HomeMy WebLinkAboutEngineer PlanVARIANCES REQUESTED NONE GENERAL NOTES 1. THIS PLAN IS ONLY INTENDED FOR THE PERMITTING AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM AND ASSOCIATED SITE WORK. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO 310 CMR 15.000 AND YARMOUTH BOARD OF HEALTH REGULATIONS. S. THERE ARE NO KNOWN OR PROPOSED PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY. 4. IF AN OVERDIG IS SPECIFIED, REMOVE ALL TOPSOIL, SUBSOIL AND OTHER UNSUITABLE MATERIALS. 5. IF AN OVERDIG IS SPECIFIED, REPLACE ALL EXCAVATED MATERIALS WITHIN THE LIMIT OF EXCAVATION WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETRIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 2 INCHES. A SIEVE ANALYSIS USING A #4 SIEVE SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL UP TO 45X BY WEIGHT MAY BE RETAINED ON THE #4 SIEVE. SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS #4 SIEVE 10% MUST PASS #50 SIEVE 0-207. MUST PASS #100 SIEVE 0-5X MUST PASS #200 SIEVE 6. EXISTING UTILITIES WHERE SHOWN ON THE PLANS ARE APPROXIMATE. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL SUBSURFACE STRUCTURES ARE SHOWN. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION AND ELEVATION OF INVERTS OF UTILITIES AND STRUCTURES, WITHIN THE LIMIT OF WORK, PRIOR TO THE START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE DISCOVERED OR FIELD CHANGES REQUIRED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY COORDINATING THE PROPOSED CONSTRUCTION ACTIVITIES WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANIES, AND SHALL COMPLETE THE PROPOSED WORK WITHOUT ANY INTERRUPTIONS IN SERVICE. 8. CONTRACTOR IS REQUIRED TO NOTIFY DIG -SAFE, PER MASS. STATUTE CHAPTER 82. SECTION 40 (1-.888-344-7233) A MINIMUM OF 72 HOURS PRIOR TO THE START OF CONSTRUCTION. 9. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. INSTALLATION OR USE OF A GARBAGE GRINDER AT THIS PROPERTY IS NOT ALLOWED PER 310 CMR 15.240(4). 10. THE ENGINEER SHALL INSPECT AND CERTIFY THE BOTTOM OF THE LEACHING FIELD EXCAVATION AND UPON COMPLETED INSTALLATION OF ALL SYSTEM COMPONENTS, PRIOR TO BACKFILL HEALTH DEPT UP f7711 BENCHMARK TPOTCOF SNE w- BOUND. ELEV TsON �' `` ~ --� UP #3775 2.51I.G.V.D28 .- .� - ""�`" PLIOLIC :.. N EDGE OF- 3 � P` VE EN 14'CC. � EXIST CATER & � ' �-% � GRASS GAS LINES - sOIL rloN sYSTEM TO BE REMOVED AND P AVEM cED .- =4V MATCH �1tS71'N SEE PROFILE ON SHEE 2 + r T OF f�AL CW BCH & ENMEER TO � N F rl C " `"� f 80T {W ANt? ��ILt TO CONFTRU r PHILIP J, CHAGNON ,�� � �' IN CTION � �� / AtRTER1AL 00,PREISGUS WSTALLA ON. IF � _ __ -✓ ASSESSORS MAP ,0 f '" ti� MA Lt ABED 7tfEAt A 5' Bt07S # P ARCEI 225 � 5 I - �6-•.� � ��...:., ����� • - - • - - - �-....-� � � � ~�+raEc.,ri2s`VEN�.-_ GLASS �► EXISTING - :-0 }0 GALLON � r� ���v '- • . :~ ' � �,,, r GREASE A,,,,E TRAP � 7 1 ..n,,;:` ' • � t i-''-Y...^re ..,,,.. �-"*-..n.. ...,�..... w...•.... w„ yam•..: ' 4 NEW D-BOX WTH 9 OUTLETS AND CI MANHOLE COVER TO GRADE t� p' v • .. ' , W / , `' t 8 ff '. REMOVE EXISTING TEE AND INSTALf. IABEL 12" Ai00 MEN��,'.,~ �.. � � EXISTING 7,000 t14" PVC HEADER 7b VENT tub ON SEPTIC r� O.... 4- AB01+1= FIELD 1N� IL TANK 10 REMAIN t."r. t•' fs ' $t'. .'. . . . :' {{7 6" C.,. FROM - BUILD-11NG TO GREASE TRAP /F ANN IW SCHOR.-L" Wiz. ASSESSORS MAP 30 ` PAIDCEL 226 B eF . e ; d Ind 4 •' a ". M' i 34: r 89± S.F. ASSESSORS - STONE �j t r . r = PARCEL 22.3 �? r � r � ' .. �,� BITUMINOUS PARKING/ i g � � j F { { t Its ry .. 4 a CCS#3 g_ INSPEC77ON PORT J EXISTING RESTAURANT ENCLOSED BSC 1 I�� S T AI.�RANT � 4 T.O.F EL.=19.41' PORCH . r 2,500 GAS.. SIE 0 TIC TALK S STONE EMSTING RETAIL. STORE" 74 ± S.F. SLAB ��.^. ���... S r•ETCfS77R@-SS'�«''1g" � r MANVi � r " �r IZv T' �k ESE EXISTING CB'S AND F LEACHING BASINS -'J N/F EFTHEMIOS J. BENTAS ASSESSORS MAP 30 R _ PARCEL. 223 w •0011KO •.k. CURRENT OWNER: Mr. DAVID DEMPSEY TITLE REFERENCE: PLAN REFERENCE: ASSESSORS MAP: PARCEL: ZONING DISTRICT. SETBACKS: MINIMUM LOT SIZE: ZONE It DISTRICT: DEED BOOK 13075, PAGE 209 PLAN BOOK 371, PAGE 67 30 224 B2 FRONT 30' SIDE 25' REAR 20' 20,000 S.F. NONE FEMA FLOOD ZONE: "X" DEC 2 0 2o22 AQUIFER PROTECTION OVERLAY DISTRICT: NONE OVERLAY DISTRICT. R.O.A.D. OVERLAY DISTRICT: G.I.Z. EXISTING FRONT SYSTEM A FLOW RATES: RESTAURANT 75 SEATS X 25 GPD/SEAT = 1,875 GPD DESIGN FLOW RATE = 1,875 GPD SIZE SEC TANK A (2) COMPARTMENT TANK IS REQUIRED. THE FIRST COMPARTMENT AT 200% AND THE SECOND COMPARTMENT AT 1001/1, CAPACITY. 1,875 GPD X 300% = 5,625 GAL 7,000 GALLON TANK PROVIDED 4,500 GALLON TANK PROVIDED (1st COMPARTMENT) 2,250 GALLON TANK PROVIDED (2nd COMPARTMENT) SIZE GREASE TRAP 75 SEATS X 15 GPD/SEAT = 1,125 GAL. EXISTING 5,000 GALLON GREASE TRAP OIL ABSORPTION ARE 1875 GPD - 0:74GPD/S.F. = 2,533S.F. EXISTING 601 X 45'W LEACHING FIELD = 2,700 S.F. 2,700 S.F_ X 0.74GPDISF = 1,998 GPD 1,998 GPD PROVIDED > 1875 GPD REQUIRED EXISTING REAR (BATHROOMS) 010 GPD SYSTEM B (NO WORK PROPOSED) FLOW RATES: RESTAURANT 75 SEATS X 10 GPD/SEAT = 750 GPD 746 S.F. RETAIL STORE X 50 GPD/1000 = 38 GPD DESIGN FLOW RATE = 788 GPD S(ZE SEPTIC TANK EXISTING 2,500 GALLON TANK SOIL ABSORPTION AREA 788 GPD 10.74GPD/S.F. = 1,065S.F. PROPOSED 451 X 24'W LEACHING FIELD = 1,080 S.F. 1,080 S.F. X 0.74GPD/SF = 799 GPD 799 GPD PROVIDED > 788 GPD REQUIRED Yarmouth Health Department � APP.RQVED Date w Q� _z 0 3 �0 = Ir U 28 LOCUS LU _ w d cca Q LOCUS MAP NOT TO SCALE OF DAVID J. U CRISPIN CIVIL No.32112 orw.. �rl / t1 DAVID J. CRIS IN DATE PROFESSIONAL ENGINEER SEPTIC COMPONENT REPAIR 415 ROUTE 28 IN WEST YARM 0 UTH MASSACHUSETTS (BARNSTABLE COUNTY) KELTIC KITCHEN SITE PLAN APRIL 18, 2022 REVISIONS: NO. DATE DESC. 1 10/24 f 22 EX. TANK VOLUME PREPARED FOR: DA\AD DEMPSEY 415 ROUTE 28 WEST YARMOUTH, MA 02673 508--771-4835 is 11sc OUP 349 Main Street - Route 28 West Yarmouth, Massachusetts 02673 508 778 8919 C@ 2022 BSC Group, Inc. SCALE: 1" = 20' 0 10 20 40 Fm FILE: Projects-YAR\4816403\C\D\4816403-SP.dwg DWG.: 5269-06 SHEET 1 OF 2 JOB. NO:4-8164.03 NOT TO SCALE TEST PIT BSC 1 2000) GRD. EL 18.7' SHGW EL N A EL 18.2 EL 15.4 EL. 14.6 EL 8.7 A LOAMY SAND IOYR 3/2 B AND LOAMY S 2.5y 6,16 C-1 MEDIUM SAND 7.5YR 5/8 C-2 FINE SAND 5Y 7'/3 NO GW OBSERVED 6" EL . 19.4 28 EL 17.9 EL 17.2 49" 120' EL 9.2 TEST PIT BS 2000) GRD. EL 20.2 LEGEND SHGW EL NIA A LOAMY SAND IOYR 3/2 B LOAMY SAND 10YR 5/6 C-1 MEDIUM SAND 10YR 5/8 C-2 FINE SAND 5Y 7/3 NO GW OBSERVED ONSITE SOIL EVALUATIONS DATE- MARCH 16, 2000 TEST BY. BSC GROUP, INC. WITNESSED BY. AMY VON HONE LICENSED SOIL EVALUATOR: M. PETRIN PERCOLATION RATE: < 2 MINS./INCH SOIL CLASS: CLASS 1 LTA.R.: 0.74 GPD/S.F. UNSUITABLE MATERIALS (TO BE REMOVED) 9" PERCOLATION TEST RANGE 28 FI - 19-9 36" 82' 132" EL. 8.9 EL 5.9 TEST PIT C 1 1983) GRD. EL 18.9 SHGW EL 10.2 LOAM & SUBSOIL ELEV. = 10.2 - MEDIUM FINE WHITE SAND ELEV. = 6.9 - NO GW OBSERVE! 24' 120' 156' ONSITE SOIL EVALUATIONS DATE: JANUARY 6, 1983 TEST BY: CSS WITNESSED BY. C. WHITING LICENSED SOIL EVALUATOR: J. MACDONALD PERCOLATION RATE: < 2 MINS./INCH SOIL CLASS: CLASS 1 L.T.A.R.: 0.74 GPD/S.F. UP ;:3:7/57r " BENCHMARK � -..,.: ,•,,. . 3 I CP OF STONE L P *` BOUND. ELEVATION 2.57 N,G.\0. ROUT ~~ - `� �.. . 2(s � �..` .. 20.99 -Ptj SAC EOC� .._ 1 .Q I b." _ a_ ,max s/' ' f'kwINC��t $ _ co 44 j.. L EXIST WATER GRASS SYSTEM TO BE REMOVED AND FAVE1r1 GED7i; t A S LINES�ti�� a TAVGSEE PROFILE t�A1 2M XE AND AuN/�' . AdATFRIAL i?U!I'1 �"REt tiS INSIALLA 0N. IFPHILIP CHAGNOI 1N C710N ° �� t1N AfA $L g IiTEN A 5' 6tG"t5 �, _ ASSESSORS MAP 30 �' � � � .. ..... PARCEL 225 GRASS CONNECT EXISTING 5,000 AfGALL "... , ..... GREASE TRAP rt=5--; " �. iy�t"#�� p., { � ,+n`.w_ .�. • �', ^+.xw • : � � �.': - , . { � yT {�j'ga � - .' • ��=" y,.„y �*h i °T a.3'�•.,,,,.if+32 .f .. :.•� _ 8 `itp� +y Y did iS ""•..,.,j 1 t NEW ii-Box ii9TN 9 OUTLETS AND a MANHOLE GQYFR To 41ADE' ,V � REMOVE EXISTING TEE AND INSTALL FABEL 12' Afoo FILTER_'"'~` 4- PVC HEADER TO VENT a J EI STING, '� '"� ..... T 4' ABOVE FEEL!) 1NVER,. GALLON SEPTIC : s� �r �L - : ... `q � I LANK TO REMAIN ASSESSORS G.I. FROM STONE. _ wS PARCEL 23 d . . BUILDING TO " � 0 � BITUMINOUS PdARKINq G RIE F A � � � � a � � � 1�,. INSPEG710N PORT V LISTING INS ENCLOSED BSC1 �C-TAJ IPANT PORCH- ` SITE NOTES LEACHING FIELD PROFILE NOT TO SCALE 4" PVC VENT WITH 1.) TEST PIT CCS##1 INFORMATION WAS TAKEN FROM A PLAN PREPARED 36" MAX .C�VER CHARCOAL AIR FILTER BY DOWNCAPE ENGINEERING, INC. DATED 10/24/89, REV. 10/29/90. FINISHER GRADE ELEVATIONS AT THAT TEST PIT WERE ADJUSTED TO THE N.G.V.D. 'MIN DATUM FOR THE PURPOSE OF THIS DESIGN._ 2.) USGS GW ADJUSTMENT DATA WAS BASED ON TP CCS#1. " • , ,-. � . •�.41 � Sip PQ O.� _ •.• • - • - GROUNDWATER WAS ONLY OBSERVED IN THAT HOLE. 4PVC p� . R�a•ar-s�f�Q .AP6Y o a 6" DEPTH to -DEPTH 3.) TEST PITS BSC#1 & BSC##2 WERE COMPLETED IN GRASS AREAS / o•t oti ar a a ai or ev o+f o ag as a� oW a a 4�ar°jd�o a a a a �t a TO MINIMIZE DISTURBANCE TO PAVEMENT. EXCAVATIONS IN AREA f OF PROPOSED SYSTEM SHALL BE INSPECTED BY THE BOARD OF LEVEL BOTTOM 60' LEVEL BOTTOM !� HEALTH AND BSC TO VERIFY SOIL AND GROUNDWATER CONDITIONS PROFILE AND ESTABLISH THE LIMIT OF EXCAVATION PRIOR TO THE INSTALLATION OF THE SYSTEM. INSTALLATION OF SYSTEM IN 2000 36" MAX. - 12" MIN. COVER CONFIRMED ALL ELEVATIONS. 2" MIN. OF 1/8" TO 2% MIN. FINISH GRADE PAVED SURFACE 1/2' WASHED STONE . as �d�m o �r +Ya �y�0�3r� a o N a a U -Z)tin �1s 61.49. a °4 tt� a» o +C� a "T+-Q°��d 4r o a + a R3 �+R W dR� a o LEVEL BOT aka o�W t s . :.....::....:::::.. '.'::..:... 45' 3/4" TO 1-1/2' DOUBLE CROSS-SECTION WASHED STONE (NO FINES) 18" DIA REMOVABLE ci COVER AND FRAME H-20 CONC. RISER 5' 4" j -T 11" 24' 000 1 �:jl 3" 3' � *� BOTTOM ON LEVEL STABLE BASE 6" MINIMUM---- 24" ---�-I 3/4" TO 1-1/2- SECTION VIEW CRUSHED STONE PLAN \4 NOTES 1. DISTRIBUTION BOX TO WITHSTAND H-20 LOADING. 2. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 3. FIRST TWO FEET OF PIPES OUT OF DISTRIBUTION BOX SHALL BE LAID LEVEL 4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. 5. CONCRETE COVER SHALL BE SET WITHIN 6 INCHES OF FINISHED GRADE. 12' DIA. COVER -=19.41 D.F. I=17.51 1-17.31 EXISTING 11 1=i � 5,000 GAL GREASE TRAP TO REMAIN FIRST NOTE: MAGNETIC REFLECTIVE TAPE SHALL BE PROVIDED IN THE TRENCH OVER ALL PVC PIPING 5� REPLACE SOIL REMOVED DURING SYSTEM REMOVAL WITI TYPICAL SYSTEM PROFILE NOT TO SCALE 4" SCH. 40 PVC EXISTING FIRST PIPE LENGTH 4" SCH. 40 4' SCH. 40 PVC TO BE SET LEVEL PVC/ EXIST. L=20t FT. FOR MIN. 2' FINISH GRADE S=0.005 /-- 4" SCH. 40 PVC I=16.89 - t= NEW ZABEL,' DIST. BOX FILTER. 6` OB-9 H-20 7,000 GAL. SPL6+IENTARY 2-COMPARTMENT PPORT SEPTIC TANK (SEE IMAGE) IMAGE)-----_____ TO REMAIN OND COMPARTMENT 2,250. GALLONS 1=1 5' SEPARATION EL. 10.2 EST. HIGH GROUNDWATER I=15.70 INSPECTION PORT NOT TO SCALE THREADED CAP TO C I VALVE BOX WITHIN 3 INCHES 1 OF FINISHED GRADE -- PAVED SURFACE N \\ 3" MAX. 7 NgM INSPECTION PORT SHALL PEASTONE LAYER EXTEND DOWN TO THE BOTTOM OF THE SYSTEM PVC PIPE SAPID AND INTO THE NATURALLY OCCURRING PERVIOUS SUBGRADE O SOSOI'�L ADSORPTION 4' SCH. 40 PVC PERFORATED PIPE ACTIVATED CARBON VENT FILTER NOT TO SCALE POLY-AIRT" ACTIVATED CARBON VENT 36' (MIN.) 4" PVC VENT STACK I -TO LEACHING PIPES b co ZW$ C C O = E� C? 28 LOCUS w d _ w W 2 � i7W0 Q LOCUS MAP NOT TO SCALE OF J. DAVID CRISPIN CIVIL No�3i2 112 DAVID J. CRISPIk DATE PROFESSIONAL ENGINEER IC SEPTIC COMPONENT REPAIR 415 ROUTE 28 IN WEST YARMOUTH MAS SACH U S ETTS (BARNSTABLE COUNTY) KELTIC I{ITCHEN DETAIL PLAN APRIL 18, 2022 REVISIONS: NO. DATE DESC. 1 10/24/22 EX. TANK VOLUME PREPARED FOR: DAVID DEMPSEY 415 ROUTE 28 NEST YARMOUTH, MA 02673 508-771-4835 It III 2-C ju U 349 Main Street - Route 28 West Yarmouth, Massachusetts €12673 508 778 8919 2022 BSC Group, Inc. SCALE: 1" = 20' 0 10 20 40 per FILE: Pro jests-YAR\4816403\CAD\4816403-SP.dwg DING.: 5269-06 SHEET 2 OF 2 JOB. NO: 4-8164.03