Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-22-007238 PLANS
LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION :/IBC/IEBC), r— SOLAR MODULES PV-1.0 COVER SHEET NSTALLATION SE SERVICE ENTRANCE 1 p_ _-_a____ _-_$t__ _ ---0 PV 2.0 SITE PLAN • j MP MAIN PANEL 1 ==_ _- 43`=-�- ---a, PV-3.0 LAYOUT 2020. I n n PV-4.0 ELECTRICAL ____—.___. �________._ — a-1 SNR MOUNT PV-5.0 SIGNAGE 5 ARE SOLIDLY SP SUB-PANEL L-- SNR MOUNT&SKIRT i. - PV LOAD CENTER CHIMNEY SM SUNRUN METER n, ATTIC VENT E I, OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT /l a PVC PIPE VENT ,ND ALL INV INVERTER(S) ® METAL PIPE VENT V� ' , 12(1). 2g T-VENT �� .31(G). AC AC DISCONNECT(S) 0 ° ? SATELLITE DISH T. DC DC DISCONNECT(S) FIRE SETBACKS 190.8(b)]. CB IQ COMBINER BOX k• ' HARDSCAPE . � C.12(B)(2). UNDARY ARE I- -I INTERIOR EQUIPMENT —PL— PROPERTY LINE 1WN INITIATION SHOWN AS DASHED L SCALE: NTS A AMPERE SUflIUfl AC ALTERNATING CURRENT AFC' ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH COMP COMPOSITION #180120 DC DIRECT CURRENT (E) EXISTING 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 ESS ENERGY STORAGE SYSTEM PHONFAX OEO EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC JEAN KENNEALLY MSP MAIN SERVICE PANEL 23 WASHINGTON AVE, (N) NEW YARMOUTH, MA, 02673 NTS NOT TO SCALE OC ON CENTER TEL.(774)368-3613 PRE-FAB PRE-FABRICATED APN:YARM-000063-000009 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC 223R-023KENN RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL V VOLTS CAD IN-N-MBARAKT-DS W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:A 6/1/2022 PAGE PV-1.0 ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SQFT) AR-01 27° 170° 184° 199.2 v -or (E) RESIDENCE 7-4 (E) DETACHED STRUCTURE sunrun #180120 r 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 PHONED FAX 0 CUSTOMER RESIDENCE: JEAN KENNEALLY 23 WASHINGTON AVE, YARMOUTH, MA, 02673 P1.. TEL.(774)368-3613 APN:YARM-000063-000009 PROJECT NUMBER: 223R-023KENN DESIGNER: (415)580-6920 ex3 CAD IN-N-MBARAKT-DS SHEET SITE PLAN REV:A 6/1/2022 PAGE PV-2.O ATTACHMENT INFORMATION DESIGN CRITERIA Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD: 3 PSF OC Spacing Overhang OC Spacing Overhang SNOW LOAD: 30 PSF kL TRACK ON WIND SPEED: :-DC-00436 5'-4" 2'- 1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: 5/16": 2.5" MIN EMBEDMENT STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ STRUCT INSTALLATION. oNL • IF ARRAY(EXCLUDING SKIRT) ��FALSHOFMassgo IS WITHIN 12"BOUNDARY ��� VINCENT y�s�, REGION OF ANY ROOF PLANE c MWUMVANEZA EDGES (EXCEPT VALLEYS), y " CIVIL `� THEN ATTACHMENTS NEED 16'-10" 1 TO BE ADDED AND OVERHANG °yam� • ��o �e REDUCED WITHIN THE 12" •ter ' E ����` BOUNDARY REGION ONLY AS ONALEN FOLLOWS: •• ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% •• ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS sunrun 0 #180120 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 PHONE 0 FAX 0 CUSTOMER RESIDENCE: JEAN KENNEALLY 23 WASHINGTON AVE, YARMOUTH, MA, 02673 TEL.(774)368-3613 APN:YARM-000063-000009 PROJECT NUMBER: 223R-023KENN DESIGNER: (415)580-6920 ex3 CAD IN-N-MBARAKT-DS SHEET LAYOUT REV:A 6/1/2022 PAGE PV-3.0 30X PV MODULES LENT 1 JA SOLAR:JAM60S10-340/MR // (11) MODULES + � / OPTIMIZERS WIRED IN: I' (1) SERIES OF(11)OPTIMIZERS SOLAREDGE POWER OPTIMIZERS P370 sunrun #180120 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 PHONE D FAX 0 CUSTOMER RESIDENCE: JEAN KENNEALLY 23 WASHINGTON AVE, YARMOUTH, MA, 02673 TEL.(774)368-3613 APN:YARM-000063-000009 PROJECT NUMBER: 223R-023KENN DESIGNER: (415)580-6920 ex3 CAD IN-N-MBARAKT-DS SHEET ELECTRICAL REV:A 6/1/2022 PAGE PV-4.0 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. •DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION . MULTIPLE SOURCES OF POWER sunrun (INT) MAIN PANEL #180120 - 695 MYLES STANDISH BLVD,TAUNTON,MA,02780.7331 PHONES FAX 0 - SOLAR PANELS CUSTOMER RESIDENCE: JEAN KENNEALLY ON ROOF 23 WASHINGTON AVE, YARMOUTH, MA, 02673 - INVERTER (EXT) TEL.(774)368-3613 - PV PRODUCTION METER APN:YARM-000063-000009 PROJECT NUMBER: - AC DISCONNECT 223R-023KENN - SERVICE ENTRANCE DESIGNER: (415)580-6920 ex3 CAD IN-N-MBARAKT-DS 23 WASHINGTON AVE, YARMOUTH, MA, 02673 SHEET PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE REV:A 6/1/2022 PAGE PV-5.0 • SCOPE OF WORK GENERAL NOTES •SYSTEM SIZE: 3740W DC, 3800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780(2015 IRS • MODULES: (11)JA SOLAR: JAM60S10-340/MR MUNICIPAL CODE,AND ALL MANUFACTURERS' LISTINGS AND I • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. SE3800H-USMN • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • RACKING: SNAPNRACK RLU; RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTOR GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.3 • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. •SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYF MODULES,ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS F CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690 •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 69C •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURREI' • 10.46 AMPS MODULE SHORT CIRCUIT CURRENT. • 16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8 (a)&I • PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 69 CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BO LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDC VICINITY MAP Orleans ndwich ' 6A • Dennis ip 23 Was Kington Ave, - West Yarmouth,MA.. Chatham lashpee y SITE PLAN-SCALE=3/64"= 1'-0" k SNI WASHINGTON AVE PL PL PL i s PL\------ c. h y t a t r \ \,t « a i G i a «d C r r rey INV PM AC a .00 X61 (N)ARRAY AR-01 -------F---- r pl --------------- PL pL ROOF INFO FRAMING INFO Name Type Height Type Max OC Detail Span Spacing AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-3" 16" RL UNIVERSAL, SPEEDSE COMP, SEE DETAIL SN D1 -AR-01 -SCALE: 3/16"= 1-0" AZIM:170° PITCH: 27° r1-7" 22'-4" 1'-11" ❑ ❑ ❑ 0 ❑ ❑ I 1 0 Il 5'5'-4"4TYP—l3 © Cl 0 9'-11"3'-5" i J ❑ ❑ 0 0 ❑ 0 e I I n n n n 3'-7" C, SEE SITE PLAN FOR NORTH ARROW. 120/240 VAC SINGLE PHASE SERVICE © METER#: NOTE:TOTAL PV BACKFEED=20A < EVERSOURCE 1936766 USED FOR INTERCONNECTION CALCULATIONS UTILITY GRID I 1 EXISTING C 1 100A MAIN BREAKER EXISTING SOLAREDGE TECHNOLOGIES: / 125A (N) MA SMART �� MAIN (N) LOCKABLE UTILITY SE3800H-USMN WITH FACILITY PANEL BLADE TYPE REVENUE REVENUE GRADE METERING AC DISCONNECTMETER 3800 WATT INVERTER JUNCTION LOADS �} T ri) OR EQUIV 0 1 7 J U U (N)20A - FGAR U o SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT PV BREAKER AT DU221RB 100A CONTINUOUS WITH AFCI, RAPID SHUTDOWN OPPOSITE END 3R,30A,2P UTILITY SIDE OF CIRCUIT COMPLIANT OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 MODULE CHARACTERISTICS P370 OPTIMIZER CHARACTERISTICS: JA SOLAR: JAM60S10-340/MR: 340 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 41.55 V MAX INPUT VOLTAGE: 60 VDC MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11 ADC SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 3740 W SYSTEM OPEN CIRCUIT VOLTAGE: 11 V SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 9.84 A SYSTEM SHORT CIRCUIT CURRENT: 15 A INVERTER 1 ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE: 480 VDC TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN LABEL LOCATION: THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). PER CODE(S):NEC 2020:690.53 LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL(IF APPLICABLE). PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES: UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SWITCH POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: _ 4" 705.12(B)(3)(2) SOLAR Kt-SYSTEM UPPED PHOTOVOLTAIC SYSTEM PID SHUTDOWN COMBINER PANEL Wntil DO NOT ADD LOADS LABEL LOCATION: PHOTOVOLTAIC AC COMBINER(IF APPLICABLE). PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN SWITCH TO THE"OFF" SOUR ELECTRIC POSITION TO SHUT DOWN PV PANELS PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE MAXIMUM AC OPERATING CURRENT: 15.83 AMPS SHOCK HAZARD IN THE NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. LABEL LOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S):NEC 2020:690.56(C) � EV projects@evengineersnet.com 276-220-0064 mum ENGINEERS http://www.evengineersnet.com 6/1/2022 RE:Structural Certification for Installation of Residential Solar JEAN KENNEALLY:23 WASHINGTON AVE,YARMOUTH,MA,02673 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 16 inches.The slope of the roof was approximated to be 27 degrees. After review and based on our structural capacity calculation,the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades.Contractor shall verify that existing framing is consistent with the described above before install.Should they find any discrepancies,a written approval from SEOR is mandatory before proceeding with install.Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 140 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. STRUCT OHL Sincerely, AkG,�SN OFMgSSgO o s' VINCENT GP Vincent Mwumvaneza, P.E. o MWUMVANEZA EV Engineering, LLC N1CIVIL projects@evengineersnet.com IP • � E��a http://www.evengineersnet.com .4" oNA0-C4) 1/1 �® EV projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 6/1/2022 Job Address: 23 WASHINGTON AVE YARMOUTH,MA,02673 Job Name: JEAN RENALLY Job Number: 2206011K Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Roof f Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V 140 mph Exposure C References NDS for Wood Construction STRUCT � . ONL �01 Of hlgssg09 Sincerely, 4.4' VINCENT Gt MWUMVANEZA CIVIL Vincent Mwumvaneza, P.E. N�� ;; EV Engineering, LLC � E G\4� projects@evengineersnet.comEN http://www.evengineersnet.com 1/1 ® EV projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed (3s gust),V= 140 mph ASCE 7-10 Figure 26.5-1A Roughness= C ASCE 7-10 Sec 26.7.2 Exposure= C ASCE 7-10 Sec 26.7.3 Topographic Factor, KuT= 1.00 ASCE 7-10 Sec 26.8.2 Pitch= 27.0 Degrees Adjustment Factor,A= 1.35 ASCE 7-10 Figure 30.5-1 a = 2.40 ft ASCE 7-10 Figure 30.5-1 Where a:10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -29.3 -41.3 -65.1 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 23.75 33.46 52.75 Equation 30.5-1 Downpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 15.7 15.7 15.7 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 12.73 12.73 12.73 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing= 5.4 ft 205 lbs/in Lag Screw Penetration 2.5 in Allowable Capacity= 512.5 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(lbs) Down(lbs) 1 5.4 14.9 325.9 233.5 2 5.4 14.9 470.1 233.5 3 2 6.6 336.2 103.8 Max= 470.1 < 512.5 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 mow V EV projects@evengineersnet.com 276-220-0064 Immi ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Pg= 30 psf ASCE 7-10,Section 7.2 Pf= 21 psf Ce= 0.9 ASCE 7-10,Table 7-2 Pfmin.= 25.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 Ps= 25 psf 23.9 plf Is= 1.0 ASCE 7-10,Table 1.5-1 CS 0.717 Max Length,L= 11.25 ft Tributary Width,WT= 16 in Dr= 10 psf 13.33 plf PvDL= 3 psf 4 plf Load Case:DL+0.6W Pnet+Pp„cos(0)+PDt= 34.3 plf Max Moment, Mu= 383 lb-ft Conservatively Pv max Shear 233.5 lbs Max Shear,V„=wL/2+Pv Point Load = 331 lbs Load Case:DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+PP„cos(9)+PDL= 48 plf Mdown= 531 lb-ft Mallowable=Sx x Fb'(wind)= 1319 lb-ft > 531 lb-ft OK Load Case:DL+S Ps+PpVcos(8)+PDL= 41 plf Mdown= 455 lb-ft Mallowable=Sx x Fb' (wind)= 948 Ib-ft > 455 lb-ft OK Max Shear,Vu=wL/2+Pv Point Load= 331 lbs Member Capacity S 2 �� Design Value CL CF C; Cr Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi F„= 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth,d = 5.5 in Width, b= 1.5 in Cross-Sectorial Area,A= 8.25 in2 Moment of Inertia, lx„= 20.7969 in" Section Modulus,Sxx= 7.5625 in' Allowable Moment, Man= Fb'Sxx= 824.4 lb-ft DCR=M„/Mali= 0.46 < 1 Satisfactory Allowable Shear,Vain=2/3F,'A= 742.5 lb DCR=V„/Vali= 0.45 <1 Satisfactory 1/1 liia.T EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 10% Dpv and Racking 3 psf Averarage Total Dead Load 10.3 psf Increase in Dead Load 1.2% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans- JEAN KENNEALLY.The analysis was according to applicable building codes, professional engineering and design experience,opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1