Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-22-006269
,r; V1/ Commonwealth of Official Use Only E. ; Massachusetts Permit No. BLDE-22-006269 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked Rey.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:5/2/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 10 WOODBINE AVE Owner or Tenant Jorge Fuzer Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(22 Panels 7.48 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- 1:1No.of Emergency Lighting grad grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 bki`A &fZL f4,41&, Commonwealth �/1// // Official Use Only Commonwealth o//Yladdachudelld R E C lsp �' ® Permit No. C�Z —6, -1 i _ 2eparlmenl o�.}ire Serviced ',c 1,!!' Be ARD OF FIRE PREVENTION REGULATIONS Occupancy. 1/07] and Fee Checked) APR �.J„-tom [Rev. 1/07] (leave blank) SUILDING DAPP de ' TION FOR PERMIT TO PERFORM ELECTRICAL WORK By ------ - work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 4-a(.'-act �/ City or Town of: l rrrrn h To the Inspector of Wires: By this application the e of his or her intention to perform the electrical work described below. undersigned-gives noti Location(Street&Number) 16 LA I re.. 1:14"J Owner or Tenant O��, rufr n Ov Telephone No. -A ” 83 Owner's Address r�IIA. Q' ej Is this permit in conjunction with a building permit? Yes No El (Check Appropriate Box) Purpose of Building n(�ei'( Utili Authorization No. Existing Service /O Amps / Volts Overhead Undgrd❑ No.of Meters I New Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: ins-of 0--inn nt r 1YY" r, phernVotinte. Tior si terms . as pa r 7,y KL3V , Completion of the.followinntable may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No. T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local E] Li 1-1 Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Valu of ical Work: I� IC14 tet (When required by municipal policy.) Work to Start: ' ', Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such covea is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE [ BOND ❑ OTHER ❑ (Specify:) I certify,under t •p, ns and pen,lties of perjury,that the information on this application is true and complet . FIRM NAME: l I. 1 . LIC.NO.:_ _Q_ Licensee: k S • j I_ .A' Signature / _ 1 LIC.NO.: (If applicable enter a empt' i t e license nuber lyze„1.. 1 �y��7 q Bus.Tel.No.•M /2:5 : __ Address: 0,5. , ies Gf1GlSti G ka, l ounkv t Mil , �O+ /O o Alt.Tel.No.: *Per M.G.L.c. 147,s?57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/AgentPERMIT FEE: $ SignatureturaTelephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS •SYSTEM SIZE:7480W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), elS —SOLAR MODULES PAGE# DESCRIPTION •MODULES:(22)JA SOLAR:JAM60S10-340/MR MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE 4 —RAIL PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. WI P o 0 SE6000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. ° A- e PV-2.0 SITE PLAN •RACKING:SNAPNRACK RLU:RL UNIVERSAL,SPEEDSEAL MP P MAIN PANEL o D PV-3.0 LAYOUT TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. b n I- p PV-4.0 ELECTRICAL SNR MOUNT / STANDOFFS-- •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT& -- &FOOTINGS PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SKIRT •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) r"--, SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. DC DISCONNECT(S) FIRE SETBACKS •16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX • HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(8)(2). '--- CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L-I SHOWN AS DASHED SCALE NTS AC ALTERNATING CURRENT s u n ru n AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION Hr DC DIRECT CURRENT #180120 (E) EXISTINGSOS MYLESSTANDISHBLVD.TAUNTON.MA,oneo.T33I ESS ENERGY STORAGE SYSTEM PHONE D FAY U — IV .B.yber ti HIIIS EXT EXTERIOR -�`— Goll Cour ae INT INTERIOR CUSTOMER RESIDENCE: x v MAG MAGNETIC JORGE FUZER ' MSP MAIN SERVICE PANEL 10 WOODBINE AVE,YARMOUTH, _ (N) NEW MA,02673 NTS NOT TO SCALE _kp ;, OC ON CENTER TEL.(508)280-8983 PRE-FAB PRE-FABRICATED APN:YARM-000037-000109 .4 PSF POUNDS PER SQUARE FOOT '4. PV PHOTOVOLTAIC PROJECT 223R-0ONUM ER: ' RSD RAPID SHUTDOWN DEVICE .� J Woodbine A e::st TL TRANSFORMERLESS DESIGNER: ( ) rnoaln,M U�b?3 TYP TYPICAL 415 580-69208x3 0 BRAD SOBER © Air t+c. VII MI r ,kv�te V VOLTS HYANNI, vrtsr REV NAME WATTS DATE COMMENTS SHEET `' ,AR6100THCOVER SHEET drs Park 8,0, $4 1 • — REV:A 4/22/2022 0M ,rai , r°r - t4 PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1/16"=1' PITCH AZIM AZIM (SOFT) AR-01 20° 137° 151° 307.8 AR-02 20° 317° 331° 90.5 0� e (N)ARRAY AR-02 -(N)ARRAY AR-01 40 (E)RESIDENCE INV PMO101 '��►• sunrun • �'. #180120 EMS PHONE s ST00011 E1,0 TAUNTON.MA.02780-7.331 (E)FENCE FAX CUSTOMER RESIDENCE JORGE FUZER 10 WOODBINE AVE,YARMOUTH, MA,02673 d' TEL.(508)280-8983 APN:VARM-000037-000109 PROJECT NUMBER: 223R-010FUZE DESIGNER: (415)580-6920 ex3 BRAD SOBER SHEET SITE PLAN REV:A 4/22/2022 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF 12'- RL UNIVERSAL,SPEEDSEAL TRACK ON - WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 1'-11" STAGGERED 140 MPH 3-SEC GUST. - S.S.LAG SCREWS: 12'- RL UNIVERSAL,SPEEDSEAL TRACK ON AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 5/16":2.5"MIN EMBEDMENT S.S. 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 1'-11" STAGGERED LAG SCREWS: 5/16":2.5"MIN EMBEDMENT D1-AR-01-SCALE:3/16"=1'-0" STRUCTURAL NOTES: AZIM:137° 1'-5" • INSTALLERS SHALL NOTIFY PITCH:20° _1-1' ...._. _.._ _.... ____ 33.7" .l} ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES 1Iu I OBSERVED 0 0 0 0 0 0 0 PROCEEDING W/RTO INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY 0 0 0 0 0 0 REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), 9'-11° STRUCT THEN ATTACHMENTS NEED Q 5'-4"TYP- nn dNE IS OF/4444 TO BE ADDED AND OVERHAN( o� �+60, REDUCED WITHIN THE 12" a� VINCENT G, BOUNDARY REGION ONLY AS fi MWUMVANEZA H FOLLOWS: CIVIL ••ALLOWABLE ATTACHMENT -'d.�p 4y. SPACING INDICATED ON 2'-10" ,y •�f' EN���`4 PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG 4 16'-9" INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/4"=V-0" AZIM:317° s u n r u n PITCH:20° 6'-0° r 27-11" ;1,-0„` l ❑ ❑- __---_ _-E}._._------ — - ❑._.._. -.------❑-..--- --._..,$-----_._---❑ -_..__ _....... #180120 605 NVLES STANDISN BLVD,TAUNTON MA,0000-7. PHONE FAX 0 (' C') 5 4 TYP-----(} CUSTOMER RESIDENCE: ,) ') -----_----` JORGE FUZER 10 WOODBINE AVE,YARMOUTH, MA,02673 TEL.(508)280-8983 APN:VARM-000037-000109 y. PROJECT NUMBER: 223R-01OFUZE DESIGNER: (415)580-6920 ex3 BRAD SOBER SHEET LAYOUT REV:A 4/22/2022 PAGE PV-3.0 • • 120/240 VAC SINGLE PHASE NOTE:TOTAL PV BACKFEED=31A SERVICE USED FOR INTERCONNECTION CALCULATIONS METER#: < O EVERSOURCE 2289393 UTILITY GRID I EXISTING / 100A MAIN l BREAKER I — 125EXIA (N) (N)MA SMART SOLAREDGE TECHNOLOGIES: < �� MAIN N (N)LOCKABLE UTILITY SE6000H-USSN WITH FACILITY PANEL BLADE TYPE REVENUE REVENUE GRADE METERING AC DISCONNECT METER 6000 WATT INVERTER JUNCTION BOX PV MODULES LOADS C - C� (i) OR EQUIVALENT D JA SOLAR:JAM60S10-340/MR c�--o f .�� J 't// (2P)MODULES OPTIMIZERS WIRED IN: (1)SERIES OF(11)OPTIMIZERS ' I I (1)SERIES OF(11)OPTIMIZERS (N)35A -I--= SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT PV BREAKER AT DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P370 OF BUSBAR 120/24OVAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 6.B5 MYLES STAND.BLVD.TAUMON.MA.02790-731+ PHONE FA%0 CUSTOMER RESIDENCE: JORGE FUZER 10 WOODBINE AVE,YARMOUTH, MA,02673 MODULE CHARACTERISTICS TEL.(508)280-8983 JA SOLAR:JAM60S10-340/MR: 340 W P370 OPTIMIZER CHARACTERISTICS: APN:YARM-000037-000109 OPEN CIRCUIT VOLTAGE: 41.55 V MIN INPUT VOLTAGE: 8 VDC MAX POWER VOLTAGE: 34.73 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: SHORT CIRCUIT CURRENT: 10.46 A MAX INPUT ISC: 11 ADC 223R-010FUZE MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 BRAD SOBER SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 7480 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 19.68 A REV:A 4/22/2022 SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 ,t INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(6) A DUAL POWER SUPPLY SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: CAUTION • UTILITY SERVICE METER AND MAIN SERVICE PANEL. ■ PER CODE(S):NEC 2020 705.12(C) RAPID SHUTDOWN SWITCH _ MULTIPLE SOURCES OF POWER FOR SUGAR PV SYS EM 1p DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN ADJACENT LOCATION: SWITCH012: PER CODE(S):201:NEC 2020:690.56(C)(2)IFC s u n r u n OCPD(INATOIC BREAKER AND ESS 2012 605.11.1 IFC 2018:1204.5.3 SOLAR PANELS ON RO PERC(IFE(S):NEC02 I PERCODE(S):NC2020:705.12(8)(3)(2)A SOLAR PV SYSTEM EQUIPPED SERVICE ENTRANCE AND PVpwPHOTOVOLTAIC BREAKER DISCONNECTCOMBINER PANEL EM WITH RAPID SHUTDOWN DO NOTADD LOADSCUSTOMER RESIDENCE: LABELLOCATION. AC DISCONNECT JORGEFUZER PHOTOVOLTAIC AC COMBINER(IF10 WOODBINE AVE,YARMOUTH, IMA,02673 APPLICABLE). PER CODE(S):NEC 2020:705.12(0)(2)(3)(°) 3 TURN RAPID SHUTDOWN SWITCH TO THE"OFF' IVIVAILS TEL.(508)280-8983 POSITION TO SHUT DOWN APN:YARM-000037-000109 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT-25.00 AMPS SHOCK HAZARD IN THE 223R-010FUZE NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. IIII INVERTER (EXT) A _ DESIGNER: (415)580-6920 ex3 CDISCONNEIOCT(S),PHOTOVOLTAIC SYSTEM POINT OF 10 WOODBINE AVE, YARMOUTH, MA, 02673 BRAD SOBER INTERCONNECTION. SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE ON DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 4/22/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0