Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 22 Lot 3 00 Zone of Contribution: In_ Out_/Acreage] 3, kDo /6 (-�de G ` vo v Cyes Commercial: Residential: Street: U Village: J Floor Plan: #Bedrooms: Owner: Installer: Qu i n'r-j Address: Phone: Phone: Builder: Engineer: ' I /" c ' siw_,-, 00 v hj Address: Phone: Phone: N/A YES NO 1. Required#of copies received `•/ 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: / 6. Benchmark indicated and shown-NGVD if near wetlands / 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: jT 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: • 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.` 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable /' 17. System meets slope requirements-min. 1/8", %"preferred 18. System meets breakout requirements PVC liner: Wall: Z 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use !/ 23.Minimum 6"stone or compacted below tank and dbox f� 24. Manhole covers within 6"of grade,pump chamber cover to grade v 25. Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size r/ 28. Septic tank/pump chamber to be factory waterproofed 1" 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber (V 31. Engineer to inspect and certify soils: wall: commercial: IV 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 1 33.H-20 loading is subject to vehicular traffic,groundwater 1 t/ 34.Title V Application and permit fee,installer signature _/ 35. Foundation footing min.2 feet above adjusted ground water for new house c./ 36. Deed Restriction required max. #bedrooms: max. flow: gpd /-- 37. Check area lots for groundwater/Label groundwater- in Assessor's Map �� Plan reviewed by:_ G�^ts (C?t_twQ - o:o: .� l -g d3