Loading...
HomeMy WebLinkAboutEngineer Plan0 X 9 102773 rl I 4 o-1 9S0 T, DZ + GARDEN k' �'� , ) I 1w e` 102, 4 X 3 �U_ X 101.72 PROPOSED S.A.S. 2-500 GALLON CHAMBERS SURROUNDED W/4'STONE 20 X 10L59 PAVED DRIVEWAY PLAY - PATIO EXISTING SET 101.70 1017", HOUSE(# 15) EXISTING CESSPOOLS B14 T. 0. F. 102. 1 & LEACH PIT _D, TILLED TOE PGMP T V ISAND & ARA114DO!'IED 101,83 C 101,GE3 5X/ 0 X 10 P 1 n3 ,50 101X PROPOSED SEPTIC TANK- 01.17 x 0 #K BENCHMA tg li�' XPETER T, ULKHEAD P, Er� =101. 77 CIVIL ■ x 100.85 10114 X 101,63 PK SET 100,00 T 99,70 99.37 1 DO— — EXISTING CONTOUR X 100.98 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE —EXISTING GAS SERVICE N. K— OVERHEAD WIRES TEST PIT LOC BENCHMARK LEGEND GENERAL NOTES: 1 1 ALL CHANGES 1 . 0 THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER, 2, ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATfON,,S, 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKRLLED PRIOR TO JNSPECT!0N AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6, THE DESIGN PNGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TONOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7, WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WiTH;N 150' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROViNG AUTHORITIES. 10. 11' SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION, 11, WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOiLS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3), 12, AREAS REQUIRING STRiPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 11 THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSOERED TO BE A PROPERTY LINE SURVEY. 14, THE ENG'NEFR IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN PROPOSED SEPTIC SYSTEM UPGRADE PLAN 15 CAPTAIN NOYES ROAD, SOUTH YARMOUTH, MA Prepared for- Quinmos Excavation, P.O. Box 599, Forestdole, MA 02644 QWNER QE REQQ8 Surveyors! DRAWN B. NO, KEULY WILLIAM G 1"=20' 326-22 KE LY SUSAN J Engineering Woi-ks, Ine- j JC Engineering, Inc, PJ�M� 12 West Crossfield Rood 2854 Cranberry Hwy, Forestdole, MA 02644 E.Worehom, MA 02538 DATE SHEET NO. —5,313 (508) 273-0377 12/7/22 P.T.M. 1 of 2 S. YARMOUTH, MA 02664-2819 -T L 15 CAPT NOYES RD (508) 477 NOTE: TO PREVENT BREAKOUT, FINAL GRADE 35aU!�_ �TAK SHALL NOT BE AT, OR BELOW, EL.=99.1 -T & INSTALL RISERS & COVERS OVER INLET FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED S.A.S. OUTLET AND SET TO 6" OF FINsSH GRADE PROPOSED Q-QQ INSTALL RISER .0 COVER PROS.A.S. PROPOSED .3 SET TO 6" OF GRADE INSTALL RISER & COVER OVER EACH CHAMBER AND T.O,F- 102. It SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT ; I F.G.EL.=101.6± F.G. EL.-1013± F.G. EL.=102.0± F.G, EL,=102,0± 29 EXISTING HOUSE(# 15) 1 MAINTAIN 2% SLOPE OVER S.A,S. XODWOW M gi T.O` = 102. 1 L - 23' 3 max. L 35' L = 5' Ov •4 4'SCH40 PVC 4'SCH40 5=1% {MIN.) PVC 4"SCH40 PVC 2" LAYER OF 1/8' TO 1/2" DOUBLE WASHED STONE Pi F��' FC) TL Ofa (02, APPROVFIL PROPOSED S.A.S, '4 INV.-99�50 IN� 48" LIQUID —3/4" TO 1--1/2" DOUBLE 2-500 CALLON CHAMBERS LEVEL ADD INV, =98,87 INV,=98,70 48' 1 4' 1 WASHED STONE 1- 1 SURROUNDED W/4' STONE GAS BAFFLE INV.=99,25 EFFECTIVE WIDTH 12.8' 3 OUTLETS INV.=98.60 OEC 20 2022 RRQP_OSEQ_aLffM_IAI% 2-5QQ GALLON LEACjjltjG CHAMBERS 1 y [ACONNECT TO EXISTING ­SUITjKt-EWER SURROUNDED WITH STQt4E AS, SHQWN H-20 RATED T HOUSE, AT EXISITING INV.=100.0i If _,,, TOP CONC. ELEV,= BREAKOUT ELEV.= 99,10 SEPTIC LAYOUT NOTES: INV, ELEV.= 98.60 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & INVERTS EXITING HOUSE, PRIOR TO INSTALLATION, BOTTOM ELEV.= 96.60-- 2 x 8.5' - 17, 0' 4' 2) SEPlIC TANK & D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED 4' Or NATURALLY OCCURRING EFFECTIVE LENGTH = 2j SIX INCH CRUSHED STONE BASE, AS SPECW10 IN 310 CMR 15.221(2). PERVIOUS MATERIAL� 5' (MIN) ABOVE G,W� - --------- SYSTEM--SECTION a E3 E:iI E3 0 E3 21 1�1 U 3) INSTALL INLET Sc OUTLET TEES AS REQUIRED. BOTTOM OF TEST PIT, EL.=91,4 LEACHING A 00 Ea 0 37" 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE E3 E@ i� E3 E3 E3 ra E3 a E3 Ea AS MANUFACTURED BY TUr-TIIE, ZABEL OR EQUAL, tv > E3 0 Eil E3 E3 Z SEPTIC SYSTEM PROFILE 102" DESIGN CRITERIA SOIL LOG DATE: NOVEMBER 9, 2022 NUMBER Or BEDROOMS: 3 SOIL EVALUATOR: PETER McENTEE SE#1542 SOIL TEXTURAL CLAS& CLASS I {LOADING RATE-0.74 GPD/SF) WITNESS: JAY GARD!NER HEALTH AGENT DESIGN PERCOLATION RATE: <2 MIN/IN ELEV. TP DEPTH DAILY FLOW: 330 GPD 102.1 A 0" LOAMY SAND DESIGN FLOW: 330 GPD 101.7 1 OYR 3/4 5" GARBAGE GRINDER: NO --not ailowed with design B 58 _ AMY SAND LEACHING AREA REQUIRED. (330 GPD) = 445.9 SF LOIOYR 5/6 500 GALLON CAPACITY, H-20 LOADING 74 GPD/SF 99,7 CIFINE FINE SAND CHAM BERS PROPOSED SEPTIC TANK; 1500 GALLON CAPACITY 7,5YR 7/4 PROPOSED D­ROX: I INtlT, 3 OUTILFT (MiNiMUM), H-20 RATED 97.2 C2 59" USE 2-500 GALLON LEACHl%3_ _CHAM�QRSjN_SERLE_$ PROPOSED SEPTIC SYSTEM UPGRADE PLAN SURROUNDED BY DOUBLE W �Hll _DSTDhL_QN_ VERY FINE SAND 15 CAPTAIN NOYES ROAD, SOUTH YARMOUTH, MA 2.5Y 4/7 SIDEWALL AREA: 2(12;8' + 25,0') X 2 151,2 S.F, Prepared for- Quinn's Excavation, P.O. Box 5,99, Forestdole, MA 02644 BOTTOM AREA: 12.8' x 25.0' 320.0 S,F� Engineers: Surveyorc DRAWN JOB. NO, TOTAL AREA: ... ......... 471 2Sf, 91 A __J128" 1Engineering Works, Inc, JC Engineering, Inc. N.T.S. P.T.M. 326-22 12 West Crossfield Road 2854 Cranberry Hwy. DESIGN FLOW PROVIDED: 0.74 GPD/SF(471,2 SF) = 348.7 GPD NO GROUNDWATER ENCOUNTERED Forestdole, MA 02644 E,Warehom, MA 025ja DATE CHECKED SHEET NO. PERC RATE <2 MIN/IN, ("C" HORIZON) (SOB) 477-5313 (508) 273-0377 12/7/22 P,T,M. 2 of 2 4" KNOCKOUT 20" DIX COVER 4" KNOCKOUT 4" KNOCKOUT­ 4" KNOCKOUT