Loading...
HomeMy WebLinkAboutBLDE-22-001661 DIRECTORY NEW PV SYSTEM: LAURE PIERRE PV, T SUMMARY NOTES PV2 NOTES 40 CAPTAIN BACON RD, SOUTH YARMOUTH, MA 02664, USA PV3 PLOT PLAN PV4SITEPLAN (42.683260, -71 .341675) Z2L PV5 ATTACHMENT DIAGRAM PV6 ATTACHMENT DETAILS&ELEVATION PV7 THREE UNE DIAGRAM PV SYSTEM RATING (DC): 18.15 KW PVS BILL OF MATERIALS _ PV9 WARNING LABELS PV10-PV13 DATA SHEETS 1/.1' ra 1.. SYSTEM INFORMATION et:. ', y� f, DC SYSTEM SIZE 18.15 KW _ Pi•. EPC COMPANY: AC SYSTEM SIZE 15 KW + SUMMIT ENERGY GROUP DC/AC RATIO 1.21 _ - `�"'0 293 IJBBEY INDUSTRIAL PKWY, MODULE REC TWIN PEAK SERIES ' ,. p ^+F.. - UNIT 250,WEYMOUTH, BLACK,3307P3M,330W ' 1. MA 02189,USA SOLAREDGE TECHNOLOGIES, +'., 858-5784648 MLPEANVERTER P340,(1)SE10000H-Us,(2) _.... €..y .'.s --' www.6uRlmltsolironergy.Com SE5000H-US - RACKING IRONRIDGE � ( . CUSTOMER DETAILS ATTACHMENTS FLASH FOOT 2 I TOTAL ARRAY AREA 990 SOFT. - - �` .` j NO.OF MODULES 55 - es ARRAY 1 AZIMUTH 181' rT- ARRAY 1 PITCH 30' a a' W Z N d Z ARRAY 2 AZIMUTH 271' d p Z 0 F ARRAY 2 PITCH 30' •''' W W Q coI ARRAY 3 AZIMUTH 81' • M a. 03 Z (— ARRAY 3 PITCH 30' - -_L �'" � �` i Z Z g ARRAY 4 AZIMUTH 91' ' r�, '_� H 0 W ARRAY 4 PITCH 30' 0_ ARRAY 5 AZIMUTH - ... Z et ARRAY 5 PITCH - 0 AVERAGE TSRF - U11UTYNAME EVERSOURCE 0 AERIAL VIEW 4311 STREET VIEW PROJECT ID:MAEVE18.15-958 REMOTE YES NOT TO SCALE NOT TO SCALE PREPARED ON:09/14/2021 MONITORING DRAWN BY: V.N. SITE DETAILS INTERCONNECTION DETAILS CHECKED BY: S.T. ASHRAE EXTREME LOW 3.2'F(-16'C) NEW SUPPLY SIDE AC STAMPED BY: S.W. ASHRAE 2%HIGH 82.4.928.0) DESIGN ENGINEER POINT OF CONNECTION CONNECTION PER NEC UTILITY:EVERSOURCE CLIMATE DATA BARNSTABLE MUNI BOA, I I N SIDDHARTH TEMBURNI NABCEP PVIP CERTIFIED UTILITY SERVICE 120/240V 1�ARTICLE 705.12(Aj PE STAMP WITH SIGNATURE SOURCE MA,USA(WMO:725067) I I 310®SUMMIT.SOLAR 100A MAIN BREAKER,125A WIND SPEED 141 MPH(ASCE 7-10) ELECTRICAL PANEL PANEUBUSS t1� I I I SCOTT PROFESSIONAL ENGINEER WYSSUNG MODE OF INTERCONNECTION BTM,LINE SIDE TAP RISK CATEGORY II .� BI I WIND EXPOSURE ♦ICATEGORY . W CONSULTING SERVICE ENTRANCE OVERHEAD _ ?.. '� GROUND SNOW LOAD 30 PSF P.E.STRUCTURAL,PP,CME �� ,VI H L_____J (0):(201)874-3483 DOCUMENT DESCRIPTION °50 APPLICABLE CODES&STANDARD 8 THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF 1 T "`�� MASSACHUSETTS BUILDING DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER/ 'AFSSIpNpL BUILDING CODE,9TH EDITION,AS AMENDED SYSTEM WITH ODEENOS AND DETAIL TO IONS.DEMOTHE DOCUMENTC COMPLIANCE NO- / y SCOPE OF WORK APPLICABLE CODES REGULATIONS.THE SHALL NO' [,✓�' (760 CMR) BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER THIS PROJECT INVOLVES THE INSTALLATION OF SOLAR PANELS.THE INSTALLATION INSTRUCTIONS.CONTRACTOR SHALL INSTALL MASSACHUSETTS ELECTRICAL SOLAR PANELS WILL BE RACKED USING A PRE-ENGINEERED RACKING EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC AND NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY PAGE DESCRIPTION ELECTRICAL CODE(527 CMR 12.00)NFPA 70E PLOT MAP 0TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCALpV 1 (2017NEC) UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES VERIFICATION OFALL CONDITIONS,CONTRACTOR ENSIONS,AND DETAILS IN THIS MASSACHUSETTS COMPREHENSIVE NOT TO SCALE FIRE ENFORCED BY THE LOCAL UTIUTY AND PERMITTING JURISDICTION. DOCUMENT. FIRE SAFETY CODE(527 CMR 1.00) PROJECT SUMMARY ( L1E2 -L -- oo (( ( 2.1.1 SITE NOTES: LEGENDS 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 REGULATIONS. THROUGH 250.106.IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,A 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM ISA GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. AND AHJ. _Cl.._ AZ2L 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR 2.4.10 ACCORDING TO NEC 690.47(C)(3),UNGROUNDED SYSTEMS INVERTER MAY SIZE DC A JUNCTION BOX BUILDING ROOF VENTS. GEC ACCORDING TO EGC REQUIREMENTS OF NEC 250.122.HOWEVER,DC DEC TO BE _L:3__ 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED UNSPLICED OR IRREVERSIBLY SPLICED. _Ca-_ ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 2.4.11 IN UNGROUNDED INVERTERS,GROUND FAULT PROTECTION IS PROVIDED 2.1.6 ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN BY"ISOLATION MONITOR INTERRUPTOR.AND GROUND FAULT DETECTION [a ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S PERFORMED BY"RESIDUAL-CURRENT DETECTOR.' INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE 2.5.1 INTERCONNECTION NOTES: BUILDING OR STRUCTURE. 2.5.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 690.64 / 2.2.1 EQUIPMENT LOCATIONS (B)] 222 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 11026. 2.5.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED EXCEED 120%OF BUSBAR RATING[NEC 705.12(DX2X3)]. PV INVERTER EPC COMPANY:OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C)AND NEC TABLES 2.5.4 WHEN SUM OF THE PV SOURCES EQUALS>100%OF BUSBAR RATING,PV 310.15(BX2XA)AND 910.15(BX3XC). DEDICATED BACKFFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE " SUMMIT ENERGY GROUP 22.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(DX2X3)} Q ACCORDING TO NEC 690.34. 2.5.5 AT MULTIPLE INVERTERS OUTPUT COMBINER PANEL,TOTAL RATING OF ALL 4 . 0 on 2.2,4 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR 293 UBBEY INDUSTRIAL PKWY, WITHIN SIGHT OF THE AC SERVICING DISCONNECT. HOWEVER THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED UNIT 250,WEYMOUTH, 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC 705.12(DX2X3XC). UNE MA 02189,USA ACCORDING TO NEC APPUCABLE CODES. 2.5.6 FEEDER TAP INTERCONECTION(LOAD SIDE)ACCORDING TO NEC 705.12 888-578-884822.6 ALL COMPONENTS ARE USTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR (01(2x1) o o NON FUSIBLE USAGE WHEN APPROPRIATE 2.5.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH )11 AC DISCONNECT www.summMsolaroMTSTI•eOm 2.3.1 STRUCTURAL NOTES: SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.3.2 RACKING SYSTEM&PV ARRAY WILL BE INSTALLED ACCORDING TO 2.5.6 BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS LOAD CUSTOMER DETAILS CODE-COMPLIANT INSTALLATION MANUAL TOP CLAMPS REQUIRE A EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12(DX5X. DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A 26.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: I MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, 2.62 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO UNE o O I-V TERMINALS).2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS. THE TERMINALS MARKED'LINE SIDE'(TYPICALLY THE UPPER 0> co es IF ROOF-PENETRATING TYPE,IT SHALL BE FLASHED&SEALED PER LOCAL 26.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL BE FUSIBLE W N REQUIREMENTS. LOCKABLE.AND BE A VISIBLE-BREAK SWITCH. AC DISCONNECT K W O 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND 2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED. W Z re N d 2 SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED THEREFORE BOTH MUST OPEN WHERE A DISCONNECT IS REQUIRED, LOADn-t D_W ZO Q op Z CONTRACTOR. ACCORDING TO NEC 690.13. W uj 0 0 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 2.6.5 DC DISCONNECT INTEGRATED INTO ROOFTOP DC COMBINER OR INSTALLED re- Q< n W SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER WITHIN 8 FT,ACCORDING TO NEC 690.15(C). D W m S F 2.3.6 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE 2.8.6 RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY 5 ce Z 1- Z 5 STAGGERED AMONGST THE ROOF FRAMING MEMBERS. OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS.CONTROLLED 0 UTILITY/NET METER Q O 0 0- 24.1 GROUNDING NOTES: CONDUCTORS 530V AND S240VA(NEC 890.121.LOCATION OF LABEL BIDIRECTIONAL 2 _ 2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND ACCORDING TO AHJ. IZ 0- LI GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH 2.6.7 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 890.8,690.9, 0} Z USE. AND 240. 2.4.32.6.8 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED,AS IN CONVENTIONAL PV SYSTEMS,UNGROUNDED PV SYSTEMS REQUIRE AN 410. U 0 EQUIPMENT GROUNDING CONDUCTOR.ALL METAL ELECTRICAL EQUIPMENT AND THEREFORE BOTH REQUIRE OVER-CURRENT PROTECTION,ACCORDING TO STRUCTURAL COMPONENTS BONDED TO GROUND,IN ACCORDANCE WITH 250.134 OR NEC 240.21.(SEE EXCEPTION IN NEC 690.9) �11�� UTILITY ELECTRIC 250.136(A).ONLY THE DC CONDUCTORS ARE UNGROUNDED. 2.6.9 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION �., GRID PROJECT ID:MAEVE18.15-958 2.4.4 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM ACCORDING TO NEC 890.11 AND UL1699B. ,, PREPARED ON:09/14/2021 NEC TABLE 250.122. 2.7.1 WIRING&CONDUIT NOTES: 2.4.5 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ENCLOSURE 2.7.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. DRAWN BY: V.N. CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.138(A). CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE ^ CHECKED BY: S.T. 2.4.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CUPS AS SHOWN IN REQUIREMENTS AND ARE NOT MEANT TO UMIT UP-SIZING. MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ.IF WEEBS ARE 2.7.3 ALL CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 680.7. STAMPED BY: S.W. NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED 2.7.4 EXPOSED UNGROUNDED PV SOURCE AND OUTPUT CIRCUITS SHALL USE WIREUTILITY:EVERSOURCE GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION USTED AND IDENTIFIED AS PHOTOVOLTAIC(PV)WIRE[690.35(DX.PV `1 Y 1/ UTILITY/NET METER REQUIREMENTS. MODULES WIRE LEADS SHALL BE LISTED FOR USE WITH UNGROUNDED BIDIRECTIONAL PE STAMP WITH SIGNATURE 2.4.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT SYSTEMS,ACCORDING TO NEC 890.35(0X3). WITH METER MAIN THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO 2.7.6 PV WIRE BLACK WIRE MAY BE FIELD-MARKED WHITE[NEC 200.6(AX6)]. ANOTHER MODULE 27.6 MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. %t1A OF 248 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLORED 27.7 ACCORDING TO NEC 200.7,UNGROUNDED SYSTEMS DC CONDUCTORS a GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] ' '' -i 11 11 COLORED OR MARKED AS FOLLOWS: '.. j FIRE SETBACK I 0 ATTAHING DC/DC CHMENT + OPTIMIZERS POWER a�y DC POSITIVE-RED,OR OTHER COLOR EXCLUDING WHITE,GREY AND /� DC NEGATIVE-BLACK,OR OTHER COLOR EXCLUDING WHITE,GREY SOLAR MODULES STRINGS I EGC&GC BONDED AND / \�A��' /V AND GREEN ROOF/GROUNDTHE __.-__._BLACK RAL = GROUNDED ( 2.7.8 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: -,-- PHASE A OR LI-BLACK R BACK FEED _ 1=1 PHASE B OR U-RED,OR OTHER CONVENTION IF THREE PHASE RESIDENTIAL - PHASE C OR L3-BLUE,YELLOW,ORANGE',OR OTHER CONVENTION 1t 12 BREAKER 000 PRODUCTIONTTESLA BATTERY OPTION PAGE DESCRIPTION NEUTRAL-WHITE OR GREY .. .. ELECTRIC D I METER -4 F -I r/ `, /� •IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE O WIRE TAPS PV L TO BE MARKED ORANGE[NEC 110.15]. GENERAL PROJECT NOTES NOTE:THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS.THE DOCUMENT SHOULD NOT BE REUED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS.INSTALLER SHALL INSTALL ALL EQUIPMENT IN -11.10'-- ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS.NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. T ieLIA EPC COMPANY: N. SUMMIT ENERGY GROUP N rINVERTER /^' 293 LIBBEY INDUSTRIAL PKWY, UNIT 250,WEYMOUTH, -SMART METER DMA 02189,USA 888.578.8848 -AC DISCONNECT www.summltsolarenergy.com o -UTILITY/NET METER "a CUSTOMER DETAILS �--16. 0 --ter �a 0 iz-#--MAIN SERVICE PANEL m c N a; `, I(INSIDE) w I �•AC DISCONNECT �� w z te ig d z ARRAY 1--4 I (INSIDE) w- Uz M M #4,REC 330W #4,SE P340 N La -t-'--ARRAY 4 m Li m - `� TILT 30° e N #5,REC 330W g Z 8 z 0. I #5,SE P340 = w TILT 30° D- w IMP ---13.20' -- .<} i IQ D ( PROJECT ID:MAEVE18.15-958 T 0 PREPARED ON:09/14/2021 0 DRAWN BY: V.N. CHECKED BY: S.T. STAMPED BY: S.W. '4r. Z UTILITY:EVERSOURCE a) N C1 N PE STAMP WITH SIGNATURE 01 Ol ARRAY 2--- ARRAY 3 0 W I— E ' / to -• -�----I-- #34,REC 330W #12,REC 330W / \ :� �" #34,TILTSE P340 f #12,SE P340 • ' ed � 30° SroNAti ----17.10'--- - ----17.10'-----a.... TILT 30° S ® €1 0 PLOT PLAN SCALE:,'O°_ PAGE DESCRIPTION ,'O" PV 3 PLOT PLAN NOTE 1:EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED -11.10'--0 SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM t WORKING CLEARANCES PER NEC 110.26. $ NOTE 2:CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE.. NOTE 3:CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL RELATED _ EQUIPMENT,CABLES,ADDITIONAL CONDUITS,BOXES, ZL. RACEWAYS,AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. a NOTE 4:THE SYSTEM SHALL COMPLY WITH NEC ARTICLE 690,ALL 1-2 ,r. MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, ,: AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY a 611 HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. O NOTE 5:WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN EPC COMPANY: INSIDE THE BUILDING,THEY SHALL BE CONTAINED IN METAL ® SUMMIT ENERGY GROUP RACEWAYS,TYPE MC METALCLAD CABLE,OR METAL ENCLOSURES FROM THE POINT OF PENETRATION INTO THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING o ; 293 UBBEY INDUSTRIAL PKWY, MEANS,PER NEC 690.31(G) UNIT 260,WEYMOUTH, NOTE 6:ABOVE DIMNSSIONS ARE FOR THE RESPECTIVE ROOF PLANES -1" E+ 16.00' MA 02189,USA MEASURED BETWEEN THE ROOF RIDGE TO THE EVE AND RAKE TO RAKE ISS ( 888-578-6648 LEGENDS: ISti9: r1 www.summItsolareneray.coms 1 CUSTOMER DETAILS O EXISTING UTILITY METER 1 ARRAY 1--I -1-2- = 79 MAIN SERVICE PANEL #4,REC 330W b - T-ARRAY4 n g CDg—I AC DISCONNECT #4,SE P340 N r #5,REC 330W y D a, as TILT 30° i #5,SE P340 w p FIRE CLEARANCE i TILT 30° w z re os c z Q INVERTER 1&2 UN ---13.20'-- Z coSF Iilla w2 .c ,� g © JUNCTION BOX REC 330W I. n� COx W O _STRINGS,MINIMUM 8 MODULES AND MAX SYSTEM INFORMATION 5 Z= z —8000W PER STRING;10KWAC AND 5KWAC a w ° 1. DC SYSTEM SIZE 18.15 KW c} z m 1"MODULE CLEARANCE b AC SYSTEM SIZE 15 KW v p L 1-1 REC TWIN PEAK SM MA SMART METER I.1 co MODULE SERIES BLACK, PROJECT ID:MAEVE18.15-958 I N 330TP3M,330W PREPARED ON:09/14/2021 1-1 SOLAREDGE DRAWN BY: V.N. OPTIMIZER& TECHNOLOGIES,P340, CHECKED BY: S.T. ARRAY 2-- ----r-ARRAY 3 INVERTER (1)SE10000H-US,(2) STAMPED BY: S.W. #34,REC 330W #12,REC 330W SE5000H-US UTILITY:EVERSOURCE + - 3.2T #34,SE P340 $ t #12,SE P340 TOTAL ARRAY PE STAMPWmISGNATURE ' I 990 SQ.FT.TILT 30° TILT 30° AREA ---17.10' •=--.1----17.10----B.- TOTAL NO.OF 55 NOP v MODULES �T� Lo ® Se ARRAY 1 AZIMUTH 181° y `/ 1 F� ARRAY 1 PITCH 30° REC T-PEAK BLACK SERIES, REC330TP3M,330W ARRAY 2 AZIMUTH 271° ' N ARRAY 2 PITCH 30° / `rec. (9 / NOTE THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO � ' ARRAY 3 AZIMUTH 91° DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODESAND REGULATIONS.THE p B SITE PLAN ARRAY 3 PITCH 30° _ DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWINGNow- 0 MANUFACTURER INSTALLATION MANUALS INSTALLER SHALL INSTALL ALL EQUIPMENT IN /1 � SCALE:1'0"=1'0" ARRAY 4 AZIMUTH 91° PAGE DESCRIPTION ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS.NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN ARRAY 4 PITCH 30° PV 4 MANUFACTURER INSTALLATION MANUALS. 5 UTILITY NAME EVERSOURCE SITE PLAN 42 a 12 1 LrALA 45 Lchi r z a a n. ca b N z COMPANY: COMBINER PANEL EPC COMPAN P 0 SUMMIT ENERGY GROUP 293 UBBEY INDUSTRIAL PKWY, 2X8 RAFTERS©16"O.C.i ti 2 UNIT 250,WEYMOUTH, MA 02189,USA 888478.8648 a 0 + --13,-e.-- www.summItsolarone►gy.eom _ P P CUSTOMER DETAILS _ 1 a I ARRAY 1-+` 41 I El 1- #4,REC 330W I $ $ $ IIIII —ARRAY 4 w #4,SE P340 °0 s s . a s &. a #5,REC 330W K o it` it t� z TILT 30° P ill #5,SE P340 0.W z o : p. a a s I ElsTILT 30° it y o§ n ag a'e a 5 w p . a gx I. cd � z 0. a P <8 o o. LEGENDS a - N 2 a tu IRONRIDGE XR100 BLACK a e P a 1 0} z Q q4 0 00 a I �~ D 0 d [ e O] IRONRIDGE FLASH FOOT 2 P P • 4 0 PROJECT ID:MAEVEI8.15 958 111 a 0 0- PREPARED ON:09/14/2021 p ® P DRAWN BY: V.N. CHECKED BY: S.T. DEAD LOAD CALCULATIONS a--a P e o + STAMPED BY: S.W. LOAD QTY. LBS. TOTAL LBS •a a B o UTILITY:EVERSOURCE MODULES 55 41 2255 .9_ PE STAMP WITH SIGNATURE OPTIMIZERS 55 1.70 94 • LINEAR FEET OF RAIL(ft.) 385 0.4 154 ARRAY 2---+� 0_ a p 4 a- a a P-0-----—ARRAY 3 _ FLASH FOOT 2 118 0.09 11 #34,REC 330W a U I a #12,REC 330W NOF \ #34,SE P340 a a a a a P #12,SE P340 \` SIMPLE GRIP-SQ 0 0.09 0 TILT 30° TILT 30° - /� ' MID CLAMPS 92 0.09 8 II�----14'---- ----14'----� e' '/ END CLAMPS 38 0.09 3 GROUND WEEBS 18 0.09 2 14 a MISC.HARDWARE 0 NOTE 1:DIMENSIONS IN RED INK MEASURES THE HORIZONTAL ' _ISA` TOTAL ARRAY WEIGHT 2526 DISTANCE BETWEEN RIDGE AND THE SIDE WALL � AREA NAME QTY. SCUT. TOTAL SQ.FT. NOTE 2:MOUNTS/ATTACHMENTS SHOULD BE INSTALLED AS PER ., MODULES TOTAL ROOF AREA 55 18 990.00 NOTE UFACTURERS 3:FLASHINGS ONCE INSTALLED TIONS - - . w INSTALLED SHOULD BE SEALED TO a ATTACHMENT P LAN %OF ROOF AREA COVERED BY SO PV(1-) WATER TIGHT �' '4., O SCALE:1'0"=1'0" PAGE DESCRIPTION POINT LOAD(TOTAL ARRAY WT./ATTACHMENTS),Lbs/Sq.ft. Y1 NOTE 4:IF THE ROOF IS DETERMINED TO BE WEEK AT THE PV 5 INSTALL,STOP THE WORK AND NOTIFY THE PROJECT ENGINEER DIST.LOAD(TOTAL ARRAY WTJTOTAL SO.FT.),Lbs/Sq.ft. 2.55 S ATTACHMENT DIAGRAM IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL PV MODULE FRAME IRONRIDGE UNIVERSAL FASTENING OBJECT FASTENING OBJECT PV MODULE FRAME IRONRIDGE UNNERSALor PV MODULEFRAME �� PV MODULE FRAME "�� IRONRIDGE UNIVERSAL CPFASTENING OBJECT I IRONRIDGE RAIL FASTENING OBJECT � IRONRIDGE STOPPER IRONRIDGE RAIL� SLEEVE 1 imp- EPC COMPANY: SUMMIT ENERGY GROUP 4 299 UBBEY INDUSTRIAL PKWY, UNIT 250,WEYMOUTH, MA 02189,USA 888.578-6848 www.summfsolarenerEy.Com CUSTOMER DETAILS IRONRIDGE FLASHING-\ j °j F e wzo F.. IRONRIDGE RAIL fill -� z CI Ill z o \ = .0_....0 �� 1 �, O W Ia SHINGLE ? \ �� a PROJECT ID:MAEVEI8.15-958 iii 1 :` VARIES PREPARED ON:09/14/2021 11 `� DRAWN BY: V.N. \ CHECKED BY: S.T. ` STAMPED BY: S.W. `\ \` UTILITY:EVERSOURCE �' 11 •``• PE STAMP WITH SIGNATURE •wilossii-------%:-.P..'n i \ -Of .',- ,v, ...,,, „. __ 0 : ' SSJONTs' V _ 1 : ,0 - e . _ `v PAGE DESCRIPTION PV6 ATTACHMENT DETAILS WIRE SIZING SCHEDULE WIRE ID GUAGE DESCRIPTION A 8 AWG THWN-2 COPPER EGC WIRE FROM JUNCTION BOX-GEC.#6 BARE CU WIRE ON THE ROOF BETWEEN THE RAILS B 10 AWG PV WIRE COPPER FOR 5 KW INV,MODULES-OPTIMIZERS-JUNCTION BOX C 10 AWG THWN-2 COPPER JUNCTION BOX TO 5 KW INVERTER B1 8 AWG THWN-2 COPPER FOR 10 KW INV,MODULES-OPT-JBOX Cl 8 AWG THWN-2 COPPER JUNCTION BOX TO 10 KW INVERTER ALL D 10 AWG THWN-2 COPPER UNE AND NEUTRAL WIRES FROM(5IcW)INVERTER-AC COMBINER PANEL E 6 AWG THWN-2 COPPER LINE AND NEUTRAL WIRES FROM(10kW)INVERTER-AC COMBINER PANEL F,G,H,I 3 AWG THWN-2 COPPER AC COMBINER PANEL-SMART METER-AC DISCONNECT-LINE SIDE TAP-GRID SYSTEM SUMMARY COMMUNICATION DIAGRAM STRING 1 I STRING 2 I STRING 3 STRING 1 I STRING 2 SINGLE INVERTER MULTIPLE INVERTERS SE 10000H-US SE 5000H-US EPC COMPANY: OPTIMIZER MAXIMUM OUTPUT CURRENT 15A 15A 15A 15A 15A SUMMIT ENERGY GROUP OPTIMIZERS IN SERIES 10 12 14 08 11 T ,40, Irg A • NOMINAL STRING VOLTAGE 480Vdc 480Vdc DC OPERATING CURRENT 51.95A ®" 'K ,, _. 293 ABBEY INDUSTRIAL PKWY, [illi E lr0 E r 4 /1 UNIT 250,WEYMOUTH, TOTAL ARRAY POWER 18,150Wdc/15,000Wac J MA 02189,USA COMMUNICATION SE 5 YR-GSM CELL KIT J�/� ,. yJ DAD,CAM OOZY OWN 888-578$&/8 INVERTER MAX INPUT DC/MAX OUTPUT AC 27Adc/42Aac 13.5Adr121Aac �"' J" www.aummksolaronaryy.com INVERTER MAX INPUT DC POWER 15,500W 7750W 0 T ALLOWABLE MIN/MAX STRING POWER MIN 8 MODULES IN SERIES/MAX 6000W MIN 8 MODULES IN SERIES/MAX r- CUSTOMER DETAILS IN A STRING 5700W IN A STRING BIDIRECTIONAL = 3 SOLAREDGE TECHNOLOGIES F-Q 8 SE 5000H-US,NEVA 3R UL 100A,240V NON FUSIBLE UTILITY METER M co SOLAR EDGE LISTED,INTEGRATED GFDI AND AC DISCONNECT 120240V O D g 50 P340 OPTIMIZER ,., DC DISCONNECT. MA SMART LOCKABLE,REAM 3R METER*48581931 }}}��� W co =9-RE==• 1=R MODULE ti YI EQUIPPED MITI RAPID SHUT METER SOCKET. UL LISTED KA W O � •U�' DOWN FORM 23,200A GANG OPEN BLADE DISCONNECT SUPPLY SIDE 0 t' 1 W Z N d Z 120240V READILY INTERCONNECTION d W Z ID F JUNCTION BOX NEMA 9R EXTERIOR MOUNT AS PER 705.12(A) W 9 Q 2 g 1 2 3 07 08 e09v.uLusTED -IL Nam _ GRID CC w V o Li IA — 0 • 'gam Z �~ -- ° L 100A AC COMBINER PANEL, _jag_ H I <0 O 0- III MI .. o o NEMA 3R,UL LISTED.WITHOUT "ti u� +oa Ci = W -7,--* o- G MAIN BREAKER 0 `\ 69A �N d C D #1,30A BREAKER FROM 5 KW A 0 L U< Z 1 #1,BOA BREAKER FROM 10 KW 0 I win : . d• U CATS FOTZjCOMM. L �m ® 0 -- I `ry'0" PROJECT ID:MAEVE18.15-958 . I ----✓4 �1 G 100A,240V BREAKER CAN 125A MAIN SERVICE SOLAREDOE TECHNOLOGIES }I 604 MAIN BREAKER 100A MAIN BREAKER PREPARED ON:09/14/2021 SE1000SH-US,NEMA 9R IA. �--�/► "'--iiilll INDOOR RATED 120I24W DRAWN BY: V.N. LIST®,INTEGRATED GFDI --....2.. F UL LIST® EATON AND DC DISCONNECT. WITHIN IE OF THE TAP P3SOLAR EDGE ER EQUIPPED WITH RAPID SHUT IVCHECKED BY: S.T. 1 PER MODULE DOWN "' O STAMPED BY: S.W. REC . .■ 1 1 A UTWTY:EVERSOURCE JUNCTIONIIII MI 9t H A PE STAMP WITH SIGNATURE p BOX 1 p �,UL Sk O NOTE 1:ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER ACCORDING TO NEC ARTICLE 890.45,AND BE A MINIMUM OF IA THE REQUIREMENTS OF NEC ARTICLES 250&690 #10AWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG SHALL BE __ - . a 4 NOTE 2:PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USED WHEN EXPOSED TO DAMAGE .___o.___oo ' USING MODULE LUGS OR RACKING INTEGRATED GROUNDING NOTE 7:GROUNDING AND BONDING CONDUCTORS,IF INSULATED, o` I CLAMPS AS ALLOWED BY LOCAL JURISDICTION.ALL OTHER SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF#4AWG a EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED OR LARGER o- LAY-IN LUGS. NOTE 8:DISCONNECTING MEANS SHOULD BE ACESSIBLE WITHIN 1 2 3 11 12 91 C1 E NOTE 3:GROUNDING SYSTEM COMPONENTS SHALL BE LISTED 10'OF THE SUPPLY SIDE CONNECTION,IT CAN BE A FUSED FOR THEIR PURPOSE DISCONNECT OR A MANUALLY OPERATED CIRCUIT BREAKER —.OE NOTE 4:IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A NOTE 9:INSTALLATION SHOULD BE NEC 2020 CODE COMPLIANT VERIFIABLE GROUNDING ELECTRODE,IT IS THE CONTRACTORS NOTE 10:EQUIPMENT SHOULD BE SERVICE RATED RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING NOTE 11:WIRE SIZING SHOULD BE AS PER 690.31(NEC 2020) — ELECTRODE. NOTE 12:NEUTRAL AND GROUND SHOULD BE BONDED ONLY NOTE 5:AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC) ONCE SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#8AWG IF —11 2 3 13 14 BARE WIRE. PAGE DESCRIPTION 1,--..--,-.4.-.- NOTE 8:EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED PV 7 ELECTRIC DIAGRAM BILL OF MATERIALS CATEGORY MAKE&MODEL QTY DESCRIPTION MODULE REC TWIN PEAK SERIES BLACK,330TP3M,330W 55 REC 330W,MONO-CRYSTALUNE BOB INVERTER SOLAREDGE TECHNOLOGIES(1)SE10000H-US,(2)SE5000H-US 1(EACH)' HD WAVE SETAPP INVERTER(1)SE10000H-US,(2)SE5000H-US W/RGM& AZ)LCONSUMPTIUON METER POWER OPTIMIZERS SOLAR EDGE P340 55 SOLAR EDGE 340W DC OPTIMIZERS(ONLY WITH SE INVERTERS) COMMUNICATION CELL KIT SOLAREDGE CELL-B-R05-US-S-S2 CELL 1 MODEM WITH 5 YRS FOR RESIDENTIAL SETAPP INVERTERS CT CLAMPS SOLAR EDGE SEACT0750-200NA-20 200 CT 2 SOLAR EDGE CTs ONLY FOR SUNNOVA PROJECTS AC COMBINER PANEL 100A COMBINER EATON OR EQUI. - 60A,240V 3W 1 PH AC COMBINER PANEL,NEMA 3R AC FUSIBLE DISCONNECT SQUARE D DU222NRB OR EQUIV. 1 100A,OVER CURRENT PROTECTION DEVICE AS USTED IN NEC 2020 AC NON FUSIBLE DISCONNECT SQUARED DU222RB OR EQUIV. 1 100A,OVER CURRENTPROTECTION DEVICE AS USTED IN NEC 2020 EPC COMPANY SUMMIT ENERGY GROUP JUNCTION BOX EQUIVALENT JUNCTION BOX 1 DC COMBINER ENCLOSURE,600VDC,120A,UL1741,NEMA 3R,CSA C22.2 FUSES BUSS FUSETRON OR EQUI. 2 80A,240VAC FUSES 293 UBBEY INDUSTRIAL PKWY, BACK FEED BREAKER/BREAKER CAN MAIN EATON OR EQUI. - 80A,2P MODE OF INTERCONNECTION,MAX RATED VOLTAGE:240VAC UNIT 250,WEYMOUTH, MA 05789,USA MA SMART METER/GENERATION METER SQUARE D OVERHEAD OR UNDERGROUND METER SOCKET 1 200A,120/240V,NEMA 3R SMART METER SOCKET 888�78�618 CONDUIT RUN EMT TBD ONSITE ;"OR 1"EMT CONDUIT RUN SHOULD BE INSTALLED AS PER THE CODE www.summitsolarenerGY.wm TRENCH RUN RIGID PVC SCHEDULE 80 TBD ONSITE TRENCH SHOULD BE AT LEAST 18"DEEP.USE WARNING TAPE DURING BACKFILL CUSTOMER DETAILS z COMPONENT SPECIFICATIONS WR D_ n mu, �c a Z O.,,,LU t MODULES z W < F- w TEMP.COEFF. FUSE D a CO= g MAKE&MODEL QTY. PMAX PTC ISC VOC VMP OF VOC RATING g <86 0- REC TWIN PEAK L m = W 3 BLACK 55 330W 246W 10.39A 39.9V 34.3V -0.28%/°C 20A U% - i SERIES x POWER OPTIMIZERS MAXIMUM MAXIMUM DC PROJECT ID:MAEVE18.15 958 MAKE&MODEL RATED INPUT QTY OUTPUT INPUT MAXIMUM DC WEIGHTED PREPARED ON:09/14/2021 POWER CURRENT CURRENT VOLTAGE EFFICIENCY DRAWN BY: V.N. SOLAR EDGE P340 340W 55 15A 13.75A 48V 98.8% CHECKED BY: S.T. STAMPED BY: S.W. UTILITY:EVERSOURCE INVERTER - S AM- ONA • - MAX CEC MAKE& Qom, AC GROUND RATED OUTPUT MAX INPUT MAX INPUT WEIGHTED MODEL VOLTAGE POWER CURRENT CURRENT VOLTAGE EFFICIENCY SOLAR EDGE 1 240V FLOATING 5000W 21A 13.5A 480V 99% 5000 H-US SOLAR EDGE 1 240V FLOATING 10,000W 42A 27A 480V 99% 10000 H-US RAIL AND MOUNTS RAIL RAIL #OF #OF MID #OF END #OF MOUNTS TYPE LENGTH #OF RAILS MODEL MOUNTS CLAMPS CLAMPS GLUGS IRONRIDGE XR100 FLASH ALL 14'EACH 28 118 92 38 18 PAGE DESCRIPTION BLACK FOOT2 BLACK PV Q BILL OF MATERIALS ON METERS, SERVICE PANELS, CONDUITS INVERTER, AC DISCONNECTS PHOTOVOLTAIC SYSTEM ALL WARNING: PHOTOVOLTAIC AC DISCONNECT POWER SOURCE ONALL CONDUITS,EVERY 1O ELECTRIC SHOCK HAZARD A WARN I N GA TURN OFF PHOTOVOLTAIC DUAL POWER SUPPLY AC DISCONNECT PRIOR TO IF GROUND FAULT IS INDICATED SOURCES UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DC JUNCTION BOX WORKING INSIDE PANEL ALL NORMALLY GROUNDED ELECTRIC SHOCK HAZARD CONDUCTORS MAY BE DO NOT TOUCH TERMINALS EPC COMPANY: ON MAIN SERVICE PANEL TERMINALS ON BOTH THE UNE AND LOAD saes SUMMIT ENERGY GROUP ONJUNCTTONBOX ONROOF UNGROUNDE4DANDENERGIZED MAY BE ENERO�ZEO�NTHEOPENPoS�T�ON PHOTOVOLTAIC ONINVERTER OPERATING VOLTAGE=VOLTS OPERATING CURT NTS MPS zS3 UNIBT 250EY N WEYMOUTH DUSTRIAL WY, MA 02189.USA SYSTEM kWh METER DUAL POWER SUPPLY PHOTOVOLTAIC SYSTEM ON AC DISCONNECT INSIDE AND OUTSIDE 8B8-578 NEM TO METER www.summItsolerenergy.com ON SMART METER SOCKET SOURCES:UTILITY GRID AND EQUIPPED WITH CUSTOMER DETAILS PV SOLAR ELECTRIC SYSTEM RAPID SHUTDOWN ill .Ir i ,1 PHOTOVOLTAIC SYSTEM z ADC DISCONNECTA ON UTwrYMETER MAIN SERVICE PANEL ON ALL AC DISCONNECTS ?g 8 TURN RAPID LO D OI .- SHOPERATING VOLTAGE �VDC �DOWN � w TO THE"OFF n SHUT d'w _AMPS PV SYSTEMREDUCETAND I a w z F wz �� d z OPERATING CURRENT MAX SYSTEM VOLTAGE VDC SOLAR CIRCUIT HAZARD IN THE w g SHORT CIRCUIT CURRENTAMPS BREAKER IS BACKFED ARRAY. 1111111 fe- m '' w ON SMART METER SOCKET DO NOT RELOCATE NEC 890.88(C)(1xa) g a x 5 z a. w THIS OVERCURRENT DEVICE a ON INVERTER ON MAIN SERVICE PANEL WHEN USING o BACK FEED O ESS PROJECT ID:MAEVE18.15.958 PREPARED ON:09/14/2021 DRAWN BY: V.N. ESS- CHECKED BY: S.T. ENERGY STORAGE RATED FREQUENCY:=. STAMPED BY: S.W. SYSTEM DISCONNECT PHASES:1m UTILITY:EVERSOURCE RATING(kW/kVA):_ — AVAILABLE FAULT CURRENT DUAL POWER SUPPLY ELECTRIC SHOCK HAZARD P MPW/TH SI NA E NOMINAL ESS AC VOLTAGE:m (AT OUTPUT TERMINALS):_ MAXIMUM OUTPUT AND INPUT CURRENT MAXIMUM ESS DC VOLTAGE:mg (AT OUTPUT TERMINALS):_ SOURCES:UTILITY GRID AND MAXIMUM OUTPUT AND INPUT VOLTAGE PV SOLAR ELECTRIC SYSTEM TERMINALS ON THE LINE AND ON ESS DISCONNECT (AT OUTPUT TERMINALS):_ LOAD SIDES MAY BE ENERGIZED UTILITY-INTERACTIVE CAPABLE:_ UTILITY GRID,ESS AND PV SOLAR ELECTRIC IN THE OPEN POSITION ON ATS,INVERTER,BATTERY CABINET SYSTEM ON THE NET METER NOTE:PLACARD FORMAT IS PROVIDED FOR REFERENCE.INFORMATION FROM RAPID SHUTDOWN RAPID SHUTDOWN PV7,THE SINGLE LINE DIAGRAM WILL BE ADDED AND INSTALLED ON ALL DISCONNECT 1/2 DISCONNECT 2/2 APPLICABLE UTILITY,STATE AND LOCAL REQUIRED PLACARDS USED FOR THIS INSTALLATION BEFORE PROJECT INSPECTION AND COMPLETION PAGE DESCRIPTION ON ESS DISCONNECT ON INTERACTIVE SYSTEM DISCONNECT PV 9 PV LABELS t t; i rn n gEn `^ ig a 3s 'ft5 o❑ tine,, , 's <- . • : .' n II g $5$ 4 yy� n x 8 i�- 9S f 11$ 'i, . Ti �S _4 -7 °';'''Ai j L' k Z t a WAN e m ti HI 1II1 0 111 g Y' CO g g6 5 aCAd uInt-s ; =7 14 _5 %„„4:2„ ,,,, _ - 6, 0 i ai '' ti W� o Vg93611715.11 Z animia OD 11l� N) N) N) 1-- aa #3aij8 Ul 0 o lis o t5 § aQ (-1 11`�#I a inguI ii teas{ia m ® m m fi7 in CI si = -r3/4'� w LAURE PIERRE c ;O y 4 cmi Z Q RESIDENCE o 6 c c 3 G i movmmzi c 3 FA' -Im o •C m,< < - 0 40 CAPTAIN BACON RD,SOUTH g o g z m 6 D y o •m o; YARMOUTH,MA 02664,USA 2 B!2 y i Dy 0 -1 c�Se li n p PHONE: 774 810 5729 s �' y • p m DC NAMEPLATE RATING:18,150 W C m 3 / Power Optimizer ../2(\ For North America Power Optimizer O P320/P340/P370/P400/P401/P405/P485/P505 For North America . * , ,• •.• 1 , • P320/P340/P370/P400/P401/P405/P485/P505 M INPUT EPC COMPANY: Pale spo 0C Rrvm 320 340 370 eco aos T nes (0 w SUMMIT ENERGY GROUP • u,o .M' mum Inpuwatage!....- e: 50 fA s 83 It 2 5 W� b amps, A1VPT operating Range 1 8- e e•w e-80 , e-60 12 5•ws __ ,2s�e3 319 299 LIBBEY INDUSTRIAL PKWY, YEAR r _- __--__--._- Mav Shortc<,Current t0, 11/s a Am UNIT 250.WEYMOUTH, wnRRAnrY;' O nxl •'' — '- _-- MA 02789,USA ---- --- ------ M ,en IX Input Current 13.75 --- i2s N65 12.5 ,r.5 AAc M rwm EacK,xy 99 s % 888.6768818 111111111 !I/ 1.0 Weighted Mercy r,-... 960 96.6 % www.summlbolaronergV.I:om OweloYag.Caf RNy --.-- �. N OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) CUSTOMER DETAILS Mmrmurn Output Current 5 Aac... — Mapenurn Output stalage 60 - ..... - 85 1 We OUTPUT DURING STANDEY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output tallage per Power iD, - -- 0 rD=_ N Opmomee STANDARD COMPLIANCE W _ N 1 Silk EMC {.____. FCC Par115[Iass8.18C61000-6.2,1376100063— as C.) O Z Safety IE(67/0911 las Icty).01.1741 _W z C ■ • ■ MNteral -..-.- U194V0 UV Resistant -...._ ---.... D.W Z 0 op )— w5 t Ill o T INSTALLATION SPECIFICATIONS j co ± r Ill Mammon Mimed System — 1000 wl 5 D: Z I w 5 I — MURage7.. (071-1 Compatible 's -..A 5nlarEAge S rgk P n Three Phaseinserters _-. ---.. '1.0 0 W Di IW r L.30 1M/153x25/5rb.11 --- - -- 1129.153 335 129 153 7951 291159x„96/5163.1.9 en 129/162/59/ _-- _ D. I. i /51.6 3 /S136x„6 51 6e x2.3 /'n 0 Q WegNl iW ny cables) 630/14 _... I 750/1 655/11 1 -__815/19 1064/l3 9/Ib } Z InputCwxlertµ MC4' Ts1,Mk4r OUN MC4 I7µ3 Wire Length 016/0.52 en r ft Output Wire Type/rmterin [bub-insolated/Mce PROJECT ID:MAEVE18.15-958 Output Wee Length 09/191 -- 12/39 mllt PV power optimization at the module-levelpe g n m6;mRange'. V « .as/M .165 C/'E PREPARED ON:09/14/2021 Rating 1V69/NEA6V DRAWN BY: V.N. Rel we lls,m,tly 0 W % CHECKED BY: S.T. / Specifically designed to work with SolarEdge / Fast installation with a single bolt1,RaleL, 64mee.umeea5,r„,I�,K,a,ee1,Ike e' rnt1.1«I,11 1I9h,.,. M.I,.k.,n, iii:n.,wL� 4 «, •1na00611( 1 » o,NEC ,.r, Ron. vllii,a,,r WV STAMPED BY: S.W. inverters f / Next generation maintenance with module- tl k r P I e+n. .K. UTILITY:EVERSOURCE I Up to 25%more energy level monitoring 5/I”'"`pe /e 'N t,^4 ef,IC f,.* 04 "" ""' e 0 34015 0117119471111911e del., PE STAMP(Wil/ IG RE I Superior efficiency(99.5%) / Meets NEC requirements for arc fault 9 types protection utdown System(PVRSS) M " c. r s,n 1,' 10 a;�,1 II rection(AFCI)and Photovoltaic Rapid / Mitigates all of module mismatch losses, m slang Length P400.P401 Piro, ,R from manufacturingtolerance to partial (Powe Optimizers) P400 Pool P405 P485,P505 1 6 8 14 shading / Module-level voltage shutdown for installer M s ,y Length(Powe Optamp I 25 25 50" and firefighter safety t 5700(6000 with I Flexible system design for maximum space Maximum Powe,per String SE7630 US SE11e00 0 6000' 12150'" w utilization Pa IkIStringsat tinea orO ..._.-. --- -.__- Yes -- ._...... _..__-_ 161 7,m,ww megrrrurrm�,�er„m �w.µ smug ilia R ! yuelatriri, ug •pal aameu to mu Pa05l+b5h1U',IN nPf>ory MOrv3rpaaWrvbl I�one Pnm9 AA eeunw Poi 3V to rear N[ll•aµ etyar.vYw n,,n1 191toe3WVyb eNWna10nMWuPto650JW Pei amp xtaig lM mnunIp�rrt roe.evxr Wnwetieext'uiivr a,IXxlw� solar�C�'t' yoll�:77,,�Pg.I,r,.a�>m„1n:�wIW.,,Slr..wtoff a,�9.1M11..,�ak.,e,v .�R.,e,.e��,....,,.,.r.,�, solaredge.com E E (�j�,p °'.' ' z1....Li A: ".»` °°a P.,a .e.,a.l,.a�aw.1.ea..olSdart4.e N..Iw �r� RoMs rr . M laAelANR wM.NWw,mm,ege ww,Pole.. Mali* PAGE DESCRIPTION PV 11 MLPE DATA SHEET 6. j IuJ 8 µ7 4.-416-0-1-14-11-i 'LSM' ;� 4- {g m• 13 .,2r- 23 1 ! t -13 $ a� � ,� ��S -,.-,.,,z-.;,-,• 4 '� *IAM �`0'��,6{� 1 {n {� � `V V E s ') a _ (, T ,• '! .• ,� '� m Q $ ' 1 x , ? a - q1 I fi44:42:,, ,!'`� '�t�- ,, „ .mow N E Z j ? vi % * , •• 2 '�, CU Y! O O C M S " r• • _-, ` N C xC git=� T,„ Airf oI I / • `s • ta titCDk ‘.< 5 N Mill 0 IP N O S213.1 13AN I io � w ts sl_ s s i s i A1-g' .141.R a g s � £�I�FR dK N1� i 8 I e a '. a &. g I a3 s o 3 • SI 3 ,.?,49'.;-;,t ' i , g11 R gi s 31 11 4 z d i f I i RIR gj -ko g , m � V1 11 '411F.1118 i �I I1 3 3. 5 R Ail 9 V W ig iii ia ( I � of ; 4it { N N v 13 3 III i 1 1 , 1 I 11 ''. � !& H ` b � � T \� If g j 1 j I I I •I g g= Zo=SS 7 : g `= _ g —1 t r _ _ j 1 sly 1 cD fmg t - s$ N- I tom ?A! ii g � g 1 ' f 4 m 1 - I I � ? D , = cIC 1 o m , i Z I< 7, 1 I I F a 1 ' 1 0l 1 0 ja1 3. { { 1 - 3 3 I 1 -1 1 P 3 e ,^m - � t� , 414 ���• I x I � F Ti n v v m m O LAURE PIERRE 2 c H A Fa ~ RESIDENCE c 3 $ o v m m. y 3 -ia m 1 13 m wm < vv 93 < < z •• 40 CAPTAIN BACON RD,SOUTH 1 I I Z m o o C ` y co < o YARMOUTH,MA 02664.USA A 2 e,'fin ,y ilio b@' O [ '. 73 N Q m i PHONE: 774-810-5729 i l i o m g s Fa N— N . 1 o m DC NAMEPLATE RATING:18,150 W o C I 3 o kr iil P If I lii }a jtb•ggq `" Z F i ll q - c II S x in y III'I !j V m es 1 ,,. kid r ,. ';1 4 ili Iii 111 a i.i.is i'i.I 11 ' l3 !� t QC I 1 cn nI liI It1!! ii - ( i ii; 4 , y1 z g11 o- II i, �� 0 1 (1111 _,.1�.. N iii IF I III or ;!P7 i I i t 11 " roaistia— ' !lilt 'R iii"i 11;111 211111 i • I r V;:::' i 1,7"':7.11;„;'; I ; 1 1.12 i i ° it t iti iffn i ; ii'li[ 0 I flit! ' 1 ifif 1 ;It /1 i !it, iiiii 1 111 i ir i li g A r m m LAURE PIERRE c y y f RESIDENCE i E 3 � � g co o m v o < my y 3 mm 3 m z q 40 CAPTAIN BACON RD,SOUTH i w G s-z = o D c 0 to < o YARMOUTH,MA 02664,USA a t o m m ; I' W ° m ? rg PHONE: 774-810-5729 y i n V F A -.aDC NAMEPLATE RATING:18,150 W ' c v C m g - v