Loading...
HomeMy WebLinkAboutEngineer PlanPROPOSED 1500 GALLON PLASTIC SEPTIC TANK STRIPOUT BOUNDARY - TO SUITABLE "B" HORIZON 6,23 a PETER T. yam, McENTEE v CIVIL No. 35109 FEMA FLOOD DESIGNATION MAP NUMBER: 25001CO589J EFFECTIVE DATE: JULY 16, 2014 ZONE AE (EL11) 0 7.57 O d- N Z %/7,16 21 10 LOT 11 s ,� 09 20" 5,484fS.F, 6500, PATIO ME X\ \ °EXISTING, \ , `HOUSE #26) \. y T.O. F.= .8± k CELLAR FLOOR EL = 1. O 7,37 6 �A 0 x h7. 7,15 )F I-' .10`�p'�7p 24'"'`•�=�: 6.71 `� \ 45 SHELL 7,21 r U 00 -- PARKING R=474.69'.. ` 616 PK SET .' 5,97 5,81 1 Tom. ;F.L PATIO f 7.01 ;Permit valid _QN t . V, due t i *a 1 d of Heatt r 7.16 11Nny future CBDH sewage facilities d \ Varm iq C EXISTING SEPTIC SYSTEM ESTIMATED LOCATION NO RECORD AVAILABLE CONTRACTOR SHALL LOCATE, PUMP, FILL AND ABANDON OR REMOVE `—INSTALL NEW SLEEVED WATER SERVICE AIR OF SEPTIC SVSTENt and local septic variances: and approval is required for strenovations/alterations to LEGEND x 6.32 EXISTING SPOT GRADE 7 -- ---- EXISTING CONTOUR 7.9 PROPOSED SPOT GRADE —C }+ — PROPOSED CONTOUR ---- - EXISTING WATER SERVICE EXISTING GAS SERVICE - OVERHEAD WIRES TEST PIT BENCHMARK �,N! 1 71-21 LOCUS MAP wstructures/dwelling. GENERAL NOTES: Health ]Department 1 ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL IRO • ED I BOARD OF HEALTH AND THE DESIGN ENGINEER. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: 310 CMR 15.405(1)(b)&(h): CONTENTS OF LOCAL UPGRADE APPROVAL t 1) A 5' variance, septic tank to cellar wall, for a 5' setback. 2) A 4' variance, S.A.S. to cellar wall, for a 16' setback. 3) A 1' reduction to the required separation between adjusted high groundwater and bottom of S.A.S., for 4' of separation. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ELEVATIONS ARE BASED ON NAVD88f, 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8, THERE ARE NO ABUTTING WELLS WITHIN 100' OF THE PROPOSED S.A.S.. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12, AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE 5 56 LHEALTH 0INSPECTEDBY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. T. MAP ID: 34-67 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 26 MISTY LANE, SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 OWNER OF RECORD Engineers: Surveyors: SCALE DRAWN JOB. NO. SABINA—CROSSEN VICKI Engineering Works, Inc. JCEngineering, Inc. 1 "=20' P.T.M. 176-22 26 MISTY LANE 12 West Crossfield Road 2854 Cranberry Hwy. DATE Forestdole, MA 02644 E.Wareham, MA 02538 CHECKED SHEET NO. SOUTH YARMOUTH, MA 02664 (508) 477-5313 (508) 273-0377 5/10/22 P.T.M. 1 Of 2 SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE T.O.F.=8.8f -F.G. EL.=8.0t F.G. EL.=8.0t EXISTING i¢R1¢iPi L = 55' 2rMDM 24-IA @ S=1% (MIN.) 4"SCH40 PVC TOP OF TANK=7.21 44" LIQUID LEVEL 74 ADD GAS BAFFLE 1 ,'€ LIRATOR IM1530 GALLON PLASTIC TANK INV.=6.62 (CONNECT TO NEW SEWER AT HOUSE, INV.=6.70(min.) PROPOSED D-BOX INSTALL RISER & WATERTIGHT COVER SET TO 6" OF GRADE f F.G. EL.=7.8f L= 19' L=6' @ S=1% (MIN.) @ S=1% (MIN.) 4'SCH40 PVC 4'SCH40 PVC 71 -63-U 3" TO INV.=6.18 INVERT PROPOSED INV.=6.01 INV.=6.37 D-BOX INV.=5.95- NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 6.41 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL ONE INSPECTION PORT (MIN.) /--F.G. EL.=7.8t INSPECTION PORT SET 3" TO F.G. WITH PROTECTIVE FRAME & COVER 3 UNITS ® 8'/UNIT I _ 2' LENGTH=24' GEOGRID SPLASH PAD RECOMMENDED LAY FILTER FABRIC UNDER AT SOIL ABSORPTION SYSTEM (PROFILE) EXTENDING 16" IN FROM INLET 4" OF LOAM & SEED OR APPROVED FILTER FABRIC COMMON BACKFILL F.G., ELEV.=7.8t T—t�-�,-��-,a--- - 14 TOP OF STONE ELEV.=6.58 TOP OF CHAMBER ELEV.=6.41 J NOTES: INV.ELEV.=5.95 - 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE BOTTOM ELEV.=5.70 INVERTS, PRIOR TO INSTALLATION. 4' OF NATURALLY OCCURRING 2 2) SEPTIC TANK & D-BOX SHALL BE SET LEVEL AND PERVIOUS MATERIAL TRUE TO GRADE ON A MECHANICALLY COMPACTED 4' (MIN.) ABOVE G.W. STABLE BASE OR 6" COMPACTED GRAVEL BASE, AS WITH VARIANCE SPECIFIED IN 310 CMR 15.221(2). ADJUSTED G.W., EL=1.6 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <6 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY -PLASTIC INFILTRATOR IM-1530 PROPOSED DISTRIBUTION BOX: DB-3 (H-10) LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF I� III eevme, eeMemo.eeeIn. eeeeeoueeeeeeeee�eeee eeee�e�e�e�eee�e�e�e�eeeeeeee 48" (TYPICAL) I EXISTING SUITABLE SOILS/ 3 ROWS ® 4'/ROW=EFFECTIVE WIDTH=12' 1" WASHED STONE PLACED TO 6"ABOVE FIELD DRAIN UNITS - EXTEND STONE FOF 2' OUTSIDE S.A.S. FOOTPRINT SEPTIC SYSTEM PROFILE .i,r Urrv/ter USE 3 ROWS OF 3 CULTEC C-4HD UNITS WITH NO STONE FOR AN S.A.S. HAVING THE DIMENSIONS: 12.0' x 24.0'. BOTTOM AREA:(GENERAL USE APPROVAL FOR 6.7 SF/LF) 3 UNITS x 8.0'/UNIT = 24.0 FT 3 ROWS x 24.0' x 6.7 SF/LF = 482.4 SF DESIGN FLOW PROVIDED: 0.70(482.4 S.F.) = 337.7 GPD S.A.S. (SECTION) BIAXIAL GEOGRID / BX1100 PRODUCED BY TENSAR CORP. ATLANTA GEORGIA OR EQUAL EXTEND GEOGRID FOR 2' OUTSIDE S.A.S. FOOTPRINT SOIL LOG DATE: APRIL 20, 2022 SOIL EVALUATOR: PETER McENTEE SE#1542 WITNESS: JAY GARDINER HEALTH AGENT ELEV. TP DEPTH 7.1 0" FILL 6.3 10" Ab LOAMY SAND 5.8 10YR 4/2 B LOAMY SAN 10YR 5/8 4.9 C MED. SAND 2.5Y 6/4 1.6 ADJ. GW 1.2 STG. GW 15" PERC 20" 26" 66" REDOX 7.5 YR 5/8 71" 0.8 76' PERC RATE <2 MIN/IN. "B" HORIZON STANDING GW, EL.=1.2 ESTIMATED HIGH GW, EL.=1.6 (REDOX) HOUSE(#21-01 6) j 00 N I I� I IN 1 1 MODEL FD C-4 R STARTER SMALL RIB LARGE RIB n&nla C I& , MODEL FD C-4 E MIDDLE/END SMALL RIB LARGE RIBR f U�/. ��/ �-W.-AEF,1Wfi l 3" 4" DIA. 8.5" 8.5' 8.0' A» r%I A II. I �^.^\I n^r-% 12" 8�IVL"Ll 1Wl°II°II°II°II°II°II°IWI°I°II°Ir �Rl SMALL RIB LAR CULTEC CONTACTOR FIELD DRAIN C-4 CHAMBER STORAGE = 1.692 CF/FT ALL CONTACTOR FIELD DRAIN C-4HD HEAVY DUTY UNITS ARE MARKED WITH A COLOR STRIPE FORMED INTO THE PART ALONG THE LENGTH OF THE CHAMBER. CULTEC CONTACTOR FIELD DRAIN C-4HD CULTEC, Inc. PH: (203) 775-4416 � P.O. Box 280 PH: (800) 4—CULTEC CULTEC COntactorO and Recharger@ 876 Federal Road FX: (203) 775-1462 Plastic Septic and Stormwater Chambers BmkftM, CT ON" USA www.cultec.com CULTEC PROPOSED SEPTIC SYSTEM UPGRADE PLAN 26 MISTY LANE, SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. JCEngineering, Inc. N.TS. P.T.M. 176-22 12 West Crossfield Road Forestdale, MA 02644 2854 Cranberry Hwy. E.Woreham, MA 02538 DATE CHECKED SHEET NO, (508) 477-5313 (508) 273-0377 5/10/22 P.T.M. 2 Of 2