIENT TEMP:30C,TEMP DERATING:1.0 D 3/4"CONDUIT WI 4-410 THWN-2,1-41DTHWN-2 GROUND RACEWAY DERATING`3 CCC:N/A DC AC • SSA'1.0=SSA Imp 20 Pout 7600 1 3/4"CONDUIT WI 2-ID THWN,,1310 THWN.2,1410THWN-2 GROUND SSA 40.00A,THEREFORE AC WIRE SIZE IS VALID Vmp 400 !max 32 Vo[ 480 OCPDmin 40 F 410 PV WIRE IFREE/WOW/06 BARE COPPER BOND TO ARRAY SOLAR CALCULATION FOR PN OVERCURRENT PROTECTION G 3/4"CONDUIT WI 2-06 THWN-2.1'06THWN-2,1.08THWN-2 GROUND TOTAL INVERTER CURRENT:32.00A lac 30 Vnom 240 32.00A•1,25=40.00A 2211 Allenwood Road 877.786-7283 -040A OVERCURRENI PROTECTION IN VALID Wall,New Jersey 07719 www.Trinity-SXlar.com