Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-22-006010
,e -, Commonwealth of Official Use Only fen) Massachusetts Permit No. BLDE-22-006010 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:4/20/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 5 WEDGEMERE RD Owner or Tenant David Macary Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(20 Panels 7.1 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above o In- o No.of Emergency Lighting grnd. grnd. ,Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices No.of Waste Disposers Heat Pump Number , Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Eauivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Eauivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties ofperjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 cS /i /zz ke--- /� ®®// �j�/ / RECEIVED � (ommonweaf$h o//�laseachune -.1 Official Us Only " i"' t L APf 19 7Cllmit 14o. E22- I'D e1 2epartment o93ire 80PC LLB i U - e Occuplic and Fee Checked ' BOARD OF FIRE PREVENTION RE 3 p8EP{ r,Afil leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: y -12- City or Town of: Y®rmauth To the Inspector of Wires: By this application the undersigned gives notice of his or her inte I tion to perform the electrical work described below. Location(Street&Number) .66$ ' V' Owner or Tenant k$ Telephone No.u .r 7G• tiN Owner's Address (Inv. QS J ve Is this permit in conjunction with a building permit? Yes No III (Check Appropriate Box) Purpose of Building n[,�etkiUtility Authorization No. Existing Service /() Amps /AO Volts Overhead 1E ❑ Undgrd No.of Meters I 1; New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Locationand Nature of Proposed Electrical Work: Ins-61 041 m (4 roof r ~lJ '�1 1nkpn� `p C`VoLl-n c. FLnr S t }ems . 093 iletfriS 7. / Kl Completion of the following_table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KVV 'Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Valu 'cal Work: 1% „CO (When required by municipal policy.) Work to Start: pt801 x Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such cove a is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE BOND ❑ OTHER ❑ (Specify:) I certify, under t •p 'ns and pen 1 ties of perjury,that the information on this application is true and complet . FIRM NAME: k Ili 1 I LIC.NO.: 1 Licensee: , Q $ j n,►_ A— Signature / / LIC. _ NO..: (If applicable enter 'e empt"i ,t�e license nuber le,1- Bus.Tel.No.: - 5A Address: C95.nits S1sn Rita /0U/1100 t .Mg . O 720 Alt.Tel.No.: *Per M.G.L.c. 147, 57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE* DESCRIPTION •SYSTEM SIZE:7100W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), FAR -SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(20)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE +r - LTD:LR4-60HPB-355M INSTRUCTIONS. L r `_s.__- -0 - -q PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. PV-3.0 LAYOUT SE6000H-USSN 0MAIN PANEL •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. y __ PV-4.0 ELECTRICAL TRACK ON COMP,SEE DETAIL SNR-DC-00436 SNR MOUNT PV-5.0 SIGNAGE •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. WITH NEW 100 AMP MAIN PANEL WITH 125 AMP BUSBAR WITH 100 AMP MAIN BREAKER. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER M CHIMNEY •SERVICE ENTRANCE CONDUCTORS TO BE REPLACED. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 0ATTIC VENT SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. a PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT ' CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). [ACI AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. OC •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. 0 DC DISCONNECT(S) FIRE SETBACKS •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. O CB ' IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY AREINTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION SHOWN AS DASHED L J SCALE NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER VICINITY MAP CC COMP COMPOSITION #180120 DC DIRECT CURRENT (E) EXISTING 695 Nees STAND.BLVD,TAUNTON,MA,02790-7331 ESS ENERGY STORAGE SYSTEM 'A o° EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC DAVID MACARY II MSP MAIN SERVICE PANEL 5 WEDGEMERE RD,YARMOUTH, CUcwr adN (N) NEW MA,02673 NTS NOT TO SCALE c11OOTv RdN OC ON CENTER TEL.(973)670-2458 PRE-FAB PRE-FABRICATED APN:YARM-000048-000039-010000 PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: N 223R-005MACA a° RSD RAPID SHUTDOWN DEVICE „r '•j• 7,-":;, TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL 'y V VOLTS ERWIN BARTOLOME �9P%Pq SHEET REV NAME WATTSW DATE COMMENTS COVER SHEET a REV:A2 4/13/2022 PAGE PV-1.0 SITE PLAN-SCALE=V16"=1'-0" ARRAY TRUE MAG PV AREA (E)DRIVEWAY • I I PITCH AZIM AZIM (SOFT) \iT„I AR-01 16° 226° 240° 392.2 F (E)FENCE g Q. F (E)RESIDENCE 4 ° o �F 'Po ° ° (N)ARRAY AR-01 \' (E)DECK-- —(E)SKYLIGHT (E)DETACHED- STRUCTURE ,' V � ° '`i (E)FENCE '4 / <, *6 ., l• I 11;1 *111:110' 0 i . .. N>/ i• 4: C EMP Id 0 PM sunrun .2... 0 #180120 NS MYLES STANDISH BLVD,TAUNTON,MA.02780-7331 (E)GATE PXONE 0 0 \ ,t.' CUSTOMER RESIDENCE: (E)SKYLIGHT DAVID MACARY / 5 WEDGEMERE RD,YARMOUTH, 't MA,02673 \ v YAR TEL.( 670-2458 APN:YARM-000048-000039-010000 / PROJECT NUMBER: 223R-005MACA \ DESIGNER: (415)560E920 ex3 ERWIN BARTOLOME SHEET \\\/ SITE PLAN \v/ REV:A2 4/13/2022 PAGE PV-2.O • ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF AR-01 COMP SHINGLE-RLU 1-Story 2XRL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:8 RAFTERS 13'-0" 16" COMP,SEE DETAIL SNR-DC-00436 - 1'-7" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: D1-AR-01-SCALE:3/16"=1'-0" 5/16"x 4.5":2.5"MIN EMBEDMENT AZIM:226° STRUCTURAL NOTES: PITCH:16° • INSTALLERS SHALL NOTIFY —(E)SKYLIGHT ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. - 2'-10"• -- 23'-3" — - —6'-8" { -17'-5" '-2'-7"-' • IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" BOUNDARY REGION OF ANY 1' " ROOF PLANE EDGES -•• • = mijoi (EXCEPT VALLEYS),THEN - ° - - = = ATTACHMENTS NEED TO BE ADDED AND OVERHANG NM REDUCED WITHIN THE 12" BOUNDARI - - FOLLOWS: REGION ONLY AS 10'-4" •• O WABLE NT • AT INDICATED ON .. ' PLANS TO BE REDUCED BY _ _ ALL WABLE OVERHANG N PLANS TO • • El • • I OEM ••BE 1/5TH OP ALLOWAB E ATTACHMENT SPACING 2,-6" INDICATED ON PLANS I 29,-1",-- -- -6,-8,. ,_ 11'-7" '-2'-7"_' sunrun --(E)SKYLIGHT #180120 BS MYLES STANDMiH BLVD,TAUNTON,MA,02790,331 STRUCT,. F....0 BB ONL (HOFAy� y1FN Sk CUSTOMER RESIDENCE: it' VINCENT N,°yG DAVID MACARY g MWUMVANEZA N 5 WEDGEMERE RD,YARMOUTH, CIVIL MA,02673 ..��`" TEL(973)670-2458 �` ONAI��' APN:YARM-000048-000039-010000 PROJECT NUMBER: 223R-005MACA DESIGNER: (415)580-6920 ex3 ERWIN BARTOLOME SHEET LAYOUT REV:A2 4/13/2022 PAGE PV-3.0 ( 120/240 VAC SINGLE PHASE SERVICE METER#: < O EVERSOURCE 2291109 UTILITY GRID NEW 100A MAIN (1 PANEL NEW 100A BREAKER I j, .__LOADSIDETAP r I NEW 100A MAIN (N)LOCKABLE BLADE TYPE (N)MA SMART SOLAREDGE TECHNOLOGIES: BREAKER FUSED AC UTILITY SE6000H-USSN WTH 1 DISCONNECT REVENUE REVENUE GRADE METERING METER � 6000 WATT INVERTER JUNCTION BOX � PV MODULES NEW 100A MAIN A Z (2) OR EQUIVALENT l' LONGI GREEN ENERGY TECHNOLOGY < ^ PANEL WITH AAA l� / CO LTD:LR4 60HPB 355M 125A BUSBAR \� O — •— I �— I '(1)// (20)MODULES FACILITY 35A FUSES --- u ��Ir' OPTIMIZERS WIRED IN: LOADS �Gp o SQUARED I I (1)SERIES OF(10)OPTIMIZERS 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(10)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND sun r u n 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THW HN/THN-2 #180120 665 MYLES STAMM...,,TAUNTON,MA,12790.7111 ONES FAX 0 CUSTOMER RESIDENCE: DAVID MACARY 5 WEDGEMERE RD,YARMOUTH, MA,02673 MODULE CHARACTERISTICS TEL.(973)670-2458 LONGI GREEN ENERGY P401 OPTIMIZER CHARACTERISTICS: APN:YARM-000048-000039-010000 TECHNOLOGY CO LTD: MIN INPUT VOLTAGE: 8 VDC LR4fi0HPB-355M: 355 W MAX INPUT VOLTAGE 60 VDC PROJECT NUMBER: OPEN CIRCUIT VOLTAGE: 40.6 V MAX INPUT ISC: 11.75 ADC MAX POWER VOLTAGE: 34.6 V MAX OUTPUT CURRENT: 15 ADC 223R-005MACA SHORT CIRCUIT CURRENT: 11.25 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 ERWIN BARTOLOME SYSTEM SIZE: 7100 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 10 V SYSTEM OPERATING VOLTAGE: 380 V ELECTRICAL MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 18.68 A REV:A2 4/13/2022 SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.o INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING W THE OPEN POSRION LABEL LOCATION: METHOD AND SHALL NOT BE HAND RITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(8) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D((2(,IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) ,f 72 ' SL:',.: MULTIPLE SOURCES OF POWER A ••:�02'• 1'.n+:�.I lei•••,"•f,••� t. 31.1;'::::: t-S / �"U SAO DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: pI INSTALLED R NECF 20 :690.DOWN sunrun LABEL LOCATION: SWITCH PER IFCCODE(S):201NC 2020:690.56(C)(2),IFC SOLAR PANELS ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). I ON ROOF PER CODE(S):NEC 2020: L 705.12(B)(3)(2) ' ' MAIN PANEL(INT) Ak SOLAR PbV�SYSTEM � EQUIPPED #16D,2D PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN D© N 4 ' 6. E`ESST SVD TAUNTON M•o'�'�' COMBINER PANEL1 PHONE. ao DO NOT ADD LOADS CUSTOMER RESIDENCE: LABEL LOCATION: SERVICE ENTRANCE DAVID MACARY PHOTOVOLTAIC AC COMBINER(IF AC DISCONNECT 5 WEDGEMERE RD,YARMOUTH, APPLICABLE). 3„ PV PRODUCTION METER MA,02673 PER CODE(S):NEC 2020:705.12(0)(2)(3)(c) TURN RAPID SHUTDOWN SWITCHTOTHE"OFF' 1106A1111.11110 INVERTER (EXT) TEL.(973)670-2458 POSITION TO SHUT DOWN APN:YARM-000048-000039-010000 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:25.00 AMPS SHOCK HAZARD IN THE MI 223R-005MACA NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. DESIGNER: (415)580-0920 ez3 LABEL LOCATION: 5 WEDGEMERE RD YARMOUTH, MA 02673 ERWIN BARTOLOME A AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF , , INTERCONNECTION. . SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A2 4/13/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0