Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-22-000340
. Yh . DIRECTORY NEW PV SYSTEM: LILLIAN SPAIN PV3 PRO S EPCT LAN SUMMARY PV2 NOTE39 SWIFTBROOK RD, S YARMOUTH, MA 02664, USA PV4 SITE PLAN 41°669941, -70°210762 PV5 ATTACHMENT DIAGRAM MI6 ATTACHMENT AILSAELEVATON PV7 THREEUNE DIAGRAM PV SYSTEM RATING (DC): 8.25 KW BILL OF MATERULLS SUMMIT PV9 WARNING LABELS PV10-PV13 DATA SHEETS ENERGY SYSTEM INFORMATION It` . - ' !,A‘r-4,7*-"�V. *...- DC SYSTEM SIZE 8.25 KW .pis M 111 EPC COMPANY: AC SYSTEM SIZE 7.8 KW : , ^ I , SUMMIT ENERGY GROUP • DC/AC RATIO 1.09 REC THAN PEAK SERIES BLACK \ - ' 293 UBBEY INDUSTRIAL PKWY, a" MODULE 330W I �4aMA• • UNIT 250.WEYMOUTH, MLPE/INVERTER SOLAREDGE TECHNOLOGIES, 0 a " 88857898848 P340,SE7600H-US / t • Wwwsummitsolarenergy.eom • RACKING SNAPNRACK - �1, _j ! Nt. s Q a A. - CUSTOMER DETAILS ATTACHMENTS ULTRA RAIL COMP KIT ..y- .'. ,. ' gip: I- TOTAL ARRAY AREA 450 SOFT. 7 cr O NO.OF MODULES 250 10 �- ,ti - M, ARRAY 1 AZIMUTH 158° Z g ARRAY 1 PITCH 22° +",,,g,",p�� ,;-' 400. , tr1''„". 4 + d Z CO j c•1 Z ARRAY 2 AZIMUTH •-• t. s , oT r f �. N - 1:: ARRAY 2 PITCH t. " — ARRAY 3 AZIMUTH - '� i ~'I - O o CI n H ARRAY3PITCH - ' • `•. cc Z d ARRAY 4 AZIMUTH - t , i w,ft_ - � m O Wg ARRAY4PITCH - >� ..tea , / . .�^. .. ~ Q .t' LL a ARRAY 5 AZIMUTH - - - :�`".:`s § Z ARRAY 5 PITCH - U rn 0 AVERAGE TSRF - UTILITY NAME EVERSOURCE O AERIAL VIEW © STREET VIEW PROJECT ID:MAEVE8.25-805 REMOTE YES NOT TO SCALE NOT TO SCALE PREPARED ON:07/15/2021 MONITORING DRAWN BY: V.N. SITE DETAILS INTERCONNECTION DETAILS CHECKED BY: S.T. ASHRAE EXTREME LOW 3.2°F(-16°C) /\ NEW SUPPLY SIDE AC STAMPED BY: S.W. ASHRAE 2%HIGH 82.4°F(28°C) /, T DESIGN ENGINEER POINT OF CONNECTION CONNECTION PER NEC UTILITY:EVERSOURCE CLIMATE DATA BARNSTABLE MUNI BOA, /'/' \ SIDDHARTH TEMBURNI ARTICLE 705.12(A) PE STAMP WITH SIGMA - SOURCE MA,USA(WMO:725067) \ N NABCEP PVIP CERTIFIED UTIUIY SERVICE 120/240V 1$ `/ SID@SUMMIT.SOLAR 100A MAIN BREAKER,100A NAND SPEED 130 MPH(ASCE 7-10) ; ELECTRICAL PANEL PANEUBUSS RISK CATEGORY II \ , �' PROFESSIONAL ENGINEER TH OF NAND EXPOSURE �� 1 SCOTT WYSSUNG MODE OF INTERCONNECTION BTM,LINE SIDE TAP „...-4',.:34.-1H . CATEGORY B /�/' W CONSULTING SERVICE ENTRANCE OVERHEAD ry/ �, �, ' P.E.STRUCTURAL,PP,CAS I: ,w y. i`I °., GROUND SNOW LOAD 30 PSF \ /� (0):R01)8743483 I �� DOCUMENT DESCRIPTION ' APPLICABLE CODES&STANDARD M m " THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF '�O�'A Q . DESCRIBING THE DESIGN OFA PROPOSED PHOTOVOLTAIC POWER F QST FF. MASSACHUSETTS BUILDING SYSTEM WATH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE HATH S ZONAL EHG�a BUILDING CODE,9TH EDITION,AS AMENDED SCOPE OF WORK APPUCABLE CODES AND REGULATIONS.THE DOCUMENT SHALL NOT (/80 CMR) THIS PROJECT'WOLVES THE INSTALLATION OF SOLAR PANELS.THE BE R INSTALLATUED ION INSTRAS A UCTIONS CONTRACTTITUTE FOR OR SHALL INSTALLRER - MASSACF1USE FISELEC I FOCAL SOLAR PANELS WALL BE RACKED USING A PRE-ENGINEERED RACKING EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC AND NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY PAGE DESCRIPTION ELECTRICAL CODE(527 CMR 12.00)NFPA 70E PLOT MAP (2017NEC) 1E11 TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL THAT OVERRIDES THEM.CONTRACTOR IS RESPONSIBLE FOR PV 1 MASSACHUSETTS COMPREHENSIVE NOT TO SCALE UTIUTY USING MEANS AND METHODS CONSISTENT WITH THE RULES VERIFICATION OF ALL CONDITIONS,DIMENSIONS,AND DETAILS IN THIS FIRE FIRE SAFETY CODE(527 CMR 1 00) ENFORCED BY THE LOCAL UTIUTY AND PERMITTING JURISDICTION. DOCUMENT. PROJECT SUMMARY ,..----q- L......‘).. 2_2 _, o cc 2.1.1 SITE NOTES: LEG E N D S //�`///��\\ 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 L� REGULATIONS. THROUGH 250.106.IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE.A 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM ISA GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. AND AHJ. �.— 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL.OR 2.4.10 ACCORDING TO NEC 690.47(C)(3),UNGROUNDED SYSTEMS INVERTER MAY SIZE DC A_ JUNCTION BOX BUILDING ROOF VENTS. GEC ACCORDING TO EGC REQUIREMENTS OF NEC 250.122.HOWEVER.DC GEC TO BE 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED UNSPLICED OR IRREVERSIBLY SPLICED. CI ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 2.4.11 IN UNGROUNDED INVERTERS,GROUND FAULT PROTECTION IS PROVIDED 2.1.6 ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN BY"ISOLATION MONITOR INTERRUPTOR.'AND GROUND FAULT DETECTION [ SUMMIT ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURERS PERFORMED BY'RESIDUAL-CURRENT DETECTOR.' INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE 2.5.1 INTERCONNECTION NOTES: 5.2 LOAD-SIDECNWITH INTERCONNECTION ECTION SHALL BE IN ACCORDANCE TH[NEC 690.64 ENERGY BUILDINGPM EQUIPMENT LOCATIONS (B)] 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.5.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT 2.2.3 WRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED EXCEED 120%OF BUSBAR RATING[NEC 705.12(D52X3)]. PV INVERTER EPC COMPANY: OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C)AND NEC TABLES 2.5.4 WHEN SUM OF THE PV SOURCES EQUALS>100%OF BUSBAR RATING,PV + 1 310.15(8525A(AND 310.15(8)(3)(C). DEDICATED BACKFFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE 7 [�� SUMMIT ENERGY GROUP 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(D)(2)(3)]. ARa/ ACCORDING TO NEC 690.34. 2.5.5 AT MULTIPLE INVERTERS OUTPUT COMBINER PANEL.TOTAL RATING OF ALL B 2.2.4 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. 293 UBBEY INDUSTRIAL PKWY, WITHIN SIGHT OF THE AC SERVICING DISCONNECT. HOWEVER,THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED UNIT 250,WEYMOUTH, 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC 705.12(D)(2X3XC). LINE MA 02189,USA ACCORDING TO NEC APPLICABLE CODES. 2.5.8 FEEDER TAP INTERCONECTION(LOAD SIDE)ACCORDING TO NEC 705.12 888-578-6648 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR (D)(2)(1) _p,p NON FUSIBLE USAGE WHEN APPROPRIATE. 2.5.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH \O\O AC DISCONNECT www.summitsolarefergy.Com 2.3.1 STRUCTURAL NOTES: SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.3.2 RACKING SYSTEM&PV ARRAY WILL BE INSTALLED ACCORDING TO 2.5.8 BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS LOAD CUSTOMER DETAILS CODE-COMPLIANT INSTALLATION MANUAL.TOP CLAMPS REQUIRE A EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12(DX5)[. DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH I- ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO61 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS. THE TERMINALS MARKED'LINE SIDE'(TYPICALLY THE UPPER TERMINALS). LINE p p 0 O4 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE FUSIBLE IFR QUIR ROOF-PENETRATING TYPE,IT SHALL BE FLASHED&SEALED PER LOCAL LOCKABLE,AND BEA VISIBLE-BREAK SWITCH. AC DISCONNECT U N 3 Z REQUIREMENTS. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND 2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED. SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED THEREFORE BOTH MUST OPEN WHERE A DISCONNECT IS REQUIRED, LOAD �.+ a-O CO Tn CNI CONTRACTOR. ACCORDING TO NEC 690.13. QQZ 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 2.6.5 DC DISCONNECT INTEGRATED INTO ROOFTOP DC COMBINER OR INSTALLED -6 W Y csi r SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. WITHIN 6 FT,ACCORDING TO NEC 690.15(C). [L-, 2.3.6 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE 2.6.6 RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY _.,-1 IX 0 0 Lu 3 STAGGERED AMONGST THE ROOF FRAMING MEMBERS. OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS.CONTROLLED 0 UTILITY/NET METER m 2 O W 2.4.1 GROUNDING NOTES: CONDUCTORS 530V AND 5240VA[NEC 690.12].LOCATION OF LABEL &DIRECTIONAL 03 I Q 2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND ACCORDING TO AHJ. LL d GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH 2.6.7 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9, z USE. AND 240. co U 2.4.3 AS IN CONVENTIONAL PV SYSTEMS,UNGROUNDED PV SYSTEMS REQUIRE AN 2.6.8 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED, / el0 EQUIPMENT GROUNDING CONDUCTOR.ALL METAL ELECTRICAL EQUIPMENT AND THEREFORE BOTH REQUIRE OVER-CURRENT PROTECTION,ACCORDING TO f •, STRUCTURAL COMPONENTS BONDED TO GROUND.IN ACCORDANCE WITH 250.134 OR NEC 240.21.(SEE EXCEPTION IN NEC 690.9) 1 250.136(A).ONLY THE DC CONDUCTORS ARE UNGROUNDED. 2.6.9 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION • UTILITY ELECTRIC GRID PROJECT ID:MAEVE8.25-805 2.4.4 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 890.43 AND MINIMUM ACCORDING TO NEC 690.11 AND UL16998. PREPARED ON:0(15/2021 NEC TABLE 250.122. 2.7.1 WIRING&CONDUIT NOTES: fr, 2.4.5 METAL PARTS OF MODULE FRAMES,MODULE RACKING.AND ENCLOSURE 2.7.2 ALL CONDUIT AND WIRE WILL BE USTED AND APPROVED FOR THEIR PURPOSE DRAWN BY: V.N. CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE CHECKED BY: S.T. 2.4.6 EACH MODULE WILL BE GROUNDED USING WEER GROUNDING CLIPS AS SHOWN IN REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. / \ STAMPED BY: S.W. MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ.IF WEEBS ARE 2.7.3 ALL CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. NOT USED.MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED 2.7.4 EXPOSED UNGROUNDED PV SOURCE AND OUTPUT CIRCUITS SHALL USE WIRE ` / UTILITY:EVERSOURCE GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION LISTED AND IDENTIFIED AS PHOTOVOLTAIC(PV)WIRE[690.35(0)].PV V UTILITY/NET METER PE STAMP WITH SIGNATUR- REQUIREMENTS. MODULES WIRE LEADS SHALL BE LISTED FOR USE WITH UNGROUNDED !!l�I��� BIDIRECTIONAL 2.4.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT SYSTEMS,ACCORDING TO NEC 690.35(DX3). ® WITH METER MAIN THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO 2.7.5 PV WIRE BLACK WIRE MAY BE FIELD-MARKED WHITE[NEC 200.8(AX61[. ANOTHER MODULE. 2.7.6 MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. 2.4.8 GROUNDING AND BONDING CONDUCTORS.IF INSULATED,SHALL BE COLORED 2.7.7 ACCORDING TO NEC 200.7.UNGROUNDED SYSTEMS DC CONDUCTORS v�y,1H OF as GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] A PI IL y- '' /� w�' COLORED OR MARKED AS FOLLOWS: III j FIRE SETBACK III • FLASHING DC/DC POWER I L 0 ATTACHMENT OPTIMIZERS s0 DC POSITIVE-RED,OR OTHER COLOR EXCLUDING WHITE,GREY AND / GREEN SOLAR MODULES EGC 8 GC 90es, 'O�S•� -EO�,�P DC NEGATIVE-BLACK,OR OTHER COLOR EXCLUDING WHITE,GREY _STRINGS S CONAL ENWa AND GREEN • ON THE _ BONDED AND 2.7.8 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: '1 ROOF/GROUND ___._. BLACK RAIL — GROUNDED PHASE A OR L1-BLACK R BACK FEED PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE ,- -;c - e BREAKER SMART/ TESLA5,C RESIDENTIAL PHASE C OR L3-BLUE,YELLOW,ORANGE.,OR OTHER CONVENTION y.` t I_I PRODUCTION L BATTERY OPTION PAGE DESCRIPTION NEUTRAL-WHITE OR GREY .. .. O ELECTRIC I I METER -4•IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE WIRE TAPS PV 2 TO BE MARKED ORANGE[NEC 110.15]. PROJECT NOTES r J NOTE:THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO ///�//�\\\ DOCUMENSHOULDTE COD NOT BE WITH ALL APABLE CODES ANDO REGULATIONS.THE Z .DOCUMENTMANUFACTURER INS NOT BE REUED UPON AS SUBSTITUTE FOR FL LAL EQ O INSTALLATION MANUALS.INSTALLER SHALL INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS.NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. °‘( cilL SUMMIT cc O ENERGY EPC COMPANY: SUMMIT ENERGY GROUP 293 UBBEYUNITINDUSTWEY IALOU PKWY, 0\. UNIT 250,WEYMOUTH, MA 02189,USA 888578-6648 vrww.s ummits ola renergy.eom O `O CUSTOMER DETAILS P , 25 S.? an atj sr 0 >_< '',1 CD 25s a-Z Inn F # ��22 0 ce o �\ - Y� W E�- �° coJ� CCI Z 0. G�QP��� O O 156 5- 0 Q OF'‘'‘5���\ N NN\ON O z U A 0 O !O CJr PROJECT ID:MAEVE8.25-805 �l P�TiC� ` !on"0 /I I OIlii, PREPARED ON:07/15/2021 �i � BY: V.N. \_J``.10k I j O CHECKED BY: S.T. A�l�_`_`SG) STAMPED BY: S.W. SO GAN`.��� UTILITY:EVERSOURCE PGOI N4°M� x '( J 0.* PE S■`•TAMP WITH SIGNATUURR III •\�\� ``Q \ / FIN OF 7 $110 s OwIsc , `\ 1 \ tin 50 H / r�rt±tsr .E ,CQ- "� /ANAL I ' a 0 PLOT PLAN PAGE DESCRIPTION SCALE:1'0"=1'0" PV 3 PLOT PLAN NOTE 1:EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM Z—\ WORKINC CLEARANCES HER NEC 110.26. NOTE 2:CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE.. NOTE 3:CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL RELATED EQUIPMENT,CABLES,ADDITIONAL CONDUITS,BOXES, RACEWAYS,AND OTHER ACCESSORIES NECESSARY FOR A S U M M I T COMPLETE AND OPERATIONAL PV SYSTEM. NOTE 4:THE SYSTEM SHALL COMPLY WITH NEC ARTICLE 690,ALL ENERGY MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. E -50.40'- NOTE 5:WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN EPC COMPANY: INSIDE THE BUILDING,THEY SHALL BE CONTAINED IN METAL MS I SUMMIT ENERGY GROUP RACEWAYS,TYPE MC METALCLAD CABLE,OR METAL ENCLOSURES FROM THE POINT OF PENETRATION INTO THE B BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING (p 293 LIBBEY INDUSTRIAL PKWY, MEANS,PER NEC 690.31(G) O UNIT 250,WEYMOUTH, NOTE 6:ABOVE DIMNSSIONS ARE FOR THE RESPECTIVE ROOF PLANESMA 02189,USA MEASURED BETWEEN THE ROOF RIDGE TO THE EVE AND RAKE TO RAKE n 0- 888-578-6648 www.summitsolarenergy.com LEGENDS: O — CUSTOMER DETAILS 0 UTILITY METER MAIN.100A MAIN 0 0 An.: ITIS MAIN SERVICE PANEL I O O O O ---ARRAY 1 z AI-1 AC DISCONNECT i #25, REC 330W as z D N Z BC BREAKER CAN wci4 r R. WITH 60A MAIN BREAKER 0 #25,SE P340 o i FIRE CLEARANCE v _ TILT 22° w 9 se o r LU QI INVERTER 1 0 anon J z a J® JUNCTION BOX I �— `� u m 0 w REC 33OW 156 Z _STRINGS,MINIMUM 8 MODULES In V AND MAX 6000W PER STRING t° 1"MODULE CLEARANCE PROJECT ID:MAEVE8.25-805 PREPARED ON:07/15/2021 SM MA SMART METER DRAVVBY: V.N. SYSTEM INFORMATION CHECKEDBY: S.T. 1 ........--3.27. STAMPED BY: S.W. 1DC SYSTEM SIZE 8.25 KW UTILITY:EVERSOURCE AC SYSTEM SIZE 7.6 KW PESTAMP WITH SIGNATU- 6MODULE REC TWIN PEAK ' SERIES BLACK 330W 11 1H Of r �, OPTIMIZER& SOLAREDGE sc I INVERTER TECHNOLOGIES,P340, wr i , REC T-PEAK BLACK SERIES, TOTAL ARRAY oz`s„Nn so�Q = REC330TP3M,330W A AREA 450 SQ.FT. / '"s.;'�sT - H,� NOTE:THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN �ONpt EpG TOTAL NO.OF 25 W OFA PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO _�_/ MODULES DEMONSTRATE COMPUANCE TH ALL APPLICABLE CODES AND REGULATIONS.THE SITE PLAN DOCUMENT SHOULD NOT BE REUED UPON AS A SUBSTITUTE FOR FOLLOWNG ARRAY 1 AZIMUTH 156° PAGE DESCRIPTION MANUFACTURER INSTALLATION MANUALS.INSTALLER SHALL INSTALL ALL EQUIPMENT IN ` ' " ' " ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS.NOTHING IN THIS / 0 O =1 O SCALE:1ARRAY 1 PITCH 22° PV 4 DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. t UTILITY NAME EVERSOURCE SITE PLAN • r Zns, SUMMIT ENERGY EPC COMPANY: SUMMIT ENERGY GROUP 293 LIBBEY INDUSTRIAL PKWY, — UNIT 250,WEYMOUTH, MA 02189,USA 888-578-6848 www.summitsolarenergy.com I 0 0 0 0 CUSTOMER DETAILS _— --ARRAY 1 #25, REC 330W 1- 0 'r> 4- 6 16 . 4 6 4 4 • 4 ® -' 4— #25, SE P340 $ m zW a . I ° s TILT 22° ao z < N z 0 ° a 0 $--4 6 $4 M - - 6 -I LIJ o cm r. I W LEGENDS T — 48"MAX MOUNT SPACING CC 2 L a 2 L2X4 TRUSSES @24"O.C. SNAPNRACK UL 80 BLACK cq U rn o co ir IL 0 SNAPNRACK ULTRA RAIL COMP KIT - PROJECT ID:MAEVE8.25-805 PREPARED ON:07/15/2021 DRAWN BY: V.N. DEAD LOAD CALCULATIONS CHECKED BY: S.T. STAMPED BY: S.W. LOAD QTY. LBS. TOTAL LBS MODULES 25 41 1025 UTILITY:EVERSOURCE OPTIMIZERS 25 1.70 43 PE STAMP KITH SIGNA - - LINEAR FEET OF RAIL(R.) 180 0.4 72 . ULTRA RAIL COMP KIT 60 0.09 5 ;�y1H 00F SIMPLE GRIP-SQ 0 0.09 0 r ll .c� • MID CLAMPS 44 0.09 4 y.`_' Nsy• ` ,,,1 END CLAMPS 20 0.09 2 .. • L GROUND WEEBS 10 0.09 1 Nn 50 " - MISC.HARDWARE 0 NOTE 1:DIMENSIONS IN RED INK MEASURES THE HORIZONTAL 4 ��\�, -E� Q' TOTAL ARRAY WEIGHT 1152 DISTANCE BETWEEN RIDGE AND THE SIDE WALL / �s40/vAL 0NG\a�� AREA NAME QTY. SQ.FT. TOTAL SQ.FT. NOTE 2:MOUNTS/ATTACHMENTS SHOULD BE INSTALLED AS PER \. MODULES TOTAL ROOF AREA 25 18 450.00 MANUFACTURERS NOTE 3:FLASHINGS ONCE ..,SHOULD BE SEALED TO TIONS ``/` ATTACHMENT PLAN %OF ROOF AREA COVERED BY SOLAR PV(-/-) - WATER TIGHT / 1 O SCALE:1'0"=1'0" PAGE DESCRIPTION POINT LOAD(TOTAL ARRAY WT./ATTACHMENTS),LbsISq.ft. 19 NOTE 4:IF THE ROOF IS DETERMINED TO BE WEEK AT THE PV 5 INSTALL,STOP THE WORK AND NOTIFY THE PROJECT ENGINEER DIST.LOAD(TOTAL ARRAY WT./TOTAL SOFT.),Lbs/Sq.ft. 2.56 ATTACHMENT DIAGRAM SNAPNRACK ULTRA RAIL 92° L FOOT SHOWN. COMPATIBLE WITH ULTRA RAIL ALL PURPOSE 90° L FOOT MODULE HEIGHT OFF ROOF, RANGE: L-FOOT TO BASE ATTACHMENT SUMMIT DOWNSLOPE FROM ENERGY UR-40:31 3 i" - 4 i" ROOF PENETRATION EPC COMPANY: UR 60:41 4$" - 5 8' SUMMIT ENERGY GROUP FLASHING SHIELDS ENTIRE ROOF PENTRATION 293 UNT 250,WEYMOUTINDUSTRIAL H, #\c-)...A MA 02189,USA 888578-6648 ��� 16" LAG SCREW S.S. www.s u mmits ola renergy.eom CUSTOMER DETAILS ULTRA RAIL1 1-%tA��. COMP SHINGLE ROOFING,TYP. Z n v ilri> Ili � • IAti IA ` ROOF DECKING TYP. cr� - Oa z gl . mA 0 w �II11 4 `��V4 WOOD RAFTER SHOWN, �� SIMILAR AT OTHER STRUCTURAL ` 8 ' L MEMBER TYPES PROJECT ID:MAEVE8.25-805 PREPARED ON:07/15/2021 DRAWN BY: V.N. CHECKED BY: S.T. 2 2' MIN. EMBEDMENT STAMPED BY: S.W. h- 1 z" INTO WOOD MEMBER UTILITY:EVERSOURCE 1 1 2i PE STAMP WITH SIGNATU H1H OF-1-- 7 1 f tilt Wr. 5" ""' 1 / oma, c 1-g / FS�ONAt ENG`a��. ATTACHMENT DETAILS UR-40 RAIL I UR-60 RAIL 0 PAGE DESCRIPTION FOR USE WITH SNAPNRACK ULTRA SERIES RAILS PV 6 ATTACHMENT DETAILS • ` M NOTE 1:ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 8 690 NOTE 8:INSTALLATION SHOULD BE NEC 2020 CODE COMPLIANT NOTE 2:PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED NOTE 9:EQUIPMENT SHOULD BE SERVICE RATED Z \\\GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION.ALL OTHER EXPOSED METAL PARTS SHALL BE NOTE 10:WIRE SIZING SHOULD BE AS PER 690.31(NEC 2020) , GROUNDED USING UL-LISTED LAY-IN LUGS. NOTE- 11:NEUTRAL AND GROUND SHOULD BE BONDED ONLY ONCE NOTE 3:GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE NOTE 12:A SEPARATE GROUND ROD MUST BE INSTALLED FOR SOLAR PV AS PER NOTE 4:AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC)SHALL BE A MINIMUM SIZE#8AWG WHEN 250.52 A(1)THROUGH A(8)TO MEET NEC 2020 REQUIREMENTS. THE ADDITIONAL INSULATED,#6AWG IF BARE WIRE. GROUND ROD IS NOT REQUIRED AS PER 250.53 A(2)EXCEPTION WHICH READS IF A NOTE 5:EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45,AND BE A SINGLE ROD,PIPE,OR PLATE GROUND ELECTRODE HAS A RESISTANCE TO EARTH MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE OF 25 OHMS OR LESS. SUMMIT NOTE 6:GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF#4AWG OR LARGER ENERGY NOTE 7:DISCONNECTING MEANS SHOULD BE ACESSIBLE WITHIN 10'OF THE SUPPLY SIDE CONNECTION,IT CAN BE A FUSED DISCONNECT OR A MANUALLY OPERATED CIRCUIT BREAKER WIRE SIZING SCHEDULE EPC COMPANY: SUMMIT ENERGY GROUP WIRE ID GUAGE DESCRIPTION A 8 AWG THWN-2 COPPER EGC WIRE FROM JUNCTION BOX-GEC.#6 BARE CU WIRE ON THE ROOF BETWEEN THE RAILS 293 UBBEY INDUSTRIAL PKWY, B 10 AWG PV WIRE COPPER MODULES AND DC OPTIMIZER WIRE TO JUNCTION BOX UNIT 250,WEYMOUTH, C 10 AWG THWN-2 COPPER JUNCTION BOX TO INVERTER MA 02189,USA D,E,F 8 AWG THWN-2 COPPER LINE AND NEUTRAL WIRES FROM INVERTER-SMART METER-AC DISCO.-BREAKER CAN 888-578-6648 G 6 AWG THWN-2 COPPER BREAKER CAN-LINE SIDE TAP-MAIN SERVICE PANEL-GRID www.summitsolarenergy.com SYSTEM SUMMARY COMMUNICATION DIAGRAM CUSTOMER DETAILS STRING 1 STRING 2 STRING 3 SINGLE INVERTER MULTIPLE INVERTERS OPTIMIZER MAXIMUM OUTPUT CURRENT 15A 15A - a o OPTIMIZERS IN SERIES 12 13 - Fil FilFig � u> � NOMINAL STRING VOLTAGE 480Vdc z 2d o, DC OPERATING CURRENT 20.44APli I t„ a 0 }N A z TOTAL ARRAY STC POWER 8,250 WdC sou�ocE � � � � � ��1 y Lu 7 r H TOTAL AC SYSTEM SIZE 7600 Wac � !, Po�a` DAISY DAISY a Ez rx v COMMUNICATION SE 5 YR-GSM CELL KIT Gia7In _ -J wX 0 w INVERTER MAX INPUT DC/MAX OUTPUT AC 20Adc/32Aac �_� I 0 0 ui g INVERTER MAX INPUT DC POWER 11780Wdc z0 Lu ALLOWABLE MIN/MAX STRING POWER MIN B MODULES IN SERIES/MAX 6000W IN A STRING I— Ug m a z N 0 60A,240V AC NON FUSIBLE M 0 DISCONNECT IIDIRECTIONAL © LOCABLE,NEMA 3R, PROJECT ID:MAEVE8.25-805 MA SMART UL USTED METER SOCKET. GANG OPERATED, TILITY METER GRID PREPARED ON:07/15/2021 FORM 2S,200A SUPPLY SIDE25240V OPEN BLADE INTERCONNECTIONETER#236 83 10DRAWN BY: V.N. SOLAREDGE TECHNOLOGIES 120240V READILY ACCESSIBLESE7600H-US,NEMA 3R,UL LISTED. NEMA 3R 3'WITHIN UTILITY METER AS PER 705.12(A) CHECKED BY: ST. INTEGRATED GFDI AND DC DISCONNECT. 1_ STAMPED BY: S.W. EQUIPPED WITH RAPID SHUT DOWN G '' UTILITY:EVERSOURCE X c EN PE STAMP WITH SIGNATURE SOLAR EDGE LINE P340 OPTIMIZER , ;`�• 25-REC 330W 1 OPTIMIZER PER MODULE 4 // :4 O �cb ft wn ,,,A -.__—MAIN BONDING JUMBER 4 o)A LOAD- JUNCTION BOX G - 100A MAIN SERVICE PANEL. - 1 2 3 . 11 12 600V,UL LISTED A 100A MAIN BREAKER E _1 SQUAac RE E D SQUARD COMPANY •. ct Q N^ j V B C D E F nr 60A,240V BEAKER CAN Hi 3 12 13 40A MANUAL BREAKER. PAGE DESCRIPTION yy�- yy..A... �yp UL LISTED �_— WITHIN 10'FROM TAP PV 7 ELECTRIC DIAGRAM BILL OF MATERIALS /^\ WI CATEGORY MAKE&MODEL QTY DESCRIPTION /' \ MODULE REC TN PEAK SERIES BLACK 330W 25 REC 330W,MONO-CRYSTALLINE BOB L/__\ INVERTER SOLAREDGE TECHNOLOGIES SE7600H-US 1 HD WAVE SETAPP INVERTER SE7600H-US W/RGM&CONSUMPTIUON METER POWER OPTIMIZERS SOLAR EDGE P340 25 SOLAR EDGE 340W DC OPTIMIZERS(ONLY WITH SE INVERTERS) COMMUNICATION CELL KIT SOLAREDGE CELL-B-R05-US-S-S2 CELL 1 MODEM WITH 5 YRS FOR RESIDENTIAL SETAPP INVERTERS ENERGY IT CT CLAMPS SOLAR EDGE SEACT0750-200NA-20 200 CT - SOLAR EDGE CTs ONLY FOR SUNNOVA PROJECTS AC COMBINER PANEL 100A COMBINER EATON OR EQUI. - 60A,240V 3W 1PH AC COMBINER PANEL,NEMA 3R AC FUSIBLE DISCONNECT SQUARE D DU222NRB OR EQUIV. - 60A,OVER CURRENT PROTECTION DEVICE AS LISTED IN NEC 2020 EPC COMPANY: AC NON FUSIBLE DISCONNECT SQUARE D DU222RB OR EQUIV. 1 60A,OVER CURRENT PROTECTION DEVICE AS LISTED IN NEC 2020 SUMMIT ENERGY GROUP JUNCTION BOX EQUIVALENT JUNCTION BOX 1 DC COMBINER ENCLOSURE,600VDC,120A,UL1741,NEMA 3R,CSA C22.2 FUSES BUSS FUSETRON OR EQUI. - 40A,240VAC FUSES 293 LIBBEY INDUSTRIAL PKWY, BACK FEED BREAKER/BREAKER CAN MAIN EATON OR EQUI. 1 40A,2P MODE OF INTERCONNECTION,MAX RATED VOLTAGE:240VAC UNIT 250,WEYMOUTH, MA 02189,USA MA SMART METER/GENERATION METER SQUARE D OVERHEAD OR UNDERGROUND METER SOCKET 1 200A,120/240V,NEMA 3R SMART METER SOCKET 888-578-6648 CONDUIT RUN EMT TBD ONSITE i'OR 1"EMT CONDUIT RUN SHOULD BE INSTALLED AS PER THE CODE www.summitsolarenergy.com TRENCH RUN RIGID PVC SCHEDULE 80 TBD ONSITE TRENCH SHOULD BE AT LEAST 18"DEEP.USE WARNING TAPE DURING BACKFILL CUSTOMER DETAILS F- 0 0 2 N COMPONENT SPECIFICATIONS W > " z aV >y cs, Z NW N] r I- L9) CIg r 1 MODULES 7.W $o N. Ui /— TEMP. TEMP.COEFF. FUSE , Z a MAKE&MODEL QTY. PMAX PTC ISC VOC VMP m 0 la OF VOC RATING L xa REC 330TP 25 330W 246W 10.39A 39.9V 34.3V -0.28%/°C 20A Z BLACK rn 0 co POWER OPTIMIZERS PROJECT ID:MAEVE8.25-805 PREPARED ON:07/15/2021 MAXIMUM MAXIMUM DC RATED INPUT MAXIMUM DC WEIGHTED DRAWN BY: V.N. MAKE&MODEL POWER QTY. OUTPUT INPUT VOLTAGE EFFICIENCY CHECKED BY: S.T. CURRENT CURRENT STAMPED BY: S.W. SOLAR EDGE P340 340W 25 15A 13.75A 48V 98.8% UTILITY:EVERSOURCE PE STAMP WITH SIGNATURE INVERTER MAX CEC MAKE& Q� AC GROUND RATED OUTPUT MAX INPUT MAX INPUT WEIGHTED MODEL VOLTAGE POWER CURRENT CURRENT VOLTAGE EFFICIENCY SOLAR EDGE ,. 1 240V FLOATING 7600W 32A 20A 480V 99% 7600 H-US RAIL AND MOUNTS RAIL RAIL MOUNTS TYPE LENGTH #OF RAILS #OF #OF MID #OF END #OF MODEL MOUNTS CLAMPS CLAMPS GLUGS ULTRA PAGE DESCRIPTION SNAPNRACK BL C COMPI KIT BLACK 140 ALL 'EACH 13 60 44 20 10 PV BILL OF MATERIALS - SUMMIT ENERGY INSTALLATION AGREEMENT & WARRANTY SITE: 39 Swift Brook Rd Yarmouth MA, 02664 Summit Energy Group g ' • - - - ' ', ET `'II. fr .....,. ,4i.' ' ' ' - ' - ' - . . ; ..,, . - 1: ,f,,,,,;,4,:.,.,,rili.' a� E?ziri.,76, SUMMIT ENERGY GROUP I 293 Libbey Industrial Pkwy 4250,Weymouth,MA 02189 SOLAR INSTALLATION CUSTOMER & SYSTEM INFO Summit Energy Group CUSTOMER INFORMATION First Name: Lillian Last Name: Spain Customer 2 Name: Customer 2 Last Name: Cell Phone: (774) 722-2945 Alt Phone: Email: Address: 39 Swift Brook Rd cookiespainll@gmail.com City: Yarmouth State: MA Zip: 02664 AGREEMENT DETAILS You are entitled to a completely filled in copy of this agreement, signed by both you and the contractor, before any work may be started. Total Purchase Price: $60,433.33 Down/Upfront Payment: $ 0.00 Amount Financed: $60,433.33 Anticipated Finance Partner: Mosaic SCHEDULE OF PROGRESS PAYMENT(S): See Exhibit A(attached). ESTIMATES:Associated proposal(s)indudes estimates for approximate production,incentives,rebates,etc.for your project.These are good faith estimates.Summit employs knowledgeable representatives and uses best in class tools and software to be as accurate as possible. PREP SERVICES LIST:Prep work and services will be completed to fulfill a turn-key solar installation. If any unusual items arise outside of the normal scope of work,a change order will be provided and discussed with the customer. ACCEPTANCE OF DESIGN:By signing this agreement you agree with the design and layout of the proposed system that has been presented and understand that minor adjustments may be necessary upon further assessment of your property.If changes that are deemed not minor are required to complete the project,a change order form will be sent to both parties for agreement. EQUIPMENT LIST: Module Type: REC 330 or Tier I Equivalent Storage Type: Number of Modules: 25 Model: Inverter Type: SolarEdge HD or Equivalent Qty: Mounting: Roof ❑X Ground ❑ .NocaExtended two tawaonotapytoenemy ohmagsolutions, Extended Warranty: ❑ Page 2 of 8 CONTRACT PROVISIONS representation or warranty is expressly set forth in this contract or a written amendment hereto signed by an official 1) PROJECT COMPLETION, (aka Substantial Completion) is representative of Company. considered attained upon permit sign-off by a representative of 4.CANCEL.If,after the 3 day right of rescission has passed,the the local Authority Having Jurisdiction (AHJ). Utility meter customer cancels this contract, a minimum charge of$500 will installation is beyond the control and responsibility of Summit be assessed to the Customer.If additional time has passed and Energy(known as'Company'throughout this agreement)and further work has been done on the project,a greater fee will be its representatives.While these Electric Utility provided services assessed in the event of cancellation. typically occur within 7 to 56 days of permit sign-off,Company is not responsible for a timely response by the Electric Utility. 5. DEFAULT. Upon a default by Customer, Company may elect All payments to Company are due upon Project Completion. to treat this contract as canceled,in which case all amounts due to Company shall be immediately due and payable. If Customer 2)TOTAL PURCHASE PRICE includes any applicable taxes to does not pay all amounts due to Company within a 7-day grace complete the project. period, then Customer shall pay Company interest on the amounts due at the lesser of twenty-four percent(24%)or the 3)All MAJOR COMPONENTS are covered by the manufacturers' maximum amount allowable under applicable law, and all warranties. collection costs, including reasonable attorneys' fees. In 4) addition, Customer shall pay Company$30.00 for each check, SUBJECT TO AVAILABILITY. Final system details may differ slightly depending on module availability and final design. debit or credit card payment which is dishonored for any reason. 5) NO GUARANTEE. The electricity generation figures are an 6.NOTICE TO OWNER. FAILURE OF THIS CONTRACTOR TO PAY THOSE PERSONS SUPPLYING MATERIAL OR SERVICES TO estimate based on historical increases in electridty rates; COMPLETE THIS CONTRACT CAN RESULT IN THE FILING OF A Company makes no guarantee on future increases in rates. MECHANIC'S LIEN ON THE PROPERTY WHICH IS THE SUBJECT 6) BEST ESTIMATE. Company attempts to give you a best OF THIS CONTRACT PURSUANT TO CHAPTER 429, RSMO.TO estimate on the completions Coinstallation.Hgive due to the AVOID THIS RESULT, YOU MAY ASK THIS CONTRACTOR FOR "LIEN WAIVERS" FROM ALL PERSONS SUPPLYING MATERIAL multiple external factors governing the utility, permitting, OR SERVICES FOR THE WORK DESCRIBED IN THIS CONTRACT. installation and inspection processes which are outside of the FAILURE TO SECURE LIEN WAIVERS MAY RESULT IN YOUR control of Company, Company does not guarantee installation PAYING FOR LABOR AND MATERIAL TWICE. project dates in any circumstance. 7)FINAL SIZE.The final size of the system is subject to module 7.COSTS AND EXPENSES. Notwithstanding anything to the availability,which may differ slightly by(+/-) 5%.Any costs for contraryingout ofherthis in the event of any litigation or arbitration all award arising of contract,the court or arbitrator(s)shall award electrical service upgrades that may be required as part of the to the prevailing party all reasonable costs and expenses, project are the responsibility of the customer. including attorneys'fees incurred in the prosecution or defense of such action, whether at trial, upon appeal, or in connection ADDITIONAL CONTRACT PROVISIONS with any petition for review. In addition,the court or arbitrator shall award the prevailing party all reasonable attorneys' fees 1.PAYMENT DUE DATE(S).All payments are due from customer and costs to collect the judgment or award. to Company upon completion of the events described in the payment schedule in this agreement. 8.INVALID PROVISIONS.If any part(s)of this contract is found to be invalid or illegal,it shall not affect the rest of this contract, 2.TOTAL PRICE. The total installed system price which shall continue in full force and effect as if said part(s)was includes any applicable taxes and fees. not included herein this agreement. 3.DISCLAIMER AND EXCLUSIONS. Company disclaims and 9.MODIFICATION OF THIS CONTRACT. No subsequent customer releases from any liability for incidental or modification procedures of any of the terms of this contract shall consequential damages arising from the services and products be valid, biding upon the parties,or enforceable unless made in purchased by customer pursuant to this contract. Customer writing and signed by appropriate representatives of each party. further waives any right to recover punitive damages from Company. To the extent allowed by applicable law, Company 10.AGENCY. If Customer is more than one person or legal disdaims,and customer waives all other expressed and implied entity,each of them does hereby irrevocably authorize the other warranties relating to any products sold or delivered to Customer of them in his or her name, or as his or her agent. in dealings pursuant to this contract,including but not limited to,the implied with Company, to do, to execute or to perform any act, deed. warranties of merchantability and fitness for a particular matter or thing whatsoever with reference hereto, or with purpose, and any rights or remedies created by any state or reference to the improvements to the property,and does hereby federal statutory, regulatory or case law, including but not ratify and confirm all that such agent may do by virtue thereof. limited to the Magnuson-Moss warranty act. Customer acknowledges and agrees that Company has not made and will 11.OTHER REBATE INFORMATION.The availability and amount not be responsible for any representation or warranty,whether of the incentives listed in relation to this contract can change verbal, in writing or implied by action or example, unless such often and without notice. Company will attempt to inform Page 3 of 8 • . Customer of any changes; however, Company and its added or subtracted from the contract,and the effect the order representatives cannot guarantee any rebates or incentives. will have on the schedule of progress payments, if any. We recommend that you consult with a lawyer or tax professional to learn more about your eligibility for the Federal 14.ENTIRE CONTRACT.This contract(including any documents Residential Renewable Energy Tax Credit and appropriate incorporated by reference herein) constitutes the entire resources regarding any other applicable incentives. This agreement between the parties with respect to the subject contract is not conditioned on your ability to get any rebates, matter hereof. This contract supersedes all previous or incentives or credits.Some financial incentives may be treated contemporaneous agreements and understandings with regards as income by tax authorities depending on your tax status. to the subject matter hereof,whether written or oral. Company and its representatives are not authorized to provide tax advice. 15.PROPERTY RELEASE. Customer grants Company the right and permission to photograph the exterior of the Property for the 12.CHANGE ORDERS. If you want to change our regular duration of Company's scope of work, and to use, reuse, and procedures for installing your system or have extra work done, publish, in any manner, such photographs, in whole or in part, your request shall be reflected as a modification to the scope either by themselves or in conjunction with other photographs, of work of this contract. in any medium or form of distribution,and for any commercial or promotional purpose. Upon written request by Customer that 13.EXTRA WORK AND CHANGE ORDERS. Extra work and Company cease using such photograph(s), Company will use change orders become part of the contract once the order is reasonable efforts to cease such use within a reasonable period prepared in writing and signed by both parties.The order must of time. describe the scope of the extra work or change,the cost to be Total Purchase Price: System Size(kW): $60,433.33 8.25 Customer Name: Customer Signature: Date: Lillian Spain „,,'«;;;;L,�,b` i;;;1c66531352�073363Y1 June 24, 2021 Customer 2 Name(if required): Customer 2 Signature: Date: Company Representative: Company Representative Signature: Date: Kris O'connell Xi& U'e wave Sae37NM Oc49f5ebNOSeaUfcbd4dOcY7b52c22YJune 24, 2021f0 Page 4 of 8 NOTICE OF RIGHT TO CANCELLATION Customer Copy Summit Energy Group Transaction Date: 06/24/21 You may CANCEL this transaction,without any Penalty or Obligation,within THREE BUSINESS DAYS from the above date. If you cancel,any property traded in,any payments made by you under the contract or sale,and any negotiable instrument executed by you will be returned within TEN BUSINESS DAYS following receipt by the seller of your cancellation notice,and any security interest arising out of the transaction will be canceled. If you cancel,you must make available to the seller at your residence, in substantially as good condition as when received, any goods delivered to you under this contract or sale, or you may, if you wish, comply with the instructions of the seller regarding the return shipment of the goods at the seller's expense and risk. If you do make the goods available to the seller and the seller does not pick them up within 20 days of the date of your Notice of Cancellation,you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller,or if you agree to return the goods to the seller and fail to do so,then you remain liable for performance of all obligations under the contract. To cancel this transaction,mail or deliver a signed and dated copy of this Cancellation Notice or any other written notice,or send a telegram,to Summit Energy Group,at 293 Libbey Industrial Pkwy#250,Weymouth, MA 02189 NO LATER THAN MIDNIGHT OF THE THIRD BUSINESS DAY FROM THE DATE OF TRANSACTION. I HEREBY CANCEL THIS TRANSACTION. Date: Buyer Signature: Buyer Name: Page 5 of 8 NOTICE OF RIGHT TO CANCELLATION Company Copy Summit Energy Group Transaction Date: 06/24/21 You may CANCEL this transaction,without any Penalty or Obligation,within THREE BUSINESS DAYS from the above date. If you cancel, any property traded in,any payments made by you under the contract or sale,and any negotiable instrument executed by you will be returned within TEN BUSINESS DAYS following receipt by the seller of your cancellation notice, and any security interest arising out of the transaction will be cancelled. If you cancel,you must make available to the seller at your residence, in substantially as good condition as when received,any goods delivered to you under this contract or sale, or you may, if you wish, comply with the instructions of the seller regarding the return shipment of the goods at the seller's expense and risk. If you do make the goods available to the seller and the seller does not pick them up within 20 days of the date of your Notice of Cancellation,you may retain or dispose of the goods without any further obligation.If you fail to make the goods available to the seller, or if you agree to return the goods to the seller and fail to do so,then you remain liable for performance of all obligations under the contract. To cancel this transaction, mail or deliver a signed and dated copy of this Cancellation Notice or any other written notice,or send a telegram,to: Summit Energy Group,at 293 Libbey Industrial Pkwy#250,Weymouth,MA 02189 NO LATER THAN MIDNIGHT OF THE THIRD BUSINESS DAY FROM THE DATE OF TRANSACTION. I HEREBY CANCEL THIS TRANSACTION. Date: Buyer Signature: Buyer Name: Page 6 of 8 SUMMIT ENERGY WORKMANSHIP WARRANTY Summit Energy Group WORKMANSHIP DEFECTS: Company warranty shall be limited to defects in Workmanship within the scope of work performed by Company and which arise and become known within ten (10) years from the date of transaction. All said workmanship defects arising after ten(10)years and defects in products installed by Company are not warranted by Company. SOLAR PV SYSTEMS: Company's warranty for installation and workmanship of solar PV systems installed by Company shall be from ten(10)years from the date of transaction. CONDITIONS OF WORKMANSHIP: This warranty shall be limited to defects in workmanship in the scope of work performed by Company and which arise and become known within ten (10) years from date of transaction. Defects in workmanship arising after ten years are not warranted by Company.Company agrees to remedy the defective workmanship without charge within a reasonable time upon notice. During the term of this warranty, Company will facilitate the troubleshooting, removal, shipping, repair, and re-installation of defective equipment or parts that are covered under the manufacturer's warranties per manufacturer's guidelines and procedures.Company hereby assigns to Customer all warranties on products as provided by the manufacturer(s). Company will not be liable for injury to persons or damage to building or contents, or for incidental, special or consequential damages for breach of any written or implied warranty on defects in workmanship.This warranty covers roof penetrations from your solar installation,that they will be water-tight for a period of ten (10)years following the date of installation. EXCLUSIONS FROM WARRANTY COVERAGE:This warranty does not apply to a System if the defect,determined by Company, is a result of any of the following: 1)Trees, new buildings,or other array obstructions are installed,grow beyond the point of the original array install,or otherwise change or damage,and negatively affect production during the ten-year term. 2)Improper use, installation,wiring, handling,removal, storage, maintenance,or cleaning of the System or any monitoring devices by someone not authorized or employed by Company. 3)Damage due to installation at a location where conditions deviate from the standard operating conditions set forth in the User Guide(i.e. lack of airflow, saltwater). 4)Damage from abuse,alteration,or vandalism,or due to plants, insects,or animals. 5)Damage from external stress, impact, foreign objects, or falling rocks,debris or anything of like nature. 6)Damage or corrosion caused by roofing materials,chemicals,or substrates, including those used for corrosion resistance,thermal expansion and contraction,and moisture barriers and sealing. 7)Power or voltage surges or damage caused by the electrical grid for shore power connected products. 8)Natural disasters, earthquakes, fires, typhoons, tornadoes, hurricanes, volcanic activity, volcanic douds, dust storms, dust clouds, floods, tsunamis, lightning, other acts of God, or other events that are beyond the reasonable control of Company. 9)Acts of terrorism,criminal acts, riots,wars,civil unrest, nuclear radiation,or man-made disasters. 10)Damages attributable to normal weathering or defects or damages caused by vapors or chemical pollutants or air pollution, building settlement or structural failure of roof,walls,foundations or any part of the attached structure,or any other causes beyond Company control. Page 7 of 8 , EXHIBIT A SCHEDULE OF PAYMENTS Summit Energy Group ADDENDUM TO SUMMIT ENERGY INSTALLATION AGREEMENT&WARRANTY This, Exhibit A,is an Addendum to the Summit Energy Installation Agreement&Warranty,attached("Agreement").This Addendum is part of the Agreement. In the event of a conflict between the terms of this Addendum and the other portions of the Agreement,the terms of this Addendum shall prevail and supersede any conflicting terms. The Customer(s)and Company agree that the payment schedule for the contract amount to be paid will be as follows: $[50%]down payment due on completion of customer agreement to commence project. $[50%]due upon substantial completion of work. Additional notes: IF THE PROJECT IS FINANCED THROUGH ONE OF THE COMPANY'S APPROVED FINANCING PARTNERS, THE PAYMENT SCHEDULE WILL ALIGN WITH THE DISBURSEMENT BENCHMARK(S)AND TERMS AGREED TO BETWEEN COMPANY AND THE FINANCE PARTNER USED.IF CIRCUMSTANCES ARISE,FOR ANY REASON,AND THE FINANCE PARTNER IS UNABLE TO OR DOES NOT MAKE THE REQUIRED PAYMENT(S) AS SET FORTH TO FULFILL THIS AGREEMENT,THIS AGREEMENT IS BETWEEN CUSTOMER AND COMPANY, AND ANY REMAINING AMOUNT DUE WILL BE OWED ULTIMATELY FROM CUSTOMER TO COMPANY UPON NOTICE IN ORDER TO SATISFY ANY OUTSTANDING BALANCE DUE ON THE TOTAL PURCHASE PRICE. Customer: Customer Signature: Date: Lillian Spain list June 24, 2021 wo.oiw.o> L76ufJ/t.xoesaaas<er.>aoaoa Customer 2(if required): Customer 2 Signature: Date: Company Representative: Company Representative Signature: Date: Kris O'connell Xiss C'e044411 June 24, 2021 aw s i reuceaemeue.u,eesercoareu.e w cc«eru Page 8 of 8 RI Contractors Registration#43417 MA CSL#CS-113982