ROUTINE OPERATION AND MAINTENANCE CHECKLIST
FOR
PERC-RITE DRIP DISPERSAL SYSTEM
Address: 37 Moss Road Date: 12/08/2022
Homeowner: Johnson Residence
Operator: Greg Brehm VWVfO Lic#:16149
Job #: 8913W
HISTORICAL DATA and CURRENT READINGS
Previous flow meter reading: 30,024 Design flow: 330 Date of last visit: 12/02/2021
Current flow meter reading: 55,994 Calculated water usage: 70.0GPD
Start-up dose rate Current dose rate
ZONE 1: GPM 2.5 GPM
ZONE 2:
ZONE 3:
ZONE 4:
FIELD CONDITIONS
A. Drip dispersal field: visible wet spots YES❑ NO D
Comments:
B. Air release valves: erosion YES ❑ NOD
leakage/spraying YES❑ NOD
Comments:
PUMP CHAMBER/FLOAT OPERATION
A. Floats match pin lights in control panel YES❑✓ NOD
Comments:
B. Alarm float working YESD NOD
Comments:
C. Solids or scum present YESD NOD
Comments:
CONTROL PANEL
A. Switches in AUTO position YESD NOD
Comments:
B. Peak Level light on YESD NOD
Comments:
C. Power and Run lights on (microprocessor) YES❑✓ NOD
Comments:
PUMP and VALVE OPERATION
A. Pump in HAND position: flow meter running YESD NOD
Comments:
B. Zones 1-4 (one at a time): flow meter running YES El NOD
dose rate correct YES ✓❑ NO❑
flush rate > dose rate YES❑✓ NOD
Comments:
C. Disc filter back flushing: working properly YES❑✓ NOD
Comments:
D. Disc filter inspection: excessive residue YES❑ NOD
cleaning required YES❑ NOD
Comments:
E. Switches returned to AUTO position YES El NO❑
Comments:
F. RESET/CYCLE START: functioning properly YESD NO ❑
Comments:
G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO
Comments:
SEPTIC and/or PRE-TREATMENT TANKS
Septic Tank covers not @grade,did not inspect
A. Examine and clean effluent filter: excessive residue YESD NO❑
Comments:
B. Septic tank pumping recommended YES D NO ❑
1. Sludge depth:
2. Scum depth:
Comments:
C. Service pre-treatment system YESD NOD
Comments: N/A
Operator signature License No. 16149
Comments/Observations:
System is operating correctly mechanically.