HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 22 Lot 3 00 Zone of Contribution: In_ Out_/Acreage] 3, kDo
/6 (-�de G ` vo v Cyes
Commercial: Residential:
Street: U
Village: J Floor Plan: #Bedrooms:
Owner: Installer: Qu i n'r-j
Address: Phone:
Phone:
Builder: Engineer: ' I /" c ' siw_,-, 00 v hj
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received `•/
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: /
6. Benchmark indicated and shown-NGVD if near wetlands /
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: jT
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: •
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.`
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable /'
17. System meets slope requirements-min. 1/8", %"preferred
18. System meets breakout requirements PVC liner: Wall: Z
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended use !/
23.Minimum 6"stone or compacted below tank and dbox f�
24. Manhole covers within 6"of grade,pump chamber cover to grade v
25. Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size r/
28. Septic tank/pump chamber to be factory waterproofed 1"
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber (V
31. Engineer to inspect and certify soils: wall: commercial: IV
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 1
33.H-20 loading is subject to vehicular traffic,groundwater 1 t/
34.Title V Application and permit fee,installer signature _/
35. Foundation footing min.2 feet above adjusted ground water for new house c./
36. Deed Restriction required max. #bedrooms: max. flow: gpd /--
37. Check area lots for groundwater/Label groundwater- in Assessor's Map ��
Plan reviewed by:_ G�^ts (C?t_twQ - o:o:
.� l -g d3