Loading...
HomeMy WebLinkAbout2022 Dec 19 J.M. O'Reilly & Associates, Inc. LETTER OF Engineering& Land Surveying Services 1573 Main Street,2nd Floor,P.O. Box 1773 TRANSMITTAL Brewster, MA 02631 (508)896-6601 Fax(508) 896-6602 TO: DATE: JOB NUMBER: Yarmouth Board of Health 12/14/2022 6699W 1146 Route 28 South Yarmouth, MA 02664 REGARDING: 37 Moss Road South Yarmouth, MA Shipping Method: Regular Mail n Federal Express Certified Mail n UPS Priority Mail n Pick Up Express Mail Hand Deliver ❑ COPIES DATE DESCRIPTION 1 12/08/22 Perc-Rite Maintenance Checklist For review and comment: For approval: As Requested: For your use: REMARKS: cc: John M. O'Reilly P.E., P.L.S Oakson, Inc. Client DEC 1 Y Zull From: GJB If enclosures are not as noted,kindly notify us at once ROUTINE OPERATION AND MAINTENANCE CHECKLIST FOR PERC-RITE DRIP DISPERSAL SYSTEM Address: 37 Moss Road Date: 12/08/2022 Homeowner: Johnson Residence Operator: Greg Brehm VWVfO Lic#:16149 Job #: 8913W HISTORICAL DATA and CURRENT READINGS Previous flow meter reading: 30,024 Design flow: 330 Date of last visit: 12/02/2021 Current flow meter reading: 55,994 Calculated water usage: 70.0GPD Start-up dose rate Current dose rate ZONE 1: GPM 2.5 GPM ZONE 2: ZONE 3: ZONE 4: FIELD CONDITIONS A. Drip dispersal field: visible wet spots YES❑ NO D Comments: B. Air release valves: erosion YES ❑ NOD leakage/spraying YES❑ NOD Comments: PUMP CHAMBER/FLOAT OPERATION A. Floats match pin lights in control panel YES❑✓ NOD Comments: B. Alarm float working YESD NOD Comments: C. Solids or scum present YESD NOD Comments: CONTROL PANEL A. Switches in AUTO position YESD NOD Comments: B. Peak Level light on YESD NOD Comments: C. Power and Run lights on (microprocessor) YES❑✓ NOD Comments: PUMP and VALVE OPERATION A. Pump in HAND position: flow meter running YESD NOD Comments: B. Zones 1-4 (one at a time): flow meter running YES El NOD dose rate correct YES ✓❑ NO❑ flush rate > dose rate YES❑✓ NOD Comments: C. Disc filter back flushing: working properly YES❑✓ NOD Comments: D. Disc filter inspection: excessive residue YES❑ NOD cleaning required YES❑ NOD Comments: E. Switches returned to AUTO position YES El NO❑ Comments: F. RESET/CYCLE START: functioning properly YESD NO ❑ Comments: G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO Comments: SEPTIC and/or PRE-TREATMENT TANKS Septic Tank covers not @grade,did not inspect A. Examine and clean effluent filter: excessive residue YESD NO❑ Comments: B. Septic tank pumping recommended YES D NO ❑ 1. Sludge depth: 2. Scum depth: Comments: C. Service pre-treatment system YESD NOD Comments: N/A Operator signature License No. 16149 Comments/Observations: System is operating correctly mechanically.